• Title/Summary/Keyword: High Technology

Search Result 48,564, Processing Time 0.081 seconds

Deep Learning-based Professional Image Interpretation Using Expertise Transplant (전문성 이식을 통한 딥러닝 기반 전문 이미지 해석 방법론)

  • Kim, Taejin;Kim, Namgyu
    • Journal of Intelligence and Information Systems
    • /
    • v.26 no.2
    • /
    • pp.79-104
    • /
    • 2020
  • Recently, as deep learning has attracted attention, the use of deep learning is being considered as a method for solving problems in various fields. In particular, deep learning is known to have excellent performance when applied to applying unstructured data such as text, sound and images, and many studies have proven its effectiveness. Owing to the remarkable development of text and image deep learning technology, interests in image captioning technology and its application is rapidly increasing. Image captioning is a technique that automatically generates relevant captions for a given image by handling both image comprehension and text generation simultaneously. In spite of the high entry barrier of image captioning that analysts should be able to process both image and text data, image captioning has established itself as one of the key fields in the A.I. research owing to its various applicability. In addition, many researches have been conducted to improve the performance of image captioning in various aspects. Recent researches attempt to create advanced captions that can not only describe an image accurately, but also convey the information contained in the image more sophisticatedly. Despite many recent efforts to improve the performance of image captioning, it is difficult to find any researches to interpret images from the perspective of domain experts in each field not from the perspective of the general public. Even for the same image, the part of interests may differ according to the professional field of the person who has encountered the image. Moreover, the way of interpreting and expressing the image also differs according to the level of expertise. The public tends to recognize the image from a holistic and general perspective, that is, from the perspective of identifying the image's constituent objects and their relationships. On the contrary, the domain experts tend to recognize the image by focusing on some specific elements necessary to interpret the given image based on their expertise. It implies that meaningful parts of an image are mutually different depending on viewers' perspective even for the same image. So, image captioning needs to implement this phenomenon. Therefore, in this study, we propose a method to generate captions specialized in each domain for the image by utilizing the expertise of experts in the corresponding domain. Specifically, after performing pre-training on a large amount of general data, the expertise in the field is transplanted through transfer-learning with a small amount of expertise data. However, simple adaption of transfer learning using expertise data may invoke another type of problems. Simultaneous learning with captions of various characteristics may invoke so-called 'inter-observation interference' problem, which make it difficult to perform pure learning of each characteristic point of view. For learning with vast amount of data, most of this interference is self-purified and has little impact on learning results. On the contrary, in the case of fine-tuning where learning is performed on a small amount of data, the impact of such interference on learning can be relatively large. To solve this problem, therefore, we propose a novel 'Character-Independent Transfer-learning' that performs transfer learning independently for each character. In order to confirm the feasibility of the proposed methodology, we performed experiments utilizing the results of pre-training on MSCOCO dataset which is comprised of 120,000 images and about 600,000 general captions. Additionally, according to the advice of an art therapist, about 300 pairs of 'image / expertise captions' were created, and the data was used for the experiments of expertise transplantation. As a result of the experiment, it was confirmed that the caption generated according to the proposed methodology generates captions from the perspective of implanted expertise whereas the caption generated through learning on general data contains a number of contents irrelevant to expertise interpretation. In this paper, we propose a novel approach of specialized image interpretation. To achieve this goal, we present a method to use transfer learning and generate captions specialized in the specific domain. In the future, by applying the proposed methodology to expertise transplant in various fields, we expected that many researches will be actively conducted to solve the problem of lack of expertise data and to improve performance of image captioning.

A Study on analysis of contrasts and variation in SUV with the passage of uptake time in 18F-FDOPA Brain PET/CT (18F-FDOPA Brain PET/CT 검사의 영상 대조도 분석 및 섭취 시간에 따른 SUV변화 고찰)

