Recovery system 적용을 통한 바이오가스플랜트의 안정화 기술 (Stabilization technology of biogas plant applied recovery system)

  • 장병인;정미화;조윤미;조용일;박경호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.102.2-102.2
    • /
    • 2010
  • We are to evaluate the stabilization technology of actual biogas plant facilities, which is operating currently. It describes the traits of the consistent facilities of mesophilic anaerobic digestion using Unison Biogas plant Recovery system(UBR). Also the economical efficiency is examined with the electric power sales earnings and applying the deserted heating by generating electric power, which is generated by operated combined heat and power using biogas produced by mesophilic anaerobic digestion. We have generated the 481,113kw for electric power and 1,376Gcal for thermal energy simultaneously. If these electric power and thermal energy are converted into diesel, we can achieve savings equal to 114,300L, and 152,109L in the quantity of heat. Finally, if CDM, RPS, liquid fertilizer sales business, etc. is activated, the earnings will be expected to improve dramatically and is considered to contribute a drop of the greenhouse gas.

  • PDF

간접열식 LPG온풍난방기 개발 (Development of LPG hot air heater for greenhouse heating)

  • 김영중;유영선;장진택;이건중
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 1999년도 정기총회 및 학술논문발표요지
    • /
    • pp.9-14
    • /
    • 1999
  • 1. LPG 온풍기는 용량 16$\times$$10^4$ ㎉ 건타입가스버너, 연소부 및 열교환부, 6개의 50kgLPG탱크와 자동절체기, 가스메타, 배관으로 구성하였다. LPG 온풍기의 이론연소효율은 91%, $CO_2$ 배출량은 11.74%, CO배출량은 0ppm, 과잉공기비는 1.16, 배기가스온도는 253$^{\circ}C$, 온풍온도는 8$0^{\circ}C$로서 우수한 성능으로 나타났다. 2. LPG온풍기에서 배출되는 배기가스중의 $CO_2$ 를 온실로 공급하기 위하여 $CO_2$ 공급기를 제작하여 배출가스연도에 부착하였다. $CO_2$ 공급기는 흡입형 시로코팬(1200㎥/h)과 차단문으로 이루어졌다. 1-2W형 300평 온실내의 $CO_2$ 농도를 1000ppm으로 올리기 위해서는 $CO_2$ 공급기를 약 1시간 정도 운전시켜야 할 것으로 판단되었다. 3. LPG온풍기와 경유온풍기의 경제성 비교분석에 의하면 현 시점의 경유 가격 242원, LP가스 가격 435원을 기준으로 연간소요비용은 각각 5,392,430원, 5,299,917원으로 경유온풍기가 10만원 정도 경제적이지만 탄산가스 시용비용, 탄산가스 공급으로 인한 작물의 수량증대 및 고품질 생산물을 고려한다면 LPG온풍기 사용이 더 경제적이라 사료된다.

  • PDF

딸기재배 온실의 현장조사 분석 -서부경남 지역을 중심으로- (Field Survey of Greenhouse for Strawberry Culture -Case Study Based on Western Gyeongnam Area-)

  • 정영균;이종구;윤성욱;김현태;윤용철
    • 생물환경조절학회지
    • /
    • 제27권3호
    • /
    • pp.253-259
    • /
    • 2018
  • 본 연구에서는 딸기의 생육 및 환경관련 데이터를 활용하여 딸기 재배 온실의 최적 환경 구현을 위한 시스템을 선정하고 생산성 향상에 대한 연구를 위한 기초자료로 활용할 목적으로 서부 경남 지역 중 딸기 재배로 유명한 지역의 온실을 대상으로 현장조사를 실시하였다. 이 결과를 바탕으로 경상대학교 내에 딸기 재배용 테스트 베드 온실을 설치하여 연구를 실시하고자 본 연구를 수행하였다. 그 결과 재배농가의 연령대를 보면, 상대적으로 50대 및 60대가 가장 많았지만, 50대 이하가 27개 농가로서 전체의 약 67.5%정도이었고, 60대 이상은 32.5%정도인 것으로 나타났다. 재배경력의 경우, 10년 이하가 주류를 이루고 있지만 30년 이상인 경우도 있었다. 대상농가 모두가 단동온실로서 대부분이 아치 형태인 것으로 나타났으며, 양액재배 농가가 약 75%정도로 토경재배보다 많은 것으로 나타났다. 양액재배의 경우, 전체 농가가 고설재배를 하고 있었다. 단동온실의 폭, 측고 및 동고는 조사지역에 관계없이 각각 7.5~8.5m, 1.3~1.8m 및 2.5~3.5m정도 이었다. 서까래 간격도 0.7~0.8m정도인 것으로 나타났다. 고설재배의 경우, 고설재배 베드의 폭, 높이 및 간격은 각각 0.25m전후, 1.2m전후 및 1.0m전후인 것으로 조사되었다. 딸기 품종의 경우, 국산이 약 97.5%를 차지하고 있었고, 이 중 설향이 약 65.0%로서 가장 선호하고 있는 것으로 나타났다. 온실 내부 환경요인으로 38개 농가가 온도와 상대습도만 계측하였다. 2개 농가는 최근에 국산 제품인 스마트 팜 시스템을 도입한 농가도 있었다. 양액재배의 경우는 양액제어 시스템을 이용하고 있었다. 이 외에도 관비기를 사용하거나 환기 및 유동 팬을 사용하고 있는 농가도 있었다. 온습도 조절은 스마트 팜 시스템을 도입한 농가를 제외하고 약 85%인 34개 농가에서 측창이나 환기팬을 작동시키는 제어패널만을 이용하여 조절하였고, 수동으로 측창을 개폐하고 있는 농가도 10%정도인 4개 농가가 있었다. 보온 및 난방의 경우, 전체 대상 농가가 수막을 이용하고 있었다. 이 외에 필요에 따라 기름 및 전기보일러, 방열 램프 및 부직포 등을 병행하여 이용하는 농가도 다수 있었다.

