• Title/Summary/Keyword: High Altitude Test Facility

Search Result 59, Processing Time 0.02 seconds

Development of Turbo Molecular Pump Vacuum Facility for High Altitude Space Environment Test (고고도 우주환경모사용 터보분자펌프 진공설비 구축)

  • Huh, Hwan-Il;Kim, Min-Jae;Kim, Sung-Su
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.827-829
    • /
    • 2011
  • Vacuum facility is required for high altitude space environment test to develop satellites or space launch vehicles. We, at Chungnam, National University, developed turbo molecular pump vacuum test facility up to $1.0{\times}10-6$ torr to simulate 200 km altitude environment. In this paper, we present some preliminary vacuum performance test results.

  • PDF

Preliminary Design of High Altitude Test Facility for Kick Motor of KSLV-I Development (KSLV-I 킥모터용 고공환경모사 시험설비 구축을 위한 기본설계)

  • Kim, Yong-Wook;Lee, Jung-Ho;Yu, Byung-Il;Kim, Sang-Heon;Oh, Seung-Hyub
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.180-187
    • /
    • 2007
  • Korea Aerospace Research Institute(KARI) is developing Korea Space Launch Vehicle(KSLV). KSLV-I is composed of liquid propulsion system for the first stage and apogee kick motor as the second stage. Kick motor has a high expansion ratio nozzle and its starting altitude is 300km high. To verify the performance of kick motor, high altitude test facility (HATF) to simulate its operating condition is necessary. This paper contains preliminary design for construction of HATF.

  • PDF

An Analysis on Plume Behaviour of Rocket Engine with Ground Condition at High Altitude Engine Test Facility (고공시험설비에서 로켓엔진의 지상시험 플룸 거동 해석)

  • Kim, Seong-Lyong;Lee, SeungJae;Han, YoungMin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.112-115
    • /
    • 2017
  • We analyzed the rocket engine flow to check whether the possibility of the ground test and the equipment safety problems in the high altitude engine test facility. The test condition is that the vacuum chamber is open and the coolant water is injected into the supersonic diffuser. The analysis uses two-dimensional axisymmetry with a mixture of plume, air, and cooling water. As a result, the ground test was possible up to the cooling water flow rate of 200 kg/sec. However, due to the back flow of the initial plume, the vacuum chamber is exposed to high temperature, and at the same time, the inside of the vacuum chamber is contaminated due to the reverse flow of the cooling water. Therefore, sufficient insulation measures and work for pollution avoidance should be preceded.

  • PDF

Performance Test of a Small Simulated High-Altitude Test Facility for a Gas-turbine Combustor (가스터빈 저온/저압 점화장치 구성 및 운영조건 확인 시험)

  • Kim, Tae-Woan;Lee, Yang-Suk;Ko, Young-Sung;Lim, Byeung-Jun;Kim, Hyeong-Mo;Kim, Sun-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.153-156
    • /
    • 2008
  • Ignition and combustion performance of a gas-turbine engine were changed by various high-altitude condition. A goal of this study is to make the small test facility to simulate high-altitude condition. To perform the low pressure condition, a diffuser was used in various diffuser front of primary nozzle pressure. To perform the low temperature, heat exchanger was used in various mixture ratio of cryogenic air and ambient temperature air. The experimental result shows that high-altitude conditions can be controled by diffuser front of primary nozzle pressure and mixture ratio of cryogenic air and ambient temperature air.

  • PDF

Design and Manufacture of Storage Air Heater (축열식 가열기의 설계 및 제작)

  • Lee, Yang-Ji;Kang, Sang-Hun;Park, Poo-Min;Yang, Soo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.43-46
    • /
    • 2006
  • Storage air heater(SAH) is a general purpose facility that is used to simulate the high altitude condition of supersonic ground test facility, thurst compensation test of rocket engine nozzle and gas turbine engine combustor test. SAH in KARI is built to simulate the total temperature of the supersonic ground test facility which has a wide flight envelope from altitude 0km, Mach 2 to altitude 25km, Mach 5 and operates up to 1300K, 3.5MPa. In this paper, we introduces the SAH in JAXA which is model of SAH in KARI and summarizes the design process and manufacture of ours.

