• 제목/요약/키워드: High Current Operation

검색결과 1,902건 처리시간 0.034초

정지형 UPS의 병렬운전 제어 (The Parallel Operation Control of Static UPSs)

  • 민병권;원충윤
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권7호
    • /
    • pp.363-368
    • /
    • 1999
  • The parallel operation system of multiple uninterruptible power supplies(UPSs) is used to increase power capacity of the system or to secure higher reliability at critical loads. In the parallel operation of the two UPSs, the load-sharing control to maintain the current balance between them is a key technique. Because a UPS has low output impedance and quick response characteristics, in case of an unbalanced load inverter output current changes very rapidly and thereby can instantaneously reach an overload condition. In this study, high precise load-sharing controller is proposed and implemented for the parallel operation system of two UPSs with low impedance characteristics and this controller controls the frequency and the voltage to minimize the active power component and the reactive power component which are gotten from the current difference between two UPSs. And then a good performance of the proposed method is verified by experiments in the parallel operation system with two 40KVA UPSs.

  • PDF

Fundamental characteristic analysis on 6 T-class high-temperature superconducting no-insulation magnet using turn-distributed equivalent circuit model

  • Liu, Q.;Choia, J.;Sim, K.;Kim, S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.44-48
    • /
    • 2021
  • In order to obtain ultra-high resolution MRI images, research and development of 11 T or higher superconducting magnets have been actively conducted in the world, recently. The high-temperature superconductor (HTS), first discovered in 1986, was very limited in industrial application until mid-2010, despite its high critical current characteristics in the high magnetic field compared to the low-temperature superconductor. This is because HTS magnets were unable to operate stably due to the thermal damage when a quench occurred. With the introduction of no-insulation (NI) HTS magnet winding technology that does not burn electrically, it could be expected that the HTS magnets are dramatically reduced in weight, volume, and cost. In this paper, a 6 T-class NI HTS magnet for basic characteristic analysis was designed, and a distributed equivalent circuit model of the NI coils was configured to analyze the charging current characteristics caused by excitation current, and the charge delay phenomenon and loss were predicted through the development of a simulation model. Additionally, the critical current of the NI HTS magnets was estimated, considering the magnetic field, its angle and temperature with a given current. The loss due to charging delay characteristics was analyzed and the result was shown. It is meaningful to obtain detailed operation technology to secure a stable operation protocol for a 6T NI HTS magnet which is actually manufactured.

교류 전동기의 고효율 운전을 위한 3상 인버터의 입력전력 추정 기법 (Input Power Estimation Method of a Three-phase Inverter for High Efficiency Operation of an AC Motor)

  • 김도현;김상훈
    • 전력전자학회논문지
    • /
    • 제24권6호
    • /
    • pp.445-451
    • /
    • 2019
  • An input power estimation method of a three-phase inverter for the high-efficiency operation of AC motors is proposed. Measuring devices, such as DC link voltage and input current sensors, are required to obtain the input power of the inverter. In the proposed method, the input power of the inverter can be estimated without the input current sensor by using the phase current information of the AC motor and the switching pattern of the inverter. The proposed method is more robust to parameter error than conventional method. The validity of the input power estimation method is verified through experiments conducted on a 1 kW permanent-magnet synchronous motor drive system.

Magnetic and Thermal Analysis of a Water-cooled Permanent Magnet Linear Synchronous Motor

  • Zhang, Xinmin;Lu, Qinfen;Cheng, Chuanying;Ye, Yunyue
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.498-504
    • /
    • 2012
  • The water-cooled Permanent Magnet Linear Synchronous Motor (PMLSM) has a wide range of applications due to high efficiency, high thrust force density and high acceleration. In order to ensure normal operation and maximum output, both the magnetic and thermal performance are vital to be considered. Based on ANSYS software, electromagnetic and thermal finite-element analysis (FEA) models of a 14-pole, 12-slot water-cooled PMLSM are erected adopting suitable assumptions. Firstly, the thrust force and force ripple with different current densities are calculated. Secondly, the influence of different water flow on the motor heat dissipation and force performance under different operationional conditions are investigated and optimized. Furthermore, for continuous operation, the temperature rise and thrust feature are studied under the rated load 8A, the proper temperature $120^{\circ}C$ and the limited temperature $155^{\circ}C$. Likewise, for short-time operation, the maximum duration is calculated when applied with a certain large current. Similarly, for intermittent operation, load time as well as standstill time are determined with the optimal current to achieve better thrust performance.

Three-phase Making Test Method for Common Type Circuit Breaker

  • Ryu, Jung-Hyeon;Choi, Ike-Sun;Kim, Kern-Joong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.778-783
    • /
    • 2012
  • The synthetic short-circuit making test to adequately stress the circuit breaker has been specified as the mandatory test duty in the IEC 62271-100. The purpose of this test is to give the maximum pre-arcing energy during making operation. And this requires the making operation with symmetrical short-circuit current that is established when the breakdown between contact gap occurs near the crest of the applied voltage. Also, if the interrupting chamber of circuit breakers is designed as the type of common enclosure or the operation is made by the gang operated mechanism that three-phase contacts are operated by one common mechanism, three-phase synthetic making test is basically required. Therefore, several testing laboratories have developed and proposed their own test circuits to properly evaluate the breaker performance. With these technical backgrounds, we have developed the new alternative three-phase making circuit.