Analysis of Chemical Compositions and Energy Contents of Different Parts of Yellow Poplar for Development of Bioenergy Technology

  • Myeong, Soo-Jeong;Han, Sim-Hee;Shin, Soo-Jeong
    • 한국산림과학회지
    • /
    • 제99권5호
    • /
    • pp.706-710
    • /
    • 2010
  • Understanding of chemical composition and energy contents in tree is important to develope strategies of renewable energy policy to cope with climate change. Residual biomass as renewable energy source was evaluated and focused on the bark-containing branches. Chemical analysis studies were conducted for different part of yellow poplar (Liriodendron tulipifera), which were partitioned to inner bark, outer bark, small branches, medium branches, big branches and trunk. The variations in hydrophobic extractives, hydrophilic extractives, lignin, carbohydrate compositions, energy contents (higher heating value) and the ash content were determined. The inner and outer bark had higher ash content, hydrophobic and hydrophilic extractives content, and higher energy content than those of tree trunk. Polysaccharides content in inner and outer bark was quite lower than those of stem or branches. Based on the energy content of residual biomass, replacement of fossil fuel and greenhouse gas emission abatement were calculated.

차량용 공조시스템의 현황 및 고속버스의 실내 공기 환경 측정 (The Assessing the HVAC system and Measurements of Indoor Air Quality of Highway Bus)

  • 유호천;노경환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.263-268
    • /
    • 2009
  • The current focus of domestic car industry is moving from technological development to reducing greenhouse gas. This study investigates and measures the HVAC system and indoor air condition of highway buses, which is conducted to develop a HVAC system using natural energy in the future. The measurements show that thermal balance is not fulfilled because heating sources are randomly placed, and relative humidity is in the 20 percent range both in HVAC and non-HVAC systems, which is far below 40%, or the highest thermal comfort level. CO2 concentration was found to be an average of 1500 ppm, but not more than 2522 ppm with 15 persons on board, and with 29 persons on board, an average of 2053 ppm, but not more than 3066 ppm, both of which far exceed allowed CO2 concentration level, or 1000 ppm. Generally, highway buses drop by rest stops and open doors for 15 to 20 minutes for getting in fresh air. But its air improvement effect is temporary, and it exacerbates indoor air condition.

  • PDF

온실 난방을 위한 평판형 태양집열기의 열적성능 분석 (Analysis on the Thermal Performance of Flat-plate Solar Collector for Greenhouse Heating(I))

  • 서원명;윤용철;이승환;이석건
    • 한국농공학회지
    • /
    • 제40권6호
    • /
    • pp.46-56
    • /
    • 1998
  • This study was performed to investigate thermal performances of two different types of flat-plate solar collector systems; natural circulation system and forced circulation system. Conclusions obtained from this study are summarized as follows; 1) In the natural circulation system, the total heat amounts retrieved by starting recovery soon after sunrise were ranged from 10.28 to 17.20MJ/m$^2$, while the total heat amounts retrieved by starting recovery after sunset were ranged from 5.31 to 10.77MJ/m$^2$. 2) The collector efficiency in natural circulation system were ranged from 51.1% to 54.1% when the collected heat was retrieved after sunrise and were 65.8~78.0% when the collected heat was retrieved soon after sunset. 3) According to the regression analysis between fluid flow rates and fluid temperature difference at inlet and outlet of collector pipe, there was high regressive corelations with regression coefficient, r, of 0.982. 4) The collector efficiencies estimated for forced circulation system were 73.1~88.6%, and 78.4~94.8%, and 64.2%~74.5%, respectively when fluid circulation rates were 4.2 l/min, and 7.0 l/min, respectively.