  • Seo, Kang rok;Lee, Jeong eun;Ko, Hyun soo;Ryu, Jae kwang;Nam, Ki pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.69-74
    • /
    • 2019
  • Purpose $^{18}F$-FDOPA using amino acid is particularly attractive for imaging of brain tumors because of the high uptake in tumor tissue and the low uptake in normal brain tissue. But, on the other hand, $^{18}F$-FDG is highly uptake in both tumor tissue and normal brain tissue. The purpose of study is to evaluate comparison of contrasts in $^{18}F$-FDOPA Brain PET/CT and $^{18}F$-FDG Brain PET/CT and to find out optimal scan time by analysis of variation in SUV with the passage of uptake time. Materials and Methods A region of interest of approximately $350mm^2$ at the center of the tumor and cerebellum in 12 patients ($51.4{\pm}12.8yrs$) who $^{18}F$-FDG Brain PET/CT and $^{18}F$-FDOPA Brain PET/CT were examined more than once each. The $SUV_{max}$ was measured, and the $SUV_{max}$ ratio (T/C ratio) of the tumor cerebellum was calculated. In the analysis of SUV, T/C ratio was calculated for each frame after dividing into 15 frames of 2 minutes each using List mode data in 25 patients ($49.{\pm}10.3yrs$). SPSS 21 was used to compare T/C ratio of $^{18}F$-FDOPA and T/C ratio of $^{18}F$-FDG. Results The T/C ratio of $^{18}F$-FDOPA Brain PET/CT was higher than the T/C ratio of $^{18}F$-FDG Brain, and show a significant difference according to a paired t-test(t=-5.214, p=0.000). As a result of analyzing changes in $SUV_{max}$ and T/C ratio, the peak point of $SUV_{max}$ was $5.6{\pm}2.9$ and appeared in the fourth frame (6 to 8 minutes), and the peak of T/C ratio also appeared in the fourth frame (6 to 8 minutes). Taking this into consideration and comparing the existing 10 to 30 minutes image and 6 to 26 minutes image, the $SUV_{max}$ and T/C ratio increased by 0.2 and 0.1 each, compared to the 10 to 30 minutes image for 6 to 26 minutes image. Conclusion From this study, $^{18}F$-FDOPA Brain PET/CT is effective when reading the image, because the T/C ratio of $^{18}F$-FDOPA Brain PET/CT was higher than T/C ratio of $^{18}F$-FDG Brain PET/CT. In addition, in the case of $^{18}F$-FDOPA Brain PET/CT, there was no difference between the existing 10 to 30 minutes image and 6 to 26 minutes image. Through continuous research, we can find possibility of shortening examination time in $^{18}F$-FDOPA Brain PET/CT. Also, we can help physician to accurate reading using additional scan data.

Analysis of HBeAg and HBV DNA Detection in Hepatitis B Patients Treated with Antiviral Therapy (항 바이러스 치료중인 B형 간염환자에서 HBeAg 및 HBV DNA 검출에 관한 분석)

  • Cheon, Jun Hong;Chae, Hong Ju;Park, Mi Sun;Lim, Soo Yeon;Yoo, Seon Hee;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose Hepatitis B virus (hepatitis B virus, HBV) infection is a worldwide major public health problem and it is known as a major cause of chronic hepatitis, liver cirrhosis and liver cancer. And serologic tests of hepatitis B virus is essential for diagnosing and treating these diseases. In addition, with the development of molecular diagnostics, the detection of HBV DNA in serum diagnoses HBV infection and is recognized as an important indicator for the antiviral agent treatment response assessment. We performed HBeAg assay using Immunoradiometric assay (IRMA) and Chemiluminescent Microparticle Immunoassay (CMIA) in hepatitis B patients treated with antiviral agents. The detection rate of HBV DNA in serum was measured and compared by RT-PCR (Real Time - Polymerase Chain Reaction) method Materials and Methods HBeAg serum examination and HBV DNA quantification test were conducted on 270 hepatitis B patients undergoing anti-virus treatment after diagnosis of hepatitis B virus infection. Two serologic tests (IRMA, CMIA) with different detection principles were applied for the HBeAg serum test. Serum HBV DNA was quantitatively measured by real-time polymerase chain reaction (RT-PCR) using the Abbott m2000 System. Results The detection rate of HBeAg was 24.1% (65/270) for IRMA and 82.2% (222/270) for CMIA. Detection rate of serum HBV DNA by real-time RT-PCR is 29.3% (79/270). The measured amount of serum HBV DNA concentration is $4.8{\times}10^7{\pm}1.9{\times}10^8IU/mL$($mean{\pm}SD$). The minimum value is 16IU/mL, the maximum value is $1.0{\times}10^9IU/mL$, and the reference value for quantitative detection limit is 15IU/mL. The detection rates and concentrations of HBV DNA by group according to the results of HBeAg serological (IRMA, CMIA)tests were as follows. 1) Group I (IRMA negative, CMIA positive, N = 169), HBV DNA detection rate of 17.7% (30/169), $6.8{\times}10^5{\pm}1.9{\times}10^6IU/mL$ 2) Group II (IRMA positive, CMIA positive, N = 53), HBV DNA detection rate 62.3% (33/53), $1.1{\times}10^8{\pm}2.8{\times}10^8IU/mL$ 3) Group III (IRMA negative, CMIA negative, N = 36), HBV DNA detection rate 36.1% (13/36), $3.0{\times}10^5{\pm}1.1{\times}10^6IU/mL$ 4) Group IV(IRMA positive, CMIA negative, N = 12), HBV DNA detection rate 25% (3/12), $1.3{\times}10^3{\pm}1.1{\times}10^3IU/mL$ Conclusion HBeAg detection rate according to the serological test showed a large difference. This difference is considered for a number of reasons such as characteristics of the Ab used for assay kit and epitope, HBV of genotype. Detection rate and the concentration of the group-specific HBV DNA classified serologic results confirmed the high detection rate and the concentration in Group II (IRMA-positive, CMIA positive, N = 53).

