• 제목/요약/키워드: Heat Insulation

검색결과 887건 처리시간 0.032초

초고온 시스템용 SiCN 마이크로 구조물 제작 (Fabrication SiCN micro structures for extreme high temperature systems)

  • 판 투이 탁;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.216-216
    • /
    • 2009
  • This paper describes a novel processing technique for the fabrication of polymer-derived SiCN (silicone carbonitride) microstructures for extreme microelectromechanical system (MEMS) applications. A polydimethylsiloxane (PDMS) mold was formed on an SU-8 pattern using a standard UV photolithographic process. Next, the liquid precursor, polysilazane, was injected into the PDMS mold to fabricate free-standing SiCN microstructures. Finally, the solid polymer SiCN microstructure was cross-linked using hot isostatic pressure at $400^{\circ}C$ and 205 bar. The optimal pyrolysis and annealing conditions to form a ceramic microstructure capable of withstanding temperatures over $1400^{\circ}C$ were determined. Using the optimal process conditions, the fabricated SiCN ceramic microstructure possessed excellent characteristics includingshear strength (15.2 N), insulation resistance ($2.163{\times}10^{14}\;{\Omega}$, and BDV (1.2 kV, minimum). Since the fabricated ceramic SiCN microstructure has improved electrical and physical characteristics compared to bulk Si wafers, it may be applied to harsh environments and high-power MEMS applications such as heat exchangers and combustion chambers.

  • PDF

외기냉방을 이용한 냉방부하 절감 연구 (Reduction of Cooling Load using Outdoor Air Cooling)

  • 김민용;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.51-58
    • /
    • 2011
  • Due to enhanced sealing and insulation of buildings, extensive use of glasses for building envelopes and increased use of heat generating office equipments, energy consumption of modem buildings for cooling is steadily increasing. With outdoor air cooling(ODAC) system, cooling load can be reduced by exchanging indoor air with the cold outdoor air during spring and fall seasons. If ODAC is operated based only on temperature, total cooling load may virtually increase if the outdoor humidity is high. To overcome this problem, ODAC should be controlled based on enthalpy. In this work energy saving characteristics of enthalpy controlled ODAC is studied using dynamic simulation. The result shows that cooling load can be reduced by 27% by adopting ODAC.

기존 오피스건물 에너지성능지표에 따른 설계기법 연구 (A Study on the Design Technique for Energy Performance Indicators of Existing Office Buildings)

  • 정형태;이유나;김인수;안종욱
    • 에너지공학
    • /
    • 제27권3호
    • /
    • pp.28-35
    • /
    • 2018
  • 세계 각국에서는 환경오염이나 에너지절감을 위한 방안으로 건축물에 대한 가이드라인과 제도적 지원이 활성화되고 있다. 우리나라에서도 2013.09.01. 개정된 "건축물의 에너지절약 설계기준"에 따라 기준들이 마련되고 신축 건축물에 대한 제로에너지빌딩화가 권장사항에서 의무화과정으로 가고 있다. 그럼에도 불구하고 소형건물에 대한 정부의 구속력은 미비한 실정이다. 이에 최근에 시공한 오피스건물(외단열기법 적용)에 대해 에너지 절감효과를 분석하였고 추가적으로 에너지 절감을 위한 이중외피기법을 제안하였다.

PTFE 노즐로부터 발생하는 용삭가스를 고려한 스위칭 아크 해석 (Numerical Analysis of Switching Arcs with the Ablation of PTFE Nozzles)

  • 이원호;김홍규;이종철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1536-1537
    • /
    • 2011
  • The high-voltage circuit breaker plays an important role in the electrical system because there has been a need for suitable switching devices capable of initiating and interrupting the flow of the electric fault current. It continues as the contacts recede from each other and as the newly created gap is bridged by a plasma. The arc plasma happens inside the insulation nozzle of SF6 self-blast interrupter which is newly developed as the next-generation switching principle. The ablation of PTFE nozzle is caused by this high temperature medium, the PTFE vapor from the nozzle surfaces flows toward the outlets and the pressure chamber. The vapor makes the pressure of the chamber increased by heat and mass transfer from the arcing zone. Because the rate of ablation depends on the magnitude of applied current, it decreases when the current goes to zero. The compressed gas inside the chamber flows reversely toward the arc plasma during this moment. According to this principle, the arc can be cooled down and the fault current can be interrupted successfully. In this study, we calculate arc plasmas and thermal-flow characteristics caused by fault current interruption inside a SF6 self-blast interrupter, and to investigate the effect of PTFE ablation on the whole arcing history.

