• Title/Summary/Keyword: Heat transportation

Search Result 319, Processing Time 0.031 seconds

Orobol, A Derivative of Genistein, Inhibits Heat-Killed Propionibacterium acnes-Induced Inflammation in HaCaT Keratinocytes

  • Oh, Yunsil;Hwang, Hwan Ju;Yang, Hee;Kim, Jong Hun;Yoon Park, Jung Han;Kim, Jong-Eun;Lee, Ki Won
    • Journal of Microbiology and Biotechnology
    • /
    • v.30 no.9
    • /
    • pp.1379-1386
    • /
    • 2020
  • Acne is a chronic skin disease that typically occurs in the teens and twenties, and its symptoms vary according to age, sex, diet, and lifestyle. The condition is characterized by hyperproliferation of keratinocytes in the epidermis, sebum overproduction, excessive growth of Propionibacterium acnes, and P. acnes-induced skin inflammation. Interleukin (IL)-1α and IL-6 are predominant in the inflammatory lesions of acne vulgaris. These cytokines induce an inflammatory reaction in the skin in the presence of pathogens or stresses. Moreover, IL-1α accelerates the production of keratin 16, which is typically expressed in wounded or aberrant skin, leading to abnormalities in architecture and hyperkeratinization. Orobol (3',4',5,7-tetrahydroxyisoflavone) is a metabolite of genistein that inhibited the P. acnes-induced increases in IL-6 and IL-1α levels in human keratinocytes (HaCaTs) more effectively compared with salicylic acid. In addition, orobol decreased the IL-1α and IL-6 mRNA levels and inhibited the phosphorylation of inhibitor of kappa-B kinase, nuclear factor of kappa light polypeptide gene enhancer in B-cells inhibitor, alpha, and mitogen-activated protein kinase induced by P. acnes. Finally, the expression of Ki67 was decreased by orobol. Thus, orobol ameliorated the inflammation and hyperkeratinization induced by heat-killed P. acnes and thus has potential for use in functional foods and cosmetics.

Corrosion Failure Analysis of a Biogas Pipe (바이오가스 배관의 부식 파손 원인 분석)

  • Min Ji Song;Woo Cheol Kim;Heesan Kim;Jung-Gu Kim;Soo Yeol Lee
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.36 no.3
    • /
    • pp.153-160
    • /
    • 2023
  • The use of biogas is an industrially necessary means to achieve resource circulation. However, since biogas obtained from waste frequently causes corrosion in pipes, it is important to elucidate corrosion mechanisms of the pipes used for biogas transportation. Recently, corrosion failure occurred in a pipe which supplied for the biogas at the speed of 12.5 m/s. Pinholes and pits were found in a straight line along the seamline of the pipe. By using corrosion-damaged samples, residual thickness, microstructure, and composition of oxide film and inclusion were examined to analyze the cause of the failure. It was revealed that the thickness reduction of biogas pipe was ~0.11 mm per year. A thin sulfuric acid film was formed on the surface of the interior of a pipe due to moisture and hydrogen sulfide contained in a biogas. Near the seamline, microstructure was heterogeneous and manganese sulfide (MnS) was found. Pits were generated by micro-galvanic corrosion between the manganese sulfide and the matrix in the interior of the pipe along the seamline. In addition, microcracks formed along the grain boundaries beneath the pits revealed that hydrogen-induced cracking (HIC) also contributed to accelerating the pitting corrosion.

The Component Characteristics and the Distribution Channels for Forest Products Consumed as a Fuel in Kyeongseong City (Seoul) in 1929 (1929년 경성부(京城府)에서 소비(消費)된 임산연료(林産燃料)의 구성별(構成別) 특성(特性)과 유통(流通) 경로(經路))

