• Title/Summary/Keyword: Heat Insulation

Search Result 884, Processing Time 0.025 seconds

Study on the Thermal and Mechanical Properties of Elastic Epoxies (탄성에폭시의 열적.기계적 특성에 관한 연구)

  • Min, J.Y.;Lee, K.W.;Lee, K.Y.;Park, D.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.248-251
    • /
    • 2003
  • In this paper, it was experimented about thermal and mechanical insulation properties of a elastic epoxy specimen. We made elastic epoxy specimen adding a ratio of 0[phr], 20[phr], 35[phr] and 53[phr] with modifier to existing epoxy. Each specimen was absorbed by 25h, 196h, 361h 484h with water. In water-absorption state, it was experimented a change of heat flows by temperature of elastic epoxy and changes of thermal expansion coefficient. Also, a hardness-change of each specimen was experimented by change of water-absorption time. In this experiment DSC (Differential Scanning Calorimetry) and TMA (Thermomechanical Analysis) were used. A temperature range of DSC was changed from -0[$^{\circ}C$] to 200[$^{\circ}C$], TMA was changed from -0[$^{\circ}C$] to 350[$^{\circ}C$]. In addition, we investigated structural analysis of water absorbed specimen using SEM (Scanning electron microscope).

  • PDF

Deformation and Life Evaluation of PC Plastic Materials Subjected to Repeated Impact Loads (반복적인 충격하중을 받은 PC 플라스틱 재료의 변형 및 수명 평가)

  • Lee, Jin-Kyung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_2
    • /
    • pp.611-616
    • /
    • 2020
  • Polycarbonate (PC) materials having electrical insulation properties, are thermoplastic material and are easily processed, have excellent strength and heat resistance characteristics, and also have transparent and hard characteristics. In this study, we tried to derive the ε-N curve of strain-life, which shows the relationship between the strain characteristics and the life of the material when repeated impact loads are applied to the PC plastic material. As the impact load increased to 3.0kg, 4.0kg, 5.0kg, and 6.0kg, the strain also increased linearly to 0.033, 0.041, 0.046, and 0.055. At 3.0kg of mass impact, the test piece broke with 12000 impact cycles, 8400 times at 3.5kg, 7400 times at 4.0kg, 6600 times at 4.5kg, 4700 times at 5.0kg, 3000 times at 5.5kg, and 1000 times at 6.0kg. The number of fractures exponentially decreased as the load gradually increased. Using these results, an ε-N curve for PC plastic was derived.

CHARACTERISTICS OF FIRE PROTECTIVE COATING THE TERNARY SOLUBLE SILICATE

  • Lee, Nae-Woo;Choi, Jae-Wook;Kim, Jeong-Hun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.120-129
    • /
    • 1997
  • The fire protective coating can reduce certain damages in case of fire, also conserve energy by thermal insulation and prevent corrosion and errosion in normal daily life by means of blocking thermal transfer, that were generally made of organic, inorganic and metallic materials as adiabatic coating. In case of inorganic material such as soluble silicate, it produces less toxic substances which are exposed to Ore, and have a plenty of raw material. Also inorganic thermal insulator is good in heat resistance. To develope such a excellent inorganic thermal insulator, the study of fire protective coating using the alkali silicate is necessary The principle of intumescence for alkali silicate is from rapid evolution of water in the coating material, the quantity of water in it is of course influenced on the degree of intumescence. The phenomenon of intumescence in ternary silicate is increased as the radius of ion is bigger, and this is caused by evolution of so many kinds of water. The individual degree of intumescence is ordered like this ; $K^+$ > $Na^+$ > $Li^+$ . The best protection effect is similarity found to intumescence of ternary silicate. The result of X-ray diffraction analysis indicates that $KHSi_2O_5$ is an important ingredient in K-silicate.

