• 제목/요약/키워드: Heating Unit

검색결과 495건 처리시간 0.033초

지연성 뇌병증을 보인 일산화탄소 중독 1례 (A Case of Delayed Carbon Monoxide Encephalopathy)

  • 윤성현;정현민;강환석;김지혜;한승백;김준식;백진휘
    • 대한임상독성학회지
    • /
    • 제11권1호
    • /
    • pp.41-45
    • /
    • 2013
  • Following are brief statements about the delayed encephalopathy of a patient who recovered without disturbance of consciousness after acute carbon monoxide poisoning. A 72-year-old male was found without consciousness at home and then visited the ER center. Later we learned that the patient was using briquettes as a household heating source. Blood carbon monoxide hemoglobin level was 17.5%. As carbon monoxide poisoning was uncertain after the first interview with the patient, hyperbaric oxygen therapy was not administered at the early stage. After supplying 100% oxygen, the patient recovered consciousness, however, the strength of the lower limb muscle had decreased to class II. The patient showed continued weakening of the lower limb muscle and an increase of CPK; therefore, he was diagnosed as carbon monoxide intoxication and rhabdomyolysis and then admitted to the intensive care unit (ICU) for conservative treatment. During the hospitalization period, continued weakening of the lower limb muscle was observed and he was diagnosed as myopathy after EMG/MCV. However, he suddenly showed altered mentality on the 20th day of hospitalization, and underwent brain MRI. T2 weighted MRI showed typically high signal intensity of both globus pallidus and periventricular white matter; therefore, he was diagnosed as delayed carbon monoxide encephalopathy. This case showed delayed encephalopathy accompanied by rhabdomyolysis and myopathy of a patient who recovered without disturbance of consciousness.

  • PDF

고정층 반응기에서 망간광석(NMD)을 이용한 저농도 일산화탄소 산화특성 (Oxidation Characteristics of Low Concentration CO Gas by the Natural Manganese Dioxide(NMD) in a Fixed Bed)

  • 이영순;박종수;오광중
    • 청정기술
    • /
    • 제2권1호
    • /
    • pp.60-68
    • /
    • 1996
  • 고정층 반응기에서 망간광석을 이용하여 저농도의 일산화탄소 산화제어반응에 대하여 고찰하였다. 고려된 실험변수는 일산화탄소 농도 (500ppm~10000ppm), 산소 농도(500ppm~99.8%)와 촉매의 온도($50{\sim}750^{\circ}C$)이다. 또한 망간광석의 특성은 Thermogravimetric Analysis(TGA), 일산화탄소에 의한 환원, Temperature Programmed Reduction(TPR)실험을 이용하여 규명하였다. 망간광석의 일산화탄소 산화력은 순수이산화망간에 비해서 단위 면적당 높은 산화력과 $750^{\circ}C$까지 가열된 후에도 산화력이 유지될 수 있는 안정된 촉매작용을 보였다. Temperature Programmed Desorption(TPD), TPR 실험과 TG 등의 분석결과 산소의 농도가 낮거나 무산소하에서 망간광석의 격자내 산소가 쉽게 제공될 수 있음을 알 수 있었다. 일산화탄소의 농도가 500~3500ppm일 때 일산화탄소의 반응차수는 0.701이며 3500~10000ppm구간에서 일산화탄소의 농도에 무관한 0차 반응이었다.

  • PDF

검은비늘버섯 물 추출물 및 유기용매 분획물의 생리활성 효과 (Physiological Activities of Water Extract and Solvent Fractions of an Edible Mushroom, Pholiota adiposa)

  • 김준호
    • 한국균학회지
    • /
    • 제42권3호
    • /
    • pp.207-212
    • /
    • 2014
  • 검은비늘버섯을 이용하여 심혈관계 질환과 관련된 기능성 식품 개발을 위한 기초자료를 얻기 위해 검은비늘버섯물 추출물과 유기용매 분획물을 이용하여 심혈관계 질환관련 생리활성을 확인하였다. 물 추출물은 57.57%의 항산화활성을 나타냈지만 혈전용해활성, 트롬빈저해활성, ${\alpha}$-glucosidase 저해효과는 매우 낮게 나타났다. 반면 에틸 아세테이트 분획물은 0.70 plasmin unit의 높은 혈전용해 활성과, 87.36%와 46.44%의 높은 트롬빈 저해활성과 ${\alpha}$-glucosidase 저해활성을 나타냈으며, 물 분획물은 48.27%의 항산화활성을 나타냈다. 혈전용해활성이 높은 에틸 아세테이트 분획물은 섬유소원의 $A{\alpha}$$B{\beta}$ chain은 모두 분해시켰지만 ${\gamma}$ chain과는 반응하지 않았으며, $100^{\circ}C$에서 10분간 가열에도 혈전용해 활성에 변화가 없었다. 실험 결과로부터 검은비늘버섯의 에틸아세테이트 분획물은 높은 혈전용해활성과 트롬빈 저해활성과 ${\alpha}$-glucosidase 저해활성을 나타내 심혈관계 질환 관련 치료나 예방을 위한 기능성식품 개발에 이용 가능할 것으로 기대된다.

