Design of the Inverter Motor Drive System Applied to PFC using Interleaving Method

인터리빙 PFC를 적용한 모터구동 인버터 시스템 설계

  • Received : 2010.01.25
  • Accepted : 2010.02.25
  • Published : 2010.04.01

Abstract

In this paper, using interleaved power factor correction how to improve the inverter efficiency studied. Interleaved method can reduce the conduction losses and the inductor energy. Generally, critical conduction mode (CRM) boost PFC converter used low power level because of the high peak currents. if you use the interleaved mode, CRM PFC can be used medium or high power application. interleaved CRM PFC can reduce current ripple for higher system reliability and size of buck capacitor and EMI filter size. Interleaved CRM PFC that is installed in front of inverter can maintain the constant voltage regardless of the input voltage.

Keywords

References

  1. Miwa, B. A., Otten, D. M. and Schlecht, M. F., "High Efficiency Power Factor Correction using Interleaving Techniques," Proc. IEEE Applied Power Electronics Conf., pp. 557-568, 1992.
  2. Elmore, M. S., "Input Current Rippled Cancellation in Synchronized, Parallel Connected Critically Continuos Boost Converters," Proc. IEEE Applied Power Electronics Conf., Vol. 1, pp. 152-158, 1996.
  3. Ishii, T. and Mizutani, Y., "Power Factor Correction using Interleaving Technique for Critical Mode Switching Converters," Proc. IEEE Applied Power Electronics Specialists Conf., pp. 905-910, 1998.
  4. Michael, O. L., "An Interleaving PFC Pre-Regulator for High-Power Converters," Texas Instruments Power Supply Design Seminar, SEM-1500, 2003.
  5. Tripathi, R. K., Das, S. P. and Dubey, G. K., "Mixedmode operation of boost switch mode rectifier for wide range of load variations," IEEE Trans. Power Electron., Vol. 17, No. 6, pp. 999-1009, 2002. https://doi.org/10.1109/TPEL.2002.805581