The Effect of Shading on Pedestrians' Thermal Comfort in the E-W Street (동-서 가로에서 차양이 보행자의 열적 쾌적성에 미치는 영향)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.6
    • /
    • pp.60-74
    • /
    • 2018
  • This study was to investigate the pedestrian's thermal environments in the North Sidewalk of E-W Street during summer heatwave. We carried out detailed measurements with four human-biometeorological stations on Dongjin Street, Jinju, Korea ($N35^{\circ}10.73{\sim}10.75^{\prime}$, $E128^{\circ}55.90{\sim}58.00^{\prime}$, elevation: 50m). Two of the stations stood under one row street tree and hedge(One-Tree), two row street tree and hedge (Two-Tree), one of the stations stood under shelter and awning(Shelter), while the other in the sun (Sunlit). The measurement spots were instrumented with microclimate monitoring stations to continuously measure microclimate, radiation from the six cardinal directions at the height of 1.1m so as to calculate the Universal Thermal Climate Index (UTCI) from 24th July to 21th August 2018. The radiant temperature of sidewalk's elements were measured by the reflective sphere and thermal camera at 29th July 2018. The analysis results of 9 day's 1 minute term human-biometeorological data absorbed by a man in standing position from 10am to 4pm, and 1 day's radiant temperature of sidewalk elements from 1:16pm to 1:35pm, showed the following. The shading of street tree and shelter were mitigated heat stress by the lowered UTCI at mid and late summer's daytime, One-Tree and Two-Tree lowered respectively 0.4~0.5 level, 0.5~0.8 level of the heat stress, Shelter lowered respectively 0.3~1.0 level of the heat stress compared with those in the Sunlit. But the thermal environments in the One-Tree, Two-Tree and Shelter during the heat wave supposed to user "very strong heat stress" while those in the Sunlit supposed to user "very strong heat stres" and "exterme heat stress". The main heat load temperature compared with body temperature ($37^{\circ}C$) were respectively $7.4^{\circ}C{\sim}21.4^{\circ}C$ (pavement), $14.7^{\circ}C{\sim}15.8^{\circ}C$ (road), $12.7^{\circ}C$ (shelter canopy), $7.0^{\circ}C$ (street funiture), $3.5^{\circ}C{\sim}6.4^{\circ}C$ (building facade). The main heat load percentage were respectively 34.9%~81.0% (pavement), 9.6%~25.2% (road), 24.8% (shelter canopy), 14.1%~15.4% (building facade), 5.7% (street facility). Reducing the radiant temperature of the pavement, road, building surfaces by shading is the most effective means to achieve outdoor thermal comfort for pedestrians in sidewalk. Therefore, increasing the projected canopy area and LAI of street tree through the minimal training and pruning, building dense roadside hedge are essential for pedestrians thermal comfort. In addition, thermal liner, high reflective materials, greening etc. should be introduced for reducing the surface temperature of shelter and awning canopy. Also, retro-reflective materials of building facade should be introduced for the control of reflective sun radiation. More aggressively pavement watering should be introduced for reducing the surface temperature of sidewalk's pavement.