화학열펌프에 있어서의 무기수화물계 축열시스템에 관한 연구(I) - 탈수 축열 성능연구 - (A Study on the Heat Storage System for Chemical Heat Pump Using Inorganic Hydrates(I) - Heat Storage Characteristics -)

  • 박영해;김종식
    • 태양에너지
    • /
    • 제15권3호
    • /
    • pp.29-38
    • /
    • 1995
  • 본 연구는 화학열펌프 개발을 목적으로 비교적 고온영역에서 화학축열에 응용 가능 할 것으로 판단되는 무기수화물계 $Ca(OH)_2/CaO$ 가역 반응싸이클을 이용한 수화 탈수반응에 따른 충진층내 열이동에 대하여 실험적 검토를 행하였다. 그 결과 본 실험에서 얻은 열교환특성은 $Ca(OH)_2$ 열분해 탈수반응시 반응기 내의 시료층 상단부가 하단부에 비해 탈수반응이 느리게 진행되었으며 이러한 현상은 탈수반응이 하부에서 상부로 진행됨을 알 수 있었다. 또, 반응기내 반경방향에서의 $Ca(OH)_2$ 열분해 탈수반응에 따른 온도변화는 시료 중심부에서 상 하단부로 나타났으며 이는 열전도도에 의한 온도 강하로 중심부의 축열온도가 높음을 알 수 있었다.

  • PDF

씨앗층이 바륨훼라이트 박막의 형성과 자기적 성질에 미치는 영향 (Effects of Seed Layers on Formation of Barium Ferrite Thin Films and Their Magnetic Properties)

  • 나종갑;이택동;박순자
    • 한국자기학회지
    • /
    • 제2권1호
    • /
    • pp.22-28
    • /
    • 1992
  • 대향타겟형 스파터기에서 철과 BaO 복합타켓트를 사용한 반응성 스파터링 방법으로 고밀도 수직자기기록용 바륨훼라이트박막을 제조하였다. 표면 열 산화된 규소 웨이퍼를 기판으로 사용한 경우 바륨훼라이트박막의 c축이 기판에 완전히 수직으로 배열하기 위해서는 $750^{\circ}C$의 기판가열이 필요 하였다. 기판가열온도를 낮추기 위하여 ZnO, ${\alpha}-Fe_{2}O_{3}$${\gamma}-Fe_{2}O_{3}$ 씨앗층을 사용한 결과 바륨훼라이트와 같은 육방결정구조이면서 (002)면이 기판에 평행하게 배향된 ZnO 씨앗층을 사용하였을 때 $600^{\circ}C$에서 c축배향이 우수한 바륨훼라이트박막을 성막시킬 수 있었다. 바륨훼라이트의 포화자화값은 295 emu/cc 수직보자력은 1.7kOe 각형비는 0.75 이었다. 복합타켓트를 사용하여 $230\;{\AA}/min$의 피착속도로 바륨훼라이트박막을 피착시킬 수 있었는데 이것은 지금까지 발표된 산화물 타켓트를 사용한 경우보다 5-20배 빠른 것이다.

  • PDF

PC 적용을 위한 고강도 매스콘크리트의 수화특성에 관한 연구 (Study on Hydration Properties of High Strength Mass Concrete to apply Precast Concrete)

  • 박흥이;김성진;이회근;이승훈;박병근;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.661-664
    • /
    • 2008
  • 고층 대형 건축물에 사용되는 기둥 보 등의 단면치수가 큰 Precast Concrete 부재는 제조과정에 있어서 외부에서의 가열뿐만 아니라, 시멘트수화열의 축척에 의한 내부에서의 온도 상승도 작용되기 때문에, 단면치수가 비교적 작은 벽, 밑바닥 등의 Precast Concrete 부재와는 다른 온도이력을 나타낸다고 생각할 수 있다. 이에 본 연구는 Precast Concrete적용을 위한 고강도 매스콘크리트 부재의 강도특성을 검토하기에 앞서, 온도이력특성을 밝히는 것을 목적으로 했다. 단면치수가 큰 Precast Concrete 모의부재의 단면치수, 단위시멘트량, 양생조건이 가각 다른 Precast Concrete 부재를 제조할 때의 온도이력특성을 총괄적으로 검토하여 분석하였다.

