• 제목/요약/키워드: Heating-conditioning

검색결과 1,161건 처리시간 0.031초

저탄소 농촌마을 계획지표의 AHP 분석 (The Analysis of Indicators for Low Carbon Rural Village Planning by AHP)

  • 김은자;고아라;이정원;김상범
    • 농촌지도와개발
    • /
    • 제18권3호
    • /
    • pp.551-567
    • /
    • 2011
  • The Purpose of this study is to calculate the importance of the indicators for low carbon rural village planning. We made two kinds of indicators for inland area and waterside area to consider regional disparities. To develop indicators, a draft of the indicators was estimated with collected research materials and 42 experts reviewed this draft three times with modified delphi technique to check the validity and revise the draft. As a result, the inland indicators were settled with 4 domains 8 items 20 indicators and the waterside indicators were 4 domains 8 items 22 indicators. And next, calculating the importance of each indicators is progressed by AHP, analytic hierarchy process. So 42 experts chose the best important indicator related to air conditioning and heating or agricultural spin off in two kinds of indicators. The final indicators will be used to realize low carbon rural village planning in future which the government is pushing forward with construction of six-hundred low carbon green village.

대구시 공공건축물의 에너지 소비 원단위에 관한 연구 (An Analysis on the Energy Consumption Unit of the Public buildings in Daegu)

  • 최정희;김주영;홍원화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2005년도 추계학술대회 논문집
    • /
    • pp.319-322
    • /
    • 2005
  • An energy problem has become one of the many Problems awaiting solution to human society. Energy needs to support not only industry, but also building in city. The types of residential building, office building and public building account for much proportion among the totally amount used energy. A public institution shows a fine example for an energy conservation in the present situation. But, the amount used energy of electricity, air-conditioning and heating is different from a building use and condition. Because the building data of the energy consumption by a load is insufficient, it is unable to select a proper energy source. According to this study, it analyzed an energy load by each building that had investigated the actual conditions of energy consumption about public buildings in Daegu City. In order to plan the efficient energy use both existing buildings and new buildings, this study will present the efficient energy use plan, which has operated to new buildings of a public institution, at present.

  • PDF

국내 원자력발전소의 주제어실 화재 피난 리스크 평가를 위한 화재 시뮬레이션 (Fire Simulations for the Abandonment Risk Assessment of Main Control Room Fire in Domestic Nuclear Power Plant)

  • 강대일;김길유;장승철;유성연
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.199-207
    • /
    • 2014
  • In this paper, to systematically assess the abandonment risk of main control room (MCR) fire, fire simulations with Fire Dynamics Simulator were performed and abandonment probabilities were estimated for the MCR bench-board fire of domestic reference nuclear power plant. The fire simulation scenarios performed in this study included propagating and non-propagating fires of the MCR bench-board, and the availability and unavailability of heating, ventilation, and air conditioning system (HVACS). The following results were obtained. First, temperature was the major abandonment impact factor for the MCR bench-board fire if the HVACS was available and optical density was that if the HVACS was unavailable. Second, the fire scenario contributing the MCR bench-board fire abandonment risk was identified to be only the propagating fire. Third, it was confirmed that the abandonment probability of the MCR bench-board fire for domestic reference nuclear power plant could be reduced by using the fire modeling.

한국형 기동헬기 동계운용능력 향상을 위한 플래퍼밸브 개선연구 (A Study on Winter Season Usability Performance Improvement of Flapper Valve for KUH-1)

  • 최재형;장인기;심대성;안정민
    • 한국항공우주학회지
    • /
    • 제44권1호
    • /
    • pp.49-56
    • /
    • 2016
  • 한국형 기동헬기(KUH-1)에 적용된 플래퍼밸브는 환경제어계통 장비로서 조종사의 임무수행에 핵심적인 장비이다. 플래퍼밸브는 조종사 및 승무원에게 난방, 환기, 공기조절기능을 가지고 있고, 항공기 내부온도를 유지시킴으로서 조종사 및 병력의 작전 운용능력을 만족시킨다. 본 논문에서는 플래퍼밸브의 비행시험 지적사항을 발생원인 별로 분류하고, 각 지적사항에 대한 고장탐구 수행과정을 정리하였다. 또한, 고장탐구 내용을 바탕으로 도출한 설계개선 사항과 개선사항에 대한 저온비행시험 검증 결과를 함께 기술하였다.

