• Title/Summary/Keyword: Heating Device

Search Result 478, Processing Time 0.115 seconds

펠티어 소자를 이용한 다공성 나노패턴의 사출에 대한 연구 (Injection molding using porous nano-scale patterned master with Pettier devices)

  • 홍남표;권종태;신홍규;서영호;김병희
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 춘계학술대회 논문집
    • /
    • pp.513-516
    • /
    • 2008
  • We have replicated nanopillar arrays using injection molding process of active heating and cooling method by several peltier devices. The injection melding has a high accuracy ed good reproducibility that are essential for mass production at low cost. Conventional molding processes widely use the water-based mold heating and air cooling methods. However, in case of replication for nano-patterned structures, it caused several defects such as air-flow mark, non-fill, sticking and tearing. In this study, periodic nano-scale patterns are replicated by using injection molding with Peltier devices. Porous nano-scale patterns, which have pore diameter range from 120nm to 150nm, were fabricated by using anodizing process. Periodic nano-pore structures ( $20mm\;{\times}\;20mm$) were used as a mold stamp of injection molding. Finally, PMMA with nanopillar arrays was obtained by injection molding process. By using the Peltier devices, the temperature of locally adiabatic molds can be dramatically controlled and the quality of the molded patterns can be slightly improved.

  • PDF

일반공조 시스템 대비 축열조와 연동된 수직밀폐형 지열히트펌프의 냉난방 에너지 성능 및 경제성 분석 (Cooling and Heating Energy Performance and Cost Analysis of Vertical Closed-loop Geothermal Heat Pump Coupled with Heat Storage Tank Compared to Conventional HVAC System)

  • 김민지;도성록;최종민;이광호
    • 대한건축학회논문집:구조계
    • /
    • 제34권11호
    • /
    • pp.81-87
    • /
    • 2018
  • Among various types of geothermal heat pump systems, Vertical Closed-Loop Geothermal Heat Pump (VGSHP) has received increasing attention due to a variety of advantages such as the potential to be installed in a relatively small space and improved energy efficiency. In this research, the performance of VGSHP system coupled with heat storage tank was evaluated, by analyzing operational behavior of heat storage tank, the variations of heat pump energy performance due to the connection with heat storage tank, part load ratios characteristics of heat pump and the corresponding energy cost, compared to chiller and boiler based conventional system. The results of this study showed that the VGSHP system coupled with heat storage tank showed an energy saving effect of about 18% for cooling and about 73% for heating, and annual heating/cooling energy cost reduction of 43,000,000 KRW ($ 39,000), compared to the conventional air conditioning system. In addition, after considering both energy cost and initial investment cost including equipment, installation and auxiliary device expenses, payback period of approximately 11.8 years was required.

동절기 수박 접목묘의 안정적 생산을 위한 나노탄소섬유적외선 램프의 난방효과에 대한 적정 설치간격 (Proper Installation Distance for Heating Effect of Nano-Carbon Fiber Infrared Heating Lamp for Stable Production of Watermelon Grafted Seedlings in Winter Season)

  • 김혜민;정현우;황희성;황승재
    • 생물환경조절학회지
    • /
    • 제31권1호
    • /
    • pp.8-13
    • /
    • 2022
  • 본 연구는 동절기 공정육묘장의 수박 플러그 묘 생산 시, 난방 에너지 절감에 유리한 난방장치인 나노탄소섬유 적외선 난방등의 효율적인 사용을 위한 적정 전력과 설치 간격을 구명하기 위해 수행되었다. 유리온실 내 소형 베드 6개를 플라스틱 필름으로 구획을 나누었으며, 100cm 높이에 700W와 900W 난방등을 설치하였다. 난방등은 설치 간격을 각각 중앙 1개(Control), 60cm 간격(2개), 40cm 간격(3개)으로 설치하였다. 나노탄소섬유 적외선 난방등을 점등한 후 대조구를 제외한 모든 처리에서 설정한 야간 기온(20℃)을 유지하였다. 엽온은 난방등 설치 간격이 좁을수록 빨리 상승하는 경향을 보였다. 나노탄소섬유 적외선 난방등을 사용함에 따른 처리구간 수박 접목묘의 생육에는 뚜렷한 차이가 없었으나, 엽장과 엽폭은 700W 난방등에서 설치 간격이 짧을수록 길어지는 경향을 보였으며, 700W 난방등을 40cm 간격으로 설치하였을 때 묘의 충실도가 높은 값을 나타내는 것을 확인할 수 있었다. 따라서 야간 기온 유지와 묘의 충실도를 고려하였을 때, 700W 난방등을 40cm 간격으로 설치하는 것이 수박 접목묘를 생산하는데 경제성을 고려하여 효율적인 나노탄소섬유 적외선 난방등의 전력과 설치 간격으로 판단된다.

Zig-Zag 결선 및 Open-Delta 방식을 이용한 새로운 고조파 저감장치의 개발 (Development of the New Hormonic Eliminating Device Using Zig-Zag Connection and Open-Delta Mode)

  • 이성호;김기성;유상봉
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.169-174
    • /
    • 2005
  • 지금까지의 고조파 필터는 중성선 리액터와 지그재그결선의 영상 고조파 전류를 제거하였으나, 부하율에 따라 고조파 저감율이 변하여 경부하에서는 고조파 저감율이 낮아지는 특성이 있고, 중성선 리액터 과열로 중성선 단선 위험의 문제가 발생하였다. 본 Zig-Zag 결선 및 Open Delta 방식을 이용한 새로운 고조파 저감장치(HANOS)는 Zig-Zag 결선의 Core Block내에 추가로 Open Delta 방식을 결선하여 중성선에 연결함으로써 중성선에 흐르는 영상 고조파 전류가 과열 없이 안전하게 제거되는 것을 시험 분석한 결과로 증명하였다.