  • PDF

물-공기 지열 멀티형 열펌프 시스템 실증연구 (Verification Experiment of a Water-to-air Ground Source Multi-heat Pump System)

  • 김철우;김병국;이평강;임효재;강신형;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제6권1호
    • /
    • pp.9-16
    • /
    • 2010
  • The aim of this study is to verify the performance of water-to-air multi-heat pump system with a vertical U-tube GLHX(U-tube system) and a double tube GLHX(double tube system), which were installed in a school building located in Asan. For analyzing the performance of the GSHP system, we monitored various operating da~ including the water temperature of inlet and outlet of the ground heat exchanger, mass flow rate, and power consumption. Daily average COP of the single U-tube system and the double tube system were 4.5 and 4.2 at cooling mode and were 3.5 and 3.8 at heating mode. As a result, We know that performance of water-to-air multi-heat pump unit is reliable at actual condition operated in a part load conditions for all day.

단일채널 내 임계영역 이산화탄소 가열과정의 열유동 특성에 관한 실험적 연구 (Experimental Studies on Thermal-Fluidic Characteristics of Carbon Dioxide During Heating Process in the Near-Critical Region for Single Channel)

  • 최현우;신정헌;최준석;윤석호
    • 설비공학논문집
    • /
    • 제29권8호
    • /
    • pp.408-418
    • /
    • 2017
  • Supercritical carbon dioxide ($sCO_2$) power system is emerging technology because of its high cycle efficiency and compactness. Meanwhile, PCHE (Printed Circuit Heat Exchanger) is gaining attention in $sCO_2$ power system technology because PCHE with high pressure-resistance and larger heat transfer surface per unit volume is fundamentally needed. Thermo-fluidic characteristics of $sCO_2$ in the micro channel of PCHE should be investigated. In this study, heat transfer characteristics of $sCO_2$ of various inlet conditions and cross-sectional shapes of single micro channel were investigated experimentally. Experiment was conducted at supercritical state of higher than critical temperature and pressure. Test sections were made of copper and hydraulic diameter was 1 mm. Convective heat transfer coefficients were measured according to each interval of the channel and pressure drop was also measured. Convective heat transfer coefficients from experimental data were compared with existing correlation. In this study, using measured data, a new empirical correlation to predict near critical region heat transfer coefficient is developed and suggested. Test results of single channel will be used for design of PCHE.

PTC와 평판형 태양열집열기의 성능평가 비교 연구 (The Comparative Study on Performance of PTC and Flat-plate Solar Collector)

  • 김인환;허남수;김만석;이정언
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.28-33
    • /
    • 2010
  • Solar collectors to be applied are mainly flat-plate or vacuum tube collector which is used for hot water supply of house because of low heat value and low temperature. There are a necessity to expand applicable scope of solar collector into the industrial process heat source and air conditioner for coping with renewable energy policy of government and industrial trend. This study is to analysis the performance of PTC solar collector of concentrating type and flat-plate of non-concentrating. For this, temperature difference and heating value as insolation of air outside is measured from these two collectors mounted on 2-axial solar tracking system. It is investigated that temperature profile obtained from PTC solar collector is uniform and collecting heat per unit area is 6.8kcal/$m^2$ min which is about 3 times with compare to flat-plate collector of 2kcal/$m^2$min. Also the amount of heat to be produced from PTC solar collector is 3 Mcal/$m^2$ which is about 2 times with compare to flat-plate collector of 1.5Mcal/$m^2$ as a result of operating these two collectors during one month. Therefore, it is obtained that heat collecting performance of PTC solar collector is superior to flat-plate.

STARBURST AND AGN CONNECTIONS AND MODELS

  • SCOVILLE NICK
    • 천문학회지
    • /
    • 제36권3호
    • /
    • pp.167-175
    • /
    • 2003
  • There is accumulating evidence for a strong link between nuclear starbursts and AGN. Molecular gas in the central regions of galaxies plays a critical role in fueling nuclear starburst activity and feeding central AGN. The dense molecular ISM is accreted to the nuclear regions by stellar bars and galactic interactions. Here we describe recent observational results for the OB star forming regions in M51 and the nuclear star burst in Arp 220 - both of which have approximately the same rate of star formation per unit mass of ISM. We suggest that the maximum efficiency for forming young stars is an Eddington-like limit imposed by the radiation pressure of newly formed stars acting on the interstellar dust. This limit corresponds to approximately 500 $L_{\bigodot} / M_{\bigodot}$ for optically thick regions in which the radiation has been degraded to the NIR. Interestingly, we note that some of the same considerations can be important in AGN where the source of fuel is provided by stellar evolution mass-loss or ISM accretion. Most of the stellar mass-loss occurs from evolving red giant stars and whether their mass-loss can be accreted to a central AGN or not depends on the radiative opacity of the mass-loss material. The latter depends on whether the dust survives or is sublimated (due to radiative heating). This, in turn, is determined by the AGN luminosity and the distance of the mass-loss stars from the AGN. Several AGN phenomena such as the broad emission and absorption lines may arise in this stellar mass-loss material. The same radiation pressure limit to the accretion may arise if the AGN fuel is from the ISM since the ISM dust-to-gas ratio is the same as that of stellar mass-loss.