• Title/Summary/Keyword: High performance heat sink

Search Result 78, Processing Time 0.031 seconds

An Experimental Study on the Thermal Resistance Characteristics for Various Types of Heat Sinks (다양한 형상의 Heat Sink 열저항 특성에 관한 실험적 연구)

  • 김종하;윤재호;이창식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.8
    • /
    • pp.676-682
    • /
    • 2002
  • This paper has been made to investigate the thermal performance characteristics for the several types of heat sinks such as extruded heat sink, aluminum foam heat sink, layered heat sink. The various types heat sinks are prepared and tested for natural convection as well as forced convection. The experimental results for natural convection are compared to those for three types of heat sink so that the appropriate heat sink can be designed or chosen according to the heating conditions. The overall heat transfer performances for layered heat sink, extruded heat sink and aluminum foam heat sink are almost comparable to those under natural convection and forced convection. The forced convection of layered heat sink become 1.2 times as high as those of extruded heat sink, and the forced convection of extruded heat sink become 1.2 times as high as those of aluminum foam heat sink. This study shows that bar height, bar distance and number of bar for layered heat sink are important parameters, which have a serious influence on thermal performance for layered heat sinks.

A Study on Cooling Performance of Heat Sink using Pulsating Heat Pip (PHP를 이용한 히트싱크의 냉각 성능에 관한 연구)

  • Choi, Woo-Seok;Kim, Jong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2438-2443
    • /
    • 2007
  • In order to guarantee the performance of electronic products. It is needed to improve the cooling performance of heat sink. So this paper has been made to investigate the cooling performance for the aluminum heat sink using pulsating heat pipe(PHP). The pulsating heat pipe was used as a heat spreader. Working fluid was R-22. Heater (50 mm ${\times}$ 50 mm ${\times}$ 3mm) was attached to heat sink and it generated 30W, 60W, 80W, 100W. Heat sink was tested for forced convection with 1${\sim}$4m/s of inlet air velocity. And both type heat sinks were carried out by using CFD simulation. This study showed that pulsating heat pipe can be a good tool to improve cooling performance of heat sink.

  • PDF

Shape Optimization of Heat Sink for Power Amplifier by Heat Transfer Analysis (열전달 해석에 의한 파워 증폭기 방열기의 형상 최적화)

  • Lee, Dong-Ryul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.1-6
    • /
    • 2011
  • In order to find better performance of heat sink, in this research, different cases were analysed by changing number of slots and shape of fins. Round shape fins which have wide surface showed 24% better heat transfer rate than vertical fins. There were not big discrepancies between 1 slot and 2 slots fins. Consequently, for better performance of heat sink, developments for widening surface and better material for high heat transfer rate are needed.

A Study on Cooling Performance of Aluminium Heat Sink with Pulsating Heat Pipe (PHP를 결합한 알루미늄 히트싱크의 냉각성능에 관한 연구)

  • Kim, Jong-Soo;Ha, Soo-Jung;Kwon, Yong-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1016-1021
    • /
    • 2011
  • The enhancement for cooling performance of heat sink is surely necessary to guarantee the performance of electronic products. So in this paper, the cooling performances of the aluminum heat sink with pulsating heat pipe(PHP) were investigated experimentally and numerically. The pulsating heat pipe was used as a heat spreader. Working fluid of PHP was R-22. Heat inputs were 30W, 60W, 80W and 100W, respectively. Heat sink was tested for forced convection conditions with air velocity of 1 ~ 4m/s. And CFD simulations were conducted for two different heat sinks. The results showed that the cooling performance of heat sink with pulsating heat pipe was higher than that of conventional heat sink. Therefore, the pulsating heat pipe can be a good tool to improve cooling performance of heat sink.

An Experimental Study on the Thermal Resistance Characteristics of Layered Heat Sink (적층형 Heat Sink의 열저항 특성에 관한 실험적 연구)

  • 김종하;윤재호;권오경;이창식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.4
    • /
    • pp.271-287
    • /
    • 2001
  • This paper has been made to investigate the thermal performance characteristics for the several types of layered aluminum heat sinks with offset-strip fin. Heat sinks with different fin height, fin length, number of fin layer and slanted fin are prepared and tested for natural convection as well as forced convection. The experimental results for layered heat sink(LHS) are compared to those for advanced pin fin heat sink (PHS) so that the appropriate heat sink can be designed or chosen according to the heating conditions. The overall heat transfer performances for LHS are almost comparable to those of PHS under natural convection, and become 1.2∼1.5 times as high as those of PHS under forced convection situation. This study shows that fin height and number of fin layer re important parameters, which have a serious influence on thermal performance for layered heat sinks.