의료기기의 발전을 위한 탄소소재의 활용 (Application of Carbon Materials for the Development of Medical Devices)

  • 곽영곤
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.23-28
    • /
    • 2023
  • Carbon materials are widely used in many areas of our lives. A fiber having a carbon content of 90% or more obtained by heating an organic fiber precursor is referred to as a "carbon fiber". Carbon fibers are currently used in the medical market to manufacture radiation transmission device parts, artificial joints, and medical aids, as many developments have been made to utilize carbon fibers' characteristics such as light weight, radiation permeability, biocompatibility, high strength, high heat resistance, thermal conductivity, and electrical conductivity. In order to maintain body temperature and increase immunity in long-lasting nuclear medical examination and treatment through the idea of convergence of carbon materials and radiation technology, the quality of medical services can be improved by utilizing carbon materials. We should be aware of the domestic carbon-based medical device industry and make efforts to contribute to the development of medical devices. As a radiation expert, we should try to use our skills and experience to find items that can be fused with medical devices to develop various nuclear medical examination fields and radiographic examination fields that can be widely applied. We should actively engage in future technology development and carbon material research to strengthen the global competitiveness of the domestic medical device industry and improve the quality of medical services.

  • PDF

국부가열장치를 이용한 온간 무금형 점진 성형 (Warm Incremental Forming with Local Heating Apparatus)

  • 김상우;이영선;권용남;이정환
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 추계학술대회 논문집
    • /
    • pp.349-353
    • /
    • 2008
  • A fundamental study on warm incremental forming of a magnesium alloy sheet has been carried out. In order to enhance the incremental formability of the magnesium alloy sheet, a local heating device was newly designed and manufactured. Through the incremental forming tests of AZ31 under various forming conditions, the effects of process parameters such as the temperature, feeding depth per cycle, and inclination angle on the incremental formability of AZ31 were investigated. In addition, conventional FLDs at elevated temperatures were constructed experimentally and applied to predict the forming failure.

  • PDF

열전소자를 이용한 가정용 의류 건조기의 성능에 관한 실험적 연구 (A Study on the Performance of Home Clothes Dryer using Thermoelectric Module)

  • 이민재;공상운;김종수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2073-2078
    • /
    • 2007
  • This study was performed to develop a dryer for home clothes using thermoelectric module. The thermoelectric module was used as a heat source and a dehumidification device because it has heating part and cooling part at once. To design for maximizing the energy efficiency and the rate of dehumidification, the parameters of the dryer using thermoelectric module are heat capacity and air flow rate. This study showed that the thermoelectric module can be used in the clothes dryer and energy efficiency of clothes dryer be better than that of electric heating dryer.

  • PDF

지열히트펌프의 작동시간 경과에 따른 COP 변화에 대한 연구 (Study on COP Variations with the duration of Ground Source Heat Pump Systems Operation)

  • 이용규;백남춘;윤응상
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.198.2-198.2
    • /
    • 2010
  • In this study, the COP variation with the duration of Ground Source Heat Pump (GSHP) systems operation was analyzed by experiment. This experimental facility was installed in residential house as a back-up device of solar thermal heating system. The capacity of heat pump is 2.5 kW with a vertical bore hole of 150m depth. The COP of GSHP is varied, depending on the ground temperature which is used as a heat source. The ground heat source temperature influencing heating COP is the soil or rock temperature which adjoin with geo-source heat exchanger. This temperature is decreased rapidly according to the operation duration of heat pump. As a result, COP of GSHP is decreased to 3 in one hour of continuous operation time.

  • PDF

직선화된 와이어의 버 없는 전단기 개발에 관한 연구 (The Development of Burrless Shearing System for Straightened Wire)

  • 조준원;김웅겸;김헌영;김병희
    • 산업기술연구
    • /
    • 제25권B호
    • /
    • pp.121-126
    • /
    • 2005
  • Micro wires manufactured by the straightening process are used in the BT(Bio-Technology), IT(Information-Technology), NT(Nano-Technology). We have developed a novel wire straightener which uses the direct heating method(DHM) for straightening the micro wire and shearing device for burr-less cutting. In this study, we confirm the tendency of micro wire after the shearing process. It is impossible to remove the burr in the shearing process. However, the embodiment of minimum burr size after the shearing process is the best in-process method. In order to minimize the burr size, we have accomplished the various experiment condition such as the U-groove, the effect of the counter punch, the shear angle, clearance.

  • PDF

NBI용 필라멘트 전원공급 장치를 위한 풀-브리지 DC/DC 컨버터 (Full-Bridge DC/DC Converter for NBI Filament Power Supply)

  • 전범수;이세형;이희준;신수철;이승교;원충연
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.32-39
    • /
    • 2011
  • FPS(Filament Power Supply), one of the KSTAR NBI(Neutral Beam Injections) is implemented by full-bridge DC/DC converter. NBI heating device for KSTAR(1.5MW) is developed for heating an ion source of plasma in KSTAR tokmak. The full-bridge DC/DC converter is applied to FPS for isolation with input and output. And FPS is operated with PWM control method which is the most usual method. In this paper, NBI FPS of 4.8kW is simulated by using the PSIM 6.0. And the full-bridge DC/DC converter using IGBTs is fabricated to demonstrate it. The processor DSP 28335 is implemented for digital control.