• Title/Summary/Keyword: Heat Cycle

Search Result 1,588, Processing Time 0.034 seconds

A Numerical Study on the Thermal Behavior Evaluation of Bentonite Buffer (벤토나이트 완충재의 열적 거동 평가에 관한 수치해석적 연구)

  • Yoon, Chan-Hoon;Choi, Young-Chul;Choi, Heui-Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.2
    • /
    • pp.99-112
    • /
    • 2015
  • In this study, laboratory test equipment was designed and installed to evaluate the thermal behavior of bentonite, which is used as a buffer in high-level waste disposal systems. The thermal analysis was conducted to verify the test results using ABAQUS, a finite element analysis code. In view of the seasonal changes seen during the test, the thermal behavior of bentonite with a temperature of outside air was evaluated. Of the cases examined, the results of the analysis model using stainless steel (Case 3) approximates to the test results, showing an error of about 1℃. The results of the thermal analysis into seasonal temperature distributions are consistent with trends seen in lab-test results. These analyses show that the effects of the thermal conductivity of the material surrounding the buffer and outside air temperature, are very important factors in the thermal behavior of bentonite. In the future, it is expected that a moisture saturation test of a bentonite buffer containing a heat source will be carried out. Therefore, the development of a numerical analysis model is required for the prediction and verification of the laboratory test results.

Characteristics of the Simulated ENSO in CGCM (대기-해양 접합 모델에서 모사한 ENSO의 특징)

  • Moon, Byung-Kwon
    • Journal of the Korean earth science society
    • /
    • v.28 no.3
    • /
    • pp.343-356
    • /
    • 2007
  • This paper explored the characteristics of the interannual sea surface temperature (SST) variability in the equatorial Pacific by analyzing the simulated data from a newly coupled general circulation model (CGCM). The CGCM simulates well the realistic ENSO variability as well as the mean climatologies including SST, seasonal cycle, precipitation, and subsurface structures. It is argued that the zonal gradient of SST in the equatorial Pacific is responsible for the over-energetic SST variability near the equatorial western boundary in the model. This variability could also be related to the strong westward propagation of SST anomalies which resulted from the enhanced the zonal advection feedback. The simple two-strip model supports this by sensitivity tests. Analysis of the relationship between zonal mean thermocline depth and NINO3 SST index suggested that the ENSO variability is controlled by the recharge-discharge oscillator of the model. The lead-lag regression result reveals that heat buildup process in the western equatorial Pacific associated with the increase of the barrier layer thickness (BLT) is a precedent condition for El $Ni\widetilde{n}o$ to develop.

Experimental Study on Performance Characteristics of Air Driven Scroll Expander (공기구동 스크롤 팽창기 성능특성에 관한 실험적 연구)

  • Song, Wonbin;Kwak, Chul Woo;Kim, Tae Kyun;Kim, Ju Young;Kim, Kwang Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.6
    • /
    • pp.50-54
    • /
    • 2016
  • The performance of a scroll expander is the most important factor for the efficiency of small scale Organic Rankine cycle waste heat power generation systems. In this research, a scroll compressor was purchased and operated in reverse to function as a scroll expander. With air as a working fluid, a series of performance test were conducted on this expander by varying the inlet and outlet pressure. Secondly, We have tested through 2000 to 3500 rpm rotational speed to find the maximum power and efficiency of the expander. And last, It was observed in the initial experiments that the design of the expander's orbiting scroll wrap partially blocked the fluid intake which may have caused unnecessary flow resistance. To verify this theory, a small part of the scroll wrap was removed and the performance test was redone. It was observed that the lower back pressure assure the higher efficiency and power of expander and the rotational speed that shows maximum adiabetic efficiency of scroll expander is 69% at 2500 rpm. And by modified wrap of the scroll, we could get volume flow rate for 13% to 19% and power for 5% to 18% increased. But the maximum efficiency of the modified scroll was decreased 8%.

A Study on the Thermal Designs of 300 MW-Class IGCC Plant (300 MW급 IGCC 플랜트의 열 설계 연구)

  • 이윤경;서석빈;김종진
    • Journal of Energy Engineering
    • /
    • v.11 no.2
    • /
    • pp.81-89
    • /
    • 2002
  • IGCC (Integrated Coal Gasification Combined Cycle) is a technology that generates electric power using coal gasification and gasified fuel. Carbon conversion value of IGCC is higher and the influence on the environment is lower than the pulverized coal power plant. Especially, in the nations where the weight of fossil fuel for power generation is remarkably high like in Korea, IGCC stands out as an alternative plan to cope with sudden limitation for the emissions. In this paper, system design study for the commercial IGCC system which the introduction is imminent to Korea was performed. Two cases of entrained gasification process are adapted, one is FHR(full heat recovery) type IGCC system for high efficiency and the other is Quench type IGCC system for low cost. System simulations using common codes like AspenPlus were performed for each system. In the case of Quench system, system option study and sensitivity analysis of the air extraction rate was performed. Thermal performance result for the FHR system is 42.6% (HHV, Net) and for the quench system is 40% (HHV, net) when 75% air is extracted.

