• Title/Summary/Keyword: High ozone concentration

Search Result 294, Processing Time 0.026 seconds

The Characteristics of a Superposed Discharge Type Ozonizer with Variation of Mesh in Internal Electrode (내부전극 조밀도 변화에 따른 중첩방전형 오존발생기의 특성)

  • Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.87-93
    • /
    • 2005
  • In order to develope high concentration$\cdot$yield ozonizer, superposed discharge type ozonizer using overlap of silent discharge and internal electrode of mesh type has been designed and manufactured. It consists of three electrodes(central electrode, internal electrode and external electrode) and double gaps(gap between central electrode and internal electrode, gap between internal electrode and external electrode). Therefore, ozone is generated by overlapping silent discharges generated between the gaps respectively for which the AC high voltages applied to the internal electrode and the external electrode has a $180{[^\circ]}$ phase difference and for which the central electrode is a ground Ozone generation characteristics proportional to mesh of internal electrode by increasing of discharge electrode and controlling of discharge power density. As a result, the in maximum ozone concentration, generation, and yield can be obtained 17,720[ppm], 5.4[g/h], and 205[g/kwh] respectively.

Domestic Ozone Sensitivity to Chinese Emissions Inventories: A Comparison between MICS-Asia 2010 and INTEX-B 2006 (중국 배출량 목록에 대한 국내 오존 민감도 분석: MICS-Asia 2010와 INTEX-B 2006 비교사례)

  • Kim, Soontae;Bae, Changhan;Kim, Eunhye;You, Seunghee;Bae, Minah;Lee, Jae-bum;Seo, Inseok;Lim, Yongjae;Kim, Byeong-Uk;Kim, Hyun Cheol;Woo, Jung-Hun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.5
    • /
    • pp.480-496
    • /
    • 2017
  • CMAQ (Community Multiscale Air Quality)-HDDM (High-order Direct Decoupled Method) simulations with MICS-Asia 2010 and INTEX-B 2006 emissions inventories were performed to investigate the impact of Chinese $NO_x$ and VOC emissions on 1-hr ozone concentrations over South Korea during May to July in 2014. Chinese $NO_x$ and VOC emissions in MICS-Asia 2010 were 60% higher and 100% lower than those in INTEX-B 2006 during the simulation period. It makes the ratio of Chinese VOC to $NO_x$ emissions in INTEX-B 2006 (Case 1) is 3.2 times higher than that in MICS-Asia 2010 (Case 2). When the observed period mean 1-hr ozone concentration averaged across 106 air monitoring sites in the SMA (Seoul Metropolitan Area) was 37.6 ppb, the modeled values were similar to each other; 37.3 ppb for Case 1, and 40.4 ppb for Case 2. Both cases show that daily maximum 1-hr ZOC (Zero-Out Contribution) of Chinese $NO_x$ and VOC emissions were as high as 55 ppb and 35 ppb for the episode respectively. Correlation coefficients between ZOC of Chinese $NO_x$ and VOC emissions and the SMA daily maximum 1-hr ozone were 0.49~0.69. It indicates that Chinese emissions occasionally affect the SMA daily ozone peaks. On the other hand, Case 2 predicted 7 ppb and 1 ppb higher ZOC of Chinese $NO_x$ and VOC emissions than Case 1, when simulated ozone in the SMA is over 80 ppb. It implies that upwind $NO_x$ emissions would be more important than upwind VOC emissions for the long-range transport of ozone in Northeast Asia.