Facile [11C]PIB Synthesis Using an On-cartridge Methylation and Purification Showed Higher Specific Activity than Conventional Method Using Loop and High Performance Liquid Chromatography Purification (Loop와 HPLC Purification 방법보다 더 높은 비방사능을 보여주는 카트리지 Methylation과 Purification을 이용한 손쉬운 [ 11C]PIB 합성)

  • Lee, Yong-Seok;Cho, Yong-Hyun;Lee, Hong-Jae;Lee, Yun-Sang;Jeong, Jae Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.67-73
    • /
    • 2018
  • $[^{11}C]PIB$ synthesis has been performed by a loop-methylation and HPLC purification in our lab. However, this method is time-consuming and requires complicated systems. Thus, we developed an on-cartridge method which simplified the synthetic procedure and reduced time greatly by removing HPLC purification step. We compared 6 different cartridges and evaluated the $[^{11}C]PIB$ production yields and specific activities. $[^{11}C]MeOTf$ was synthesized by using TRACERlab FXC Pro and was transferred into the cartridge by blowing with helium gas for 3 min. To remove byproducts and impurities, cartridges were washed out by 20 mL of 30% EtOH in 0.5 M $NaH_2PO_4$ solution (pH 5.1) and 10 mL of distilled water. And then, $[^{11}C]PIB$ was eluted by 5 mL of 30% EtOH in 0.5 M $NaH_2PO_4$ into the collecting vial containing 10 mL saline. Among the 6 cartridges, only tC18 environmental cartridge could remove impurities and byproducts from $[^{11}C]PIB$ completely and showed higher specific activity than traditional HPLC purification method. This method took only 8 ~ 9 min from methylation to formulation. For the tC18 environmental cartridge and conventional HPLC loop methods, the radiochemical yields were $12.3{\pm}2.2%$ and $13.9{\pm}4.4%$, respectively, and the molar activities were $420.6{\pm}20.4GBq/{\mu}mol$ (n=3) and $78.7{\pm}39.7GBq/{\mu}mol$ (n=41), respectively. We successfully developed a facile on-cartridge methylation method for $[^{11}C]PIB$ synthesis which enabled the procedure more simple and rapid, and showed higher molar radio-activity than HPLC purification method.

A Study on the Establishment of Acceptable Range for Internal Quality Control of Radioimmunoassay (핵의학 검체검사 내부정도관리 허용범위 설정에 관한 고찰)

  • Young Ji, LEE;So Young, LEE;Sun Ho, LEE
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.43-47
    • /
    • 2022
  • Purpose Radioimmunoassay implement quality control by systematizing the internal quality control system for quality assurance of test results. This study aims to contribute to the quality assurance of radioimmunoassay results and to implement systematic quality control by measuring the average CV of internal quality control and external quality control by plenty of institutions for reference when setting the laboratory's own acceptable range. Materials and Methods We measured the average CV of internal quality control and the bounce rate of more than 10.0% for a total of 42 items from October 2020 to December 2021. According to the CV result, we classified and compared the upper group (5.0% or less), the middle group (5.0~10.0%) and the lower group (10.0% or more). The bounce rate of 10.0% or more was compared by classifying the item of five or more institutions into tumor markers, thyroid hormones and other hormones. The average CV was measured by the overall average and standard deviation of the external quality control results for 28 items from the first quarter to the fourth quarter of 2021. In addition, the average CV was measured by the overall average and standard deviation of the proficiency results between institutions for 13 items in the first half and the second half of 2021. The average CV of internal quality control and external quality control was compared by item so we compared and analyzed the items that implement well to quality control and the items that require attention to quality control. Results As a result of measuring the precision average of internal quality control for 42 items of six institutions, the top group (5.0% or less) are Ferritin, HGH, SHBG, and 25-OH-VitD, while the bottom group (≤10.0%) are cortisol, ATA, AMA, renin, and estradiol. When comparing more than 10.0% bounce rate of CV for tumor markers, CA-125 (6.7%), CA-19-9 (9.8%) implemented well, while SCC-Ag (24.3%), CA-15-3 (26.7%) were among the items that require attention to control. As a result of comparing the bounce rate of more than 10.0% of CV for thyroid hormones examination, free T4 (2.1%), T3 (9.3%) showed excellent performance and AMA (39.6%), ATA (51.6%) required attention to control. When comparing the bounce rate of 10.0% or more of CV for other hormones, IGF-1 (8.8%), FSH (9.1%), prolactin (9.2%) showed excellent performance, however estradiol (37.3%), testosterone (37.7%), cortisol (44.4%) required attention to control. As a result of measuring the average CV of the whole institutions participating at external quality control for 28 items, HGH and SCC-Ag were included in the top group (≤10.0%), however ATA, estradiol, TSI, and thyroglobulin included in bottom group (≥30.0%). Conclusion As a result of evaluating 42 items of six institutions, the average CV was 3.7~12.2% showing a 3.3 times difference between the upper group and the lower group. Cortisol, ATA, AMA, Renin and estradiol tests with high CV will require continuous improvement activities to improve precision. In addition, we measured and compared the overall average CV of the internal quality control, the external quality control and the proficiency between institutions participating of six institutions for 41 items excluding HBs-Ab. As a result, ATA, AMA, Renin and estradiol belong to the same subgroup so we require attention to control and consider setting a higher acceptable range. It is recommended to set and control the acceptable range standard of internal quality control CV in consideration of many things in the laboratory due to the different reagents and instruments, and the results vary depending on the test's proficiency and quality control materials. It is thought that the accuracy and reliability of radioimmunoassay results can be improved if systematic quality control is implemented based on the set acceptable range.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

