• Title/Summary/Keyword: Heating Characteristics

Search Result 2,435, Processing Time 0.036 seconds

Generation characteristics of transparent BIPV module according to temperature change (건물일체형 투명 모듈의 온도 변화에 따른 발전 특성)

  • Park, Kyung-Eun;Kang, Gi-Hwan;Kim, Hyun-Il;Yu, Gwon-Jong;Jang, Dae-Ho;Lee, Moon-Hee;Kim, Jun-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.210-211
    • /
    • 2007
  • Amid booming PV(photovoltaic) industry, BIPV(Building Integrated PV) is one of the best fascinating PV application technologies. To apply PV in building, variable factors should be reflected such as installation position, shading, temperature effect and so on. Especially a temperature should be considered, for it affects both electrical efficiency of PV module and heating and cooling load in building. Transparent PV modules were designed as finished material for spandrels are presented in this paper. The temperature variation of the modules with and without air gap and insulation were compared and analyzed. The results showed that the module with air gap and insulation has a much larger temperature variation than another transparent module. The temperature of the module reached by 55degree C under vertical irradiance of lower 500$W/m^2$. And the temperature difference between these modules was about 15degree C. To analyze the output performance of module according to temperature variation, separate module was manufactured and measured by sun-simulator. The results showed that 1 degree temperature rise reduced about 0.45% of output power.

  • PDF

Electrical/Mechanical Diagnosis of Local Deterioration in 600V Shielded Twist Pair Cable in a Nuclear Power Plant (원전용 600V 차폐 꼬임쌍선 케이블의 국부열화에 대한 전기적/기계적 진단)

  • Park, Myeongkoo;Kim, Kwangho;Lim, Chanwoo;Kim, TaeYoon;Kim, Hyunsu;Chai, Jangbom;Kim, Byungsung;Nah, Wansoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.203-210
    • /
    • 2017
  • In this paper, we propose a electrical/mechanical method to effectively diagnose the local deterioration of a 10m long power shielded twist pair cable defined by the American Wire Gauge (AWG) 14 specification using electrical/mechanical methods. The rapid deterioration of the cable proceeded by using the heating furnace, which is based on the Arrhenius equations proceeds from 0 to 35 years with the deteriorated equivalent model. In this paper, we introduce a method to diagnose the characteristics of locally deteriorated cable by using $S_{21}$ phase and frequency change rate measured by vector network analyzer which is the electrical diagnostic method. The measured $S_{21}$ phase and rate of change of frequency show a constant correlation with the number of years of locally deteriorated cable, thus it can be useful for diagnosing deteriorated cables. The change of modulus due to deterioration was measured by a modulus measuring device, which is defined by the ratio of deformation from the force externally applied to the cable, and the rate of modulus change also shows a constant correlation with the number of years of locally deteriorated cable. Finally, By combining the advantages of electrical/mechanical diagnostic methods, we can efficiently diagnose the local deterioration in the power shielded cable.

A Novel Utility AC Frequency to High Frequency AC Power Converter with Boosted Half-Bridge Single Stage Circuit Arrangement

  • Saha, Bishwajit;Kwon, Soon-Kurl;Koh, Hee-Seog;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.387-390
    • /
    • 2006
  • This paper presents a novel soft-switching PWM utility frequency AC to high frequency AC power conversion circuit Incorporating boost-half-bridge inverter topology, which is more suitable and acceptable for cost effective consumer induction heating applications. The operating principle and the operation modes are presented using the switching mode and the operating voltage and current waveforms. The performances of this high-frequency inverter using the latest IGBTs are illustrated, which includes high frequency power regulation and actual efficiency characteristics based on zero voltage soft switching (ZVS) operation ranges and the power dissipation as compared with those of the previously developed high-frequency inverter. In addition, a dual mode control scheme of this high frequency inverter based on asymmetrical pulse width modulation (PWM) and pulse density modulation (PDM) control scheme is discussed in this paper in order to extend the soft switching operation ranges and to improve the power conversion efficiency at the low power settings. The power converter practical effectiveness is substantially proved based on experimental results from practical design example.

  • PDF

Examination on the Mounting Status of Cigar Lighter Receptacle for Vehicles and Analysis of its Tracking Characteristics (차량용 시가 잭의 장착 실태조사 및 트레킹 특성 분석)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.4
    • /
    • pp.28-33
    • /
    • 2009
  • This study examined the mounting status of cigar lighter receptacles for vehicles and analyzed the tracking phenomenon that occurs when foreign material entered a cigar lighter receptacle to obtain data for the analysis of accident investigation. Regardless of the vehicle's output, cigar lighter receptacles are mounted in a vehicle horizontally, vertically, or at tilting or inclined angle. The tilting type cigar lighter receptacle is much easier to use but current leakage resulting from foreign materials (coffee, beverages, water, etc.) falling into the cigar lighter receptacle may cause a fire to start. This study used a vehicle battery (DC 12V) as a power supply for the tracking test and configured its circuit in the same way as that of an electrical device in a vehicle. The tracking phenomenon that occurred in the standby mode of the vehicle exhibited a fine flame and an irregular occurrence of smoke. While this tracking phenomenon was occurring, the leakage current and the reaching distance of the flame were measured to be approximately 930mA and $20{\sim}50cm$, respectively. It is thought that the resultant flame may ignite toluene, dust, cigarettes, etc. It was observed that as the tracking progressed, the internal metal socket melted and a hole was created, the surface of which was also severely carbonized. In addition, the electrical resistance of the carbonized conductive path was measured to be approximately $30{\Omega}$. It is thought that this much resistance may cause local heating when leakage current flows and could ignite any nearby flammable material.

