• Title/Summary/Keyword: Heat Input

Search Result 1,115, Processing Time 0.024 seconds

Characteristics of Hot-Film Type Micro-Flowsensors Fabricated on SOI Membrane and Trench Structures (SOI 멤브레인과 트랜치 구조상에 제작된 발열저항체형 마이크로 유량세선의 특성)

  • 정귀상;김미목;남태철
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.8
    • /
    • pp.658-662
    • /
    • 2001
  • This paper describes on the fabrication and characteristics of hot-film type micro-flowsensors integrated with Pt-RTD(resistance thermometer device) and micro-heater on the SOI(Si-on-insulator) membrane and trench structures, in which MGO thin-film was used as medium layer in order to improve adhesion of Pt thin-film to SiO$_2$ layer. Output voltages increased due to increase of heat-loss from sensor to external. The output voltage was 250 nV at N$_2$ flow rate of 2000 sccm/min, heating power of 0.3 W. The response time($\tau$:63%) was about 42 msec when input flow was step-input. The results indicated that micro-flowsensors with the SOI membrane and trench structures have properties of a high-resolution and ow consume power.

  • PDF

Simultaneous Consolidation of Titanium Diboride with Self-Propagating High-Temperature Synthesis, Direct Contact-Heating, and Pressure: Modeling of Temperature Distribution and the Relationship between Applied Energy and Densification ($TiB_2$ SHS 및 직접 접촉가열에 의한 동시 가압법 : 온도분포 모델링 및 공급에너지와 치밀화 관계)

  • Chung, G.K.;Cho, K.;Lee, H.B.
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.7
    • /
    • pp.817-824
    • /
    • 1995
  • TiB2 was simultaneously synthesized and densified with concurrent self-propagating high-temperature synthesis and direct contact-heating by electrcial power input and pressure. Density of TiB2 synthesized by self-propagating high-temperature synthesis and consolidated simultaneously by direct contact-heating and pressure was maximum 80% of the theoretical density (4.52g/㎤). Temperature profile was analyzed by solving heat balance equation with numerical method (FTCS method). The temperature of the sample was sufficiently raised to that temperature sufficient to be densified. It was ascertained that the density of the SHS synthesized TiB2 is exponentially proportinal to the input thermal energy per mass.

  • PDF

Optimization of Operational and Constitutional Geometric Parameters for Thermoaoustic Energy Output

  • Oh, Seung Jin;Shin, Sang Woong;Chen, Kuan;Chun, Wongee
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.28-38
    • /
    • 2014
  • The effects of geometric parameters (stack position, stack length, resonator tube length) and varying input power over acoustic energy output were investigated. The acoustic laser kit (Garret 2000) was used for the construction of TA lasers. A series of sound pressure level measurements in different orientations did not differ significantly confirming that the sound wave generated could be assumed as a spherical wave. An increase in acoustic pressure was recorded with respective increase in input power, stack and resonator tube lengths owing to their relative influence over heat transfer rate and critical temperature gradient across the stack.

Topology Optimization of Thermal Actuated Compliant Mechanisms (열 컴플라이언트 메커니즘의 위상 최적설계)

  • Lee, Won-Gu;Im, Min-Gyu;Park, Jae-Yong;Han, Seog-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.4
    • /
    • pp.434-439
    • /
    • 2010
  • A compliant mechanism is a mechanism that produces its motion by the flexibility of some or all of its members when input force or thermal load is applied. Whereas the topology optimizations based on homogenization and SIMP parameterization have been successfully applied for compliant mechanism design, ESO approach has been hardly considered yet for the optimization of these types of systems. In this paper, traditional ESO method is adopted to achieve the optimum design of a compliant mechanism for thermal load, since AESO method cannot consider the effect of both heat conduction and convection. Sensitivity number, a criterion for element removal in traditional ESO, was newly defined for input thermal loading. The procedure has been tested in numerical applications and compared with the results obtained by other methods to validate these approaches.

Fabrication of Micro-heaters Using MgO as Medium Layer and It`s Application for Micro-Flowsensors (매개층 산화마그네슘막을 이용한 백금박막 미세발열체의 제작과 마이크로 유량센서에의 응용)

  • 홍석우;조정복;정귀상
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.358-361
    • /
    • 1999
  • This paper describes on the fabrication and characteristics of hot-film type micro-flowsensors integrated with Pt-RTD\`s and micro-heater on the Si substrate, in which MgO thin-films were used as medium layer in order to improve adhesion of Pt thin-films to SiO$_2$ layer The MgO layer improved adhesion of Pt thin-films to SiO$_2$` layer without any chemical reactions to Pt thin-films under high as gas flow rate and its conductivity increased due to increase of heat-loss from sensor to external. Output voltage was 82 mV at N2 flow rate of 2000 sccm/min, heating power of 1.2W. The respons time was about 100 msec when input flow was step-input

  • PDF

The fabrication of high-response time, low consumption power, microflowsensor and its characteristics (고속응답, 저소비전력형 마이크로 유속센서의 제작과 그 특성)

  • 홍석우;김병태;김길중;정귀상
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.343-346
    • /
    • 2000
  • This paper presents the characteristics of low consumption, high-response time hot-film type micro-flowsensors with SOI(Si-on-insulator) and trench structures. Output voltages increased due to increase of heat-loss from sensor to external. Compared with no-trench on the SOI structure, the micro-flowsensors with trench structures have properties of high output voltage and low consume power. Output voltage of micro-flowsensors with SOI and trench structures was 250 mV at $N_2$ flow rate of 2000 sccm/min, heating power of 0.3 W. The response time was about 85 msec when input flow was step-input.