A Methodology of Multimodal Public Transportation Network Building and Path Searching Using Transportation Card Data (교통카드 기반자료를 활용한 복합대중교통망 구축 및 경로탐색 방안 연구)

  • Cheon, Seung-Hoon;Shin, Seong-Il;Lee, Young-Ihn;Lee, Chang-Ju
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.3
    • /
    • pp.233-243
    • /
    • 2008
  • Recognition for the importance and roles of public transportation is increasing because of traffic problems in many cities. In spite of this paradigm change, previous researches related with public transportation trip assignment have limits in some aspects. Especially, in case of multimodal public transportation networks, many characters should be considered such as transfers. operational time schedules, waiting time and travel cost. After metropolitan integrated transfer discount system was carried out, transfer trips are increasing among traffic modes and this takes the variation of users' route choices. Moreover, the advent of high-technology public transportation card called smart card, public transportation users' travel information can be recorded automatically and this gives many researchers new analytical methodology for multimodal public transportation networks. In this paper, it is suggested that the methodology for establishment of brand new multimodal public transportation networks based on computer programming methods using transportation card data. First, we propose the building method of integrated transportation networks based on bus and urban railroad stations in order to make full use of travel information from transportation card data. Second, it is offered how to connect the broken transfer links by computer-based programming techniques. This is very helpful to solve the transfer problems that existing transportation networks have. Lastly, we give the methodology for users' paths finding and network establishment among multi-modes in multimodal public transportation networks. By using proposed methodology in this research, it becomes easy to build multimodal public transportation networks with existing bus and urban railroad station coordinates. Also, without extra works including transfer links connection, it is possible to make large-scaled multimodal public transportation networks. In the end, this study can contribute to solve users' paths finding problem among multi-modes which is regarded as an unsolved issue in existing transportation networks.

Serological Approach for Selection of Bradyrhizobium japonicum Strain with Superior Symbiotic Effectiveness (Bradyrhizobium japonicum의 공생효과(共生效果) 우수균주(優秀菌株) 선발(選拔)을 위한 면역혈청학적(免疫血淸學的) 접근(接近))

