• Title/Summary/Keyword: High humidity

Search Result 1,699, Processing Time 0.03 seconds

Charge Transfer between STM Tip and Au(100) in Dry, H2O, and D2O Atmospheres

  • Utami, Anggi;Chung, Yonghwa;Lee, Chi-Woo
    • Journal of Electrochemical Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.153-156
    • /
    • 2013
  • Charge transfer between STM tip and Au(100) has been investigated by using a Scanning Tunneling Microscopy (STM) technique in dry, $H_2O$, and $D_2O$ atmospheres. Dry atmosphere was indicated by humidity as low as 5 % and high humidity as high as 98% was managed by injecting $H_2O$ and $D_2O$ to the chamber. The current decayed more slowly in high humidity than in dry atmosphere. The plateau currents were found to appear at separations larger than ca. $5{\AA}$ where the current decay stopped depending on applied bias voltages. The polarity dependence was observed at the STM junction between Pt-Ir tip and the gold. On the contrary, little dependence was seen at the one between Au tip and the substrate electrode.

A Locally Cured Polyimied-based Humidity Sensor with High Sensitivity and High Speed (국부적 경화된 고속, 고감도 폴리이미드 습도 센서)

  • Kwak, Ki-Young;Lee, Myung-Jin;Kim, Jae-Sung;Kang, Moon-Sik;Min, Nam-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1472-1473
    • /
    • 2008
  • Polyimide thin films were cured locally using MEMS microhotplates. The polyimide locally cured at temperature over 350$^{\circ}C$ for 1 hour was fully cured. There was no significant difference between polyimide thin films cured in a conventional convection oven and those cured locally on MEMS microhotplates. The locally cured polyimide humidity sensor showed a linearity of 0.9995, a sensitivity of 0.77 pF/%RH, a hysteresis of 0.6 %RH, and a response time of 3s. These results indicate that the locally-cured polyimide films may be used as dielectric material of high speed, highsensitivity humidity sensors.

  • PDF

Effects of High Relative Humidity on Weight Loss, Color Change, and Microbial Activity of Tomatoes during Refrigerated Storage

  • Pai, Tongkun
    • Journal of Applied Biological Chemistry
    • /
    • v.43 no.4
    • /
    • pp.250-253
    • /
    • 2000
  • The effects of high relative humidity (RH) on the physicochemical properties and microbial activity of mature green tomatoes ('Dombito') during refrigerated storage were determined at three temperatures (5, 10, and $15^{\circ}C$) and four different RH levels (91, 94, 97, and 99%). At each temperature, the weight loss rates of tomatoes at different levels of RH were significantly (p<0.05) different from each other. For the samples stored at $10^{\circ}C$, the weight losses were generally higher than those for the samples at $15^{\circ}C$ within the same RH level (i.e., greater vapor pressure deficit). The color change rates ('a' value) showed positive slopes, indicating that the tomato color was changing from green to red. Neither bacteria nor fungi caused visible damages to the samples, and the microbial counts were below 650 colony forming units/$cm^2$ during the test period.

  • PDF

Development of Accelerated Life Tests for Solid Aluminum Electrolyte Capacitor Made by Domestic Manufacturing Company and Comparison of Characteristics between Domestic Products and Foreign Advanced Products (국산 고체 알루미늄 전해 커패시터의 가속수명시험 개발 및 국외 선진업체 제품과의 특성 비교)

  • 박정원;이중휘
    • Journal of Applied Reliability
    • /
    • v.2 no.1
    • /
    • pp.1-14
    • /
    • 2002
  • High temperature operating test, temperature humidity test and temperature cycling were performed at various test levels for solid aluminum electrolyte capacitors made by domestic manufacturing company and foreign advanced manufacturing company. It was found that main failure mode of solid aluminum electrolyte capacitors was the decrease of their capacitances. The decrease of their capacitances has the same pattern in these tests. Test result for comparison of characteristics between domestic products and foreign advanced products shows that domestic products have the shorter lifetime and their capacitances decrease more rapidly in high temperature operating test and temperature humidity test. Also in these tests, accelerated tests for high temperature operating test and temperature humidity test were developed.

  • PDF

Electrical and optical properties of ITO films annealed at high humidity (고습에서 열처리된 ITO 박막의 전기적 및 광학적 특성)

  • Ma, Tae Young;Park, Ki Cheol
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.47-52
    • /
    • 2021
  • The ~185 nm thick ITO films deposited by high frequency magnetron sputtering were annealed at 100% humidity. Annealing was performed at 200℃, 250℃, 300℃, 350℃, 400℃ and 450℃ for 4 hours, respectively. Variations in resistivity, electron concentration, and mobility by high-humidity annealing were investigated. The stress change was estimated from the XRD results, and the surface morphology of films was observed through the FESEM micrographs. After measuring the light transmittance, the energy-band-gap was obtained and analyzed with the Burnstein-Moss effect.

