Development of Auxiliary Heater to Improve Korean Medical Evacuation Helicopter Winter Operational Capability

  • Kim, Se Un;Koo, Jeong Mo;Seo, Jeong Mi;Jeong, Won Chae
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.6
    • /
    • pp.10-17
    • /
    • 2020
  • The Korean medical evacuation helicopter was developed based on the Korean Utility Helicopter (hereafter referred to as 'Surion'). It uses an auxiliary power unit and engine for heating during winter operation. The helicopter maintains the internal temperature of the aircraft using its bleed air to satisfy its operational capability. However, due to the air inflow through the gap between the aircraft skin and door, additional heating for operating the portable medical equipment and preventing hypothermia in evacuated patients is required. Accordingly, an electric auxiliary heater was developed for additional heating during winter operation, and environmental, durability, and performance tests were conducted per MIL-STD-810G and MIL-STD-461F. The auxiliary heater was verified per the tailored airworthiness certification criteria.

A Study on Risk Analysis and Acident Prevention Heater Interlock By-pass (Heater interlock by-pass로 인한 위험분석 및 사고방지에 대한 연구)

  • Son Jae-geun;Park Kyo-Shik;Kang Tae-Yeon;Yeo Yeong-Koo
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.24-27
    • /
    • 2003
  • In this paper it was investigated 15 heaters of CDU plant heater, NCC plant heater, CO plant heater, Aromatic plant heater and so on while running in our country. It was also analysed the standard of operation procedure, the action in alarm, the interlock system, the operating situation of the interlock by-pass and major accident about the heater and so on. This paper presents the installation of the on-line monitoring, the additional installation of the local pressure gauge and temperature gauge, the check in starting operation,'the management of the interlock by-pass, the change of manufacturer causing the disorder of instrument sensor, the management method of DCS alarm for methods of the interlock prevention and facilities improvement. It was few information about the heater interlock in the inside and outside of the country We mainly have studied with reflecting the opinion of the operator and manager on site, the sheet of process trouble and operation procedure and so on. we think that the accident relating to the interlock will significantly reduce if the companies apply the conclusion of this study(i.e. methods of the interlock prevention and facilities improvement).

  • PDF

Micromachined DNA Manipulation Device Using Circular Multi-Electrodes (원형 다중전극을 이용한 DNA 조작소자)

  • Moon, Sang-Jun;Yun, Jae-Young;Lee, Seung-S.;Nam, Hong-Kil;Chi, Yeun-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.7
    • /
    • pp.1071-1075
    • /
    • 2003
  • In this paper, we present a DNA manipulation device in the reaction chamber, which consists of a center electrode and circular outer electrodes of a reaction unit. The charged bio-molecules, DNA, are manipulated by the charge of the electrode in reaction unit. Controlling the induced dynamic electric field between the center electrode and the outer electrodes, concentration / repulsion / manipulation of bio-molecules are enabled at a periphery of electrode. Concentration of the fluorescent DNA at the center electrode is observed by applying +2V. Subsequently, applying -2V, the concentrated DNA is repelled rapidly from the center electrode, which makes dispersion completely in 0.5second. Furthermore, repeated applying +1V/-1V every 5 seconds at each outer electrode, we can circulate the DNA. We also investigate a micro-heater and sensor for DNA manipulation and reaction temperature. The coefficient of heat-resistance and heater temperature characteristic is 0.0043 and 100$^{\circ}C$/sec, respectively.

