• 제목/요약/키워드: High humidity

검색결과 1,699건 처리시간 0.027초

CCTV통신용 함체내의 항온항습 자동제어 장치 개발 (Internal communication as CCTV Automatic Climate Control System Development)

  • 김희철
    • 한국전자통신학회논문지
    • /
    • 제10권4호
    • /
    • pp.433-439
    • /
    • 2015
  • CCTV용 함체 내부는 일정한 습도와 온도를 유지시켜 습윤에 의한 단락방지, 온도차에 의한 결로방지, 고온방지 등의 항온항습장치가 요구되며 이를 대응한 함체에 최적화된 형태와 구조, 에너지활용 정도의 항온항습 자동제어장치개발이 필요하다. 함체내부에 있는 고가의 영상장비를 온도 변환에 따른 해저드로부터 장치보호, 단락사고를 예방할 수 있는 항온항습 제어장치가 필요하다. 이는 영상기록 및 현장상황에 신뢰성 있는 영상의 저장 및 전송을 위한 부속장치가 절대적으로 요구되는 시스템이다.

Idea Factory를 통한 공학교육 혁신 활동 사례 연구 (복합재 섬유 보관용 온·습도 조절 장치 개발) (A Case Study of Innovative Engineering Education System by Idea Factory (Development of Temperature-Humidity Control Device for Fiber Storage on Composites))

  • 박수정;김윤해
    • 공학교육연구
    • /
    • 제20권1호
    • /
    • pp.63-68
    • /
    • 2017
  • This research is as a case study of innovative engineering education system through idea factory of korea maritime and ocean university and deals with development of temperature-humidity control device (THCD) for fiber storage on composites in viewpoint of problem solving method. Fiber reinforced plastic (FRP) includes many variables on the composite manufacturing process. Above all, the interfacial adhesion between the fiber and the matrix acts as an important thing that decided mechanical property of the FRP, and also it is profoundly linked to external temperature and relative humidity. High void fraction leads to a result in interlaminar fracture. Therefore, in this research, to establish correlation between fiber reinforcement and fiber storage conditions of temperature and relative humidity we developed a THCD for fiber reinforcement. To evaluate performance of the THCD, glass fiber reinforced plastic (GFRP) is made under the extreme conditions each temperature $34^{\circ}C$, relative humidity 98 % and it can be said that there are the change of mechanical properties according to fiber storage conditions. As a result, the THCD showed sufficient possible application for understanding and applied research of composites field in material engineering. Also, we could check that the necessity of introduction of innovative system such as idea factory existed.

습도조절용 세라믹패널 및 도료의 흡·방습성능 평가 (Performance Evaluation of Water Vapour Adsorption & Desorption Properties of Ceramic Panel and Painting Materials for Humidity Control)

  • 장건영;류동우
    • 대한건축학회논문집:구조계
    • /
    • 제34권3호
    • /
    • pp.43-52
    • /
    • 2018
  • This study is conducted to evaluate the performance of ceramic panels and painting materials for humidity control which are developed in non-plastic room temperature hardening structure as part of a project to improve a residential environment for the low-income class, rather than the performance of high-priced humidity control materials that are produced with the existing plasticity processing. The testing methods included the measurements of absorption & desoprtion of humidity per material; Mock-up Testing; an evaluation method of comparing the absorption & desoprtion performances of Ecocarat, ceramic panels and painting materials through Living Lab. According to the measurements of absorption & desoprtion per material, ceramic panels, E panel, and ceramic painting material showed 73.3g/m2, 96.6g/m2, and 111.1g/m2, respectively. That is, the performance of humidity control of each material was found to be good in the order of: Ceramic Paint > E panel > Ceramic Panel. According to performance evaluation testing with Mock-up test and Living Lab, Ceramic Paint, Ecocarat, and Ceramic Panels showed better absorption & desoprtion performances in the order.

탄소 섬유/에폭시 복합 재료의 마찰 및 마멸 성질에 미치는 습도 및 구조의 영향 (Effects of Humidity and Structure on Friction and Wear Properties of Carbon Fiber/Epoxy Composites)

  • 심현해;권오관;윤재륜
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1990년도 제12회 학술강연회초록집
    • /
    • pp.63-68
    • /
    • 1990
  • Friction and wear behavior of a unidirectional high modulus carbon fiber reinforced epoxy composite exposed to high and low humidity was experimentally examined with various sliding speeds. The results show that the moisture at the sliding surface greatly influences friction and wear properties of the composite. It is also discoverd that the difference in friction and wear behavior between samples with different fiber orientations is mainly due to the anisotropic properties caused by the microstructure of oriented graphite crystals in the carbon fibers and the macrostructure of fiber orientation in the matrix.

  • PDF

탄소 섬유/에폭시 복합 재료의 마찰 및 마멸 성질에 미치는 습도 및 구조의 영향 (Effects of Humidity and Structure on Friction and Wear Properties of Carbon Fiber/Epoxy Composites)

  • 심현해;권오관;윤재륜
    • Tribology and Lubricants
    • /
    • 제6권2호
    • /
    • pp.88-93
    • /
    • 1990
  • Friction and wear behavior of a unidirectional high modulus carbon fiber reinforced epoxy composite exposed to high and low humidity was experimentally examined with various sliding speeds. The results show that the moisture at the sliding surface greatly influences friction and wear properties of the composite. It is also discoverd that the difference in friction and wear behavior between samples with different fiber orientations is mainly due to the anisotropic properties caused by the microstructure of oriented graphite crystals in the carbon fibers and the macrostructure of fiber orientation in the matrix.

