• Title/Summary/Keyword: Heat balance equation

Search Result 102, Processing Time 0.023 seconds

A Numerical Study of Heat and Mass Transfer Phenomena for Thermal Protection Material (열보호재료의 열 및 물질전달 현상에 관한 수치해석적 연구)

  • Kim, Jung-Hoon;Kwon, Chang-Oh;Seo, Jeong-Il;Bai, Cheol-Ho;Song, Dong-Joo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1201-1212
    • /
    • 1999
  • A numerical analysis is performed to predict the thermal response and ablation rate for charring or non-charring material which is designed to be used as thermal protection system (TPS). The numerical program composed of in-depth energy balance equation and the aerotherm chemical equilibrium (ACE) program. The ACE program calculates various thermochemical state from ablation products. The developed numerical program is verified by comparing the reported results from literature. The sensitivity tests for input parameters are performed. The thermal behavior of ablating material is mainly affected by density of ablating material, convective heat transfer coefficient and recovery enthalpy of flow field.

A Study on the Influence Affect of Thermal Sensation in Korean and Japanes to Sit Directly on a Heated Floor (바닥난방시 바닥 접촉면에 의한 한국인과 일본인의 온열감 반응에 대한 비교 연구)

  • Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.1
    • /
    • pp.81-89
    • /
    • 2002
  • The objective of this paper is to clarify the combined effect of heat conduction, air temperature and thermal radiation on the person seated on the floor under operation of floor heating system. Experiments were conducted for summer seasons under 8 kinds of condition: combinations of air temperature $20^{\circ}C$, $22.5^{\circ}C$ and floor temperature $20^{\circ}C$, $22.5^{\circ}C$, $30^{\circ}C$, $35^{\circ}C$ and $40^{\circ}C$ under still air. Japanese and Koreans were adopted as subjects. To evaluate the effect of conduction operative temperature modified by heat conduction was derived from the human heat balance equation. New weighting coefficients were estimated from the modified operative temperature and modified mean skin temperature. As for thermal sensation the modified operative temperature more significantly correlated to that sensation each heat transfer processes. As the floor temperature is higher, the human conduction heat gain from floor increase and the dry heat from the human body decrease.

  • PDF

TOKAMAK REACTOR SYSTEM ANALYSIS CODE FOR THE CONCEPTUAL DEVELOPMENT OF DEMO REACTOR

  • Hong, Bong-Guen;Lee, Dong-Won;In, Sang-Ryul
    • Nuclear Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.87-92
    • /
    • 2008
  • Tokamak reactor system analysis code was developed at KAERI (Korea Atomic Energy Research Institute) and is used here for the conceptual development of a DEMO reactor. In the system analysis code, prospects of the development of plasma physics and the relevant technology are included in a simple mathematical model, i.e., the overall plant power balance equation and the plasma power balance equation. This system analysis code provides satisfactory results for developing the concept of a DEMO reactor and for identifying the necessary R&D areas, both in the physics and technology areas for the realization of the concept. With this system analysis code, the performance of a DEMO reactor with a limited extension of the plasma physics and technology adopted in the ITER design. The main requirements for the DEMO reactor were selected as: 1) demonstrate tritium self-sufficiency, 2) generate net electricity, and 3) achieve a steady-state operation. It was shown that to access an operational region for higher performance, the main restrictions are presented by the divertor heat load and the steady-state operation requirements.

Unsteady Analysis of the Conduction-Dominated Three-Dimensional Close-Contact Melting (열전도가 주도적인 삼차원 접촉융해에 대한 비정상 해석)

  • Yoo, Hoseon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.8
    • /
    • pp.945-956
    • /
    • 1999
  • This work reports a set of approximate analytical solutions describing the initial transient process of close-contact melting between a rectangular parallelepiped solid and a flat plate on which either constant temperature or constant heat flux is imposed. Not only relative motion of the solid block tangential to the heating plate, but also the density difference between the solid and liquid phase is incorporated in the model. The thin film approximation reduces the force balance between the solid weight and liquid pressure, and the energy balance at the melting front into a simultaneous ordinary differential equation system. The normalized model equations admit compactly expressed analytical solutions which include the already approved two-dimensional solutions as a subset. In particular, the normalized liquid film thickness is independent of all pertinent parameters, thereby facilitating to define the transition period of close-contact melting. A unique behavior of the solid descending velocity due to the density difference is also resolved by the present solution. A new geometric function which alone represents the three-dimensional effect is introduced, and its properties are clarified. One of the representative results is that heat transfer is at least enhanced at the expense of the increase in friction as the cross-sectional shape deviates from the square under the same contact area.