  • PDF

전기적 열선의 발화 및 화재 위험성에 관한 연구 (A Study on Ignition and Fire Risks of Electric Heat Wire)

  • 민세홍;송병준
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.113-121
    • /
    • 2015
  • This study aims to examine the risk of electrical fire in places where electric heat wires are used. In general, the use of electric heating wires is becoming more common and prevalent in a bid to prevent increasing damage caused by freezing and bursting in residential water pipes, factory pipes and irrigation pipes in vinyl greenhouse and a variety of heat wire products are available in market with legal safety requirements imposed on them. However, the widespread use of anti-freezing burst heat wire products has caused increasing incidents of fire, which often fail to be incorporated into statistics due to quick onsite extinguishing and insignificant damage although damage is gradually on the rise. Against this backdrop, this study aims to look into the possibility of ignition caused by electric heat wires and the mechanism of how it turns into catching fire through overheat and short circuit tests for anti-freezing burst electrical heat wires (hereinafter called the 'heat wire') and expects to serve as the basis for further observations and analyses on the cause of fire and the process of ignition in a scientific manner.

Stabilization Characteristics of Upgraded Coal using Palm Acid Oil

  • Rifella, Archi;Chun, Dong Hyuk;Kim, Sang Do;Lee, Sihyun;Rhee, Youngwoo
    • 청정기술
    • /
    • 제22권4호
    • /
    • pp.299-307
    • /
    • 2016
  • These days, coal is one of the most important energy resources used for transportation, industry, and electricity. There are two types of coal: high-rank and low-rank. Low-rank coal has a low calorific value and contains large amounts of useless moisture. The quality of low-rank coal can be increased by simple drying technology and it needs to be stabilized by hydrocarbons (e.g. palm acid oil, PAO) to prevent spontaneous combustion and moisture re-adsorption. Spontaneous combustion becomes a major problem during coal mining, storage, and transportation. It can involve the loss of life, property, and economic value; reduce the quality of the coal; and increase greenhouse gas emissions. Besides spontaneous combustion, moisture re-adsorption also leads to a decrease in quality of the coal due to its lower heating value. In this work, PAO was used for additive to stabilize the upgraded coal. The objectives of the experiments were to determine the stabilization characteristic of coal by analyzing the behavior of upgraded coal by drying and PAO addition regarding crossing-point temperature of coal, the moisture behavior of briquette coal, and thermal decomposition behavior of coal.

가정용 연탄보일러의 Non-CO2 배출계수 개발 (Development of Non-CO2 Emission Factor of the Coal Briquette Boiler)

  • 송가람;조창상;이대겸;전의찬
    • 한국기후변화학회지
    • /
    • 제8권2호
    • /
    • pp.163-169
    • /
    • 2017
  • In this study, Non-$CO_2$ emission factors were estimated for the coal briquette boiler, which is the Korean heating system. As a result, the $CH_4$ and $N_2O$ emission factors of the coal briquette boiler were estimated to be $11.76gCH_4/TJ$ and $7.44kgN_2O/TJ$, respectively. The results showed that $CH_4$ emission factor was 12 times and $N_2O$ emission factor was 5 times higher than IPCC default value. Also the emission factors developed in this study were compared with a precedent study. The results indicated that were similar to open the air inlet of coal briquette stove because the combustion condition of this study was similar to that of coal briquette stove.

야간온도 변화에 따른 망고 'Irwin'의 개화, 과실특성 및 수체생육 (Flowering, Fruit Characteristic and Shoot Growth of the Mango, cv. 'Irwin' in Response to D ifferent Night Temperature)

  • 임찬규;안현주;전미경;김설아;정선우
    • 한국농림기상학회지
    • /
    • 제23권4호
    • /
    • pp.349-355
    • /
    • 2021
  • 본 연구는 꽃눈발아기부터 과실비대기까지 야간온도의 조정이 망고 'Irwin' 품종의 개화, 과실특성 및 수체생육에 미치는 영향을 조사함으로써 망고 재배를 위한 적정 야간온도를 구명하고 시설하우스 내부의 온도관리 방안을 모색하고자 수행하였다. 야간온도 처리에 따른 개화기, 만개기, 착과기, 성숙기 그리고 수확기는 온도가 높을수록 빨라지는 경향을 보였다. 꽃대길이는 야간온도가 10℃일때 가장 짧았으며 온도가 높을수록 생육이 좋아졌으나 15℃와 20℃의 처리간에는 유의차는 없었다. 과실 종경과 무게는 야간온도가 15℃와 20℃가 10℃보다 높게 나타났으며 가용성고형물함량(SSC)와 산함량(TA)은 야간온도 처리간에 차이를 보이지 않았다. 그리고 과실의 경도와 과피의 색도는 야간온도가 높을수록 높게 나타났다. 과실 수확이 끝나고 전정을 한 이후 발생한 가지의 생육은 처리간 유의차를 보이지 않았다. 따라서 망고의 시설하우스 재배 시 과실의 수량을 높이고 고품질 과실을 생산하기 위해서는 야간 최저온도를 15℃ 또는 20℃로 설정하는 것이 적절하며 난방비 절감을 위해서는 야간 최저온도를 15℃로 설정하여 재배하는 것이 바람직한 것으로 판단된다.