  • Lee, Ki-Bong;Bae, Jae-Soo
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.3 s.160
    • /
    • pp.135-145
    • /
    • 2005
  • The purpose of this study is to reveal the component characteristics and the channels of distribution for forest products as a fuel that were consumed in Kyeongseong city (Seoul) in 1929, in the middle of the colonial period. The summary of the results are as follows; (1) though the average consumption of forest products consumed as a fuel per household in Kyeongseong city was slightly less than one-third as much forest products as fuel consumed in other counties of Kyeongki province, but due to the high heat capacity, the amount of fuelwood and charcoal consumption was much higher than leaf and grass consumption; (2) the largest supply areas of forest products for fuel were the riverside of Kangwon province and Kyeonggi province in which the waterways were available. They supplied 42.6% of total consumption, and the other supply areas were the northern part of Kyeonggi province, etc. (29.5%) where railroads were handy, and the suburbs of Kyeongseong City (27.9%) by roads; (3) the transportation areas using the Han River were divided into two parts of Ttook island (43.0%) and former Yongsan and Mapo (45.6%), but the volume of transportation by railroad was centralized in Kyeongseong Station, which accounted for 72.2% of total volume of transportation by rail; (4) the most of the forest products consumed for fuel in Kyeongseoung city were sold in temporary fuelwood markets, rather than permanent and regular markets.

Effect of Electrolytic Material Feeding on Blood and Carcass Traits of Broiler under Intense Heat Condition in Summer (폭염 시 육계 출하 전 전해질 급여가 닭고기 도체 및 혈액에 미치는 영향)

  • Chae, Hyun-Seok;Choi, Hee-Chul;Na, Jae-Cheon;Kim, Min-Ji;Kang, Hwan-Ku;Kim, Dong-Wook;Kim, Ji-Hyeok;Jo, Soo-Hyun;Lee, Chong-Eon;Kim, Nam-Young;Choi, Yang-Ho;Park, Byong-Sung
    • Korean Journal of Poultry Science
    • /
    • v.39 no.3
    • /
    • pp.183-193
    • /
    • 2012
  • This study was conducted to investigate the effect of feeding the electrolytic materials on blood and carcass traits of broiler during transportation exposed under intense heat condition in summer. The broilers were selected on the day when the outside temperature was about $32^{\circ}C$ to provide heat stressed environment. Broilers reared for 33 d were selected and fed with the electrolytic materials ($NaHCO_3$, NaCl, KCl) for 2 days. Treatments were as follows; feeding the underground water for control, $NaHCO_3$ (1.0%) + NaCl (0.5%) for treament 1, KCl (0.5%) + NaCl (0.5%) for treatment 2, KCl (1.0%) + NaCl (0.5%) treatment 3, KCl (0.5%) + $NaHCO_3$ (1.0%) + NaCl (0.5%) for treatment 4 and KCl (1.0%) + $NaHCO_3$ (1.0%) + NaCl (0.5%) for treament 5. pH of chicken meat increased for treatments group of electrolytic material, especially, that of treatment 3 was highest when compared to the other treatments. The frequency rate (%) of $1^+$ quality grade were 33.3, 60.0 and 83.3% at control, treatment 3, 4 and treatment 5, respectively. Occurrence rates of PSE were 50% for control and 13.3% for treatment 5. Corticosterone increased at the post-harvest period compared to the pre-harvest period of broiler and have small disparity between pre-and post-harvest only except treatment 3 when compared to control. $pCO_2$ partial pressure of blood at the pre-harvest period was low in all treatments by heat stress, the disparity value of control was high for control, and those of treatment 4 and 5 were low compared to other treatments.