Comparison of Air Pollution Characteristics in the Center Lane-Bus Stop and the Surrounding Areas (중앙차선 버스 정류장과 주변지역의 대기오염 특성 비교)

  • Lee, Yong-Ki;Kim, Woong-Soo;Hong, Soon-Mo;Shin, Eun-Sang
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.378-386
    • /
    • 2014
  • The use of bus stop in the center lane has reduced the emissions of exhaust gas on the road due to the improvement of the traffic speed but has caused a health problem for the citizens who are waiting for the bus in the platform, and thus the air pollution control of bus stop in the center lane is emerging as a more important part. This study was conducted to investigate the air pollution degree for the center lane-bus stops in four regions using mobile air measuring vehicle, and to evaluate the characteristics of air pollution by comparing with the data measured at the urban air monitoring site close to the bus stops. In addition, the correlation analysis was performed to analyze the impact to neighboring region by vehicle exhaust gas. The regional mean concentration of nitrogen dioxide in the center lane-bus stops ranged from 0.025 to 0.043 ppm which shows from 2.5 times to 5.3 times higher than the values of urban air monitoring site selected as a control group. The regional mean concentration of ozone in the center lane-bus stops ranged from 0.023 to 0.034 ppm which shows from 3% to 28% lower than the values of urban air monitoring site selected as a control group. The concentrations of nitrogen dioxide and ozone for the sampling regions did not exceed one hour-air quality environmental standard (0.1 ppm). The mean concentration of particulate matter for four center lane-bus stops was $28{\mu}g/m^3$ which shows about 27% higher than the values of urban air monitoring site selected as a control group, and that of particulate matter did not exceed one day-air quality environmental standard ($100{\mu}g/m^3$). In the results of correlation analysis between data from center lane-bus stops and data from urban air monitoring sites, the correlation coefficient (r) of nitrogen dioxide was relatively low as 0.316 to 0.416, and the correlation coefficient was high as the distance was close and vice versa. However, the correlation coefficient of ozone ranged from 0.167 to 0.658 and the correlation coefficient was high as the distance was far and vice versa.

A Study on the Mushrooms Cultivation Using Ozon (오존을 이용한 버섯재배에 관한 연구(1))

  • Chang, Hyun-You;Byun, Jae-Myun;Nho, Moon-Gee;Park, Soon-Ae
    • Journal of Agricultural Extension & Community Development
    • /
    • v.7 no.1
    • /
    • pp.181-191
    • /
    • 2000
  • This experiment was conducted to find out the effects of mushroom cultivation on ozone susceptibility. The mushroom media in cultivation became softening well without bad Knell when it was soaked for 120 hours. The mushroom media softening on cultivating of oyster mushroom was good and fast when the concentration of gas condition ozone is high. The concentration of gas condition ozone must control at less than 0.02 ppm at the innoculation room, 0.03 ppm at the incubating room, must not use at the sprouting mom, less than 0.02 ppm at the growing room respectively. Also at the growing room, it removes the smell of mushroom, so has a protective effects of coming into mushroom fees and disease. When the concentration of 0.02 ppm liquid condition ozone was sprinkled, it was very useful in disease protection If it was input, the storage period of mushroom fruiting body was prolonged.

  • PDF

Comparative Study on Photochemical Reactions of Aromatic Hydrocarbons in Indoor and Outdoor Smog Chambers (실내/외 스모그 챔버에서의 방향족계 탄화수소의 광화학 반응 비교 연구)

  • Dong Jong-In;Ahn Heung-Soon
    • Journal of Environmental Science International
    • /
    • v.14 no.2
    • /
    • pp.231-240
    • /
    • 2005
  • The number of cases exceeding environmental standards of atmospheric ozone in the major cities in Korea has steadily increased during the past decades. In order to understand and analyze the atmospheric reactions in the atmosphere, especially the secondary photochemical reactions, smog chambers studies have been performed very actively by many research groups worldwide. However, these studies have focused on the mechanism of photochemical reactions in high concentration conditions, not at the ambient levels. Therefore, in-depth studies in these conditions are essentially needed to realize exact mechanism in the atmosphere near the earth surface, especially at Korean atmospheric conditions. In this experiment, the mechanism of photochemical smog was examined through a comparative experiment of smog chambers under sun light and black light conditions. The results of our study indicated that concentrations of ozone, aldehyde, and PAN increased as the radiation of light source increases. Photochemical reaction patterns can be considered quite similar for both black light and sun light experiments. Based on our experiments using toluene as a reactant which is present at significant high levels in ambient air relative to other VOCs, it was found that toluene could contribute notably to oxidize NO to $NO_2$, this reaction can eventually generate some other photochemical oxidants such as ozone, aldehyde, and PAN. The results of simulation and experiments generally showed a good agreement quite well except for the case of $O_3$. The restriction of oxidization of NO to $NO_2$ seems to cause this difference, which is mainly from the reaction of peroxy radical itself and other reactants in the real gas.

