• Title/Summary/Keyword: Heating Unit

Search Result 497, Processing Time 0.026 seconds

A Comparative Study on Heat Transfer Characteristics in Tissue Model with Application of Heating or Cooling Therapeutic Modalities (조직모델에서 냉.온치료기의 열전달 특성 비교 연구)

  • Kim, Yu Jong;Shin, Kyung Min;Kim, Eun Jung;Kim, Kyung Ho;Kim, Kap Sung;Lee, Seung Deok
    • Journal of Acupuncture Research
    • /
    • v.30 no.4
    • /
    • pp.125-138
    • /
    • 2013
  • Objectives : This study aimed to investigate temperature characteristics by heat transfer type of therapeutic modalities. Methods : We selected heating and cooling modalities that are frequently used in clinical by heat transfer type: conduction, convection, radiation, and conversion. We used ham as tissue model, and applied the modalities for 30 minutes. We measured real-time changed temperature($^{\circ}C$) of the surface, 2, 4, 6, 8, 10, 12, and 14 mm depth. Results : 1. In conduction-using hot pack, ice pack, and CryoStamp heating-cooling combination therapy unit($40^{\circ}C/{\sim}15^{\circ}C$), the surface temperature sharply rose close to equilibrium in first 5 minutes. 2. In convection-using smokeless moxa, temperature slowly rose to the maximum at 25-minute elapsed time. But in another convection-using CRAiS cryotherapy device, result was similar to that of conduction. 3. In radiation-using infrared lamp, result was similar to that of conduction, but not reached equilibrium during applying time. 4. In conversion-using ultrasound device, temperature was the highest at 6 mm depth, and not reached equilibrium during applying time. Conclusions : We could comprehend temperature characteristics and proper use of modalities by heat transfer type. It would be necessary to consider in vivo physical conditions in further studies.

Feasibility Identification on Establishment of Solar Energy (Photovoltaic and Solar Heating) at the Environmental Basic Facilities in Busan (부산시 환경기초시설 내 태양에너지(태양광/태양열) 이용 시설 설치 타당성 확인)

  • Kim, Jiwon;Choi, Hyunho;Kim, Samuel;Park, Jeahong;Kim, Donghyun;Lee, Daeseon;Park, Sangtae;Kim, Gyusik;Yu, Jaecheul
    • Journal of Climate Change Research
    • /
    • v.6 no.2
    • /
    • pp.73-85
    • /
    • 2015
  • With 12 environmental basic facilities (EBF) in Busan, each business place's present situation of the operation of new and renewable energy as well as the feasibility to establish additional systems of utilizing solar energy (photovoltaic power generation system [PPGS] and solar heating system [SHS]) were investigated. Currently, with the environmental basic facilities, the new and renewable energies (such as, waste heat, biogas, PPGS, SHS, and small hydro power) can produce 195 GWh per year as electric power unit. Among the energy sources, except waste heat, biogas (154 GWh/yr) appears as the highest. Next, PPGS is the second most widely used system and produces 5,560 MWh/yr at 11 business places. Through a field survey, it appears that 19 business places of total 27 places at 12 EBFs have good locational conditions and they need an introduction of PPGS. Through it, it is investigated that it would be possible to produce 5,311 MWh/yr and to reduce $2,348tCO_2/yr$. And, it is identified that SHS can be additionally introduced in only 4 EBFs. This can reduce energy cost as much as one ten million won/yr and green-house gas as much as $28tCO_2/yr$. A cost-benefic analysis shows that the use of governmental support or private investment can be the most efficient way, when PPGS and SHS are introduced in EBFs.

Investigations on the emergency operation status of existing medical facilities to prepare for emerging infectious diseases in the post-COVID-19 era (포스트 코로나 시대 신종 감염병 대비를 위한 기존 의료시설의 비상시 운영사례 조사 및 분석)