  • PDF

Performance Evaluation of Heat Sink for Cooling of LED Projector (LED 프로젝터 방열용 히트싱크의 성능평가)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Jeon, Dong-Soon;Kim, Seon-Chang;Son, Kwang-Eun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1167-1171
    • /
    • 2008
  • The flow and thermal performance of the skiving and louver fin type heat sinks for the cooling system of the small LED projector were experimentally evaluated. A small fan tester based on AMCA standards was used to control and measure the air flow rate into the heat sink. Three heat blocks were used to simulate the heat and light sources(red, green and blue) of the small LED projector. We measured the pressure drop, temperatures and input power at the specific air flow rate and discussed those results. As a result, it is found that the louver fin type heat sink has higher pressure drop and lower thermal resistance than the skiving type. From the comparison of the temperature of the heat block between skiving and louver fin type, the louver fin type heat sink was found to be more suitable for cooling the high power heat source than skiving type. The thermal performance of the fan-sink(louver fin type) system was discussed with the picture taken by a thermal video.

  • PDF

A Study on Adhesive for High Efficiency LED Light Using Nano Silver

  • Kim, Sungsu;Park, Hyunbum
    • International Journal of Aerospace System Engineering
    • /
    • v.1 no.1
    • /
    • pp.44-47
    • /
    • 2014
  • This study proposes a development for the nano silver adhesive, which is applicable to high efficiency LED(light-emitting diode) light. The important issue of LED light is heat exhaust from LED. Generally, the middle area of LED light is increased up to 380K. Therefore, the bottleneck between LED chip and heat sink are caused by high temperature. In this work, the adhesive material between LED Chip and heat sink was newly developed for improvement of bottleneck. The nano silver was adopted to solve heat problem of chip on board package for LED light. In order to evaluate the performance of the nano silver adhesive, the thermal analysis was performed. Moreover both adhesive performance and heat exhaust were verified through the prototype test. From the experimental test results, it is found that the developed nano silver adhesive has the high performance.

Cooling Performance of a Microchannel Heat Sink with Nanofluids (나노유체를 냉각유체로 사용하는 마이크로채널 히트 싱크의 냉각효율)

  • Jang, Seok-Pil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.9
    • /
    • pp.849-854
    • /
    • 2005
  • In this paper, the cooling performance of a microchannel heat sink with nano-particle-fluid suspensions ('nanofluids') is numerically investigated. By using theoretical models of thermal conductivity and viscosity of nanofluids that account for the fundamental role of Brownian motion respectively, we investigate the temperature contours and thermal resistance of a microchannel heat sink with nanofluids such as 6nm copper-in-water and 2nm diamond-in-water. The results show that a microchannel heat sink with nanofluids has high cooling performance compared with the cooling performance of that with water, the classical coolant. Nanofluids reduce both the thermal resistance and the temperature difference between the heated microchannel wall and the coolant.

Comparative Analysis of Heat Sink Performance At 1U Rack Mountable Server (1U 렉마운터블 서버에서의 힛싱크 성능에 대한 비교 분석)

  • Shin, Jung-Yong;Lee, In-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1472-1475
    • /
    • 2004
  • Current processor power consumption has dramatically increased and already reached 115 Watts. Therefore, Heat sink design needs more high accuracy in 1U server. The target performance of heat sink is very dependent of fin geometry and it is also seriously affected by design conditions such as fan type, air duct shape and heatsink design parameters. The present paper investigates the behavior of heat sink performance under various conditions. The present work addresses pressurized type plane fin heat sinks having dimension of 40 mm by 40 mm by 56 mm fan.

  • PDF

Thermal Performance of a Heat Sink According to Insulated Gate Bipolar Transistor Array and Installation Location (IGBT 배열과 설치 위치에 따른 히트 싱크 방열 성능)

  • Park, Seung-Jae;Yoon, Youngchan;Lee, Tae-Hee;Lee, Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Thermal performance of a heat sink for an inverter power stack was analyzed in terms of array and installation location of an Insulated Gate Bipolar Transistor (IGBT). Thermal flow around the heat sink was calculated with a numerical model that could simulate forced convection. Thermal performance was calculated depending on the array and location of high- and low-power IGBTs considering the maximum temperature of IGBT. The optimum array and installation location were found and causes were analyzed based on results of numerical analysis. For the numerical analysis, experiment design considered the installation location of IGBT, ratio of heat generation rates of high- and low-power IGBTs, and velocity of the inlet air as design variables. Based on numerical results, a correlation that could calculate thermal performance of the heat sink was suggested and the maximum temperature of the IGBT could be predicted depending on the installation method.