A Study On Power Factor Correction of SMAW(shielded metal-arc welding) Using Single Phase AC/DC Boost Converter (단상 AC/DC 승압형 컨버터를 이용한 피복 아크 용접기 역률 개선에 관한 연구)

  • Yu Y. J.;Kim L. H.;Kim J. H.;Won C. Y.;Kim Y. R.;Lee S. Y.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.556-559
    • /
    • 2001
  • In this paper, we proposed AC/DC boost converter to improve input current harmonic reduction in SMAW(shielded metal-arc welding). The proposed harmonic reduction with the boost converter design and the UC2854 integrated circuit which controls the converter, The topology of welding power supply is made of a pair of boost converter and welder half-bridge IGBT inverter. The voltage arc is modeled by a variable resistance in series with a voltage source. The results has been confirmed by PSIM simulation tool. The simulation results show that input at current is nearly sinusoidal with low harmonic contents and sinusoidal input current waveform at high power factor.

  • PDF

Three Phase BLDC Motor Drive System using High Efficiency Resonant Boost Converter with Power Factor Correction (역률제어 기능을 갖는 고효율 공진형 컨버터를 이용한 3상 BLDC 전동기 구동 시스템)

  • Lee, Hee-Jun;Park, Sang-Hoon;Park, So-Ri;Won, Chung-Yuen;Jung, Yong-Chae;Kim, Young-Real
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.150-153
    • /
    • 2008
  • This paper presents soft-switching boost converter adding to auxiliary switch and resonant circuit in conventional boost converter. This approach features a two power stage which implements both conventional BLDC motor speed control and input power factor correction. This converter is especially useful in application such as home appliance. Theoretical analysis and simulation results are presented.

  • PDF

Economic Analysis and Comparison between Low-Power and High-Power SOEC Systems (저출력 및 고출력 SOEC 시스템의 경제성 분석 비교)

  • TUANANH BUI;YOUNG SANG KIM;DONG KEUN LEE;KOOK YOUNG AHN;YONGGYUN BAE;SANG MIN LEE
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.6
    • /
    • pp.707-714
    • /
    • 2022
  • Hydrogen production using solid oxide electrolysis cells (SOEC) is a promising technology because of its efficiency, cleanness, and scalability. Especially, high-power SOEC system has received a lot of attention from researchers. This study compared and analyzed the low-power and high-power SOEC system in term of economic. By using revenue requirement method, levelized cost of hydrogen (LCOH) was calculated for comparison. In addition, the sensitivity analysis was performed to determine the dependence of hydrogen cost on input variables. The results indicated that high-power SOEC system is superior to a low-power SOEC system. In the capital cost, the stack cost is dominant in both systems, but the electricity cost is the most contributed factor to the hydrogen cost. If the high-power SOEC system combines with a nuclear power plant, the hydrogen cost can reach 3.65 $/kg when the electricity cost is 3.28 ¢/kWh and the stack cost is assumed to be 574 $/kW.

Design of the Inverter Motor Drive System Applied to PFC using Interleaving Method (인터리빙 PFC를 적용한 모터구동 인버터 시스템 설계)

  • Yoon, Seong-Sik;Choi, Hyun-Eui;Kim, Tae-Woo;Ahn, Ho-Kyun;Park, Seung-Kyu;Yoon, Tae-Sung;Kwak, Gun-Pyoung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.4
    • /
    • pp.14-19
    • /
    • 2010
  • In this paper, using interleaved power factor correction how to improve the inverter efficiency studied. Interleaved method can reduce the conduction losses and the inductor energy. Generally, critical conduction mode (CRM) boost PFC converter used low power level because of the high peak currents. if you use the interleaved mode, CRM PFC can be used medium or high power application. interleaved CRM PFC can reduce current ripple for higher system reliability and size of buck capacitor and EMI filter size. Interleaved CRM PFC that is installed in front of inverter can maintain the constant voltage regardless of the input voltage.

Experimental Study On Power Flow Analysis of Vibration of Various Coupled Plates (다양한 연성 평판 진동에 대한 파워흐름해석법의 실험적 연구)

  • Hwang, S.G.;Kil, H.G.;Lee, G.H.;Lee, J.Y.;Hong, S.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.901-904
    • /
    • 2007
  • The power flow analysis (PFA) can be effectively used to predict structural vibration in medium-to-high frequency ranges. In this paper, vibration experiments have been performed to observe the analytical characteristics of the power flow analysis of the vibration of various coupled plates. Those plates include two plates coupled with angles of $90^{\circ}$\;and\;30^{\circ}$, respectively. In the experiment, the loss factor and the input mobility at a source point on each coupled plate have been measured. The data for the loss factors have been used as the input data to predict the vibration of the coupled plates with PFA. The frequency response functions have been measured over the surface of the coupled plates. The comparison between the experimental results and the predicted PFA results for the frequency response functions has been performed.