  • Lee, Sejin;Lee, Wonseok;Kim, Eunseok;Yeo, Myoungsouk
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.1
    • /
    • pp.43-51
    • /
    • 2023
  • Purpose: To accommodate the increasing number of patients during the COVID-19 pandemic, numerous portable HEPA filter units (PHUs) were installed in the general wards of existing medical facilities(EMFs) to convert them into emergency conversion facilities (ECFs). The purpose of this study was to build a dataset in preparation for emerging infectious diseases in the post-COVID-19 era by analyzing the construction and operation of ECFs. Methods: Field investigations were conducted during ECF operation periods based on the analysis of heating, ventilation, and air conditioning (HAVC) system design documents for six ECFs across Korea. Interviews were conducted with facility managers during the field investigations. Results: When constructing an ECF within an EMF, the installation status and characteristics of the existing system should be considered. Field investigations and verifications of the operation of HAVC systems must be conducted beforehand for smooth ECF operations. If heating and cooling are required with indoor air circulation type equipment in an ECF zone, the implementation of a heating and cooling method that can satisfy the comfort requirements of the occupants while minimizing cross-contamination is essential. When using PHUs that do not meet the performance standards required by medical equipment, the noise level resulting from such equipment operation must be evaluated and improved. Implications: For EMFs, various guidelines that can be referred to for the construction and operation of ECFs must be developed to prepare for emerging infectious diseases in the future.

A Study on Heat Transfer of n Storage Type Direct Contact Heat Exchanger for Solar Energy Utilization (태양열 이용 축열식 직접접촉 열교환기의 열전달에 관한 연구)

  • Kang, Yong-Heack;Jeon, Myung-Seok;Yoon, Hwan-Ki;Chun, Won-Gee
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.3-14
    • /
    • 1995
  • The Direct Contact heat Exchanger(DCHX) has been widely studied in the chemical industry for many years due to its inherent simplicity as a counter-current divice for heat and mass transfer. In many solar systems, the DCHX unit can be combined with the thermal storage unit, or alternatively, it can be used separately from the storage unit, much like an external(to storage) closed heat exchanger system. In the present work, the spray column type of direct contact heat exchangers are studied extensively to harness the solar energy for hot water and spaced heating. Some of the major considerations that are involved in the design of heat exchangers in this study are that : working fluid is a hydrocaabon(such as Texaterm) or water which is either lighter or heavier than storage medium. The experimental data have revealed some interesting characteristics concerning the application of DCHXs for solar energy utilization. These experiments are carried out in the line of solar heating system, major results are as follows : 1) the flow and aspect of working fluid drop for maxium heat transfer 2) efficiency and volumetric heat transfer coefficient of D.C.H.X with a heavier working fluid are higher than those of D.C.H.X with a lighter working fluid.

  • PDF

Heterotrophic Bacterial Growth on Hoses in a Neonatal Water Distribution System

  • Buffet-Bataillon, Sylvie;Bonnaure-Mallet, Martine;De La Pintiere, Armelle;Defawe, Guy;Gautier-Lerestif, Anne Lise;Fauveau, Severine;Minet, Jacques
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.4
    • /
    • pp.779-781
    • /
    • 2010
  • After preliminary tests indicated an increased number of heterotrophic bacteria, we investigated possible sources of contamination in a neonatal intensive care unit (NICU) water distribution system. Scanning electron microscopic examination of flexible metallic hoses associated with the system revealed the presence of a biofilm; partial 16S rDNA sequencing revealed that the biofilm contained Blastomonas natatoria. Purgation of the water system three times a day, reinforced faucet cleaning, decreasing the cold water temperature to $12^{\circ}C$, and six repeated chlorinations at concentrations as high as 2 mg/l were not sufficient to eradicate the bacterial contamination. Replacing all of the rubber-interior flexible metallic hoses with teflon-lined hoses, followed by heating the water to $70^{\circ}C$, successfully controlled the bacteria.

Economic Analysis of Pleurotus Eryngii Cultivation Facilities (큰느타리버섯 재배사의 경제성 분석)

  • Suh, Won-Myung;Yoon, Yong-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.6
    • /
    • pp.31-41
    • /
    • 2006
  • The analysis used in this work was cost-benefit analysis method. All future costs and returns of a given mushroom house were discounted to the time of initial investment (present) by means of 3.5% discount rate. Then the cost of ownership was compared to the return from the system. This analysis method has been developed and coded into a balance sheet for use on a EXCEL program. Using this programmed analysis,a large number of the case studies were examined using different combinations of economic conditions. These results will be very useful to individuals considering investment in a mushroom house, or any similar production system. By the way of the sensitivity analysis for each important parameter, the change of the marginal cost-benefit period could be finally determined. These parameters were typically construction cost of mushroom house, cost of cooling system, required cooling and heating energy amounts, unit price of mushroom media bottle, growing number of media bottles, production weight per unit bottle, sale price of mushroom, and annual number of growing period, etc.

