• 제목/요약/키워드: Hemodynamic study

검색결과 429건 처리시간 0.024초

동물에서의 심장동종이식에 관한 실험 (Experiment for Animal Heart Transplantation)

  • 서경필
    • Journal of Chest Surgery
    • /
    • 제22권1호
    • /
    • pp.1-9
    • /
    • 1989
  • We have performed one case of autotransplantation and 11 cases of orthotopic homotransplantation using Korean mongrel dogs, and have scrutinized the hematologic and hemodynamic results. The mean weight of recipients was 15.42*1.2kg and varied from 14kg to 20kg. During the operation, anesthesia and other technical procedures including cardiopulmonary bypass were similar to the usual methods in human cardiac transplantation. It was found that the hematologic values were similar to those of human beings although there was wide variance. Hemodynamically the mean systolic and diastolic arterial pressures were 165.0* 12.9 mmHg and 100.0 *11.8 mmHg respectively, and the mean heart rate was 155.5*23.5/min. All cases died within 24hrs, and the mean survival in all but 6 cases where operative death occurred was 6.83*8.01 hrs[range 2-21 hrs]. The major causes of deaths were bleedings in 7 cases, failure to protect myocardium during the procedure in 2 cases, pulmonary edema in 1 case and multiorgan failure in 2 cases. From the above results we concluded that the most frequent complication was bleeding, and the cardiopulmonary bypass flow of 50-500ml/kg min was not suitable to the dog in CPB. In further experiment after this study, the technical and the bypass flow was increased. Bleeding was not significant. And the immunosuppresion during operation and postoperative period was tried.

  • PDF

Flow Dynamics Near End-To-End Anastomoses - Part I. In Vitro Compliance Measurement -

  • Kim, Y.H
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권2호
    • /
    • pp.165-174
    • /
    • 1992
  • Compliance mismatch across an end-to-end anastomosis was measured In the In vitro experimental setup. A 35mm camera was used and Image process was done in Gould/ DeAnza Image processor. The results showed that compliances of Penrose tubing and synthetic PTFE grafts were In good agreement with the previously reported In vivo data. PTFE grafts exhibited a nonlinear behavior with compliance decreasing with Increasing transmural pressure, whereas the compliance of the Penrose tubing remained relatively constant within the range of the pressures in which data were obtained. The lumen cross sections at the anastomosis were affected by the suture and the mismatch In compliance between the Penrose tubing and vascular grafts. The varla~lons In the lumen dtameter at the anastomosis was more pronounced with increasing transmural pressures. From the present study, it was clearly demonstrated that the compliance of prosthetic grafts Is much lower than that of the arteries. In addition to the hemodynamlc consequences, compliance mismatch across the anastomosis has been known to lead to Increased anastomotlc and suture stresses with resultant suture line dehlscence and false aneurysm formation. Thus, there are good hemodynamic reasons to suppose that Introduction of a less compliant arterial graft Into the arterial circulation wlll be damaging and that grafts should be made to match the elastic behavior of their host arteries as closely possible.

  • PDF

노인 외상 환자에 대한 분석 및 외상성 혈기흉의 임상양상 (Clinical Analysis of Old-aged Chest Trauma Patient and Traumatic Hemopneumothorax)

  • 김정태
    • Journal of Trauma and Injury
    • /
    • 제22권2호
    • /
    • pp.161-166
    • /
    • 2009
  • Purpose: This study was conducted to analyze chest-trauma patients and the old-aged patients with a traumatic hemopneumothorax. Methods: We reviewed the medical records of 101 chest-trauma patients admitted to the department of cardiovascular and thoracic surgery from June 1999 to November 2008. We evaluated the general characteristics of the chest-trauma patient, especially those of old-aged patients with a traumatic hemopneumothorax. Results: Rib fracture was observed in 99 of the cases, the location distribution was right: left =261: 255, with right being dominant. Rib fractures commonly involved the 4th and the 7th rib. The average number of rib fractures was 5.1, and the average number of rib fractures in the old-aged patients was significantly higher than that in the non-old-aged patients (p=0.04). There were 17 cases of a hemopnuemothorax in old-aged patients, 52 cases in non-old-aged patients. The blood loss through the chest tube for old-aged patients was significantly more than that for the non-old-aged patients, and the initial hemoglobin level was lower in the old-aged patients. Conclusion: Elderly trauma patients are more likely to die after trauma than other age groups. Even with relatively stable vital signs, invasive hemodynamic monitoring and intensive treatment are recommended.

