• Title/Summary/Keyword: Heat exchange element

검색결과 25건 처리시간 0.021초

황토지로 제작된 전열교환소자의 전열특성 및 항균특성에 관한 연구 (Heat Transfer and Sterilization Characteristics of an ERV Element Made of Hwang-to Paper)

  • 조민철;오세기;안영철
    • 동력기계공학회지
    • /
    • 제21권1호
    • /
    • pp.50-56
    • /
    • 2017
  • To increase the enthalpy exchange efficiency of ERV elements, the moisture exchange character must be improved. The moisture exchange efficiency depends on material characteristics. The material used for ERV is Hwang-to paper based on Han-ji which is Korean traditional paper. The paper has excellent performance in moisture exchange and heat transfer compared with polymer and other papers. To have an anti bacteria performance and to improve moisture exchange performance of Han-ji, Hwang-to is added to the Han-ji. The enthalpy exchange efficiency of the Hwang-to paper shows 5% greater than that of the conventional paper. In case of Escherichia Coli, the reduction rate of bacteria is 96.6% and in case of Pseudomonas, the reduction rate of bacteria is 97.5%. The ERV element made of Hwang-to paper has a great possibility as an ERV element.

지중 열교환 시스템을 위한 열-수리 파이프 요소의 개발 (Development of Thermal-Hydro Pipe Element for Ground Heat Exchange System)

  • 신호성;이승래
    • 한국지반공학회논문집
    • /
    • 제29권8호
    • /
    • pp.65-73
    • /
    • 2013
  • 지중 열교환 시스템은 지속적인 에너지 효율의 개선으로 공간 냉난방을 위한 친환경적 에너지 기술로 주목받고 있다. 지중에 매설된 파이프는 내부 유체 순환을 통하여 인접한 지반과 열적 상호작용으로부터 직접적인 열에너지 교환을 수행한다. 하지만, 파이프의 수치모델링에서 열-수리가 연관된 난류해석과 파이프의 긴 세장비에 의한 메쉬사이즈의 부적합성은 열교환 시스템의 적절한 수치해석을 어렵게 하고 있다. 본 논문에서는 파이프 내부 유체흐름에 대한 에너지 보존의 법칙을 적용하여 지배방정식을 유도하였으며, Galerkin수식화와 시간적분을 통하여 열-수리 연동일차원 파이프 요소를 개발하였다. 그리고 제안된 파이프 요소를 기 개발된 다공질 재료를 위한 열-수리-역학(Thermo-Hydro-Mechanical) 해석을 위한 유한요소 프로그램과 결합하였다. 개발된 요소를 이용한 수치해석 결과는 열응답 시험(Thermal Response Test) 결과로부터 주위지반의 유효 열전도도를 평가하기 위하여 사용하는 선형 열원 모델이 인접 파이프간의 열적상호작용과 파이프의 단부효과에 의하여 지반의 열전도도를 과다 평가하는 것으로 보여주었다. 따라서 열응답 시험 해석 결과에 대한 역해석을 적용하여 최적의 수렴성을 보여주는 변환행렬을 제시하였다.

통신 함체 냉각용 알루미늄과 플라스틱 열교환 소자의 성능 비교 (Aluminum and Plastic Heat Exchange Element : A Performance Comparison for Cooling of Telecommunication Cabinet)

  • 김내현
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.279-288
    • /
    • 2017
  • Heat generation rate in a telecommunication cabinet increases due to the continued usage of mobile devices. Insufficient removal of heat intensifies the cabinet temperature, resulting in the malfunction of electronic devices. In this study, we assessed both aluminum and plastic heat exchangers used for cooling of the telecommunication cabinet, and compared the results against theoretical predictions. The aluminum heat exchanger was composed of counter flow parallel channels of 4.5 mm pitch, and the plastic heat exchangers were composed of cross flow triangular channels of 2.0 mm pitch. Samples were made by installing two plastic heat exchangers in both series and parallel. Results showed that the heat transfer rate was highest for the series cross flow heat exchanger, and was least for the aluminum heat exchanger. The temperature efficiency of the series cross flow heat exchanger was 59% greater than that of the aluminum heat exchanger, and was 4.3% greater than that of the parallel cross flow heat exchanger. In contrast, the pressure drop of the parallel cross flow heat exchanger was significantly lower than other samples. The heat exchange efficiency was also the largest for the parallel cross flow heat exchanger. The theoretical analysis predicted the temperature efficiency to be within 3.3%, and the pressure drop within 6.1%.