Observation of Estrus and Control of Abnormal Estrus in Cattle and Pig (소와 돼지에서 발정관찰과 이상발정의 대책)

  • 김창근
    • Korean Journal of Animal Reproduction
    • /
    • v.7 no.2
    • /
    • pp.72-85
    • /
    • 1983
  • This presentation firstly is discussed the characteristics of estrus, the time of first postpartum estrus, and the relative accurate of various estrus detection aids and secondly discussed the abnormalities of estrus and ovarian function and its control by treatment of exogenous hormones in cattle and pig. Longer estrus cycles as well as the shorter than 18 day cycles showed the lowered conception rates as compared to the normal cycles of 18 to 25 days. Other characteristics of est겨s such as duration of estrus, intensity of estrus and time of estrus are reviewed to affect fertility. The first postpartum ovulation and estrus in cows usually occurs about 20 to 30 days and 40 to 50 days after parturition, respectively. Irregularities in estrus cycle length have been conducted during early postpartum period. In sows, weaning is followed by ovulation and estrus although there is some individual variation. The most common method of estrus detection is direct visual observation on standing estrus behavior, but various aids of estrus detection have been empolyed with varying degree of effectiveness. The results from heat detector devices are about as accurate as twice-daily observation(about 90%). The abnormal estrus can be classified into three types; irregular or continuous estrus, silent estrus and anestrus. Cystic ovarian disease, follicular cysts and luteal cysts, is a serious cause of reproductive failure in cattle and pig. The follicular cysts are much more common than luteal cysts and the incidence of ovarian cysts in dairy cattle is higher than beef cattle and pig. The occurrences of ovarian cysts have been closely associated with levels of milk production, stages of postpartum period, nutritional levels and seasons. The luteal cysts and persistent corpora lutea are responsive to the luteolytic effects of the recently synthetic analogues of PGF2$\alpha$ in cows and sows and recently GnRH or LH-RH has been successfully used as a treatment for cows and sows with ovarian follicular cysts.

  • PDF

A Study on the Analysis and the Improvement of Land and Sea Breeze Model Experiment suggested to 2009 Revised Elementary Science Curriculum (2009 개정 교육과정 초등과학에서 제시된 해륙풍 모형실험 분석 및 개선 방안)

  • Kang, Houn Tae;Lee, Gyuho;Noh, Suk Goo
    • Journal of Korean Elementary Science Education
    • /
    • v.36 no.1
    • /
    • pp.1-15
    • /
    • 2017
  • The purpose of this study is to analyze the problems of land and sea breeze model experiment that has presented in $5^{th}$ grade curriculum in chapter "Weather and our lives" and makes better model simulation so that learners can have better and more effective way to study it. To survey the opinions from dedicated teachers about land and sea breeze model experiment, we produced the survey through interview with science exclusive teacher from M elementary school. An elementary science education expert, 3 men of science EdD modified and complemented survey and started Delphi survey to 12 science teachers who have career teaching more than 3 years. The problems found in this survey were 'one heat bulb, short heating time, small temperature difference of water and sand, lack of class time, empty space between sand and water, back of transparent boxes, little amount of scent and the location of the it' etc. But the most of all, it is hard to see the successful result of the experiment. Based on these kinds of investigations, and lots of trial and error, redesigned the new model experiment that has the most similarity to the real one and high probability of success. According to this, it was able to see the smoke forms horizontal movement along the sand and the smoke goes in one circulation cycle. through this experiment, we made a conclusion that although those scientific experiments in textbook were developed through lots of considerations of expert, to consider the aspect of consumer, it needs to reach the educational agreement about simulation experiment so that It can lead to successful experiment and high quality education.

Performance Analysis of New Working Solution for Absorption Refrigeration Machine using Treated Sewage (하수처리수이용 신용액 흡수식 냉동기의 성능해석)

  • 권오경;유선일;윤정인
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.231-240
    • /
    • 1998
  • The global environmental problems such as CFC, energy losses in heat recovery system as well as summer peak time power demands, the development of high efficiency absorption refrigeration systems is one of the most promising method in this problems. The absorption refrigeration system to utilize treated sewage is available for environmental protection and energy conservation. Simulation analysis on the double-effect absorption refrigeration cucles with parallel or series flow type has been performed. LiBr+LiI+LiCl+LiNO$_3$ solution was selected as the new working fluid. The main purpose of this study is evaluating the possibilities of effective utilization of treated sewage as a cooling water for the absorber and condenser. The other purpose of the present study is to determine the optimum designs and operating conditions based on the operating constraints and the coefficient of performance in the parallel or series flow type. In this study, we found out the characteristic of new working solution through the cycle simulation and compared LiBr solution to evaluate. The absorption refrigeration machine using the new working fluid was obtained better results COP rise and compactness of system by comparison with LiBr solution.

