• Title/Summary/Keyword: HgS

Search Result 1,000, Processing Time 0.024 seconds

Contamination Level and Dietary Intake of Total Mercury in Common Restaurant Meals of Seoul Area (서울시내 대중식사중 수은의 오염실태 및 총 섭취량 평가)

  • Lee, Mi-Gyung;Lee, Su-Rae
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.276-282
    • /
    • 1989
  • To investigate the contamination level and total dietary intake of Hg in common restaurant meals of Seoul area, 125 samples of 5 typical meals were collected and determined for their total Hg contents by flameless atomic absorption sepctrophotometry. The average concentrations of Hg were 0.186ppm in drained residues and 0.007ppm in fluids, in which two samples yeukkye-jang and bibim-bab from two sites showed such a high level of 20-30 times of mean values. The average amount of Hg per meal excluding the two samples was $79.6{\mu}g$ and it was not significantly different among different meals. The daily dietary intake of total Hg from 3 restaurant meals was estimated to be $239{\mu}g$, which was 5 times higher than the FAO/WHO limit of $42.9{\mu}g$.

  • PDF

Validation of the mobile wireless digital automatic blood pressure monitor using the cuff pressure oscillometric method, for clinical use and self-management, according to international protocols

  • Yoo, Sooyoung;Baek, Hyunyoung;Doh, Kibbeum;Jeong, Jiyeoun;Ahn, Soyeon;Oh, Il-Young;Kim, Kidong
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.399-404
    • /
    • 2018
  • The purpose of this study was to evaluate the accuracy of a mobile wireless digital automatic blood pressure monitor for clinical use and mobile health (mHealth). In this study, a manual sphygmomanometer and a digital blood pressure monitor were tested in 100 participants in a repetitive and sequential manner to measure blood pressure. The guidelines for measurement used the Korea Food & Drug Administration protocol, which reflects international standards, such as the American National Standard Institution/Association for the Advancement of Medical Instrumentation SP 10: 1992 and the British Hypertension Society protocol. Measurements were generally consistent across observers according to the measured mean ${\pm}SD$, which ranged in $0.1{\pm}2.6mmHg$ for systolic blood pressure (SBP) and $0.5{\pm}2.2mmHg$ for diastolic blood pressure (DBP). For the device and the observer, the difference in average blood pressure (mean${\pm}$SD) was $2.3{\pm}4.7mmHg$ for SBP and $2.0{\pm}4.2mmHg$ for DBP. The SBP and DBP measured in this study showed accurate measurements that satisfied all criteria, including an average difference that did not exceed 5 mmHg and a standard deviation that did not exceed 8 mmHg. The mobile wireless digital blood pressure monitor has the potential for clinical use and managing one's own health.

중금속이온과 포단드와의 착물형성에 관한 연구

  • Choi, Kyu Seong;Kang, Dong Hyun;Kim, Yong Seong;Lee, Shim Sung;Huh, Whang
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.2
    • /
    • pp.131-137
    • /
    • 2001
  • The protonation and stability constants of complexation of Zn(II), Cd(II) and Pb(II), Hg(II) ion with sulfur-containing podand ligands such as tri(phenylthio-2-ethy1)amine (Podand N$_1$S$_3$)tetra(phenylthio-2-ethyl)ethylenediamine (Podand N$_2$S$_4$) , tris(1-benzylaminoethyl)amine (Podand N$_4$) have been determined by potentiometric titration in 95% methanol at variable temperatures, From these studies, we observed that podand N$_4$ ligand showed the largest protonation constant. Protonation constant, stability constant, enthalpy, entropy of Zn(II), Cd(II) and Pb(II), Hg(II),ions increased with the following order podand N$_1$S$_3$$_2$S$_4$$_4$.

  • PDF

Comparison of In Vitro Lipid Deposition and Change of Optical Characteristics on Daily Disposable Lenses (1-day) and 3-days Lenses Over 3 days (3-days lenses와 daily disposable lenses(1-day)의 착용 시간 별 지방 침착량 및 광학적 특성 변화의 비교)