  • PDF

Dynamic analysis of ACTIVE MOUNT using viscoelastic-elastoplastic material model

  • Park, Taeyun;Jung, Wonuk
    • International Journal of Reliability and Applications
    • /
    • v.17 no.2
    • /
    • pp.137-147
    • /
    • 2016
  • The engine mount of a car subjected to a pre-load related to the weight of the engine, and acts to insulate the vibration coming from the engine by moving on large or small displacement depending on the driving condition of the car. The vibration insulation of the engine mount is an effect obtained by dissipating the mechanical energy into heat by the viscosity characteristic of the rubber and the microscopic behavior of the additive carbon black. Therefore, dynamic stiffness from the intrinsic properties of rubber filled with carbon black at the design stage is an important design consideration. In this paper, we introduced a hyper-elastic, visco-elastic and elasto-plastic model to predict the dynamic characteristics of rubber, and developed a fitting program to determine the material model parameters using MATLAB. The dynamic characteristics analysis of the rubber insulator of the ACTIVE MOUNT was carried out by using MSC.MARC nonlinear structural analysis software, which provides the dynamic characteristics material model. The analysis results were compared with the dynamic characteristics test results of the rubber insulator, which is one of the active mount components, and the analysis results were confirmed to be valid.

Flammability and Multi-objective Performance of Building Façades: Towards Optimum Design

  • Bonner, Matthew;Rein, Guillermo
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.363-374
    • /
    • 2018
  • The façade is an important, complex, and costly part of a building, performing multiple objectives of value to the occupants, like protecting from wind, rain, sunlight, heat, cold, and sound. But the frequency of façade fires in large buildings is alarming, and has multiplied by seven times worldwide over the last three decades, to a current rate of 4.8 fires per year. High-performing polymer based materials allow for a significant improvement across several objectives of a facade (e.g., thermal insulation, weight, and construction time) thereby increasing the quality of a building. However, all polymers are flammable to some degree. If this safety problem is to be tackled effectively, then it is essential to understand how different materials, and the façade as a whole, perform in the event of a fire. This paper discusses the drivers for flammability in facades, the interaction of facade materials, and current gaps in knowledge. In doing so, it aims to provide an introduction to the field of façade fires, and to show that because of the drive for thermal efficiency and sustainability, façade systems have become more complex over time, and they have also become more flammable. We discuss the importance of quantifying the flammability of different façade systems, but highlight that it is currently impossible to do so, which hinders research progress. We finish by putting forward an integral framework of design that uses multi-objective optimization to ensure that flammability is minimized while considering other objectives, such as maximizing thermal performance or minimizing weight.

Analysis of Thermal Characteristics of the Electrical Socket-Outlets by Overcurrent (과전류에 의한 전기콘센트의 열적특성 분석)

  • Kim, Doo Hyun;Kim, Sung Chul;Kim, Kyung Chun
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.8-14
    • /
    • 2019
  • Many electrical socket-outlet fire accidents take place not only in homes but in the offices each year. The causes are mostly faulty constructions, managerial problems and carelessness. Construction and managerial flaws can be resolved by regular or special inspections, but carelessness is not solvable through inspections. Such carelessness can be related to the consumption capacity of electrical socket-outlets presently, the rated current of electrical socket-outlets is based on 16A. However, even at 16A, the heat generated in the insulator of an electrical socket-outlet varies due to such factors as part damage and environmental conditions of use. To explore this situation, the study conducted an experiment to analyze thermal relationship by applying 10A, 20A, and 30A currents. To secure reliability, the study employed thermal analysis simulation and compared the thermal relationship in the same current value. The experimental and simulation values were found to be similar and therefore, diverse current values were replaced with the simulation. At 30A, the temperature was found to rise to at least $169.9^{\circ}C$ which had worked as a sufficient amount of energy to bring the insulation aging of insulator.

A Study on the Cold Reserving Performance of PET Bottle with Shrinkage Film

  • Hong, Dae Gi;Lyu, Min Young
    • Elastomers and Composites
    • /
    • v.54 no.2
    • /
    • pp.123-127
    • /
    • 2019
  • Shrink film is currently being used for plastic container lavels to avoid the use of glue. Polyethylene terephthalate (PET) bottle lavels also use shrink films in the same PET materials for easy recycling of PET bottles. An air layer is generated between the shrink film and PET bottle surface due to the bent shape of the bottle surface. This air layer can insulate external heat, as air has a relatively lower thermal conductivity. In this study, the insulation property of the air layer was examined by computer simulation. Two PET bottle models were used, one with and the other without an air layer between the PET bottle surface and lavel. The two bottle models were filled with cold liquid and exposed to room temperature for 6 h, and the temperatures of the contents were then compared. The results showed that the temperature of the contents in the bottle with the air layer was lower than that without the air layer by at least $2^{\circ}C$. This study suggests an effective lavel design of PET bottles while ensuring that the temperature of the bottle contents is maintained.