${\alpha}_2-Adrenergic$ Receptor 차단제인 Idazoxan의 신장작용 (Renal Action of Idazoxan, ${\alpha}_2-Adrenergic$ Antagonist, in Dog)

  • 고석태;강경원
    • Biomolecules & Therapeutics
    • /
    • 제8권2호
    • /
    • pp.132-139
    • /
    • 2000
  • This study was performed far investigation of influence on renal function of idazoxan, $\alpha_{2}$-adrenergic antagonist, using the dog. Idazoxan, when giver. into vein, produced the decrease of urine volume(vol) accompanied with the reduction of free water clearance($C_{H2O}$), amounts of sodium excreted in urine($E_{Na}$), with the increase of potassium excreted in urine($E_{K}$), and so ratios of potassium against sodium($K^{+}/Na^{+}$) were elevated, at this time, greatened reabsorption rate of sodium and diministered that of potassium in renal tubules were appeared. Idazoxan administered into a renal artery elicited the augmentation of vol, glomerular filtration rate(GFR), renal plasma flow(RPF) and no change of filtration fraction(FF) in only ipsilateral kidney, whereas $E_{Na},\;E_{K}\;and\;K^{+}/Na^{+}$ were increased and $C_{H2O}$ was decreased in both control and experimental kidney. Idazoxan given into carotid artery showed partial increased vol, remarkable expanded RPF and unchanged GFR, and so filtration fraction(FF) was markedly reduced. Above results suggest that anti- diuretic action of idazoxan given into vein is mediated by reduction of $C_{H2O}\;and\;E_{Na}$, diuretic action only in the ipsilateral kidney by idazoxan given into a renal artery is caused by hemodynamic improvement through expansion of vas afferens in glomeruli.

  • PDF

협 부가 있는 동맥 내부에서의 맥동유동 (Pulsatile Flow in the Artery with Stenosis)

  • 손정락;주상우;서상호;심은보
    • 대한기계학회논문집B
    • /
    • 제26권1호
    • /
    • pp.39-44
    • /
    • 2002
  • The arterial stenosis related to the intimal thickening of the arterial wall is the main cause of many diseases in human cardiovascular system. Hemodynamic behavior of the blood flow is influenced by the presence of the arterial stenosis. In this study, effects of the pulsatile flow, caused by the periodic motion of the heart, on the blood flow and its interaction with the arterial stenosis are analyzed by the FEM-based computational fluid dynamics. As a result, it was found that the characteristics of the pulsatile flow in the artery with stenosis are quite different from those of the steady flow. And, the pulsatile flow condition affects the wall shear stress, which is one of the most important physiological parameters in the hemodynamics.

마그네슘 농도변화에 따른 흰쥐의 심근 보호효과 (Protective Effect on the Rat's Myocardium with Changes in Magnesium Concentrations)

  • 홍치욱;조규석;유세영
    • Journal of Chest Surgery
    • /
    • 제30권1호
    • /
    • pp.11-16
    • /
    • 1997
  • The Increasing use of coronary perfusates for the protection of the human heart during ischemic cardiac arrest has placed great emphasis on the need for a rational and safe formulation. For the purpose of this study isolated rat hearts were connected to retrograde nonworking perfusion system proposed by Langendorff, and then perfused for 20 minutes by coronary infusates of magnesium concentration of 1.66 m Mol per liter(group A, n: 10) or 15mMo1 per liter(group B, n: 10). After 20 minutes perfusion, cold cardioplegic solution (modified St. Thomas'Hospital solution) was infused for 2 minutes, and prepared within 4$^{\circ}C$ Krebs-Henseleit solution. Finally, 20 minutes of cononay reprsfuslon was reestablished after I hour of cold ischemic cardiac arrest. Hemodynamic parameters (heart rate, left ventricular pressure, $\pm$ dp/dt max. and coronany flow) and enzymes assay (creatine phosphokinase, lactic dehydrogenase and flutamic oxaloacetic transaminase) were performed each other at whic rat heart was perfused for 20 minutes and reperfused for 20 minutes thereafter. There were significant differences in the recovery rate of heart rate, systolic left ventricular pressure, + dp/dt max, and coronary flow and reperfusion-perfusion ratio of creatine phosphokinase(P < 0.05). But, there were no signicant differences in the recovery rate of dp/dt max, and reperfunion-perfusion ratio of lactic dehydrogenase and glutamic oxaloacetic acid (P > 0.05).

  • PDF

만성 수축성 심낭염의 임상적 고찰 (A Study of Chronic Constrictive Pericarditis)

  • 김현경
    • Journal of Chest Surgery
    • /
    • 제24권10호
    • /
    • pp.973-978
    • /
    • 1991
  • From January, 1982, to December, 1990, 15 patients underwent pericardiectomy for chronic constrictive pericarditis on Department Of Thoracic and Cardiovascular Surgery, School of Medicine, Pusan National University. There were 9 male and 6 female patients [male to female ratio was 1.5: 1] ranging from 15 years to 63 years old [mean age 35.0]. All patients underwent pericardiectomy through a median sternotomy, partial cardiopulmonary bypass was performed on two patients. There were 3 postoperative death [20%]. Six cases [40%] were tuberculous origin 5 cases [34%] were Idiopathic [nonspecific chronic inflammatory change was considered to idiopathic], 2 cases [13%] were malignant origin, 2 cases [13Yo] were pyogenic origin. Dyspnea on exertion was evident in all patients and abdominal distention, general weakness, palpitation, peripheral edema were found. Eleven patients showed low voltage of QRS wave, 7 patients showed diffuse ST-T wave change, 2 patients showed atrial fibrillation on EKG. There were 6 patient showed pericardial thickening, 5 patients showed evidence of restriction, 5 patients showed pericardial effusion, 4 patients showed low cardiac output on preoperative echocardiogram. Hemodynamic response to pericardiectomy were observed; preoperative CVP 26.8 cmH2O declined to 15.0 cmH2O. Preoperative NYHA Functional class showed class II - 1, class III - 10, class IV - 4, postoperative NYHA functional class showed class I - 7, class II - 4, class Ill - l.