  • Song, Sun Jung;Lee, Su Yeon;Kim, Ki Hong;Chu, Byoung Sun
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.2
    • /
    • pp.67-73
    • /
    • 2020
  • The study aimed to investigate in vitro lipid deposition of oleic acid, oleic acid methyl ester and cholesterol on a daily disposable (1-day lenses) and 3-days lenses over 3 days and changes of optical characteristics is also investigated. Artificial tear solutions were prepared to simulate actual tear compositions. Two types of contact lenses (1-day lenses (Senofilcon A) and 3-days lenses (silicone tripolymer)) were soaked in the artificial tear solutions within an incubator at 37 ℃ with 150 rpm for 8, 16, 24 hours. Lipid deposition (oleic acid, oleic acid methyl ester and cholesterol) were measured using high performance liquid chromatography (HPLC) instrument. In addition, measurements of oxygen transmissibility, light transmittance and observation of lens surface were conducted. The amount of lipid deposition on the 1-day lenses were 127.55 ㎍/lens for Day 1, 302.96 ㎍/lens, for Day 2, and 353.30 ㎍/lens for Day 3. The 3-days lenses were 46.22 ㎍/lens for Day 1, 66.07 ㎍/lens for Day 2, and 67.45 ㎍/lens for Day 3. Oxygen transmissibility were 81×10-9(cm/sec)(ml O2/ml×mmHg)(Baseline) and 48×10-9(cm/sec)(ml O2/ml×mmHg) (Day 3) for the 1-day lenses, it were 13.23×10-9(cm/sec)(ml O2/ml×mmHg)(Baseline) and 9.6×10-9(cm/sec)(ml O2/ml×mmHg) (Day 3) for the 3-days lenses. Transmittance of each lenses were 97.21% (Baseline) and 94.25% (Day 3) for the 1-day lenses, 97.65% (Baseline) and 95.15% (Day 3) for the 3-days lenses. Observation of surface deposition indicated greatest deposition for the 3-days lenses type on Day 3. Lipid deposition for both lens types increased by day and was greater for the 1-day lenses type. Surface deposition appeared to differ as it was greatest for the 3 days lens type, which may suggest other deposits such as protein may be present.

Concentration of Heavy Metals in Seawater, Fish, and Shellfish at Lake Shihwa (시화호 내 수질 및 어패류의 중금속 분포 연구)

  • Lee, Gyuyoung;Lee, Seunghun;Oh, Sehun;Choi, Minji;Lee, Yong-Woo
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.2
    • /
    • pp.157-163
    • /
    • 2018
  • This study aims to determine the pollution levels of nine kinds of heavy metals (As, Cd, Cu, Cr, Hg, Mn, Ni, Pb, and Zn) in Lake Shihwa, which is susceptible to the inflow of pollutants, and the levels of heavy metal exposure in its fish and shellfish. Shihwa Lake's water quality did not exceed the short-term standard for protection of marine ecosystems, but concentrations of As, Cu, Cr, Hg, Ni, and Zn exceeded the long-term standard for protection of a marine ecosystem. In comparison to findings in prior research, performed in 2010, levels of Cr, Ni, As, and Zn are now 4.1 times lower. However, when compared to Saemangeum Lake, the environment is similar to that of Lake Shihwa, Cu, Ni, Hg, Mn, and Zn were 244.4 times higher. The levels of Pb, Cd, and Hg in fish's muscles did not exceed the average values set by the marine safety standard. However, when compared to the fish from the Korean coast, the levels of heavy metals were 9.7 times higher, on average. The levels of heavy metals in fish's livers were on average 26.8 times higher than in the muscles. In the case of shellfish, the levels of Pb, Cd, and Hg did not exceed the standard values, but in comparison to the shellfish from the south coast, the levels of heavy metals were 6.2 times higher on average. In particular, Mn (153.5 times higher) from fish and Cd (14.7 times higher) from shellfish were found in high amounts, indicating a concerning level of these specific heavy metals.

Comparison of Adverse Events between High-intensity and Moderate- to Low-intensity Statin Group (의약품부작용보고시스템 데이터베이스를 이용한 고강도 statin과 중·저강도 statin 관련 이상사례 비교 분석)