A computer simulation of transport phenomena in a roller kiln (로울러 킬른 내의 이동현상에 관한 전산모사)

  • 이성철;김병수
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.2
    • /
    • pp.251-259
    • /
    • 1999
  • A computer simulation was conducted for heat and momentum transfer in a roller kiln. Time-averaged Navier-Stokes equation conjugated with energy balance equation was numerically solved to predict the temperature distribution and fluid flow field in the roller kiln. A computer simulation was performed for a roller kiln for three cases. Firstly, when there are no ceramic materials in the roller kiln, the effect of natural convection was studied on the temperature distribution and fluid flow field. From the result, it was observed that air takes the heat of wall away from the roller kiln by natural convection and the heat was not transferred effectively. Secondly, with ceramic materials temperature difference of ceramic material from the borrom to the top of a ceramic material was about 255K in 5th zone and this is because the heat is transferred from the surface of a ceramic material to flowing air with relatively low temperature. Finally, we considered effect of radiation heat transfer. Temperature difference of ceramic material in 5th zone was about 300 K, due to radiation heat transfer on the ceramic material surfaces.

  • PDF

A Study on the Evaluation Methods of Indoor Thermal Comfort Index in Building (실내(室內) 온열환경지표(溫熱環境指標)의 평가방법에 관한 연구)

  • Jeong, Chang-Won;Horikoshi, Tetsumi;Yoon, In;Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.2
    • /
    • pp.11-21
    • /
    • 1999
  • This objective of this paper is to investigate the evaluation and indiction of human thermal comfort in building environment. The issue of defining the boundaries of acceptable thermal comfort conditions in buildings and urban may have significant implication for building design and also may have urban design by climate considerations. And then it is to apply the thermal comfort condition to environmental design by using passive methods in Korea. Since 1920. architects have conducted studies to measure thermal comfort in houses under hot and humid conditions, while industrial hygienists have studied the effects of temperature and humidity on the performance of factory workers. Thermal comfort can be influenced by many variables. This paper conducted to review the previous researches and the human heat balance equation, and to analyse in order to reveal the meaning and usage of the thermal comfort index in two traditional essays, Fanger's PMV and Gagge's ET* Their comfort indexes compared with each other. They were based on human heat balance equation and psychological and physiological responses in the laboratory tests. The researchers and the architectural engineers using thermal comfort index shall be careful in decided the use of indexes and be necessary to recognize the value concept of the design criteria for thermal comfort. Therefore, The opinion of the authors is that different comfort standards have to apply for each building and urban with different climatic conditions.

  • PDF

A GN-based modified model for size-dependent coupled thermoelasticity analysis in nano scale, considering nonlocality in heat conduction and elasticity: An analytical solution for a nano beam with energy dissipation

  • Hosseini, Seyed Mahmoud
    • Structural Engineering and Mechanics
    • /
    • v.73 no.3
    • /
    • pp.287-302
    • /
    • 2020
  • This investigation deals with a size-dependent coupled thermoelasticity analysis based on Green-Naghdi (GN) theory in nano scale using a new modified nonlocal model of heat conduction, which is based on the GN theory and nonlocal Eringen theory of elasticity. In the analysis based on the proposed model, the nonlocality is taken into account in both heat conduction and elasticity. The governing equations including the equations of motion and the energy balance equation are derived using the proposed model in a nano beam resonator. An analytical solution is proposed for the problem using the Laplace transform technique and Talbot technique for inversion to time domain. It is assumed that the nano beam is subjected to sinusoidal thermal shock loading, which is applied on the one of beam ends. The transient behaviors of fields' quantities such as lateral deflection and temperature are studied in detail. Also, the effects of small scale parameter on the dynamic behaviors of lateral deflection and temperature are obtained and assessed for the problem. The proposed GN-based model, analytical solution and data are verified and also compared with reported data obtained from GN coupled thermoelasticity analysis without considering the nonlocality in heat conduction in a nano beam.