첨가원소에 따른 $BaTiO_3$ 계 PTC 세라믹스의 전기적 특성 (Electrical Properties of $BaTiO_3$ PTC Ceramics with Additional Elements)

  • 김혜진;홍윤정;이규만
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.305-306
    • /
    • 2006
  • 자동차의 난방 열원은 HVAC(Heating, Ventilating & Air Conditioning)에 내장되어 있는 히터코어 (Heater Core) 에서 공급하게 되며, 이 히터코어는 엔진에서 가열된 냉각수 열원을 이용하게 된다. 그러나 최근 디젤 엔진의 경우 연소효율의 개선과 CEGR(Cooled Exhaust Gas Recirculation) 시스템의 적용으로 냉각부하가 증가하여 냉각수가 가지는 가용 열원이 기종보다 약 30~40% 정도 저하되고 있다. 따라서 디젤 자동차 및 하이브리드용 자동차의 난방 보조 히터의 국산화 개발이 시급해진 상황이며 초정밀, 고효율 보조 히터의 개발이 요구되고 있다. 현재 적용되고 있는 보조 히터 중에서 PTC 히터는 PTC 소자의 발열을 이용하여 공기를 직접 가열하기 때문에 추가적인 연료소비가 없고 소형 및 저가라는 장점이 있다. PTC 세라믹 소자는 $BaTiO_3$를 모체로 하며, 이의 특성 항상 및 제어를 위해서는 적절한 dopant를 선택하여 균일하게 doping 해야 한다. 지금까지 dopant에 따른 구성 요소 및 역할은 비교적 잘 알려져 있다. 하지만, 자동차용으로 사용되기 위해서는 12V의 저전압에서 동작해야 하며, 또한 소자의 두께가 얇아지게 됨에 따라서 발생하는 전기적 short와 같은 문제점들을 해결하여야 한다. 따라서 본 연구에서는 PTC 세라믹 소자에서 도펀트 종류와 양 조절을 통한 저저항을 확보하고, PTC 세라믹 소자의 박막화를 달성하고자 하였다.

  • PDF

능동적 신재생에너지 생산을 통한 하수처리장 에너지자립화 향상 (Improving Energy Self-sufficiency in Municipal Wastewater Treatment Plant using Renewable Energy Production)

  • 강지훈;채규정;김동수;양희정;안영섭;김원경;김정현;박동을
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2012년도 학술발표회
    • /
    • pp.643-643
    • /
    • 2012
  • Increasing energy prices and growing concerns about global warming address the need to improve energy self-sufficiency in many industrial and municipal sectors. Wastewater treatment plants (WWTPs) are representative of energy-consuming facilities in Korea, accounting for 5% of national energy consumption. We present renewable energy technologies and energy self-sufficiency scenarios in a municipal WWTP ($30,000m^3d^{-1}$) located in Yongin, South Korea. By employing photovoltaics (PV, 135 kW), small hydropower turbine (10 kW), and thermal energy from treated effluent (25 RT: refrigeration ton) within the WWTP, a total of 142 tonne of oil equivalent (toe) of energy was estimated to be generated, accounting for $365ton\;CO_2\;yr^{-1}$ of greenhouse gas emission reduction. Core renewable technologies under consideration include 1) hybrid solar PV system consisting of fixed PV, dual-axis PV, and building integrated PV, 2) low-head small hydropower plant specifically designed for treated effluent, 3) effluent heat recovery system for heating and air conditioning. In addition to these core technologies, smart operation and management scheme will be presented for enhancing overall energy savings and distribution within the WWTP.