경기도 소재 고등학교 급식소의 위생·안전관리와 작업구역별 공기 품질 간의 관련성 (Relationship between Air Quality of Functional Areas and Hygiene Safety Management Performance in High School Foodservices in Gyeonggi Province)

  • 김정리;장혜자
    • 대한영양사협회학술지
    • /
    • 제23권4호
    • /
    • pp.350-362
    • /
    • 2017
  • The study examined evaluated the sanitation management state of the high school foodservice operations, as measured by temperature, humidity and airborne bacteria concentration in functional areas and further identified their relationships. Data were collected from 26 high school foodservices in Gyeonggi Province. Statistical analyses were conducted with the SPSS program using descriptive analysis and spearman's correlation. The sanitation management performances in high school foodservice scored 86.85 out of 100 points and showed higher scores in the dimensions of preparation and storing management (17.85/20 points), operation management (17.78/20 points), and cooking utensil management (17.62/20 points), while the dimensions of cross contamination management as well as personal hygiene management needed action plans for prompt improvement. The airborne bacteria concentration was highest in the dining area (179.2 CFU/plate), and requiring action plans for improvement. The relative humidity in functional areas ranged from 66.5% in the receiving area to 74.4% (dish-washing area) and the temperature of the preparation area showed an average of $25.1^{\circ}C$ with the highest of $35.4^{\circ}C$ in the dish-washing area. In terms of the relationships among airborne bacteria, temperature, and humidity, the concentration of airborne bacteria was negatively correlated with and temperature in the dish-washing area (r= -0.693, P<0.05), and no other significances were shown in the other areas.

활선애자점검기의 개발 및 154kV 선로에의 적용 - 제2부 : 진단 알고리즘 개발 (Development of Live-line Insulator Tester and Its Application to 154kV Power Lines - Part 2 : Inspection Algorithm Development)

  • 박준영;이재경;조병학;오기용
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.89-95
    • /
    • 2010
  • A new live-line insulator tester was developed to detect faulty insulators in 154kV power transmission lines. This paper is the second part of the two-part paper and deals with its inspection algorithm development. Unlike normal condition with low pollution and low humidity, the inspection data measured in the field under high pollution or high humidity showed that the voltage distribution of an insulator string has offsets in comparison with those of others and its insulation resistances are greatly decreased, which leads to wrong results of the existing inspection algorithms under such conditions. To solve this problem, we propose new diagnosis algorithms that can exactly detect faulty insulators from measured data regardless of environmental conditions. Its effectiveness was validated by live-line field tests in actual power lines.

콘크리트의 블리딩에 미치는 환경 및 시공요인의 영향 (Influence of Environment and Construction Factor on the Bleeding of Concrete)

  • 황인성;김기정;나운;김규동;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.65-68
    • /
    • 2003
  • This study is intended to look into the influence of environment and construction factor on bleeding of concrete. According to the results, as wind is light, relative humidity is high and temperature is low, the amount of bleeding increases greatly, and evaporation speed is influenced greatly by order of wind, temperature and humidity. As the properties of bleeding by construction factor, the amount of bleeding increases with an increase of placing thickness, but the bleeding ratio, the amount of bleeding per unit volume, increases with a decrease of the placing thickness. Bleeding speed is fastest at about 90 minute after placing concrete. Also, as wind is light, relative humidity is high, temperature is low and the placing thickness is thick, bleeding speed grow faster.

  • PDF

전기영동법에 의해 제작된 폴리이미드 박막의 습도특성II (The Characteristics of Polyimide Humidity Sensor Fabricated by Electrophoretic Deposition)

  • 조동헌;한상옥;박강식;정승용;박찬흠;박귀만;김종석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1728-1731
    • /
    • 1996
  • To develop more sensitive humidity sensor on high temperature region, in this paper, we prepared polyimide humidity sensor by electrophoretic method. Sensing properties of be sensor in high temprature region were studied and compared with that prepared by solution casting method. From the result, the thiner film thickness, the more sensitive. however, It is difficult to make he thickness optimal because of short between electrodes, and the thickness of upper electrode is one of most important parameters affecting pefomance of the sensor.

  • PDF

Effects of Storage Environmental Conditions on Weight Loss, Whiteness Change, and Microbial Activity of Mushrooms (Agaricus bisporus)

  • Pai, Tongkun
    • Journal of Applied Biological Chemistry
    • /
    • 제43권3호
    • /
    • pp.161-164
    • /
    • 2000
  • The effects of storage temperature and high relative humidity (RH) on the weight loss, color change, and microbial activity of a mushroom ('Sylvan' hybrid white) were investigated. The experiment was performed at three temperature (5, 10 and $15^{\circ}C$) and four different relative humidity levels (91, 94, 97 and 99%). The weight loss of the tested samples had a highly correlated linear relationship with storage time at each RH level during storage. Both the storage temperature and RH levels in the experiment had signigicant effects (p<0.05) on the weight-loss rate of the tested samples. The loss whiteness of mushrooms was not significantly affected (p>0.05) by RH ranges at the same temperature. No visible damage was caused by either bacteria or fungi in all samples during storage.

  • PDF