A Simple Condensation Model on the Vapor Jets in Subcooled Water (과냉각수로 방출되는 증기제트의 응축모델)

  • Kim, Hwan-Yeol;Ha, Kwang-Soon;Bae, Yoon-Yeong;Park, Jong-Kyun;Choi, Sang-Min
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.240-245
    • /
    • 2001
  • Phenomena of direct contact condensation (DCC) heat transfer between steam and water are characterized by the transport of heat and mass through a moving steam/water interface. Application of the phenomena of DCC heat transfer to the engineering industries provides some advantageous features in the viewpoint of enhanced heat transfer. This study proposes a simple condensation model on the steam jets discharging into subcooled water from a single horizontal pipe for the prediction of the steam jet shapes. The analysis model was derived from the mass, momentum and energy equations as well as a thermal balance equation with condensing characteristics at the steam/water interface for the axi-symmetric coordinates. The extremely large heat transfer rate at the steam/water interface was reflected in the effective thermal conductivity estimated from the previous experimental results. The analysis results were compared with the experimental ones. The analysis model predicted that the steam jet shape (i. e. radius and length) was increasing as the steam mass flux and the pool temperature were increasing, which was similar in trend to that observed in the experiment.

  • PDF

Estimation Method of Evapotranspiration over Goheung bay Wetland (고흥만 습지에서 증발산량의 산출 방법)

  • KWON, Byung Hyuk;KIM, Dong Su;KIM, Geun Hoi;KANG, Dong Hwan
    • Journal of Wetlands Research
    • /
    • v.10 no.1
    • /
    • pp.21-30
    • /
    • 2008
  • Evapotranspiration is an important factor in the energy interaction process between the surface and the air. Over a vegetable canopy, evapotranspiration was investigated by measuring the sensible heat flux, the soil heat flux and the net radiation flux. Evapotranspiration based on routine AWS data is in good agreement with that estimated from the energy balance equation except for weak wind shear less than $1s^{-1}$ and a cloudy period. Soil heat flux can be approximately to 10% of net radiation flux at the lower layer. When the slope of the saturation vapor pressure versus temperature curve ($de_s/dT$) is approximated to 1.5, the evapotranspiration can be described in function of the net radiation energy flux over Goheung bay wetland covered with the vegetable canopy, reeds.

  • PDF

Basic Study on the Heat Transfer During Rapid Freezing of Syobean Seed by Liquid Nitrogen

  • Kawano, Toshio;Nakano, Kohei;Murata, Satoshi
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.443-452
    • /
    • 1993
  • Direct freezing tests of soybean seed by liquid nitrogen were carried out at various moisture contents and the following important conclusions were drawn from the results of temperature measurements of soybean seed and photographs of bubbles generated on its surface : 1) Assuming that the temperature gradient in a soybean seed is negligible because of its small seed size and the freezing ratio is followed the Heiss's formula, and a differential equation based on the heat energy balance was introduced . The equation was easily solved by the Runge-Kutta-Gill method and the predicted values of the temperature were in good agreement with the observed data. 2) The photographs of bubble generation during freezing showed the boiling mode was nucleate, and then the most suitable formula on the nucleate boiling heat transfer was introduced from many formulate proposed up to now by fitting the calculated values based on the formula to the observed data. The formula used for the predict on of the seed temperature was as follows: $\frac{{\partial}T_s}{\partial\theta}\;=\;-\frac{{\alpha}(T_s\;-\;T_L)^{3.3}}{W(C_s\;-\;\frac{{\delta}m(CT_s\;+\;{\sigma})}{T_s^2})}$ where C = difference of the specific heat between pure ice and water m=moisture content of soybean seed $T_s$ = seed temperature $T_L$ = Temperature of liquid nitrogen W = mass of soybean seed $\alpha$ = proportional constant $\delta$ = constant depends on variety or the type of seed $\theta$ = time $\sigma$ = latent heat of melting of pure ice This study will give important information in the hydro-freezing technique by liquid nitrogen, available as a new technique of processing agricultural products in the near future.

  • PDF