  • PDF

Implementation of BOOST Converter with Power Factor Correction(PFC) using a Single-phase On-line UPS (단상 On-line UPS를 이용하여 역율을 개선하는 BOOST 컨버터의 구현)

  • Han, Wan-Ok;Kim, Tae-Woong
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.4
    • /
    • pp.47-52
    • /
    • 1999
  • This paper proposed simplified method to complicated Power Stage with a new On-line UPS scheme by replacing essential battery-voltage booster with a dual-functional PFC. Direct Load Voltage (${V_o}$) can not be applied to high voltage switching converter due to ripple from traditional Power Factor Correction (PFC) but Boost Function of On-line UPS is united so that the cost of system design and development is inexpensive. Through varification of experimental result, proposed UPS scheme shows its performance, low cost and high power density.

  • PDF

Design of a High Efficiency Neon Transformer with Abnormal Load Interrupting Circuit (부하측 이상 검출 차단 장치를 내장한 고효율 자기식 네온 변압기의 설계)

  • Byun Jei-Young;Kim Yoon-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.723-726
    • /
    • 2002
  • In this paper, a high efficiency leakage transformer for neon tube is developed to improve its power factor, to reduce its core loss and weight by using a technique of shape optimization and direction of grain-oriented silicon steel sheet. A protection circuit is designed for all types of neon transformer loaded with one or more neon lamps. Whenever the neon tube fails to be started up or comes to the life end, or encounters faults with open-circuits at the output terminals of the neon transformer, the protection circuit will be initiated to avoid more critical hazards. These neon transformers need a protection circuit to prevent from current stresses on circuit components by neon tube fail. The input of the transformer is automatically cut off when the abnormal condition occurs, preventing waste of no-load power. As the results of the study, the core weight is reduced by $11\%$, the power factor improved by $5\%$ and the efficiency increased by $6\%$ compared with the conventional type due to the employment of the grain-oriented steel sl)eel and the optimized core shape.

  • PDF

High Efficiency AC-DC Converter Using Average-Current Mode Flyback Topology for PDP and Improvement of Hold-up Characteristic (평균전류모드 플라이백 토폴로지를 이용한 PDP용 고효율 AC-DC 컨버터 및 Hold-up 특성 개선)

  • Lee, Kyung-In;Lim, Seung-Beom;Jung, Yong-Min;Oh, Eun-Tae;Lee, Jun-Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.2
    • /
    • pp.23-27
    • /
    • 2008
  • Recently, regulation for THD (Total Harmonic Distortion) such as IEC 61000-3-2, IEEE 519 is being reinforced about a product which directly connects to AC line in order to prevent distortion of common power source in electronic equipment and electrical machinery. In order to satisfy these regulations, conventional circuits were used two-stage structure attached power factor correction circuit at ahead of converter but this method complicate the circuit and then a number of element increases thereupon the cost of production rises. in this paper, we propose a high efficiency single-stage 300W PFC fly-back converter that improved power factor and efficiency than conventional two-stage power module.

  • PDF

High Performance Current Control Algorithm Based on Virtual DQ Synchronous Reference Frame for Single-Phase Boost PFC Converter (단상 부스트 PFC 컨버터용 가상 DQ 동기좌표계 기반 고성능 전류제어 알고리즘)

  • Kim, Hyun-Geun;Jin, Seong-Min;Lee, Sang-Hee;Lee, Su-Hyoung;Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.6
    • /
    • pp.496-503
    • /
    • 2017
  • This study proposes a high-performance current control algorithm for a diode-bridge-type single-phase boost power factor correction (PFC) converter. The conventional asynchronous single-phase current controllers that directly control AC-type current tend to be accompanied by steady-state errors due to their poor dynamic characteristics for the transient-state, which can be attributed to bandwidth limitations and phase delays. In the proposed algorithm, an ideal current control with minimal phase delays and steady-state errors can be achieved by using a virtual DQ synchronous reference frame and by controlling the synchronous reference frame excluding the frequency component in the single-phase system. The performance of the conventional asynchronous single-phase current controller is compared with that of the proposed algorithm through simulation and experiments, and the results have confirmed the superiority of the latter.

The PWM Controlled Cycloconverter with a Resonant Circuit for a Induction Heating (LC공진회로를 이용한 유도가열용 PWM 제어형 사이클로콘버터)

  • Kim, Young-Seok;Kim, Hyun-Jung
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.214-218
    • /
    • 1991
  • This paper presents a PWM controlled cycloconverter with a DC resonant circuit for Induction heating. This cycloconverter converts commercial frequency power to high frequency power directly. So conversion efficiency improved. Controlling a input reactive power regardless of load power, it has sinusoidal input current waveforms as well as a input. displacement factor at 1.