  • PDF

Experimental Study on the Coefficient of Performance of a Small Absorption Refrigerator (소형 흡수식 냉동기의 성적계수에 관한 실험적 연구)

  • Lee Sun Kyoo;Kim Sang Soo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.2
    • /
    • pp.176-184
    • /
    • 1987
  • The purpose of this research is to study the characteristics of the coefficient of perform-ance (COP) of the small absorption refrigeration system. This experimental study is performed with two selected variables, the temperature of the generator and the input temperature of the cooling water. In order to determine the input temperature of the generator which gives maximum COP, the experimental data are obtained with controlling the temperature of the generator in the range of $20-32^{\circ}C$ of the temperature of the cooling water. The range of the generator heat suppling temperature which gives maximum efficiency is about $90-95^{\circ}C.$ The temperature range depends on the characteristics of the equipment unit. The most important result in this experiment is the trends of the COP in accordance with the variation of these temperatures. This trend will furnish the informations and knowledges for designing and operating the absorption refrigerator.

  • PDF

Noise Reduction of PDP TV Using Multi-dimensional Spectral Analysis Method (다차원 스펙트럼 해석법을 이용한 PDP TV의 저소음화)

  • Yang, In-Hyung;Jeong, Jae-Eun;Kwak, Hyung-Taek;Oh, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.1
    • /
    • pp.81-88
    • /
    • 2011
  • The method is introduced for estimating the noise source contribution on the noise of PDP TV in a multiple-input system where the input sources may be coherent with each other. By the coherence function method, it is found that the biggest part of the noise source in the PDP TV noise is generated by the PCB boards which consume high power and produce high heat. This analysis is modeled as three-input/single-output system because the noise is generated by three main boards, X-board, Y-board, SMPS that are located close to each other. The coherence function method is proved to be useful tool for identifying of noise source. In this study, Transfer Path Analysis using MDSA is implemented to determine the quantitative noise contribution of each board for PDP TV with the rear case closed and with the rear case open. And the possibility of noise reduction is confirmed through the experimental method that isolates the most contributing board by adding sound-absorbing materials to it.

Characteristic Analysis of a Small ALIP for the Developing of the Liquid Sodium (액체 소듐 순환 구동용 소형 환단면 선형유도전자펌프의 특성 분석)

  • Kim, Hee-Reyoung;Kim, Jong-Man;Nam, Ho-Yun;Hwang, Jong-Sun;Seo, Jang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.1-3
    • /
    • 1999
  • EM (ElectroMagnetic) pump is used for the purpose of transporting liquid sodium coolant with electrical conductivity in the LMR(Liquid Metal Reactor). (In the present study, pilot EM pump has been designed by using of equivalent circuit method which is commonly employed to analyze linear induction machines for the test of removal of residual heat. The length and diameter of the pump have fixed values of 840 mm and 101.6 mm each by taking account of geometrical size of circulation loop for the installation of EM pump. Flowrate versus developing pressure is related from Laithwaite's standard design formula and the characteristic analyses of developing force and efficiency are carried out according to change of input frequency. From the characteristic curve, input frequency of 13 Hz is determined as the design frequency. On the other hand, The annular air gap size of 6.05 mm is selected not to bring about too much hydraulic loss. Resultantly design analysis makes pump have the electrical input of 604 VA and the hydrodynamical capacity of 1.3 bars and 40 l/min.

  • PDF

Experimental Study on the Thermal Performance of Piezoelectric Fan in an Enclosure (밀폐공간 내에서 압전세라믹 냉각홴의 열성능에 대한 실험적 연구)

  • Park, Sang-Hee;Choi, Moon-Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.12 s.255
    • /
    • pp.1173-1180
    • /
    • 2006
  • This study deals with fluid flow and heat transfer around a module cooled by forced air flow generated by a piezoelectric(PZT) fan in an enclosure. The fluid flows were generated by a flexible PZT fan which deflects inside a fluid transport system of comparatively simple structure mounted on a PCB in an enclosure($270\times260\times90mm^3$). Input voltages of 30V and 40V, and a resonance frequency of 28Hz were used to vibrate the cooling fan. Input power to the module was 4W. The height in an enclosure was changed 23$\sim$43mm. The fluid flow around the module was visualized by using PIV system. The temperature distributions around a heated module were visualized by using liquid crystal film. As the height in an enclosure and the input voltage of PZT fan increased, the cooling effect of module using a PZT fan increased. We found that the flow type was T- or Y-shape and the cooling effect was increased by the wake generated by a PZT fan.