Research on Durability Assessment of Asbestos Stabilizer for Asbestos-containing Ceiling Materials (석면 함유 천장재에 대한 석면 안정화제 내구성 평가 연구)

  • Ha, Joo-Yeon;Shin, Hyun-Gyoo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.18-27
    • /
    • 2020
  • Objectives: For testing asbestos stabilizer products which are used for the maintenance and management of asbestos-containing materials, durability assessment should accompany the evaluation of basic properties and performance. Therefore, in this study we designed a testing method and constructed a database of durability performance, thereby providing basic data for reliability studies of asbestos stabilizer. Methods: Since the ceiling materials targeted in this study are interior materials, test conditions of 95% relative humidity and 60℃ temperature were designed in consideration of the effect of high relative humidity in summer and seasonal indoor temperatures. Plate-shaped specimens treated with asbestos stabilizers were maintained in a thermo-hygrostat for 5, 10, and 20 days, and then the asbestos scattering prevention rate was measured by air erosion testing. Results: The scattering concentration tended to increase with time under the single humidity condition, and exceeded the indoor air quality standard of 0.01 f/cc, during the 20 days of maintenance. On the other hand, there was little change according to the temperature condition. In the case of a complex condition with temperature and humidity, the results were similar to the humidity test, but the scattering concentration increased more sharply at 20 days. Conclusions: The main deterioration factor that affects the durability of asbestos stabilizer is humidity, and the deterioration is caused by a mechanism in which the stabilizer coated on the surface is re-dissolved by moisture and evaporates or the coating layer is peeled off, which is accelerated by high temperatures.

A Study of Humidification Method in PEMFC (고분자전해질형 연료전지의 가습 방법에 대한 연구)

  • Hyun, Deok-Su;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.3
    • /
    • pp.212-216
    • /
    • 2003
  • The humidification measurement system designed in laboratory was used to measure relative humidity and temperature of reaction gases passing through internal or external humidifier which was used in proton exchange membrane fuel cell test station. The relative humidity of gases was stabilized after $10\~20$ minutes and thus credibility of data could be assured. The effect of relative humidity on fuel cell performance could be analyzed by humidity measurement system. Extreme caution was needed to avoid humidity sensor mal-function or failure which is probable in experiment of high humidity condition near $100\%$. The amount of water carried by gas through humidifier was increased along the flow rate of gas. However, the extent of increase was lowered at high gas flow rate. These phenomena could be analyzed as residence time effect of gas in humidifier.

Changes in Sugar Contents and Storability of Yacon under Different Storage Conditions

  • Doo, Hong-Soo;Li, Hu-Lin;Kwon, Tae-Oh;Ryu, Jeom-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.45 no.5
    • /
    • pp.300-304
    • /
    • 2000
  • Tuberous roots of yacon (Polymnia sonchifolia Poeppig & Endlicher) were stored in different temperature and relative humidity conditions after curing for 30 days. Non-decadent percentage, moisture contents, brix degree and sugars were investigated. Whether temperature and relative humidity were high or not, most of the tuberous root decayed during storage, and the decayed percentage was increased as long as the storage period. In final, only 13% of tuberous roots remain intact at 4$^{\circ}C$, 85% relative humidity condition to be appeared best storage condition in this experiment and all of the tuberous root decayed in other storage conditions after 6 months. Moisture contents decreased a little in the high relative humidity. Even though tuberous roots decayed when stored at 1$0^{\circ}C$ and 2$0^{\circ}C$, most of brix degree reached about 17.0. Fructose, glucose and sucrose contents were 1.65, 1.15 and 0.35% at early storage period, and 1.6, 1.1 and 0.5% after 6 months at 4$^{\circ}C$, 85% relative humidity, respectively. In 3 temperature conditions, fructose and glucose increased for a month and then decreased successively afterwards, but sucrose increased gradually during 6 months. Also in 4 relative humidity conditions, fructose, glucose and sucrose contents were changed with similar to that of in temperature. Changes of fructose and glucose were the same except on 4$^{\circ}C$, 85% relative humidity, that was lower level than moisture of tuberous root.

  • PDF

Effects of relative humidity on comfort sensation by comparison between the young and the aged (여름철 냉방시 상대습도가 쾌적감에 미치는 영향(청년과 고령자의 비교를 중심으로))

  • 김동규;금종수;최광환;박희욱;김종열;주익성
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.381-388
    • /
    • 1998
  • Hot and humid weather in summer generally brings about discomfort. Experiments on which relative humidity makes effects on the comfort sensation were performed to the young and the aged using sensation vote. From July to October 1996, seven college students and eleven aged people were exposed for 2 hours under six different conditions in the Pukyong National University test chamber so as to determine the effects of relative humidity on thermal and comfort sensations. Subjects were wearing same clothes, and the mean clo value was 0.5. The mean radiant temperature was equal to the air temperature and air velocity in the occupied zone around 0.lm/s. In the experiments, it was found that discomfort could be largely reduced when the humidity is controlled to low values in the settled high temperature.

  • PDF

Nanotribological Behavior of Adsorbed Water Layer on Silicon Surface (실리콘 표면에 흡착된 수분층의 나노트라이볼로지 거동)

  • 안효석;김두인;최동훈
    • Tribology and Lubricants
    • /
    • v.19 no.5
    • /
    • pp.245-250
    • /
    • 2003
  • Water is known to playa crucial role on friction of moving parts in nanoscale contact. Little is, however, known about the tribological behavior of a solid surface that is covered with water adsorption layer. The objective of this study is to investigate the nanotribological behavior of the water layer in relation to water affinity of the surface and relative humidity. This paper presents an examination of the frictional behavior of water adsorption layer as 'confined liquid film'. It is shown that the friction is inversely proportional to the hydrophilicity of surface and relative humidity. On the other hand, friction of hydrophobic surface is not influenced by relative humidity. A model is proposed for the water-mediated contact in which it is shown that the water layer between two hydrophilic surfaces with high relative humidity behaves as a lubricant.