  • PDF

Physical Properties of Estrus Mucus in Relation to Conception Rates in Dairy Cattle

  • Lim, Hyun-Joo;Son, Jun-Kyu;Yoon, Ho-Beak;Baek, Kwang-Soo;Kim, Tae-Il;Jung, Yeon-Sub;Kwon, Eung-Gi
    • Journal of Embryo Transfer
    • /
    • v.29 no.2
    • /
    • pp.157-161
    • /
    • 2014
  • The study aimed to determine the physical characteristics of estrus mucus and conception rates in dairy cattle. Samples of estrus mucus from the cervix were collected from 108 dairy cattle during heat and were examined for color and consistency. Samples were taken from bred animals at starting from day of breeding to the completion of one estrus cycle. The color of the cervical mucus was studied based on its transparency while the consistency was based on the thinness and thickness of the cervical mucus. The dairy cattle were bred and the pregnancy diagnosis was performed at the $60^{th}$ day post breeding. Findings showed that the estrus mucus of the dairy cattle was transparent in 58.3%, turbid in 31.5% and dirty in 10.2%. It was further observed that the mucus consistency of the dairy cattle was thin in 74.1% and thick in 25.9%. In the pregnant group, 67.3% mucus samples were found transparent, turbid in 23.6% and dirty in 9.1%. However, the corresponding figures for the non-pregnant group had 49.1%, 39.6% and 11.3%. The consistency of cervical mucus was found to be thin in 74.1% and thick in 25.9% of dairy cattle. The conception rates of dairy cattle with thin and thick consistency of cervical mucus were 81.8% and 18.2%, respectively. Pregnant was associated with consistency of cervical mucus (p<0.10). Findings indicated that dairy cattle with thin consistency of cervical mucus and had clear discharge were pregnant cows.

Corrosion Analysis of Materials by High Temperature and Zn Fume (고온 및 Zn Fume에 의한 소재들의 부식성 분석)

  • Baek, Min Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.551-556
    • /
    • 2018
  • The material normally used in hot dip galvanizing facilities is SM45C (carbon steel for mechanical structure, KS standard), mainly because of its price. During this process, the oxidation of the plating facility occurs due to the heat of the Zn fumes coming from the molten zinc. Since the cycle time of the current facilities is 6 months, much time and money are wasted. In this study, the corrosive properties of various materials (Inconel625, STS304, SM45C) were investigated by oxidation in a high temperature and Zn fumes environment. The possibility of applying the hot-dip galvanizing equipment was investigated for each material. The Zn fumes were generated by directly bubbling Ar gas into Zn molten metal in a 650 degree furnace. High-temperature, Zn fumes corrosion was conducted for 30 days. The sample was removed after 30 days and the oxidation of the surface was confirmed with EDS and SEM, and the corrosion properties were examined using potentiodynamic polarization tests.

Analyses on Thermal Stability and Structural Integrity of the Improved Disposal Systems for Spent Nuclear Fuels in Korea

  • Lee, Jongyoul;Kim, Hyeona;Kim, Inyoung;Choi, Heuijoo;Cho, Dongkeun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.spc
    • /
    • pp.21-36
    • /
    • 2020
  • With respect to spent nuclear fuels, disposal containers and bentonite buffer blocks in deep geological disposal systems are the primary engineered barrier elements that are required to isolate radioactive toxicity for a long period of time and delay the leakage of radio nuclides such that they do not affect human and natural environments. Therefore, the thermal stability of the bentonite buffer and structural integrity of the disposal container are essential factors for maintaining the safety of a deep geological disposal system. The most important requirement in the design of such a system involves ensuring that the temperature of the buffer does not exceed 100℃ because of the decay heat emitted from high-level wastes loaded in the disposal container. In addition, the disposal containers should maintain structural integrity under loads, such as hydraulic pressure, at an underground depth of 500 m and swelling pressure of the bentonite buffer. In this study, we analyzed the thermal stability and structural integrity in a deep geological disposal environment of the improved deep geological disposal systems for domestic light-water and heavy-water reactor types of spent nuclear fuels, which were considered to be subject to direct disposal. The results of the thermal stability and structural integrity assessments indicated that the improved disposal systems for each type of spent nuclear fuel satisfied the temperature limit requirement (< 100℃) of the disposal system, and the disposal containers were observed to maintain their integrity with a safety ratio of 2.0 or higher in the environment of deep disposal.