The Importance of Corrosion Control and Protection Technology in the Refinery

  • Kim, Byong Mu;Oh, Sung Lyong
    • Corrosion Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.112-119
    • /
    • 2007
  • This paper presents the importance of corrosion control and protection technology with a real case study of heater tube rupture damaged by High temperature H2S-H2 corrosion in the refinery. The heater was operated at the Hydrocracking unit and the operation temperature and pressure was $340^{\circ}C$ and $18kg/cm^{3}$ respectively. Top side of the convection tube was thinned by high temperature hydrogen sulfide and hydrogen gas as a uniform corrosion and finally ruptured under operation pressure. Damaged area (Convection tube zone) was blocked by protection wall, so it was impossible to inspect with conventional nondestructive examination. Instead the elbow area which is out of the protection wall was inspected regularly to evaluate the corrosion rate of convection tube indirectly. However the operation temperature and the phase of the process stream was different between inside the chamber and outside the chamber. As a result, it caused severe corrosion to the horizontal convection tube inside the chamber comparing to the elbow outside the chamber. Finally convection tube was corroded more rapidly than the elbow and ruptured after 13 years operation. Because of the rupture, the heater was totally burned and the operation was stopped for 3 months until it has been reconstructed. To prevent this kind of corrosion problem and accident, corrosion control should be strengthened and protection technology should be improved.

Heat Transfer Characteristics of DPH(Dual Pack Heater) in Electric and Fuel Cell(FC) Car (전기 및 연료전지자동차용 DPH 난방장치개발연구)

  • Roh, Hong-Koo;Lim, Kyung-Bin;Noh, Jong-Ho;Lee, Young-Ki;Ko, Jun-Bin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1262-1266
    • /
    • 2009
  • The study aims to analyzed and identify the heat transfer characteristics of heating unit for car using experimental method in order to design DPH. The temperature comparison processes were done with various experimental conditions. In addition, the optimal conditions of DPH design were proposed as field test in real car, hot air flow, transient situation.

  • PDF

Characteristics of noise in HVAC duct for vehicle (차량용 공조덕트의 소음특성에 관한 연구)

  • Kim, Jae-Won;Kim, Jin-Min;Park, Jeong-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.529-534
    • /
    • 2003
  • Comprehensive study on the system, including blower and ducts, of HVAC device of a vehicle has been carried out for improvements of noise characteristics. The parameters of design improvements are concerned with geometric informations such as the shape of ducts and presence of a windshield window. Test results show that noise level increasing the following order: HV (HD) < V (D) < BH ${\sim}$ BHV (BHD) < B (B, H, V, D denote for blower, heater unit, vent duct, defrost duct, respectively). The effects of windshield glass on the noise level in the case of defrost mode are pronounced and the effects of the geometry of ducts on the overall HVAC noise prove to be not small.

  • PDF

Semiconductor wafer exhaust moisture displacement unit (반도체 웨이퍼 공정 배기가스 수분제어장치)

  • Chan, Danny;Kim, Jonghae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5541-5549
    • /
    • 2015
  • This paper introduces a safer and more power efficient heater by using induction heating, to apply to the semiconductor wafer fabrication exhaust gas cleaning system. The exhaust gas cleaning system is currently made with filament heater that generates an endothermic reaction of N2 gas for the removal of moisture. Induction theory, through the bases of theoretical optimization and electronic implementation, is applied in the design of the induction heater specifically for the semiconductor wafer exhaust system. The new induction heating design provides a solution to the issues with the current energy inefficient, unreliable, and unsafe design. A robust and calibrated design of the induction heater is used to optimize the energy consumption. Optimization is based on the calibrated ZVS induction circuit design specified by the resonant frequency of the exhaust pipe. The fail-safe energy limiter embedded in the system uses a voltage regulator through the feedback of the MOSFET control, which allows the system performance to operate within the specification of the N2 Heater unit. A specification and performance comparison from current conventional filament heater is made with the calibrated induction heater design for numerical analysis and the proof of a better design.