딤플형 EGR 냉각기의 설계 및 성능평가 (Design and Performance Evaluation of Dimpled EGR Cooler)

  • 서영호;이현민;허성찬;구태완;송우진;강범수;김정
    • 대한기계학회논문집A
    • /
    • 제34권3호
    • /
    • pp.291-298
    • /
    • 2010
  • 본 논문은 자동차 디젤엔진의 EGR 시스템에 사용되는 EGR 냉각기의 열교환 효율에 관한 것으로 배기가스의 냉각수 사이의 열교환을 촉진시키기 위한 방법으로 딤플형 EGR 냉각기를 설계 및 그 성능을 평가하였다. 개발초기 단계에서 딤플형 EGR 냉각기의 성능을 평가하기 위하여 기존 스파이럴 타입의 EGR 냉각기와 딤플형 EGR 냉각기의 전열면적을 비교하였으며, 균질화 기법을 이용한 유한요소해석을 통하여 딤플형 EGR 냉각기의 구조 건전성을 평가하였다. 또한, 딤플형 열교환 튜브의 생산공정-딤플성형, edge bending, center v-notch bending, 압착, 플라즈마 용접-을 체계화하였다. 최종적으로 본 연구를 통하여 딤플형 EGR 냉각기를 개발하였으며, 그 성능을 검증하였다.

PHC 에너지 파일의 열교환율 예측에 관한 연구 (Prediction of Heat Exchange Rate in PHC Energy Piles)

  • 윤석;이승래;박현구;박도원;고규현
    • 한국지반공학회논문집
    • /
    • 제29권9호
    • /
    • pp.31-41
    • /
    • 2013
  • 최근 들어 경제적인 지열에너지 활용을 위하여 에너지 파일의 적용이 확대되고 있다. 특히 더 높은 열 교환 효율을 확보하고자 에너지 파일의 경우 보다 높은 열효율을 얻기 위해 통상적인 U자형 지중 열교환기가 아닌 코일형 지중열교환기를 매입하는 경우가 늘어나고 있다. 본 논문에서는 PHC 에너지 파일에 의한 지중 열 전달 거동에 대한 수치해석 및 실험적 연구를 수행하였다. 화강풍화토로 이루어진 현장에 PHC 에너지 파일을 설치하고 W자형과 코일형 지중 열교환기를 설치한 후 이에 대한 현장 열성능 실험을 수행하였다. 또한 3차원 유한요소해석을 수행하여 지중온도 및 지중 열교환기 내 순환수 온도 변화를 예측하였고 이를 실험값과 비교하였다. 냉방 부분 가동 조건 하에서 코일형 열교환기 이용시 W자형을 이용했을 때보다 10~15% 열교환율이 상승되는 것을 알 수 있었다.

건축외부공간에 있어서 인체의 일사열부하(日射熱負荷) 및 열적(熱的) 쾌적성(快適性)에 관한 실험적 연구 (Human Solar Heat Load and Thermal Comfort in an Outdoor Environment)

  • 정창원;윤인
    • 한국산업융합학회 논문집
    • /
    • 제1권2호
    • /
    • pp.65-74
    • /
    • 1998
  • The purpose of this paper is to investigate the mount of relief of human solar heat load and thermal comfort in outdoor environment in summer, Six different types of sites, T garden and its neighboring area in Japan, were selected as the experiment sites. The experiments were conducted from 22 to 29 August, 1994 to find the relationship between climatic conditions and human responses, Climatic conditions, subjects's thermal sensation and skin temperature were measured. Radiant heat exchange on the human body was estimated on the basis of the measured air and surface temperature and solar radiation. Thermal index Operative Temperature and New Effective Temperature was modified with the effect of the radiant heat exchange. Human thermal comfort and skin temperature is affected by the solar radiation and the sky factor in an outdoor environment. The effect of tree shade was verified on thermal comfort, The mount of relief of human solar heat load is relation to the existence of shade a solar radiation and the sky factor. The urban garden is one of the effective design element in an urban environmental planning.