  • Lee, Sera;Ock, Miyoung;Kim, Hyunah
    • Korean Journal of Clinical Pharmacy
    • /
    • v.28 no.4
    • /
    • pp.293-299
    • /
    • 2018
  • Background: 3-Hydroxy-3-methylglutaryl coenzyme A reductase inhibitors (statins) effectively reduce serum levels of low-density lipoprotein (LDL) and total cholesterol. High-intensity statins are recommended for all patients aged ${\leq}75$ with clinical atherosclerotic cardiovascular disease (ASCVD), diabetes mellitus aged 40-75 with ${\geq}7.5%$ estimated 10-year ASCVD risk and LDL-C ${\geq}190mg/dL$. High-intensity statins associated with more frequent adverse events (AEs) compared to moderate- to low-intensity statins. The aim of this study was to compare AEs between high-intensity and moderate- to low-intensity statin group using the Korea Adverse Event Reporting System (KAERS) database. Methods: Adults (${\geq}18years$) with statin-associated AEs from July 2009-June 2014 were included. Only AEs classified as "certain", "probable" and "possible" based on the WHO-Uppsala Monitoring Center criteria were analyzed. Results: In total, 247 AEs from 196 patients [high-intensity statin group (HG), n = 25 (13%); moderate- to low-intensity statin group (MLG), n = 171 (87%)] were included. Mean age was higher in HG compared with MLG ($67{\pm}14$ vs $62{\pm}12$). The HG showed a significant higher frequency of liver/biliary system disorders (37% vs 14%, p = 0.001). Hepatic function abnormal was reported more frequently in HG compared to MLG (26% vs 9%, p = 0.006). Conclusion: According to KAERS data, liver/biliary system disorders were more frequently reported in HG compared to MLG.

Numerical analysis of HgCdTe heterojunction photodiodes (HgCdTe 이종접합 광다이오드의 수치 해석)

  • 조남홍;곽규달
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.7
    • /
    • pp.45-55
    • /
    • 1997
  • Electircal characteristics of HgCdTe photodiodes with a heterostructure to achieve high performance are analyzed numerically. A two-dimensional device simulator which can handle a HgCdTe heterostructure, was developed for this work. The effects of band nonparabolicity, carrier degeneracy, and band-offset of heterointerace are included in a carrier transport model. A unified generation-recombination model includes simultaneously phonon-assisted tunneling and pure tunneling of carriers via traps is newly employed for describing the electric field and temperature dependency of dark current effectively. Furthermore, to accurately predict the effect mole fraction variations on genration rates, ray-trace algorithm is incorporated in the our simulator. Under the various circumstances such as dark, illumination, and surface states, electrical properties of planar heterostructure photodiode are presented and those of homojunction are compared. These results serve as a explanation of cap layer's role on performance.

  • PDF

Emulsion Liquid Membrane Transport of Heavy Metal Sons by Macrocyclic Carriers (거대고리 운반체에 의한 중금속이온의 에멀죤 액체막 수송)

  • 정오진
    • Journal of Environmental Science International
    • /
    • v.4 no.2
    • /
    • pp.223-232
    • /
    • 1995
  • New two macrocyclic compounds using as carriers of liquid emulsion menbrame, have been synthesized. These reuslts provide evidance for the usefulness of the theory in designing the systems. The efficiency of selective transport for heavy metal ions have been discussed from the membrane systems that make use of $SCN^-$,<>,$I^-$,CN- and $Cl^-$ ion as co-anions in source phase and make use of $S_2O_3^{2-}$ and $P_2O_7^{4-}$ ion as receiving phase, respectively. The transport rate of M(II) was highest when a maximum amount of the M(II) in the source phase was present as$Cd(SCN)_2$$(P[SCN^-]= 0.40M)$, $Hg(SCN)_2([SCN^-]=0.40M)$ and Pd(CN)$([CN^-]= 0.40M)$. The Cd(II) and Pb(II) over each competitive cations were well transprted with 0.3M-S2032- and 0.3M-P2O74-, respectively in the receiving phase. Results of this study indicate that two criteria must be met in order to have effective macrocycle-mediated transport in these emulsion system. First one must effective extraction of the $M^{n+}$ into the toluene systems. The effectiveness of this extraction is the greatest if locK for $M^{n+}$macrocycle interaction is large and if the macrocycle is very insoluble in the aqueous phase. Second, the ratio of the locK values (or Mn+-receiving phase ($S_2O_3^{2-}$- or $P_2O_7^{4-}$) to $M^{n+}$-macrocycle (($L_1$이나 $L_2$) interaction must be large enough to ensure quantitative stripping of Mn+(($Cd^{2+}$,$Pb^{2+}$)at the toluene receiving Phase interface. $L_1$(3.5-benzo-10,13,18,21-tetraoxa-1,7,diazabicyclo(8,5,5) eicosan) forms a stable ($Cd^{2+}$ and >,$Pb^{2+}$ complexes and $L_1$ is very insoluble in water and its $Cd^{2+}$ and >,$Pb^{2+}$ complex is considerably less stable than $Cd^{2+}$-(S2O3)22- and $Pd^{2+}-P_2O_7^{4-}$ complexes. On the other hand, the stability of the $Hg^{2+}$)+-$L_1$( complex exceed that of the $Hg^{2+}$- (S2O3)22- and Hg2+-P2O74-, and the distribution coefficient of $L_2$(5,8,15,18,23,26-hexaoxa-1,12- diazabicyclo-(10,8,8) octacosane) is much smaller than that of $L_1$. Therefore, the partitioning of Lr is favored by the aqueous receiving Phase, and little heavy metal ions transport is seen despite the large logK for $Hg^{2+}$+-$L_1$ and $Mn^+$($Cd^{2+}$+, $Pb^{2+}$+ and $Hg^{2+}$)-$L_2$ interactions. Key Words : macrocycles, transport, heavy metal, co-anion, source phase, receiveing, complex separation, interaction, destribution coefficient.