  • PDF

배전용 자기재 현수애자의 절연특성과 열화상 진단 (Insulation Characteristics and Thermography Diagnosis of Porcelain Insulators for the Distribution Systems)

  • 정종만;김동명;최명호
    • 전기학회논문지P
    • /
    • 제60권4호
    • /
    • pp.267-271
    • /
    • 2011
  • The insulating characteristics and temperature rise behaviors of porcelain suspension insulators were investigated. The testing insulators had used in the distribution systems normally and were sampled. Firstly, leakage current was measured and its impedance was calculated. The leakage current of good insulators is 0.2 mA and its impedance is 66 $M{\Omega}$. The worse insulators have lower impedance and the insulators having below 15 $M{\Omega}$ take place flashover at the high frequency voltage flashover test. Secondly, the temperature rise characteristics were analyzed depending on leakage current and its impedance. Surface temperature of insulators was measured for 30 minutes and until its saturation after voltage was applied. The temperature rise of insulators having 15 $M{\Omega}$ is about $14.5^{\circ}C$ above the ambient temperature. Lastly, the heating behaviors of 3 insulators in a string was analyzed. Any insulator in the string does not generate heat so far as it has at least one sound insulator. On the other hand, all the insulators in the string are bad if the string have any heating insulator.

1 kW급 가정용 연료개질기 성능 최적화 (Performance optimization of 1 kW class residential fuel processor)

  • 정운호;구기영;윤왕래
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.731-734
    • /
    • 2009
  • KIER has been developed a compact and highly efficient fuel processor which is one of the key component of the residential PEM fuel cells system. The fuel processor uses methane steam reforming to convert natural gas to a mixture of water, hydrogen, carbon dioxide, carbon monoxide and unreacted methane. Then carbon monoxide is converted to carbon dioxide in water-gas-shift reactor and preferential oxidation reactor. A start-up time of the fuel processor is about 1h and CO concentration among the final product is maintained less than 5 vol. ppm. To achieve high thermal efficiency of 80% on a LHV basis, an optimal thermal network was designed. Internal heat exchange of the fuel processor is so efficient that the temperature of the reformed gas and the flue gas at the exit of the fuel processor remains less than $100^{\circ}C$. A compact design considering a mixing and distribution of the feed was applied to reduce the reactor volume. The current volume of the fuel processor is 17L with insulation.

  • PDF

북한의 1월.8월 인체보온지수 분포의 특성 (The Characteristics of January and August Clo-Unit Distribution in North Korea)

  • 강철성
    • 한국지역지리학회지
    • /
    • 제10권1호
    • /
    • pp.151-157
    • /
    • 2004
  • 1월의 clo 값은 대체로 삼지연 지역이 가장 높게 나타나고, 장전 일대의 동해안 지역이 가장 낮게 나타난다. 또한 해안 지역보다 내륙 지역이, 동해안보다 서해안이 clo 값이 높게 나타난다. 이는 지형적 영향과 기온과 풍속의 지역적 차이에 기인한다. 8월에도 삼지연, 해산 일대, 개마고원 등이 높게 나타나는데, 이는 지형적 영향으로 기온 저하와 풍속의 증가로 나타나는 현상이다. 특히 8월에는 삼지연을 중심으로 북동-남서 내륙지역으로 등치선이 만곡하고, 이 축을 중심으로 한 이외의 지역이 비교적 낮은 분포를 보인다. 이러한 원인으로는 위도, 지형 및 장마 이후의 고온 다습한 북태평양 기단의 영향과 강한 일사에 의한 지면 복사열의 방출에 있다고 사료된다.