  • PDF

Study on the Test Model With/Without of High-Altitude Test Facility for Hypersonic Propulsion (극초음속 추진기관 고공환경 시험장치 모델 유/무에 관한 연구)

  • Lee, Seongmin;Yu, Isang;Park, Jinsoo;Ko, Youngsung;Kim, Sunjin;Na, Jaejeong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.632-636
    • /
    • 2017
  • In this study, we design an altitude test facility for hypersonic propulsion engine by constructing a test facility and cold flow test. Cold flow test is performed both with and without test models. The results show that the facility can simulate almost similar altitude condition without any significant change in pressure regardless of test models. We also constructed a database that might be useful for a variable test in the future.

  • PDF

High Altitude Simulating Test Facility Design Using Vacuum Pump System (진공펌프 시스템을 이용한 고도모의 시험장치 설계)

  • Hong, Yun Ky;Lee, Jung Min;Na, Jae Jung;Hyun, Dong Ki;Kim, Kyeong Su;Park, Sang Hun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1160-1164
    • /
    • 2017
  • In this research, a high altitude simulating test facility is designed using vacuum pump system composed of roots pumps and screw pumps. Air flow rate and chamber pressure are 1 kg/s and 2500 Pa, respectively. To design the test facility, experimental tests using certain pump combinations are performed for air injection of the order of hundreds of g/s. From the tests, it is found that 11 roots pumps and 33 screw pumps are required for the considered test facility. Test results are compared with theoretically estimated values. However, intake capacity theoretically estimated is found to be 20 percent larger than test results. This is thought because of higher pressure difference of roots pump for test conditions. Therefore, if more screw pumps are added for the considered pump system, it would be possible to lower the vacuum level of test chamber.

  • PDF

Study on Configuration Design of Inlet and Exhaust Ducts of a Turboprop Engine for the Altitude Test Considering performance losses (성능손실을 고려한 고고도시험용 터보프롭 엔진 흡입구 및 배기구 형상설계에 관한 연구)

  • Kong, C.;Kim, K.;Lim, S.;Yoo, J.;Choi, K.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.144-152
    • /
    • 2011
  • In order to investigate the operation performance behaviors of the UAV's propulsion system to be operated long time in high altitude, the engine performance tests, which are simulated in the altitude engine test facility should be needed. If the test is performed in a existing altitude engine test facility, additional test apparatuses are required. Among them a proper design of the inlet and exhaust ducts that may directly affect the engine performance is very important. If the design is not adequate, the engine performance loss due to the flow behavior change and the pressure loss may be not similar to the real engine performance. In this work, firstly the engine inlet and exhaust ducts to be mounted to the existing altitude facility are modelled in 3D and its flow behaviors and pressure losses are analyzed using a commercial CFD tool, ANSYS's CFX, and the engine performance with the duct losses is calculated using the performance analysis program developed by C. Kong et al. Finally, the optimized inlet and exhaust ducts' configurations are proposed through the repeated analyses of various duct configurations.

  • PDF

Freejet 타입 램제트 엔진 성능시험기 기본설계

  • Lee, Yang-Ji;Cha, Bong-Jun;Yang, Soo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.65-78
    • /
    • 2004
  • This research was conducted for an acquisition of the ramjet engine test facility design technique which are concerned about freejet type test facility. In this research, we concentrated on the design technique and the construction technique of the vitiation air heater(VAH), test section, diffuser and ejector. Based on the operating modes of the basic test facility, ten operating modes in coordinates "Altitude-Mach number" was regenerated from Mach 2, Altitude 0km to Mach 5, Altitude 15km. In this operating modes, we calculated a design parameter of the supersonic nozzle, VAH, diffuser and ejector and acquired a technique for the ramjet test facility operating and repairing.

  • PDF

The high altitude test method of Scramjet engine combustor model (스크램제트 연소기 모델의 고공시험 연구)

  • Woo Kwan Je;Kim Young Soo;Skivin V. A
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.271-274
    • /
    • 2002
  • This paper is investigated construction of the Scramjet test facility and test method of Scramjet engine combustor model. Scramiet engine combustor model test was performed at Lab C-16BK CIAM (Central Institute of Aviation Motors) at Tyraevo in Moscow. The velocity of flow in the combustion chamber equal to Mach number 2.49 with single hole fuel spray nozzle injector and test duration equal to 7 seconds. Therefore In this paper is showed high altitude test method of Scramjet combustor model and the proper structure of combustor with single hole fuel spray nozzle.

  • PDF