Vertical Ozone Distribution over Seoul: Ozonesonde Measurements During June 6~9, 2003 (서울지역 연직 오존 분포: 2003년 6월 6~9일 오존존데 관측)

  • Hwang, Mi-Kyoung;Kim, Yoo-Keun;Oh, In-Bo;Song, Sang-Keun;Lim, Yun-Kyu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.196-205
    • /
    • 2008
  • Variability in vertical ozone and meteorological profiles was measured by 2Z electrochemical concentration cells (ECC) ozonesonde at Bangyi in Seoul ($37.52^{\circ}N$, $127.13^{\circ}E$) during June $6{\sim}9$, 2003 in odor to identify the vertical distribution of ozone and its relationship with the lower-atmospheric structure resulted in the high ozone concentrations near the surface. The eight profiles obtained in the early morning and the late afternoon during the study period clearly showed that the substantial change of ozone concentrations in lower atmosphere(${\sim}5\;km$), indicating that it is tightly coupled to the variation of the planetary boundary layer (PBL) structure as well as the background synoptic flow. All profiles observed early in the morning showed very low ozone concentrations near the surface with strong vertical gradients in the nocturnal stable boundary layer due to the photochemical ozone loss caused by surface NO titration under very weak vertical mixing. On the other hand, relatively uniform ozone profiles in the developed mixing layer and the ozone peaks in the upper PBL, were observed in the late afternoon. It was noted that a significant increase in ozone concentrations in the lower atmosphere occurred with the corresponding decrease of the mixing height in the late afternoon on June 8. Ozone in upper layer did not vertically vary much compared to that in PBL but changed significantly on June 6 that was closely associated with the variation of synoptic flows. Interestingly, heavily polluted ozone layers aloft (a maximum value of 115 ppb around 2 km) were formed early in the morning on 6 through 7 June under dominant westerly synoptic flows. This indicates the effects of the transport of pollutants on regional scale and consequently can give a rise to increase the surface ozone concentration by downward mixing processes enhanced in the afternoon.

Toluene Removal Using Surface Discharge Induced Plasma Chemical Process (연면방전 플라즈마를 이용한 톨루엔 처리에 관한 연구)

  • 부문자;봉춘근;김신도
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.4
    • /
    • pp.297-305
    • /
    • 1997
  • The experimental study by use of SPCP was fulfilled to remove toluene emitted from various industrial processes. First of all, discharge characteristic was experimented as the change of applied voltage and frequency. Then toluene removal characteristic was tested with the analysis of by-products. As a result, optimum electrical discharge condition was from 20.0 kHz to 25.0 kHz of frequency and from 3.5 kV to 4.0 kV of voltage range. The variation of applied voltage had a more important effect on the removal characteristic of toluene than the frequency variation. The toluene removal efficiency was proportioned to ozone concentration and retention time on discharge plate. It was dropped as increase of toluene concentration, but total treated volume of tolene per power consumption was high. The decomposed toluene was transformed to $CO, CO_2$ and particulates, and the rate of transformation to particulates was higher than CO and $CO_2$ at high toluene concentration. Particulates were increased from 0.017 $\mum$ to 0.3 $\mum$ range of size distribution.