  • PDF

Time-synchronized measurement and cyclic analysis of ultrasound imaging from blood with blood pressure in the mock pulsatile blood circulation system (박동 혈액 순환 모의 시스템에서 시간 동기화된 혈압 및 혈액의 초음파 영상 측정 및 주기적 분석)

  • Min, Soohong;Jin, Changzhu;Paeng, Dong-Guk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.361-369
    • /
    • 2017
  • Hemodynamic information in the carotid artery bifurcation is very important for understanding the development and progression mechanisms of cerebrovascular disease and for its early diagnosis and prediction of the progress. In this paper, we constructed a mock pulsatile blood circulation system using an anthropomorphic elastic vessel of the carotid artery bifurcation and ex vivo pig blood to acquire ultrasound images from blood and vessels synchronized with internal pressure while controlling the blood flow. Echogenicity, blood flow velocity, and blood vessel wall motion from the ultrasound images, and internal blood pressure were extracted over a cycle averaged from five cycles when the pulsatile pump rates are 20 r/min, 40 r/min, and 60 r/min. As a result, respectively, the peak systolic blood flow velocities were 20 cm/s, 25 cm/s, and 40 cm/s, the blood pressure differences were 30 mmHg, 70 mmHg, and 85 mmHg, the arterial walls were expanded to 0.05 mm, 0.15 mm, and 0.25 mm. Time-delayed cyclic variation of echogenicity compared to blood flow and pressure was observed, but the variation was minimal at 20 r/min. Time-synchronized cyclic variations of these parameters are important information for accurate input parameters and validation of the computational hemodynamic experiments which will provide useful information for the development and progress mechanisms of carotid artery stenosis.

Optimal Cutoff Points of Rate Pressure Product in Each Stage of Treadmill Exercise Test According to the Degree of Metabolic Syndrome in Korean Adults (한국성인의 대사증후군 예방을 위한 운동부하 검사시 각 단계별 심근부담률의 적정 임계점)

  • Shin, Kyung-A
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.2
    • /
    • pp.136-143
    • /
    • 2018
  • The rate pressure product (RPP) is expressed as a product of the heart rate and systolic blood pressure as an index indirectly measuring the myocardial oxygen consumption, and it indicates the burden on the myocardium. The aim of this study was to determine the optimal level of RPP for preventing metabolic syndrome in a treadmill exercise test in Korean adults. Metabolic syndrome was the diagnosis of the third executive summary report on the National Cholesterol Education Program Adult Treatment Panel III (NCEP-ATP III) criteria. According to the criteria, the metabolic syndrome diagnosis group (MetS, N=25), pre-metabolic syndrome group (Pre-MetS, N=106), and non-risk factor group (Non-MetS, N=65) were classified. The exercise stress test was performed based on the Bruce protocol. The RPP was calculated as (heart rate${\times}$systolic blood pressure)${\div}1,000$. The results showed that the maximum systolic blood pressure was high despite the low daily dose reached in the diagnostic group of metabolic syndrome. The optimal threshold of the RPP at the time of the exercise treadmill test for a metabolic syndrome prediction was $12.56mmHg{\times}beats/min{\times}10^{-3}$ in the first stage of the exercise stress test. The second stage of the exercise test was $16.94mmHg{\times}beats/min{\times}10^{-3}$, and at the third stage of the exercise test was $21.11mmHg{\times}beats/min{\times}10^{-3}$.