• 제목/요약/키워드: Heating Characteristics

검색결과 2,423건 처리시간 0.038초

난방모드 시 $CO_2$ 지열히트펌프의 내부열교환기에 대한 운전특성 (Operating Characteristics of Internal Heat Exchanger for $CO_2$ Geothermal Heat Pump in the Heating Mode)

  • 김재덕;이상재;김선창;김영률
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1226-1231
    • /
    • 2009
  • This paper presents operating characteristics of internal heat exchanger(IHX) for $CO_2$ geothermal heat pump in the heating mode. Mass flow rate of $CO_2$, inlet temperatures of $CO_2$ at high and low pressure side were selected as main effect factors by using fractional factorial DOE(Design of Experiments). And RSM(Response Surface Method) was used in optimization phase. The results show that heat transfer rate of IHX increases when either inlet temperature of low pressure side decreases or inlet temperature of high pressure side increases. Effectiveness of IHX increases with increasing of inlet temperature of either high pressure side or low pressure side. Finally, performance contour map was provided over the operation ranges of the main design factors.

  • PDF

실별제어 온수분배기의 유량분배 특성 (A Flow Quantity Distribution Characteristics of the Hot Water Header for Individual Room Control System)

  • 성순경
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.175-180
    • /
    • 2008
  • Flow quantity to supply to a coil in floor heating system is important to achieve comfortable indoor air condition in the winter season. The hot water header is used to distribute the water into the coil. Experimental study has been performed using the water header that have 5 branches consisted of flow control valves and automatic shut-off valves. Each branch line connected it with X-L pipe. Experimental tests accomplished it to investigate the flow distribution characteristics of the hot water header. Experimental results show that the selection of the pump head and differential pressure are very important to save running energy of the system, and high differential pressure needs more friction loss in the case of suitable differential pressure for balancing of the header.

호텔, 병원, 업무용 건물의 에너지 부하 특성 비교 (Comparison of Energy Demand Characteristics for Hotel, Hospital, and Office Buildings in Korea)

  • 박화춘;정모
    • 설비공학논문집
    • /
    • 제21권10호
    • /
    • pp.553-558
    • /
    • 2009
  • Energy demand characteristics of hotel, hospital, and office building are compared to provide guidelines for combining building in community energy system design. The annual, monthly, and daily energy demand patterns for electricity, heating, hot water and cooling are qualitatively compared and important features are delineated based on the energy demand models. Key statistical values such as the mean, the maximum are also provided. Important features of the hourly demand patterns are summarized for weekdays and weekends. Substantial variations in both magnitudes and patterns are observed among the 3 building types and smart grouping or combination of building type and size is essential for a successive energy supply.

배플 플레이트를 갖는 열교환기의 열전달 및 압력강하에 관한 연구 (A study on heat transfer characteristics and pressure drop of heat transfer by baffle cut rate)

  • 배성우;최순호;윤석훈;오철
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.172-177
    • /
    • 2005
  • The object of this experiment is comparing heat transfer performance and pressure drop characteristics by baffle cut rate, fluid velocity and heating temperature. Experiments were carried out in cross flow heat exchanger with water as a working fluid. In this experiment, baffle cut rate is 30%, 40%, 50%, velocity is 0.5m/s, 1.0m/s, 1.5m/s, and heating temperature is $30^{\circ}C$, $40^{\circ}C$, $50^{\circ}C$. An experimental device to measure the heat transfer coefficient was constructed. The experimental result were obtained for the fully developed turbulent flow of water in tube on the condition of uniform heat flux.

  • PDF

Half-Bridge Series Resonant Inverter for Induction Cooking Applications with Load-Adaptive PFM Control Strategy

  • Kwon, Young-Sup;Lee, Byoung-Kuk;Yoo, Sang-Bong;Hyun, Dong-Seok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.1018-1023
    • /
    • 1998
  • This paper presents an effective control scheme incorporated in the voltage-fed half-bridge series resonant inverter for induction heating applications, which is based upon a load-adaptive tuned frequency tracking control strategy using PLL(Phase Locked Loop) and its peripheral control circuit. The proposed control strategy ensures a stable operation characteristics of overall inverter system and ZVS(Zero Voltage Switching0 operation in spite of sensitive load parameters variation as well as power regulation, specially in the non-magnetic heating loads. The simulation results and the performance characteristics in the steady-state are shown as compared with the experimental results for a prototype induction cooking system rated at 1.2kW.

