• Title/Summary/Keyword: High frequency signal injection

Search Result 50, Processing Time 0.022 seconds

A Sensorless Rotor Position Estimation Scheme for IPMSM Using HF Signal Injection with Frequency and Amplitude Optimization

  • Lu, Jiadong;Liu, Jinglin;Hu, Yihua;Zhang, Xiaokang;Ni, Kai;Si, Jikai
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1945-1955
    • /
    • 2018
  • High frequency signal injection (HFI) is an alternative method for estimating rotor position of interior permanent magnet synchronous motor (IPMSM). The general method of frequency and amplitude selection is based on error tolerance and experiments, and is usually set with only one group of HF parameters, which is not efficient for different working modes. This paper proposes a novel rotor position estimation scheme by HFI with optimized frequency and amplitude, based on the mathematic model of IPMSM. The requirements for standstill and low-speed operational modes are met by applying this novel scheme. Additionally, the effects of the frequency and amplitude of the injected HF signal on the position estimation results under different operating conditions are analyzed. Furthermore, an optimization method for HF parameter selection is proposed to make the estimation process more efficient under different working conditions according to error tolerance. The effectiveness of the propose scheme is verified by the experiments on an IPMSM motor prototype.

PD measuring on MV XLPE Calble by Using UWB Antenna (UWB 안테나를 이용한 MV급 전력케이블의 부분방전 측정 연구)

  • Yang, Sang-Hyun;Lim, Kwang-Jin;Lee, Yong-Sung;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.267-268
    • /
    • 2008
  • This paper presents compact low frequency ultra-wide band(UWB) sensor design and studying of the partial discharge diagnosis by sensing electromagnetic pulse emitted from the partial discharge source with new designed UWB sensor. In this study, we designed new type of compact low frequency UWB sensor based on microstrip antenna technology to detect both low frequency and high frequency band of partial discharge signal. And experiments of offline PD testing on in medium voltage (22.9kV) underground cable and mention the comparative results with the traditional HFCT as a reference sensor in the laboratory. In the series of comparative test, the calibration signal injection test provided with conventional IEC 60270 method and high voltage injection testing are included.

  • PDF

Virtual Signal Injected MTPA Control for DTC Five-Phase IPMSM Drives

  • Liu, Guohai;Yang, Yuqi;Chen, Qian
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.956-967
    • /
    • 2019
  • This paper introduces a virtual signal injected maximum torque per ampere (MTPA) control strategy for direct-torque-controlled five-phase interior permanent magnet synchronous motor (IPMSM) drives. The key of the proposed method is that a high frequency signal is injected virtually into the stator flux linkage. Then the responding stator current is calculated and regulated to compensate the amplitude of the flux linkage. This is done according to the relationship between the stator current and the stator flux linkage. Since the proposed method does not inject any real signals into the motor, it does not cause any of the problems associated with high-frequency signals, such as additional copper loss and extra torque ripple. Simulation and experimental results are offered to verify the effectiveness of the proposed method.

HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade (154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용)

  • Lee, Jung-Soo;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.214-217
    • /
    • 2008
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding Power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF

Maximum Torque per Ampere Control of Interior Permanent Magnet Synchronous Motor based on Signal Injection (실시간 신호 주입을 이용한 매입형 영구자석 동기 전동기의 단위 전류당 최대 토크 제어)

  • Kim, Sung-Min;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.142-149
    • /
    • 2010
  • Interior Permanent Magnet Synchronous Motor(IPMSM) have gained an increasing popularity in recent years for a variety of industrial applications, because of their high power density, high efficiency and possibility of flux weakening operation. Because the efficiency of IPMSM is one of the important performance characteristic, the Maximum Torque Per Ampere(MTPA) operating method has been indispensible. In theory, MTPA operating point can be calculated using the exact values of the machine parameters. However, the values of the IPMSM parameters are known to vary widely according to the operating condition. Therefore, to operate the IPMSM in the MTPA operating point, the machine parameters should be estimated in real-time. In this paper, the new MTPA operating method based on the signal injection is presented. By injecting the high frequency current signal, the MTPA operating criteria can be calculated by measuring the input power to IPMSM. The proposed method can find the MTPA operating point with simple signal processing regardless of the parameter variation.

Measurement of Basis Signal with HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade (154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용 기준신호 측정연구)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Lee, Kyung-Yong;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.217-219
    • /
    • 2005
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF

Measurement of Basis Signal with HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade (154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용 기준신호 측정)

  • Ahn, Jong-Hyun;Yun, Ju-Ho;Choi, Yong-Sung;Park, Dae-Hee;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.75-78
    • /
    • 2007
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF

Characteristics of the Avalanche Injection on SiO2Layer in MOS Structures (MOS 구조에서의 Avalanche Injection에 관한 연구)

  • 성영권;김성진;백우현;박찬원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.6
    • /
    • pp.244-252
    • /
    • 1985
  • A model is presented to explain charging phenomena into the oxide layer when a metal-oxide-silicon(MOS) capacitor is driven by a large amplitude and high frequency ac signal sufficient to produce avalanche injection in the silicon. During avalanche, minority carriers are injected. It is assumed that some of these minority carriers attain sufficient energy to surmount the potential barrier at the interface, and then inter the oxide. Measurements of C-V curves are made for the MOS capacitor with p-type silicon substrates before and after avalanche injection. This paper studies how charging in the oxide and the interface depends on oxide properties. It is concluded that this charging effect is related to the presence of water in the oxide.

  • PDF

All-optical Flip-flop Operation Based on Polarization Bistability of Conventional-type 1.55-㎛ Wavelength Single-mode VCSELs

  • Lee, Seoung-Hun;Jung, Hae-Won;Kim, Kyong-Hon;Lee, Min-Hee
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.137-141
    • /
    • 2010
  • We report, for the first time to our knowledge, observation of polarization bistability from 1.55-${\mu}m$ wavelength single-mode VCSELs of a conventional cylinder-shape under control of their driving current, and demonstration of all-optical flip-flop (AOFF) operations based on the bistability with optical set and reset pulse injection at a 50 MHz switching frequency. The injection pulse energy was less than 14 fJ. The average on-off contrast ratio of the flip-flopped signals was about 7 dB. These properties of the VCSELs will be potentially useful for future high-speed all-optical signal processing applications.

Sensor less Speed Control of Induction Motor at Wide Speed Control Range Using High Frequency Voltage Signal Injection (고주파 전압 신호주입을 이용한 속도검출기가 없는 유도전동기의 광범위 속도 제어)

  • Son, Yo-Ch'an;Ha, Jung-Ik;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.182-185
    • /
    • 1998
  • This paper describes a field orientation control of an induction motor without any speed transducer and proposes a wide-range speed control strategy with the field orientation algorithm. The difference at impedances between the direct and quadrature axis at the injected signal is used for the sensorless field orientation control. But this algorithm has some limitations and should be supported by other method at high speed. In this paper, a sensorless speed control at an induction motor for wide speed range operation is proposed. The proposed algorithm is verified by experimental results.

  • PDF