Microbiological Hazard Analysis for HACCP System Application to Non Heat-Frozen Carrot Juice (비가열냉동 당근주스의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Lee, Ung-Soo;Kwon, Sang-Chul
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.79-84
    • /
    • 2014
  • This study has been performed for about 270 days at analyzing biologically hazardous factors in order to develop HACCP system for the non heat-frozen carrot juice. A process chart was prepared by manufacturing process of raw agricultural products of non heat-frozen carrot juice, which was contained water and packing material, storage, washing, cutting, extraction of the juice, internal packing, metal detection, external packing, storage and consignment (delivery). As a result of measuring Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, Enterohemorrhagic E. coli before and after washing raw carrot, Standard plate count was $4.7{\times}10^4CFU/g$ before washing but it was $1.2{\times}10^2CFU/g$ detected after washing. As a result of testing airborne bacteria (Standard plate count, Coliform group, Yeast and Fungal) depending on each workplace, number of microorganism of in packaging room, shower room and juice extraction room was detected to be 10 CFU/Plate, 60 CFU/Plate, 20 CFU/Plate, respectively. As a result of testing palm condition of workers, as number of Standard plate count, Coliform group and Staphylococcus aureus was represented to be high as $6{\times}10^4CFU/cm^2$, $0CFU/cm^2$ and $0CFU/cm^2$, respectively, an education and training for individual sanitation control was considered to be required. As a result of inspecting surface pollution level of manufacturing facility and devices, Coliform group was not detected in all the specimen but Standard plate count was most dominantly detected in scouring kier, scouring kier tray, cooling tank, grinding extractor, storage tank and packaging machine-nozzle as $8.00{\times}10CFU/cm^2$, $3.0{\times}10CFU/cm^2$, $4.3{\times}10^2CFU/cm^2$, $7.5{\times}10^2CFU/cm^2$, $6.0{\times}10CFU/cm^2$, $8.5{\times}10^2CFU/cm^2$ respectively. As a result of analyzing above hazardous factors, processing process of ultraviolet ray sterilizing where pathogenic bacteria may be prevented, reduced or removed is required to be controlled by CCP-B (Biological) and critical level (critical control point) was set at flow speed is 4L/min. Therefore, it is considered that thorough HACCP control plan including control criteria (point) of seasoning fluid processing process, countermeasures in case of its deviation, its verification method, education/training and record control would be required.

A Basic Study to Reveal the Relationships between Solar Thermal Radiation and Thermographic Images (태양 복사와 열화상이미지의 관계에 대한 기초 연구)

  • Kim, Jeongbae
    • Journal of Institute of Convergence Technology
    • /
    • v.10 no.1
    • /
    • pp.13-17
    • /
    • 2020
  • Among the factors that must be taken into account when using thermal imaging cameras that are expanding their application to various fields, a basic study was conducted focusing on temperature on the effect of solar radiation on the photographed thermal image. Through all experiments, in order to use an image taken with a thermal imaging camera for an object installed or located outdoors, a separate temperature correction according to the size of solar radiation or a separate device to block the effect of solar radiation must be additionally installed. Since the temperature of the same object may vary in the thermal image taken indoors or outdoors, it is necessary to calibrate it through comparison with other temperatures as a reference point. In the case of measuring the temperature of a glossy surface such as metal indoors with a thermal imaging camera, it was confirmed that an environment that can remove the light reflection effect by the glossy surface must be constructed and photographed.

Effect of Steam Curing on Concrete Piles with Silica Fume

  • Yazdani, N.;F. Asce, M. Filsaime;Manzur, T.
    • International Journal of Concrete Structures and Materials
    • /
    • v.4 no.1
    • /
    • pp.9-15
    • /
    • 2010
  • Silica fume is a common addition to high performance concrete mix designs. The use of silica fume in concrete leads to increased water demand. For this reason, Florida Department of Transportation (FDOT) allows only a 72-hour continuous moist cure process for concrete containing silica fume. Accelerated curing has been shown to be effective in producing high-performance characteristics at early ages in silica-fume concrete. However, the heat greatly increases the moisture loss from exposed surfaces, which may cause shrinkage problems. An experimental study was undertaken to determine the feasibility of steam curing of FDOT concrete with silica fume in order to reduce precast turnaround time. Various steam curing durations were utilized with full-scale precast prestressed pile specimens. The concrete compressive strength and shrinkage were determined for various durations of steam curing. Results indicate that steam cured silica fume concrete met all FDOT requirements for the 12, 18 and 24 hours of curing periods. No shrinkage cracking was observed in any samples up to one year age. It was recommended that FDOT allow the 12 hour steam curing for concrete with silica fume.