  • PDF

Thermal Effects of Single Silicon Tip Emitters with Various Tip Radii

  • Lee, Jong-Duk;Oh, Chang-Woo;Park, Jae-Woo;Park, Byung-Gook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.681-684
    • /
    • 2002
  • To investigate thermal effects of silicon field emitter, we fabricated and characterized single silicon tips with various tip radii, which generate different joule heating. Through I-V and stability tests, the changes of emission characteristics and tip structures due to different tip heating were observed and discussed. From the results, we confirmed that the changes of emission characteristics due to thermal effects in silicon emitter could occur at relatively small emission currents and concluded that the thermal effects should be also considered under normal operation condition above 1 ${\mu}A$.

  • PDF

과전류에 의해 열화된 비닐코드의 특성 분석 (The characteristics analyses of deteriorated PVC insulated flexible cords by over-current)

  • 김향곤;최충석;김동욱;정현상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.489-492
    • /
    • 2003
  • In this paper, we experimented on the deterioration process of power supply cords and analyzed the heating temperature of each part of those cords. We also analyzed the surface states, metallurgical structures surface structures and compositions of the wire melted by over-current. In the results of the analyses, the covering began to be deteriorated from the inside. The heating temperature of extension cord was higher than that of plug body. The dendrite structures appeared at the melted wire. By the SEM and EDS analyses, the dendrite structure showed the growth of copper oxide. We found out the characteristics of PVC insulated flexible cords by over-current from the above experiments and analyses. These results may be useful data in the analyses of deterioration causes of power supply cords.

  • PDF

저항가열원에 의한 물질의 증발특성(I) (Evaporation characteristics of materials from resistive heating sources(I))

  • 정재인;임병문;문종호;홍재화;강정수;이영백
    • 한국표면공학회지
    • /
    • 제24권1호
    • /
    • pp.25-30
    • /
    • 1991
  • The evaporation characteristics of Ag, Al, Au, Cr. Cu, In, Mg, Mn, Pb, Pd, Si, SiO, Sn, Ti and Zn with the various resistive heating sources have been studied. The employed sources are refractory metal (Mo, Ta and W) boats, W-wire, ceramic (usually Al2O3)-coated and -barriered refractory metal boats, and special boats such as baffled boats and intermetallic boats (nitride compound and graphite). We investigated the melting mode, evaporation rate at a specific power, and lifetime of the sources. A special boat holder is also discussed which is needed to cool the sources at a large heat capacity.

  • PDF

태양열과 가스 연소열을 적용한 복합 태양열 흡수기의 열특성 연구 (Thermal Characteristics of Hybrid Solar Receiver using a Solar and Combustion heating)

  • 강명철;김진수;강용혁;윤환기;유창균;이상남
    • 신재생에너지
    • /
    • 제2권4호
    • /
    • pp.33-38
    • /
    • 2006
  • The Dish/Stirling system with the Stirling engine is currently used to convert solar energy directly to electrical energy. Successful operation of dish/Stirling system is supported by hybrid system, which will allow continuous operation driven by solar and combustion heating. The hybrid Receiver has to be provided with an additional combustion system. The heat pipe receiver and conbustion system were manufactured and tested for thermal characteristics of receiver. Maximum temperature difference along the heat pipe surface is $200^{\circ}C$. Emission measurements showed low NOx values of 28 to 46 ppm and very high CO values of 18 to 201 ppm.

  • PDF

지중열교환(地中熱交換) 온실(溫室)의 축열(蓄熱) 및 방열(放熱) 특성(特性) (Characteristics of the Stored and Released Thermal Energy in Plastic Greenhouse with Underground Heat Exchange System)

  • 이종호;박승제;김용현;김철수;이중용
    • Journal of Biosystems Engineering
    • /
    • 제19권3호
    • /
    • pp.222-231
    • /
    • 1994
  • The efficient use of solar energy for greenhouse heating is one of the most obvious applications to save the heating energy for greenhouse culture. To increase the efficiency of solar energy utilization in plastic greenhouse, underground heat exchange system was installed. Characteristics of the stored and released thermal enery in plastic greenhouse with underground heat exchange system was analyzed. The average stored and released thermal energy in this system were 1,484 $kJ/m^2$ day and 555 $kJ/m^2$ day, respectively. The average coefficient of performance of heat exchange system was found to be 2.86. Also an attempt was made to predict the air temperature in plastic greenhouse. The agreement between the results of prediction and that of measurement was relatively good.

  • PDF