An Experimental Study on the Development and Possible Solution of Thermal Runaway Model of Electronic Moxibustion with System Error (전자뜸의 시스템 오류에 의한 열폭주 모델 구현 및 해결 방법에 관한 실험적 연구)

  • Lee, Byung Wook;Oh, Yong Taek;Jang, Hansol;Choi, Seong-Kyeong;Jo, Hyo Rim;Sung, Won-Suk;Kim, Eun-Jung
    • Korean Journal of Acupuncture
    • /
    • v.38 no.4
    • /
    • pp.282-289
    • /
    • 2021
  • Objectives : The purpose of this study is to construct a model of the possible thermal runaway of electronic moxibustion and to implement an appropriate risk management method. Methods : To reproduce the system error situation of the electronic moxibustion circuit equipped with microcontroller unit, temperature sensor and heater, a code was set to disable the signal input to temperature sensor and maintain "high" heating signal to heater. The temperature change of electronic moxibustion was compared between 3 types of heater module; module 1 consisting of a combination of heater+0 ohm+0 ohm resistance, module 2 consisting of a combination of heater+Polymeric Positive Temperature Coefficient (PPTC)+0 ohm resistance, and module 3 consisting of a combination of heater+PPTC+10 ohm resistance. The temperature change was measured using a polydimethylsiloxane (PDMS) silicone phantom. After maintaining surface temperature of the phantom at 31~32℃ for 20 seconds, electronic moxibustion was applied. After operating electronic moxibustion, the temperature change was measured for 660 seconds on the surface and 900 seconds at 2 mm depth. Results : Regardless of the module type, the time-dependent change in temperature showed a rapid rise followed by a gentle curve, and a sharp drop in temperature after reaching the maximum temperature about 10 minutes after the switching the moxibustion on. Temperature measured at the depth of 2 mm below the surface increased slower and to a lesser extent. Module 1 reached highest peak temperature with largest change of temperature at both depths followed by module 2, and 3. Conclusions : Through the combination of PPTC+resistance with the heater of electronic moxibustion, it is possible to limit the rise in temperature even with the software error. Thus, this setting can be used as an independent safety measure for the electronic moxibustion control unit.

Heat Transfer Performance of Plate Type Absorber with Surfactant

  • Yoon, Jung-In;M. M. A. Sarker;Moon, Choon-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.243-251
    • /
    • 2004
  • Absorption chiller/heater can utilize the unused energy of the daily life waste heat, the industry waste heat. the solar energy and the earth energy. These can contribute to energy savings. But the absorption chiller/heater has a demerit that the size of absorption chiller/heater is larger than that of the vapor compression type based on same capacity. In this study. the experimental apparatus of an absorber is manufactured as a plate. which is newly applied in an absorber. The experimental apparatus is composed of a plate type absorber. which can increase the heat exchange area per unit volume and thus facilitating to deeply investigate more detail features instead of that done by the existing type. i.e.. horizontal tube bundle type. The characteristics of heat transfer and refrigeration capacity are studied experimentally. The absorption enhancement by using surfactant is closely examined through the experiment and comparative figures are presented in quantitative and qualitative analysis.

Power System Design for Next Generation LEO Satellite Application (차세대 저궤도 소형위성 적용을 위한 전력시스템 설계)

  • Park, Sung-Woo;Park, Hee-Sung;Jang, Jin-Beak;Jan, Sung-Soo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.283-287
    • /
    • 2005
  • In this paper, one general approach is proposed for the design of power system that can be applicable for next generation LEO satellite application. The power system consists of solar panels, battery, and power control and distribution unit(PCDU). The PCDU contains solar array modules, battery interface modules, low-voltage power distribution modules, high-voltage distribution modules, heater power distribution modules, on-board computer interface modules, and internal DC/DC converter modules. The PCDU plays roles of protection of battery against overcharge by active control of solar array generated power, distribution of unregulated electrical power via controlled outlets to bus and instrument units, distribution of regulated electrical power to selected bus and instrument units, and provision of status monitoring and telecommand interface allowing the system and ground operate the power system, evaluate its performance and initiate appropriate countermeasures in case of abnormal conditions. We review the functional schemes of the main constitutes of the PCDU such as the battery interface module, the auxiliary supply module, solar array regulators with maximum power point tracking(MPPT) technology, heater power distribution modules, spacecraft unit power distribution modules, and instrument power distribution module.

  • PDF