  • PDF

딤플 튜브형 EGR Cooler 구조건전성 및 열효율 평가 (Evaluation of Structural Integrity and Heat Exchange Efficiency for Dimpled Tube Type EGR Cooler)

  • 서영호;이현민;박중원;구태완;김정;강범수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.554-559
    • /
    • 2008
  • Most of vehicle manufacturers have applied exhaust gas recirculation (EGR) system to the development of diesel engines in order to obtain the high thermal efficiency without $NO_X$ and Particulate Matter (PM) emitted from the engine. EGR system, which reflow a cooled exhaust gas from vehicles burning diesel as fuel to a combustion chamber of engine, has been used to solve this problem. In order to confirm the safety of the EGR system, finite element analysis was carried out. The safety of EGR system against temperature variation in the shell and tubes was evaluated through the thermal and structural analysis, and the modal analysis using ANSYS was also performed. Finally, the performance of EGR system was verified through the experiment and numerical simulation using effectiveness-NTU method. Program for the estimation of the heat exchange efficiency of the EGR system with regard to the dimpled tube shape was developed.

  • PDF

냉난방 가동 모사에 따른 콘크리트 에너지파일의 열응력 해석에 대한 연구 (Study on Thermal Stress Occurred in Concrete Energy Pile During Heating and Cooling Buildings)

  • 성치훈;박상우;김병연;정경식;최항석
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권2호
    • /
    • pp.12-18
    • /
    • 2015
  • The energy pile, used for both structural foundations and heat exchangers, brings about heat exchange with the ground formation by circulating a working fluid for heating and cooling buildings. As heat exchange occurs in the energy pile, thermal stress and strain is generated in the pile body and surrounding ground formation. In order to investigate the thermo-mechanical behavior of an energy pile, a comprehensive experimental program was conducted, monitoring the thermal stress of a cast-in place energy pile equipped with five pairs of U-type heat exchanger pipes. The heating and cooling simulation both continued for 30 days. The thermal strain in the longitudinal direction of the energy pile was monitored for a 15 operation days and another 15 days monitoring followed, without the application of heat exchange. In addition, a finite element model was developed to simulate the thermo-mechanical behavior of the energy pile. A non-linear contact model was adopted to interpret the interaction at the pile-soil interface, and thermal-induced structure mechanics was considered to handle the thermo-mechanical coupled multi-field problem.

열 교환 소자 형상의 CFD 시뮬레이션을 통한 판형 전열 교환기 성능평가 (A Performance Evaluation of Plate Type Enthalpy Exchanger through CFD Analysis of Elements)

  • 강인성;안태경;박진철
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.1-6
    • /
    • 2017
  • In order to better save energy, many buildings have been constructed with high levels of insulation and airtightness in recent years. Additionally, having high quality indoor air has become more relevant, necessitating a ventilating system. This study is aimed at evaluating the performance of a humidity exchanger through computational fluid dynamics (CFD) analysis of elements for the purpose of providing comfortable indoor air and reduced energy consumption. The simulation was conducted with three different shapes (triangle, rectangular, and curve) of heat exchanger elements, in order to find the most effective element. A follow-up simulation then proved the efficiency of the chosen humidity exchanger, which was selected by analyzing the results of the preceding simulation, comparing study data with measurement data from the Korea Testing Laboratory (KTL). The resulting analysis revealed that the rectangular element showed the lowest level of efficiency in both heating and cooling, while the curved element showed the highest level of efficiency in both heating and cooling.

매스콘크리트의 파이프 쿨링 효과 (A Study on the Effect of Pipe Cooling in Mass-Concrete)

  • 윤승권;김은경;김래현;신치범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.329-333
    • /
    • 1995
  • The usual methods for the temperature control of mass-concrete structures include the use of low-heat cement, pre-cooling, or pipe-cooling. In order to control the heat of hydration of mass-concrete structures such as massive pier or anchor block, and mat foundation, the pipe cooling method is widely acceptable for pratical use. In this paper, method of analysis using the Finite Element Method was applied to analyze the heat exchange on the field of three dimensional thermal conduction. The result of analysis Well agreed with experimentally measurement data by "KUMATANI". The method of this analysis will be used widely to control the heat of hydration by the pipe cooling in mass-concrete.-concrete.

  • PDF