A Study on Relationship Insulation Thickness and Infiltration Load by Window (단열재 두께 변화와 창호 침기 부하와의 관계)

  • Choi, Jeong-Min;Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.422-427
    • /
    • 2012
  • This study investigates on the relationship between total load which is caused by infiltration and insulation thickness against compensation effect. As the result of experiment, the PVC(Synthetic resins sash) window frame in airtightness is superior to the AL(Aluminum sash) window frame. In this study, as the increasing of insulation thickness in reference building does not reduce significantly cooling load, the compensation effect due to airtightness against infiltration is very small. But the compensation effect against infiltration can be closely related with heating load. Therefore, the proper thermal insulation thickness can be needed respect to cooling and heating load.

Internet-Based Control and Monitoring System Using LonWorks Fieldbus for HVAC Application

  • Hong, Won-Pyo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1205-1210
    • /
    • 2004
  • The 4-20mA analog signal used in the various industrial fields to interface sensor in distributed process control has been replaced with relatively simple digital networks, called "fieldbus, and recently by Ethernet. Significant advances in Internet and computer technology have made it possible to develop an Internet based control, monitoring, and operation scheduling system for heating, ventilation and air-conditioning (HVAC) systems. The seamless integration of data networks with control networks allows access to any control point from anywhere. Field compatible field devices become so-called "smart" devices, capable of executing simple control, diagnostic and maintenance functions and providing bidirectional serial communication to higher level controller. The most important HVAC of BAS has received nationwide attention because of higher portion of more than 40% in building sector energy use and limited resources. This paper presents the Internet-based monitoring and control architecture and development of LonWorks control modules for AHU (air handling units) of HVAC in viewpoint of configuring BAS network. This article addresses issues in architecture section, electronics, embedded processors and software, and internet technologies.

  • PDF

Effect of Desiccant and Channel Geometries on the Performance of Desiccant Rotor (제습제와 채널이 제습로터 성능에 미치는 영향)

  • Chung, Jae-Dong;Lee, Dae-Young;Yoon, Seok-Mann
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.8
    • /
    • pp.569-576
    • /
    • 2007
  • The desiccant rotor is the most essential component of desiccant cooling system, but one of its drawbacks to spread out is rotor size. To reduce the size of rotor the analysis of rotor performance is crucial. Systematic examination on the effect of desiccant and channel geometries has been conducted based on the numerical program previously developed. Considered parameters related to channel geometries are channel shape and cross section area of channel, and parameters related to desiccant are mass fraction, heat capacity, density, maximum water uptake and separation factor of isotherm. Considerable reduction of rotor size is expected by adjusting the parameters.

Experimental Studies on the Performance of a Transcritical Cycle for Hot Water Heating Using Carbon Dioxide (이산화탄소를 이용한 온수급탕용 초월임계사이클의 성능에 대한 실험적 연구)

  • 김성구;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.461-470
    • /
    • 2003
  • The purpose of this study is to investigate the performance of a transcritical cycle for hot water heating using $CO_2$ as a working fluid. Some of the main parameters that affect the practical performance of the $CO_2$ system are discussed; the performance on the variation of refrigerant charge, changes in flow conditions of secondary fluids, and that with or without internal heat exchanger, The experimental results show that the optimum charge is approximately the same for various mass flow rates of the secondary fluid at gas cooler. The experimental results on the effect of secondary fluids are in general agreement with the experimental results of transcritical cycle in the open literature and show similar trend for conventional subcritical vapor compression cycles. The heat exchanger effectiveness increases with an increase of the heat exchange area of the internal heat exchanger regardless of the mass flow rate at the gas cooler.

A Study on Optimization Development of Peltier Air-conditioning System (펠티어 냉난방시스템 최적화 기술에 관한 연구)

  • Park, Sanghoon;Jeong, Soojin;Park, Youngwoo;Park, Ukyung;Song, Beomjung
    • Journal of Institute of Convergence Technology
    • /
    • v.3 no.1
    • /
    • pp.19-23
    • /
    • 2013
  • This study is concerned with air-conditioning system in use of thermoelectric device. It is introduced that the well designed structures for better cooling & heating performance with high efficiency. And also it is performed that the system performance test of four types trial products for the use of hybrid commercial vehicle. System performance is affected by many component parts, especially heat sink design & power control method. It is applied that dual extrusive fin tube with buffer zone for the effective radiating of circulating liquid in tube. And also it is applied that power supply method with constant-current system. It is attained that system cooling capacity is 1.2kW, COP is 0.95.