A Numerical Model for the Freeze-Thaw Damages in Concrete Structures

  • Cho Tae-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.857-868
    • /
    • 2005
  • This paper deals with the accumulated damage in concrete structures due to the cyclic freeze-thaw as an environmental load. The cyclic ice body nucleation and growth processes in porous systems are affected by the thermo-physical and mass transport properties, and gradients of temperature and chemical potentials. Furthermore, the diffusivity of deicing chemicals shows significantly higher value under cyclic freeze-thaw conditions. Consequently, the disintegration of concrete structures is aggravated at marine environments, higher altitudes, and northern areas. However, the properties of cyclic freeze-thaw with crack growth and diffusion of chloride ion effects are hard to be identified in tests, and there has been no analytic model for the combined degradations. The main objective is to determine the driving force and evaluate the reduced strength and stiffness by freeze-thaw. For the development of computational model of those coupled deterioration, micro-pore structure characterization, pore pressure based on the thermodynamic equilibrium, time and temperature dependent super-cooling with or without deicing salts, nonlinear-fracture constitutive relation for the evaluation of internal damage, and the effect of entrained air pores (EA) has been modeled numerically. As a result, the amount of ice volume with temperature dependent surface tensions, freezing pressure and resulting deformations, and cycle and temperature dependent pore volume has been calculated and compared with available test results. The developed computational program can be combined with DuCOM, which can calculate the early aged strength, heat of hydration, micro-pore volume, shrinkage, transportation of free water in concrete. Therefore, the developed model can be applied to evaluate those various practical degradation cases as well.

A Study on Frequency Dependence on Dielectric Properties of Silicone Rubber Sheets (실리콘 고무 시트의 유전특성에 미치는 주파수 의존성에 관한 연구)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.5
    • /
    • pp.405-410
    • /
    • 2020
  • In this study, the following results were obtained by analysis of electric properties with FT-IR, DSC, XRD, and SEM, in the range of temperature 30~160℃ and frequency 0.1~200 kHz, when filling agent (0~100 phr) and silicone oil (0~12 phr) were added to raw silicone rubber. In the case of 100 phr mixed samples, the relative dielectric constant εr gradually decreased from 4.3 to 3.96 as frequency increased, and the dielectric loss tan δ decreased to 0.01 at 300 Hz, then increased to 0.022 at 30 kHz, then decreased to 200 kHz. The FT-IR analysis identified the same binding structure according to the chemical composition of added silica (SiO2). Through DSC analysis, we could determine the change of heat quantity and the glass transition temperature of each specimen. In the XRD analysis, it was found that the images SiO2, TiO2, and Fe2O3 appeared for specimens with 0%, 50% and 100% filling agent. Finally, the SEM analysis confirmed that particles of 0.5 to 1.5 ㎛ size with silica (SiO2) mixing were dispersed evenly.

A Study on the Implementation Issues for Demand-side Management of Energy Suppliers (에너지공급자 수요관리 개선방안 연구)

  • Kim, Hyeong-Jung;Son, Hag-Sig
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1566-1574
    • /
    • 2010
  • This paper presents an in-depth review for current status for demand-side management (DSM) investment of energy supplier and an useful prospect on the introduction of Energy Efficiency Resource Standards (EERS). According to the Article 9 of Rational Energy Utilization Act, Energy suppliers-Korea Electric Power Corporation (KEPCO), Korea Gas Corporation (KOGAS) and Korea District Heat Corporation (KDHC) prescribed by Presidential Decree-must establish and implement annual demand-side management investment plan to improve energy efficiency in production, transformation, transportation, storage and usage of corresponding energy and to reduce demand and green house gas emissions. In this paper, we examine the DSM programs of energy suppliers and the results of DSM investment in 2009, then we propose a reasonable solution for the development of DSM investment. Furthermore, in order to compare our situation, the case studies were conducted on EERS issues in England, Italy, France and U.S, such as establishing the energy saving target, selecting the target energy supplier, and penalty and incentive mechanisms. Throughout the case studies, this paper suggests the directions to the DSM investment planning of energy suppliers and the major issues to prepare EERS in Korea.