A Study on Characteristic Analysis of AC to AC Current-Fed Type High Frequency Resonant Inverter with High Power Factor (고역율 AC/AC 전류형 고주파 공진 인버터의 특성해석에 관한 연구)

  • Kim, Jong-Hae;Won, Jae-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.16-28
    • /
    • 2014
  • This paper presents a novel high-power-factor circuit topology of AC to AC current-fed type high frequency resonant inverter which includes the function of power factor correction(PFC) in the proposed inverter to operate the AC input block with high power factor. The proposed circuit topology of AC to AC current fed type high resonant inverter removes DC link electrolytic capacitor and has also the one of power factor correction(PFC) in the inverter circuit without an additional PFC circuit since the input current by constituting it in parallel as an unit inverter, which assumes the class-E high frequency resonant inverter of conventional current-fed type, flows in the form of the resultant current flowing through each constant current reactor($L_{d1}$, $L_{d2}$). The circuit analysis of proposed inverter is generally described by adopting the normalized parameters and the evaluation of its operating characteristics are conducted by using the parameters such as the ratio of switching and resonant frequency(${\mu}$), coupling coefficient(k) and so on. An example of procedure for circuit design based on the characteristic values obtained from the theoretical analysis is presented. To confirm the validity of the theoretical analysis, the experimental results are also presented. In the future, the proposed inverter shows it can be practically used as power supply system for induction heating application, DC-DC converter etc.

Design of High Efficiency Power Amplifier for Parametric Array Transducer using Variable Output Voltage AC/DC Converter (가변출력전압 AC/DC 컨버터를 이용한 파라메트릭 어레이 트랜스듀서용 고효율 전력증폭기의 설계)

  • Shim, Jae-Hyeok;Lee, Chang-Yeol;Kim, Seul-Gi;Kim, In-Dong;Moon, Won-Kyu;Lee, Jong-Hyeon;Kim, Won-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.364-375
    • /
    • 2014
  • Parametric array transducers are used for long-range and highly directional communication in an underwater environments. The power amplifiers for parametric array transducers should have sufficient linear output characteristic and high efficiency to avoid communication errors, system heating, and fuel problems. But the conventional power amplifier with fixed source voltage is very low efficient due to large power loss by the big difference between the fixed source voltage and the amplifier output voltage. Thus to solve the problems this paper proposes the high efficiency power amplifier for parametric array transducers. The proposed power amplifier ensures high linearity of output characteristic by utilizing the push-pull class B type amplifier and furthermore gets high efficiency by applying the envelope tracking technique that variable source voltage tracks the envelope of the amplified signal. Also the paper suggests the detailed circuit topology and design guideline of class B push-pull type amplifier and variable output voltage AC/DC converter. Its characteristics are verified by the detailed simulation and experimental results.

A syudy on electrochemical charcteristic of $Li_{1-x}Mn_{2}O_{4}$(0$\leq$x$\leq$0.075) ($Li_{1-x}Mn_{2}O_{4}$(0$\leq$x$\leq$0.075)의 전기화학적 특성연구)

  • 박종광;고건문;김민기;이남재;임석진;한병성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.444-447
    • /
    • 2000
  • The spinel L $i_{1-x}$ M $n_2$ $O_4$has been synthesized by the solid-state reaction. L $i_{l-x}$M $n_2$ $O_4$which includes a mixture of LiOH . $H_2O$ and Mn $O_2$prepared by preliminary heating at 35$0^{\circ}C$ for 12hr. L $i_{l-x}$M $n_2$ $O_4$fired at temperature range from 75$0^{\circ}C$ for 48hr. The structure and the electrochemical characteristics of spinel to L $i_{1-x}$ M $n_2$ $O_4$which is fabricated by changing sintering condition from starting materials are investigated. The cyclic voltammetric measurement was performed using 3 electrode cells. Electrode specific capacity and cycle life behavior were tested in a 3.0~4.2V range at a constant current density of 0.45mA/c $m^2$. To improve the cycle performance of spinel L $i_{l-x}$M $n_2$ $O_4$as the cathode of 4V class lithium secondary batteries, spinel phases L $i_{1-x}$ M $n_2$ $O_4$were Prepared at various lithium. The results showed that discharge capacity of L $i_{l-x}$M $n_2$ $O_4$varied at lithium quantity decrease with increasing lithium add quantity. The discharge capacities of L $i_{0.925}$M $n_2$ $O_4$and LiM $n_2$ $O_4$revealed 108 and 117mAh/g, respectively.spectively.y.