  • PDF

신생아에 있어 TcB[transcutaneous bilirubinometry]를 이용한 고빌리루빈혈증의 사정 (Assessment of Neonatal Hyperbilirubinemia Using a Transcutas Bilirubinometry)

  • 안영미;김미란;이상미;전용훈
    • 대한간호학회지
    • /
    • 제33권1호
    • /
    • pp.51-59
    • /
    • 2003
  • Purpose: The purpose of the study is to investigate the relationship between total serum bilirubin(TSB) and transcutaneous bilirubinometry(TcB) in neonates with jaundice. Method: TcB from various sites(forehead, sternum, abdomen, buttock, hand, dorsalis-pedia) was measured using a JM-102 in a total of 102 neonate, 42 female and 60 male, with the mean 37.5 gestational week and the mean 2,903 gram of birth weight, as well as TSB from capillary punctures. Result: The mean bilirubin was 11.73 in serum, 20.55 on the forehead, 17.23 on the sternum, 16.19 on the abdomen, 18.22 on the buttock, 15.83 on the hand and 15.49 on the dorsalis-pedia. The relationship between TSB and TcBs were formulated by simple regression with 0.406 < r < 0.668(p < .000). A higher relationship was revealed between TSB and TCB at the forehead in infants of full-term, ABO incompatibility, and Hb greater than 16 mg/dl(r =0.725, 0.790, and 0.717, retrospectively). Phototherapy altered the measurement of TcB per site. Conclusion: TcB on the forehead is a reliable, noninvasive and convenient measurement of TSB in normal infants(Institutions need to establish quantitative equations representing the specific relationship between TSB and TCB according to the hemodynamic problems of infants such as ABO incompatibility, or low Hb).

심장내과 병동의 텔레메트리 적용 환자 특성 (Characteristics of Patients Undergoing Telemetry in the Cardiology Ward)

  • 김윤선;최혜란
    • 중환자간호학회지
    • /
    • 제7권2호
    • /
    • pp.14-23
    • /
    • 2014
  • Purpose: The purpose of this study was to provide basic information to develop appropriate nursing guidelines for cardiac telemetry. Methods: This retrospective research was conducted to identify the current usage of cardiac telemetry and considered 1,000 patients hospitalized for telemetry. The collected data were analyzed using IBM (SPSS Statistics for Windows 21.0). Results: Four-hundred and ninety-two patients (49.2%) were diagnosed with arrhythmia and 209 (20.9%) with heart failure. Electrocardiogram (ECG) rhythm changes were detected via telemetry in 464 cases. Major arrhythmias were ventricular tachycardia (183, 39.4%) and bradycardia (99, 21.3%). Interventions after detecting arrhythmia were cardioversion (16, 3.4%), defibrillation (1, 0.2%), and cardiopulmonary cerebral resuscitation (5, 1.1%); other patients were treated conservatively with close observation (381, 82.1%). Conclusion: There was appropriate intervention in 46.4% of the considered cases with the detection of ECG changes before patient notification, which implied that cardiac telemetry could be considered for application to patients with hemodynamic instability. Clear standards and guidelines are required to determine who requires telemetry and when to end the telemetry monitoring.

  • PDF

Application of Functional Near-Infrared Spectroscopy to the Study of Brain Function in Humans and Animal Models

  • Kim, Hak Yeong;Seo, Kain;Jeon, Hong Jin;Lee, Unjoo;Lee, Hyosang
    • Molecules and Cells
    • /
    • 제40권8호
    • /
    • pp.523-532
    • /
    • 2017
  • Functional near-infrared spectroscopy (fNIRS) is a noninvasive optical imaging technique that indirectly assesses neuronal activity by measuring changes in oxygenated and deoxygenated hemoglobin in tissues using near-infrared light. fNIRS has been used not only to investigate cortical activity in healthy human subjects and animals but also to reveal abnormalities in brain function in patients suffering from neurological and psychiatric disorders and in animals that exhibit disease conditions. Because of its safety, quietness, resistance to motion artifacts, and portability, fNIRS has become a tool to complement conventional imaging techniques in measuring hemodynamic responses while a subject performs diverse cognitive and behavioral tasks in test settings that are more ecologically relevant and involve social interaction. In this review, we introduce the basic principles of fNIRS and discuss the application of this technique in human and animal studies.