  • PDF

The Study on Miniaturization and Weight Reduction of Auxiliary Power Unit in Magnetic Levitation Train

  • Lee, Na Ri;Shin, Hee Keun;Choi, Sung Ho;Kim, Ju Bum;Lim, Jae Won;Park, Doh Young;Mok, Hyung Soo
    • International Journal of Railway
    • /
    • 제8권1호
    • /
    • pp.10-14
    • /
    • 2015
  • Due to the characteristics of the vehicle structure, the magnetic levitation train has a confined bottom space thus a study on miniaturization and weight reduction of auxiliary power unit is essential. This auxiliary power unit is an essential device used for illumination, air conditioning, heating and air brake equipment excluding the motor. The previous auxiliary power unit for magnetic levitation train has used the hard switching having a high switching frequency with heavy loss in order to reduce the size of filter reactor and transformer but the reduction in volume was not significant. In this paper, by reducing the loss, reducing the size of the cooling unit and by increasing the switching frequency using the soft switching of resonant converter, it has miniaturized and reduced the weight of filter reactor and transformer which occupy significant space in the auxiliary power unit. This study has verified the performance of 50KVA grade prototype through simulated interpretation and analysis, and compared the size and weight of auxiliary power unit of the previous magnetic levitation train.

수평형 지열교환기 성능의 경년변화 (An Experimental Study on the Thermal Performance Change of Horizontal-type Geothermal Heat Exchanger with Long-Term Operation)

  • 황광일;우상우;김중헌;양기영;신승호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.725-730
    • /
    • 2006
  • The purpose of this study is on the performance evaluation of horizontally installed GHEX(Geothermal Heat Exchanger, HGHEX) which has been operated for 5 years successfully. Followings are the results. Firstly, in summer season, on Aug. 2000, $33^{\circ}C$ water was flowing out from HGHEX with continuous operating method, and $27{\sim}29^{\circ}C$ with interval operating method on Jul. 2005. But $2.5{\sim}3.0^{\circ}C$ temperature differences are gained from HGHEX. Secondly, in winter season, on Nov. 2000, $25^{\circ}C$ water was flowing out from HGHEX with continuous operating method, and $13{\sim}15^{\circ}C$ with interval operating method on Jan. 2006. But with each operating method, only $0.1^{\circ}C$ and $0.7^{\circ}C$ temperature differences are gained from HGHEX respectively. As the conclusion of this study, at the point of continuos operating method, seasonal balance of heating and cooling loads, and at the point of interval operating method, balance for geothermal restoring time respectively must be considered for better system performances.

  • PDF

설문조사를 통한 노후 공동주택의 설비 리모델링 의식조사 (A Residents' Mechanical Equipment Remodeling Preferences Study on the Aged Apartment Housing by Questioning Survey)

  • 김지현;유선용;이상엽;정차수;김태연;이승복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1061-1068
    • /
    • 2006
  • This study has been conducted to provide the basic datum to draw mechanical equipments needed for aged apartment housing remodeling by questioning survey and interview for residents who has been lived in the aged apartment housing. To preferences survey, we prepare four forms of sheets - questioning survey and interview for residents, interview for managers, and visiting interview for residents. The questioning survey results shows that some residents feel discomfort for water hammer and water supply noise and for noise and stink transmission from air duct installed ceiling to ventilate bathroom. The interview results for residents and managers shows typically two major problems. The first is insulation and heating problems when balcony extended in each household. The second is piping and shaft layouts problem for maintenance and remodeling flexibility. It is important to study indepth each problems because these problems will increase more in the future.

  • PDF

전기구동 히트펌프(EHP)와 가스엔진구동 히트펌프(GHP)의 에너지소비량 및 환경부하 분석 (Analysis of Energy Consumption & Environmental Load of Electric Heat Pump and Gas Engine Driven Heat Pump)

  • 김상훈;임상채;정광섭;김영일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.933-937
    • /
    • 2006
  • Energy is motive power that makes convenient society. But, our country's energy is depending on most import. Also, energy and environmental issue are important problem in community of nations. The purpose of this study is to analysis the energy consumption and environmental load of EHP and GHP in Medium and small-scaled office building. The annual energy consumption used to cooling and heating by EHP was 10 percent more than GHP. And annual energy cost of EHP was 33 percent more expensive than GHP. But, Compared to the annual $CO_2$ emission, EHP was 6 percent less than GHP. Therefore, equipment selection should be consider environmental load as well as energy consumption and cost.

  • PDF