  • PDF

Treatment of surface water using cold plasma for domestic water supply

  • Nguyen, Dung Van;Ho, Phong Quoc;Pham, Toan Van;Nguyen, Tuyen Van;Kim, Lavane
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.412-417
    • /
    • 2019
  • This paper presents the results of using cold plasma to treat surface water for domestic use purpose. Experimental results showed that cold plasma was an effective method for destroying bacteria in water. After treatment with cold plasma, concentration of coliform and Escherichia coli dramatically reduced. Besides, cold plasma significantly removed water odor, increased dissolved oxygen and decreased the concentration of chemical oxygen demand. However, cold plasma significantly raised the concentration of nitrite and nitrate. Other disadvantages of treating with cold plasma were conductivity increase and pH reduction. Pretreatment steps of coagulation, flocculation, sedimentation and sand filtration followed by disinfection with cold plasma exhibited a high efficiency in surface water treatment. All parameters of surface water after treatment by using the prototype satisfied with the allowance standard of domestic water quality.

Study on the Assessment of Air Quality Before and After Action Plan of Atmospheric Environment Improvement Establish at Gimhae, Gyeongnam Province (경남 김해지역의 대기환경개선 실천계획 수립 전후의 대기질 평가에 관한 연구)

  • Park, Jong-Kil;Jung, Woo-Sik;Kim, Seok-Cheol;Kim, Eun-Byul
    • Journal of Environmental Science International
    • /
    • v.17 no.10
    • /
    • pp.1111-1120
    • /
    • 2008
  • In order to study the degree of improved air quality as an outcome of the action plan of Atmospheric Environment Improvement in Gimhae, Gyeongnam Province, we investigated the status and trends of air pollutant before and after the plan. Nitrogen dioxide and ozone, both classified as hazardous substances, were closely monitored with particular attention. The level of sulfur dioxide, nitrogen dioxide, fine particles and ozone (but for carbon monoxide) was decreased after the plan was implemented. The number of days on which ozone exceeded the National Ambient Air Quality Standard has decreased, but the level was still often exceeded. The level of nitrogen dioxide did not surpass until the 2006 standard, but when the revised 2007 standard was implemented, it exceeded 80% of some standards. The yearly level of ozone has decreased since the plan was introduced. The concentration of nitrogen dioxide, however, has reduced in high order area while increased in low order area.

Vulnerability Assessment of Human Health Sector due to Climate Change: Focus on Ozone (기후변화에 따른 보건 분야의 취약성 평가: O3을 중심으로)

  • Lee, Jae-Bum;Lee, Hyun-Ju;Moon, Kyung-Jung;Hong, Sung-Chul;Kim, Deok-Rae;Song, Chang-Keun;Hong, You-Deog
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.1
    • /
    • pp.22-38
    • /
    • 2012
  • Adaptation of climate change is necessary to avoid unexpected impacts of climate change caused by human activities. Vulnerability refers to the degree to which system cannot cope with impacts of climate change, encompassing physical, social and economic aspects. Therefore the quantification of climate change impacts and its vulnerability is needed to identify vulnerable regions and to setup the proper strategies for adaptation. In this study, climate change vulnerability is defined as a function of climate exposure, sensitivity, and adaptive capacity. Also, we identified regions vulnerable to ozone due to climate change in Korea using developed proxy variables of vulnerability of regional level. 18 proxy variables are selected through delphi survey to assess vulnerability over human health sector for ozone concentration change due to climate change. Also, we estimate the weighting score of proxy variables from delphi survey. The results showed that the local regions with higher vulnerability index in the sector of human health are Seoul and Daegu, whereas regions with lower one are Jeollanam-do, Gyeonggi-do, Gwangju, Busan, Daejeon, and Gangwon-do. The regions of high level vulnerability are mainly caused by their high ozone exposure. We also assessed future vulnerability according to the Intergovernmental Panel on Climate Change (IPCC) Special Report on Emissions Scenarios (SRES) A2, A1FI, A1T, A1B, B2, and B1 scenarios in 2020s, 2050s and 2100s. The results showed that vulnerability increased in all scenarios due to increased ozone concentrations. Especially vulnerability index is increased by approximately 2 times in A1FI scenarios in the 2020s. This study could support regionally adjusted adaptation polices and the quantitative background of policy priority as providing the information on the regional vulnerability of ozone due to climate change in Korea.