7상 BLDC 전동기의 고속 운전시 개선된 진상각 보상 연구 (A Study On the Phase Advance Angle of High Speed Operation for 7 Phase BLOC Motor Drives)

  • 김현철;오형식;김장목;김철우
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1930-1936
    • /
    • 2007
  • According to previously published paper the phase advance angle is adopted to the BLDC motor drive with high speed. The report proposed describes the optimum algorism that phase current is in phase with the initial flat region of back EMF. This report studies the need of more leading phase advance angle compared with in phase concept between phase current and back EMF. In case of high reactance this report proposes the more phase advance angle than in phase. The test results more rms value of phase current and output power due to more phase advance angle than in phase. It will be helped the high power operation of BLDC motor at high speed.

유도전동기의 구속운전에 따른 전기 및 발열 특성 연구 (A Study on the Electrical and Heat Generation Characteristics of an Induction Motor under Restrained Operation)

  • 이종찬;김두현;김성철
    • 한국안전학회지
    • /
    • 제38권1호
    • /
    • pp.25-33
    • /
    • 2023
  • In this study, we determined the failure rate and fire status of electric motors widely used in domestic and industrial devices and analyzed the associated fire risks by identifying the electrical and temperature characteristics of electric motors under the normal and restrained operation modes in industrial sites and laboratories. A 2.2kW motor used for driving a conveyor during the vulcanization process in a rubber product manufacturing plant was employed as the study object and was exposed to a high- temperature environment as this motor is widely used in industrial sites. The current amplitude was 4.45-4.50 A during normal operation and 38.2-41.5 A during restrained operation due to the pinching of products and semi-finished products (i.e., 8.5 times higher than that during normal operation). The leakage current amplitude was 0.33 mA during both operation modes. The temperature of the workplace in summer was 42.38℃, indicating a poor environment for the installed motor. In the laboratory, the current and temperature of the coil inside a 3.7kW motor were measured under the restrained operation mode as performing measurements of the coil inside the motor in industrial sites is challenging. The current amplitude during normal operation was 3.5 A, whereas that during restrained operation for 30 s was 51.7-58.6 A, which is 14.8-16.7 times higher than that of normal operation. Moreover, the temperature of the motor coil increased from 22.9℃ to 101℃. Based on the experimental data, we derived the temperature increase formula according to the restrained operation time by performing a regression analysis and verified the time at which the temperature exceeded the stipulated limit for the insulation grade. The findings presented in this paper can be utilized to establish fire-prevention measures and perform safety management of motors of the same type or with a similar capacity.

고압계통 변류기 동작 특성 검토 (A Study on Performance of Current Transformer in High Voltage System)

  • 최기열;이덕수;박문빈;김희택;장기풍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.5-7
    • /
    • 2006
  • Current transformers(CTs) whose rating is selected per a full load current of a feeder in high voltage system can be easily saturated due to high fault current that may be several hundred times of the full load current of the feeder. However, the protective relay shall operate properly at the fault without mis-operation under the CT saturation. So, in selecting the CT rating, it is necessary to consider the behaviour of CT and a performance of protection scheme in condition where CT can be saturated. In this paper, a performance of CT and a degree of saturation are studied and verified whether its ratings are proper for the operation of the protective relay.

  • PDF

High-Performance Metal-Substrate Power Module for Electrical Applications

  • Kim, Jongdae;Oh, Jimin;Yang, Yilsuk
    • ETRI Journal
    • /
    • 제38권4호
    • /
    • pp.645-653
    • /
    • 2016
  • This paper demonstrates the performance of a metal-substrate power module with multiple fabricated chips for a high current electrical application, and evaluates the proposed module using a 1.5-kW sinusoidal brushless direct current (BLDC) motor. Specifically, the power module has a hybrid structure employing a single-layer heat-sink extensible metal board (Al board). A fabricated motor driver IC and trench gate DMOSFET (TDMOSFET) are implemented on the Al board, and the proper heat-sink size was designed under the operating conditions. The fabricated motor driver IC mainly operates as a speed controller under various load conditions, and as a multi-phase gate driver using an N-ch silicon MOSFET high-side drive scheme. A fabricated power TDMOSFET is also included in the fabricated power module for three-phase inverter operation. Using this proposed module, a BLDC motor is operated and evaluated under various pulse load tests, and our module is compared with a commercial MOSFET module in terms of the system efficiency and input current.

인터리브드된 전류 주입형 고승압 DC-DC 컨버터 (Interleaved Current-fed High Step-up DC-DC Converter)

  • 이준호
    • 전기전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.586-591
    • /
    • 2020
  • 본 논문에서는 인터리브된 전류 주입형 고승압 DC-DC 컨버터가 제안된다. 높은 전압 이득 외에도 인터리빙 방식을 채택하여 낮은 리플 입력 전류가 달성된다. 또한 제안 된 컨버터의 소프트 스위칭 특성은 전력 스위치의 스위칭 손실을 줄이고 변환 효율을 높인다. 변압기의 누설 인덕턴스를 활용하여 다이오드의 전류 변화율을 제어함으로써 출력 정류기의 역 회복 문제도 완화된다. 200W 프로토 타입에서 얻은 실험 결과에 대해 설명한다.