  • Kang, Ui-Gum;Ha, Ho-Sung;Park, Kyeong-Bae;Lee, Sang-Kyu;Lim, Dong-Kyu;Yang, Min-Suk
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.29 no.2
    • /
    • pp.165-172
    • /
    • 1996
  • Symbiotic effectiveness and significance of Bradyrhizobium japonicum strains in five serogroups which were consisted of three corresponding serotype strains, respectively, indigenous to Korean soils were evaluated in terms of utility of strain serogroup for symbiotic improvement on soybean plant. The nodulation by rhizobia of each serogroup on four soybean cultivars(Danweonkong, Kwangkyo, Pangsakong, and Eunhakong) was good in order of USDA 123 > YCK 150 > YCK 117 > YCK 141 > USDA 110 serogroup members. Shoot dry weight of soybean was relatively high with USDA 110 serogroup members as well as with YCK 141 serogroup members, whereas the effectiveness of USDA 123 serogroup members was the lowest among the serogroups examined. In particular, Pangsakong among soybeans inoculated with five-serogroup members was positively outstanding on nodulation and shoot dry weight of the plant. Overall, symbiotic parameters of serogroup members associated with soybean plant such as nodule number, nodule mass, $N_2$ase activity, and shoot dry weight showed significantly different responses at level of 1% probability among both rhizobial serogroups and soybean cultivars, respectively. The rate in symbiotic similarity of the members of each serogroup from F-test ($$P{\leq_-}0.05$$) was 100% for nodule No., 90% for $N_2$ase activity. and 80% for soybean shoot dry weight. Taken together, the results indicated that the serological grouping of B. japonicum could be strongly useful for improving the symbiotic effectiveness hetween soybean and Rhizobium.

  • PDF

The Effect of Synchronous CMC Technology by Task Network: A Perspective of Media Synchronicity Theory (개인의 업무 네트워크 특성에 따른 동시적 CMC의 영향 : 매체 동시성 이론 관점)

  • Kim, Min-Soo;Park, Chul-Woo;Yang, Hee-Dong
    • Asia pacific journal of information systems
    • /
    • v.18 no.3
    • /
    • pp.21-43
    • /
    • 2008
  • The task network which is formed of different individuals can be recognized as a social network. Therefore, the way to communicate with people inside or outside the network has considerable influence on their outcome. Moreover, the position on which a member stands in a network shows the different effects of the information systems supporting communication with others. In this paper, it is to be studied how personal CMC (computer-mediated communication) tools affect the mission that those who work for a network perform through diverse task networks. Especially, we focused on synchronicity of CMC. On this score, the perspective of Media Synchronicity Theory was taken that had been suggested by criticizing Media Richness Theory. It is the objective, from this perspective, to find which characteristics of networks make the value of IT supporting synchronicity high. In the research trends of social networks, there have been two traditional perspectives to explain the effect of network: embeddedness and diversity ones. These differ from the aspect which type of social network can provide much more economic benefits. As similar studies have been reported by various researchers, these are also divided into the bonding and bridging views which are based on internal and external tie, respectively, Size, density, and centrality were measured as the characteristics of personal task networks. Size means the level of relationship between members. It is the total number of other colleagues who work with a specific member for a certain project. It means, the larger the size of task network, the more the number of coworkers who interact each other through the job. Density is the ratio of the number of relationships arranged actually to the total number of available ones. In an ego-centered network, it is defined as the ratio of the number of relationship made really to the total number of possible ones between members who are actually involved each other. The higher the level of density, the larger the number of projects on which the members collaborate. Centrality means that his/her position is on the exact center of whole network. There are several methods to measure it. In this research, betweenness centrality was adopted among them. It is measured by the position on which one member stands between others in a network. The determinant to raise its level is the shortest geodesic that represents the shortest distance between members. Centrality also indicates the level of role as a broker among others. To verify the hypotheses, we interviewed and surveyed a group of employees of a nationwide financial organization in which a groupware system is used. They were questioned about two CMC applications: MSN with a higher level of synchronicity and email with a lower one. As a result, the larger the size of his/her own task network, the smaller its density and the higher the level of his/her centrality, the higher the level of the effect using the task network with CMC tools. Above all, this positive effect is verified to be much more produced while using CMC applications with higher-level synchronicity. Among the a variety of situations under which the use of CMC gives more benefits, this research is considered as one of rare cases regarding the characteristics of task network as moderators by focusing ITs for the operation of his/her own task network. It is another contribution of this research to prove empirically that the values of information system depend on the social, or comparative, characteristic of time. Though the same amount of time is shared, the social characteristics of users change its value. In addition, it is significant to examine empirically that the ITs with higher-level synchronicity have the positive effect on productivity. Many businesses are worried about the negative effect of synchronous ITs, for their employees are likely to use them for personal social activities. However. this research can help to dismiss the concern against CMC tools.