Surface observation of Ni(OH)2 nanosheets fabricated by electrodeposition method (전착법에 의해 제작된 Ni(OH)2 나노 시트의 표면 관찰 및 분석)

  • Kim, Dong Yeon;Son, Injoon;Choi, Mun-Hyun
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.3
    • /
    • pp.152-157
    • /
    • 2021
  • The pseudocapacitor has a high energy density characteristic because it accumulates charges through a paradic redox reaction. However, due to its strong insulation properties, metal hydroxides should be designed as structural systems optimized for charge transfer to support fast electron transport. Also, Nickel material is weak to heat and is easily deformed when used as a cathode material, so stability must be secured. In this study, nickel hydroxide was produced by electrodeposition to secure the stability of nickel. Electrodeposition is a synthetic method suitable for growing optimized nickel hydroxide because it allows fine control. Nickel hydroxide (Ni(OH)2) is a metal hydroxide used as a pseudocapacitor anode due to its high capacitance, electrical conductivity and resistance. Therefore, in order to determine how Ni(OH)2 nanosheets are formed and what are the optimization conditions, various measurement methods were used to focus on structural growth of nanosheets produced by electrodeposition.

Stability and normal zone propagation in YBCO tapes with Cu stabilizer depending on cooling conditions at 77 K

  • Kruglov, S.L.;Polyakov, A.V.;Shutova, D.I.;Topeshkin, D.A.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.14-19
    • /
    • 2020
  • Here we present the comparative experimental study of the stability of the superconducting state in 4 mm YBCO tapes with copper lamination against local heat disturbances at 77 K. The samples are either directly cooled by immersing a bare YBCO tape into a liquid nitrogen pool or operate in nearly-adiabatic conditions when the tape is covered by a 0.6 mm layer of Kapton insulation. Main quench characteristics, i.e. minimum quench energies (MQEs) and normal zone propagation (NZP) velocities for both samples are measured and compared. Minimum NZP currents are determined by a low ohmic resistor technique eligible for obtaining V - I curves with a negative differential resistance. The region of transport currents satisfying the stationary stability criterion is found for the different cooling conditions. Finally, we use the critical temperature margin as a universal scaling parameter to compare the MQEs obtained in this work for YBCO tapes at 77 K with those taken from literature for low-temperature superconductors in vacuum at 4.2 K, as well as for MgB2 wires cooled with a cryocooler down to 20 K.

Effects of freezing and thawing on retaining wall with changes in groundwater level

  • Kim, Garam;Kim, Incheol;Yun, Tae Sup;Lee, Junhwan
    • Geomechanics and Engineering
    • /
    • v.24 no.6
    • /
    • pp.531-543
    • /
    • 2021
  • Freezing and thawing of pore water within backfill can affect the stability of retaining wall as the phase change of pore water causes changes in the mechanical characteristics of backfill material. In this study, the effects of freezing and thawing on the mechanical performance of retaining wall with granular backfill were investigated for various temperature and groundwater level (GWL) conditions. The thermal and mechanical finite element analyses were performed by assigning the coefficient of lateral earth pressure according to phase change of soil for at-rest, active and passive stress states. For the at-rest condition, the mobilized lateral stress and overturning moment changed markedly during freezing and thawing. Active-state displacements for the thawed condition were larger than for the unfrozen condition whereas the effect of freezing and thawing was small for the passive condition. GWL affected significantly the lateral force and overturning moment (Mo) acting on the wall during freezing and thawing, indicating that the reduction of safety margin and wall collapse due to freezing and thawing can occur in sudden, unexpected patterns. The beneficial effect of an insulation layer between the retaining wall and the backfill in reducing the heat conduction from the wall face was also investigated and presented.