  • PDF

A Controller Design of the Bilinear System for HVAC(Heating, Ventilating and Air-conditioning) System (냉난방 시스템의 이중선형 시스템에 관한 제어기 설계)

  • 이정석;강민수;김명호;이기서
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.4
    • /
    • pp.177-184
    • /
    • 2000
  • In this paper, a HVAC controller which has a bilinear system is designed to control the air temperature in building room and a saving of energy on the HVAC system. For modeling of the HVAC bilinear system, AHU(Air Handling Unit) is modeled on the control of inside-outside air flow using three dampers in a duct. A heat exchanger and the single room are also modeled by the energy conservation law. Under the modeling of the HVAC bilinear system, the control's law of the bilinear HVAC system is derived by Lyapunov's non-linear theory and Deress's the linear feedback laws for bilinear system. In this paper it was proved that the controller of the HVAC bilinear system is able to control the air temperature with a disturbance in order to get a target of temperature in the building room by the computer simulation when the control inputs regulate the air flow rate and a capacity of the heat exchanger.

  • PDF

Simulation of the Thermal Performance on an Ondol House with Hot Water Heating in Consideration of Radiation Heat Transfer (복사열전달을 고려한 모형 온수온돌 주택 열성능 시뮬레이션)

  • Choi, Y.D.;Yoon, J.H.;Hong, J.K.;Lee, N.H.;Kang, D.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.295-305
    • /
    • 1993
  • Thermal performance of test cell of model hot water Ondol house was simulated by equivalence heat resistence and heat capacity method. In this method wall was replaced by two equivalence and one heat capacity. This method enables to simulate the variation of temperature of each element of model house. The effect of pipe diameter, pitch of pipe and with or without consideration of inter-radiation between wall surfaces on the energy consumption rate were investgated. Results show that radiations between the ground surface of room and wall surfaces contribute to the heating of room air by reducing the convection heat loss through the wall surfaces.

  • PDF

A Second-Order Analysis of VM Heat Pumps (VM열펌프의 2차해석)

  • Choi, Y.S.;Jeong, E.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.208-218
    • /
    • 1996
  • Performance of a VM heat pump is considerably affected by various losses, such as enthalpy dump, reheat loss, pumping loss, conduction loss and shuttle loss. A second-order analysis model of VM heat pumps, which allows consideration of the major losses, was presented. Actual heat transfer rates for heat exchangers were calculated from the heat transfer rates obtained by the adiabatic analysis and various losses. New effective temperatures of heat exchangers were calculated from the actual heat transfer rates and the mean heat transfer coefficients until there was no appreciable change in the effective temperatures. Effects of design parameters, such as phase angle, swept volume ratio, regenerator length and speed on heating capacity, cooling capacity and COP were shown.

  • PDF

Intelligent Digital Control of Heating, Ventilating, and Air Conditioning System for Smart Space (스마트 스페이스를 위한 난방, 환기 및 공기조화 시스템의 지능형 디지털 제어)

  • Kim, Do-Wan;Park, Jin-Bae;Joo, Young-Hoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.4
    • /
    • pp.365-370
    • /
    • 2007
  • This paper studies an automation problem of a heating, a ventilating, and an air conditioning (HVAC) for the development of smart space. The HVAC system is described by the fuzzy system for the stability analysis and the controller design. The linear matrix inequalities (LMIs) conditions are derived for the stabilization problem of the closed-loop system under the analog control. Also, it is required to digitally redesign the pre-designed the analog HVAC control system in order to accomplish the remote control via web. It is shown the this digital redesign problem can be converted to the convex optimization problem with the LMI constraints. An example is provided to show the effectiveness of the proposed method.

Performance Analysis of a Heat Pump Using Refrigerant Mixtures (II) (혼합냉매를 사용한 열펌프의 성능해석 (II))

  • Kim, M.S.;Kim, T.S.;Won, S.P.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.218-225
    • /
    • 1990
  • Studies on the performance of a heat pump using non-azeotropic refrigerant mixtures are done. In order to estimate the thermodynamic properties for the selected non-azeotropic refrigerant mixtures including R22/R152a, R22/R142b, R22/R114 and R13B1/R152a, Peng-Robinson equation of state is adopted. The pressure-enthalpy diagram and the temperature-entropy diagram are plotted for each refrigerant mixture. Considerations on the capacity modulation for the heat pump system using refrigerant mixtures are taken into. Results show that when the heating load varies, the possibility for the capacity modulation is found in the heat pump system using a compressor with constant volume flow rate. Under a constant heating capacity condition in the heat pump system, the coefficient of performance increases when the refrigerant mixtures are used. The volume flow rate decreases as the mass fraction of lower boiler increases in this case.

  • PDF