  • PDF

실리콘 코팅을 이용한 poly(ethylene naphthalate) 고온용 방열 필름의 제조 (Preparation of Poly(ethylene naphthalate) Film Coated with Silicones for High Temperature Insulator)

  • 이수;나차수
    • 한국응용과학기술학회지
    • /
    • 제24권2호
    • /
    • pp.167-173
    • /
    • 2007
  • The surface of poly(ethylene naphthalate) film applicable to high temerature insulator for convection microwave oven was modified with silicone coating solutions in the presence of silane crosslinking agent. The structure and properties of the PEN films were investigated by using Fourier transform IR spectroscopy, viscometry, microscopy, and tensile tests. The experimental results showed that the coating with silicone enhanced thermal stability up to $200^{\circ}C$, and slightly lowered the tensile strength and elongation of the PEN films. Judging from dimensional stability results the silicone coated PEN films can not be used for higher temperature insulator above $230^{\circ}C$. Serious dimensional contraction of films was obtained during heat treatment at $250^{\circ}C$ even for 1h. However, the surface of those films still have same chemical structure of silicones. Therefore, If we use PEN film prestretched at $230^{\circ}C$ as base one it will be possible to prepare a high temperature insulator up to $230^{\circ}C$. Conclusively, a silicone coated PEN film can be suitable for the application to convection microwave oven door insulator at high temperature up to $230^{\circ}C$.

전압 및 주파수 변화에 따른 저압 콘덴서 열 분포 해석 (Analysis for Thermal Distribution of Low-voltage Condenser by the Variance of Voltage & Frequency)

  • 김종겸
    • 조명전기설비학회논문지
    • /
    • 제24권4호
    • /
    • pp.43-49
    • /
    • 2010
  • 콘덴서는 유도성 부하의 늦은 역률 보상으로도 사용되며, 비선형 부하에서 발생하는 고조파를 저감하기 위해 리액터에 직렬로 연결하여 사용되기도 한다. 전압, 전류의 증가와 열의 발생은 콘덴서 수명에 많은 영향을 준다. 전압이 증가할 경우 전류가 증가하고, 주파수의 증가도 전류의 증가로 이어지기 때문에 전압과 주파수의 증가는 바로 열의 증가로 콘덴서 절연에 스트레스로 작용하여 고장의 원인을 제공할 수 있다. 본 연구에서는 전압의 크기와 주파수를 변화시킬 경우 콘덴서에서 발생하는 열의 분포도를 열화상 카메라로 측정하였다. 측정결과 전압과 주파수의 증가는 높은 열을 발생시켜 콘덴서의 수명을 단축시키는 요소로 작용함을 확인할 수 있었다.

LCD용 컬러필터 보호막 (Thin layer(Overcoat) for TFT-LCD color filter)

  • 김명구;박주현;임영택
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.273-273
    • /
    • 2006
  • Over the past years, a large number of acrylate polymers have been developed and the overcoat thin layer containing acrylate polymers have been used for TFT-LCD color filter. As forming thin layer using acrylate polymers, the existing acrylate polymers have some problems such as low hardness by low Tg temperature, coating uniformity and solubility in organic solvent. To solve these problems, we synthesized new polymer(Scheme.), containing olefin monomer, which has high Tg temperature, good coating uniformity and good solubility in organic solvent. The overcoat thin layer containing new polymer resulted in good coating uniformity, stain, spot, scratch, heat resistance, DOP(Degree Of Planarization) on RGB glass, transparency, hardness, adhesion, anti-chemicals(anti-acid, anti-base, anti-organic solvent), insulation and anti-humidity. Scheme. The structure of new polymer X = Olefin monomer contains ketone, ester, hydroxy, ether, halogen, nitrile, alkoxy, phenyl functional group $R_1$ and $R_2$= H or $CH_3$. Ratio=0<[1/(1+m+n)]<0.7,0.1[$\leq$[n/(1+m+n)]<0.5.

  • PDF