  • PDF

Infant target facilities and facilities for children in elementary school Comparison and Improvement of Indoor Air Quality for Research (영유아 대상 시설의 실내공기질 특성 비교 및 개선방안에 대한 연구)

  • Seo, Byong-Won;Lee, Ju-Hwa;Park, Ji-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.591-601
    • /
    • 2013
  • In modern society, we are living indoor at 80 - 90 % or more of the day, therefore most people are exposed to unconscious indoor air pollutants by various causes. When mother and infant, whose level of immunity are weak, are exposed to polluted indoor air, respiratory diseases and atopy can occur by the growth of bacteria. Therefore, appropriate indoor air quality management is important especially at nursery, elementary school and postpartum clinic etc. In this study, we compared the characteristics of the indoor air qualities of primary school facilities and infant facilities. In this study, seasonal effects were investigated. Also the effects of individual activity area were studied for indoor air quality. During summer season(May-August), the air qualities of each 16 elementary school and nursery school were investigated. During winter season(October-december), the air qualities of each 10 elementary school and nursery school were investigated. As a result, during winter season in 10 of 16 nursery school, $CO_2$ concentration exceeded regulation level of 1000 ppm. This resulted from the operation of heating system and poor ventilation. Also the air quality of all parameters during winter season were worse than during summer, maybe due to poor ventilation. Except HCHO, the concentrations of other parameters were higher in nursery school. This seems to result from relatively low individual activity area of nursery school than elementary school. From this research, more strong regulation for ventilation and installation of air purifier should be implemented.

The Distinctive Feature of Acupuncture Treatment in ZhangJinYoPian(藏珍要編) (19세기 조선 침구서 장진요편의 침법 연구)

  • Oh, Jun-Ho
    • Korean Journal of Acupuncture
    • /
    • v.27 no.1
    • /
    • pp.159-168
    • /
    • 2010
  • Objective: ZhangJinYoPian(藏珍要編, ZJYP) is a book witten by Song-WooGe in the late 19th century. While Korea has lost this book to tell us Korea traditional acupuncture treatment in the late 19th century, This book appeared as a manuscript in Japan. There is no reaserch or study carried out for this book. Furthermore, a few people know existence of this book. So I analyzed acupuncture treatment of the ZJYP and sort out the distinctive feature of it. Method: For that, I studied bibliographic information of this book and classified contents of it into three parts - medical thought, needle manipulation and acupoint selection to consider it's caracteristics. Results and Conclusions: 1. The author of ZJYP thought that weakness of good power in the body and strongness of evil power out of the body cause a disease. so Doctor should examine quality of both to care patient's pain. 2. The author of ZJYP thought that needle manipulation is one of the most important thing. Doctors can use needle manipulation to control patient condition. Especially, he suggested cooling and heating manipulation except reinforcement and reduction. 3. He stressed viscera and bowels. he located viscera and bowels theory in front of the book to explain relationship of these. It shows us that ZJYP maintained academic characteristics of acupuncture in Chosun-Korea. 4. While He minimized the number of acupoints used in treatment, he multiplied its combination. He selected one or two acupoints from each meridian pathway. It include Eight Confluent points(八脈交會穴). But these points were used in different ways to control the viscera and bowels, not to care the eight extra meridians.

A study on the heat transfer characteristics of swirling flow in a circular sectioned $180^{\circ}C$bend with uniform heat flux (균일 열플럭스가 있는 $180^{\circ}C$ 원형단면 곡관의 선회유동 열전달특성 연구)

  • Lee, Sang-Bae;Gwon, Gi-Rin;Jang, Tae-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.615-627
    • /
    • 1997
  • An experiment was performed to local heat transfer coefficient and Nusselt number in the circular duct of 180.deg. bend for Re=6*10$^{4}$, 8*10$^{4}$ and 1*10$^{5}$ at swirling flow and non-swirling flow conditions. The test tube with circular section was made by stainless which has curvature ratio 9.4. The wall of test tube was heated directly by electrical power to 3.51 kw and swirling motion of air was produced by a tangential inlet to the pipe axis at the 180 degree. Measurements of local wall temperatures and bulk mean temperature of air are made at four circumferential positions in the 16 stations. The wall temperatures show particularly reduced distribution curve at bend for non-swirling flow but this effect does not appear for swirling flow. Nusselt number distributions for swirling flow which was calculated from the measured wall and bulk temperatures were higher than that of non-swirling flow. Average Nusselt number of swirling flow increased about 90 ~ 100% than that of non-swirling flow whole through the test tube. The Nu/N $u_{DB}$ values at the station of 90.deg. for non-swirling flow and swirling flow are respectively about 2.5 and 4.8 at Re=6*10$^{4}$. Also that is good agreement with Said's result for non-swirling flow. flow.