A Case Study on the Remodeling Plan of Closed School as Elderly Facility And Developing Composition Type -Implication of Okchun Dongyi Middle School- (폐교를 활용한 노인요양시설 리모델링 사례와 평면유형 개발 -옥천군 동이면 동이중학교를 대상으로-)

  • Nam, Yun-Cheol
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.13 no.4
    • /
    • pp.99-106
    • /
    • 2011
  • Since 1982, schools have been closed down by urbanization in rural areas. 3,386 schools had been closed down by March 2010. The average 300 schools was closed down every year. 55.7% closed schools were sold, 14.5% closed schools were rented. 6.3% closed schools have been utilized as education facilities. First, the closed school should be utilized as education facilities. And it should be utilized as public facilities as well as welfare facilities for local residents. This paper presents a case of the welfare facility remodeled using Don-Yi middle school in Okcheon-Gun, Chungcheongbuk-Do and propose the unit care composition. The main contents is composed of posts, beams floors, stairs. Masonry infill walls and windows ware improved. Corridors were placed. A classroom were divided into 2 rooms with the Korean traditional heating system(on-dol) for four. Other conveniences were designed for a cafeteria, recreation, a restroom as space required. It is effective to utilize the closed school that has magnificent views and orientation, space construction. The Unit-care system is proposed by 4 types developments.

Development of A Validation System For Automatic Radiopharmaceutical Synthesis Process Using Network Modeling (방사성의약품 합성 프로세스 검증을 위한 네트워크 모델링)

  • Lee, Cheol-Soo;Heo, Eun-Young;Kim, Jong-Min;Kim, Dong-Soo
    • IE interfaces
    • /
    • v.24 no.3
    • /
    • pp.187-195
    • /
    • 2011
  • The automatic radiopharmaceutical module consists of several 2-way valves, couple of syringes, gas supply unit, heating(cooling) unit and sensors to control the chemical reagents as well as to help the chemical reaction. In order to control the actuators of radiopharmaceutical module, the process is tabulated using spread sheet as like excel. Unlike the common program, a trivial error is too critical to allowed in the process because the error can lead to leak the radioactive reagent and to cause the synthesis equipment failure during synthesizing. Hence, the synthesis process has been validated using graphic simulation while the operator checks the whole process visually and undergoes trial and error. The verification of the synthesis process takes a long time and has a difficulty in finding the error. This study presents a methodology to verify the process algebraically while the radiopharmaceutical module is converted to the network model. The proposed method is validated using actual synthesis process.

An Evaluation of Thermal Stability of Raw Materials in the Vinyl Acetate Polymerization Process (비닐아세테이트 중합공정에서 원료물질의 열적 안정성 평가)

  • Lee, Keun-Won;Han, In-Soo;Lee, Jung-Suk
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.61-65
    • /
    • 2010
  • Most of the chemical reactions performed in the chemical industry are exothermic, meaning that thermal energy is released during the reaction. It is also important to understand the thermal hazards such as thermal stabilities and runaway reactions, which are governed by thermodynamics and reaction kinetics of the mixed materials. The paper was described the evaluation of thermal behavior caused by an exothermic batch process in manufacture of the vinyl acetate resin. The aim of the study was to evaluate the thermal stabilities of raw materials with operating conditions such as a reaction inhibitor, heating rate, reaction atmosphere and the mount of methanol charged in the vinyl acetate polymerization process. The experiments were performed in the differential scanning calorimeter(DSC), C 80 calorimeter, and thermal screening unit($TS^u$). It was suggested that we should provide the thermal characteristics for raw materials to present safe precautions with operating conditions in the vinyl acetate polymerization process.

The Kitchen furniture design Based on Stored items of Cooking Area in 40-pyung type apartment Houses (40평형 아파트 식생활용품 수납실태에 따른 부엌가구디자인)

  • Kim, Gi-In;Kim, Sun-Joong;Kwon, Myung-Hee
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.304-309
    • /
    • 2009
  • The purpose of this study is to develop kitchen furniture design for 40-pyung apartment Houses based on stored item of Cooking, Eating and Utility Area. The research data is gotten at a field study of stored items of Cooking, Eating and Utility Area and depth interview. The results of this study were as follows; 1)The kitchen furniture the preparation unit and the sink, the kitchen table, the heating unit and the service table, arranged at the tall storage. 2)The total bulk considered and holding volume ($2.7m^3$) with ground clearance (40%) planned with about $4.21m^3$. 3)Assumed at height and 162cm did a lower part height with 860mm and the upper depth 340mm, did with 700mm where raises. the storage the ceiling which raises will select and considered and with 2200mm did. 4)Arrangement of the kitchen the kitchen form which is an open type (L/DK or L.D.K) arranged many in forms of letter.

  • PDF