• 제목/요약/키워드: Heat Condition

검색결과 3,940건 처리시간 0.026초

열펌프 성능향상을 위한 공기 열교환기 부착효과 (Attachment of the Air Heat Exchanger for COP Improvement in the Heat Pump)

  • 노정근;송현갑;박용규
    • Journal of Biosystems Engineering
    • /
    • 제27권3호
    • /
    • pp.235-240
    • /
    • 2002
  • Performance of the heat pump with attaching an air heat exchanger was investigated in the heating condition when the air heat exchanger was worked in the ambient air temperature of -5 to 11$\^{C}$ and air flow rate of 542 to 747 ㎡/h. Performance tests for heating condition were conducted in an experimental room equipped with heat pump. The performance tests were performed in a ambient temperature of -4 ∼ 11$\^{C}$, and room temperature of 4∼22$\^{C}$ respectively. Measured data(temperature, capacity of heat transfer and consumption of electronic power) were analyzed to the efficiency of HEEVA(Heat Exchanger fur the Evaporator), overall heat transfer coefficient and COP of heat pump. The results of inlet temperature for evaporator increased that the temperature was 2 ∼6$\^{C}$, and inlet temperature for condenser decreased that the temperature was 3 ∼ 8$\^{C}$. The results of comparing efficiency of HEEVA for the ratio of heat exchange between hot air and cold air showed that efficiency were considered to 91% because of the ratio of 83∼98%. The results of comparing of COP for the heat pump increased that improvement COP was approximately 0.3∼7.5 than HEEVA had not been operated.

배기열 회수용 종이 열교환기의 성능에 영향을 미치는 인자에 관한 연구 (A Study on the Factors Affecting the Performance of Paper Heat Exchanger for Exhaust Heat Recovery)

  • 정민호;유성연
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.956-964
    • /
    • 2005
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery The purpose of this research is to find the factors affecting the performance of paper heat exchanger for exhaust heat recovery, which can be applied directly to the conventional ventilation unit, air-purifier, and air-conditioning system. In this study, thermal performance and pressure loss of the paper heat exchanger are measured and compared at various operating conditions. The effectiveness of sensible, latent and total heat at the face velocity of 0.75 m/s are $77\%,\;47\%\;and\;57\%$ in the cooling condition and $77\%,\;59\%,\;and\;\%$ in the heating condition, respectively. The effectiveness for sensible heat is only affected by velocity. On the other hand, the effectiveness for latent heat is affected. by temperature and relative humidity.

자원순환형 소각열 이용시스템에 관한 평가 (Evaluation on Utilizing Systems of Incineration Heat as Resource cycling Type)

  • 정용현
    • 한국환경과학회지
    • /
    • 제12권4호
    • /
    • pp.503-510
    • /
    • 2003
  • How to plan the energy system is one of the keys f3r constructing the Environment -Friendly City. for this reason, a great number of surveys for utilizing unused energy have conducted by a planner. In regard to unused energy, the heat from incineration plants classify as a unused energy having high-exergy-energy. From this point of view, It is studied about the plant systems providing heat to district heating & cooling(D.H.C) and producing electric power. It is divided four system models as system I (10K [kgf/cm$^2$) vapor as outlet of boiler, supply far 10K vapor and return to 60$^{\circ}C$ as supply condition of district heating), system II (30 K vapor as outlet of boiler, supply for 5t vapor and return to 60f as supply condition of district heating), system 111 (30 K vapor as outlet of boiler, supply for 85$^{\circ}C$ hot water and return to 60$^{\circ}C$ as supply condition of district heating), system IV (30 K vapor as outlet of boiler, supply for 47$^{\circ}C$ hot water and return to 40t as supply condition of district heating). The results from the upper condition of four system, System II got a proper on economical benefits and system IV calculated as benefiting on energy saving effects, and suggest indifference curve as the total evaluation method of both economical benefits and energy saving.

열교환기를 이용한 저온 환경 구축에 대한 기초 연구 (A Preliminary Study of Low Temperature Condition by Heat Exchanger)

  • 이양석;양재준;김유;고영성;임병준
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.23-26
    • /
    • 2007
  • 본 연구에서는 고공 환경을 모사하기 위해 선행되어야 할 저온 환경 구축에 대한 기초 실험을 수행하였다. 열교환기를 이용하여 공기를 극저온으로 냉각 시키고, 상온의 공기를 혼합하여 온도 특성을 고찰하였다. 오리피스를 사용하여 각각의 유량을 제어할 수 있는 시스템을 구축하였으며, 열교환을 위하여 액체질소를 사용하였다. 열교환기를 통하여 냉각된 공기의 온도를 일정하게 유지시키면서 상온의 공기를 혼합시킨 결과 상온의 공기 유량이 증가함에 따라 혼합 공기의 온도도 거의 선형적으로 증가함을 확인하였다. 이에 따라 저온 환경 구축에 필요한 다양한 유량의 저온 공기를 생성할 수 있는 가능성을 확보하였다.

  • PDF

Performance, hemato-biochemical indices and oxidative stress markers of broiler chicken fed phytogenic during heat stress condition

  • Olatunji Abubakar, Jimoh;Olajumoke Temidayo, Daramola;Hafsat Ololade, Okin-Aminu;Olayinka Abosede, Ojo
    • Journal of Animal Science and Technology
    • /
    • 제64권5호
    • /
    • pp.970-984
    • /
    • 2022
  • Thermal stress is a tremendous health predicament encountered by poultry farmers with adverse effects on the performance, product stature, health condition, survival, and overall welfare of poultry birds, and so requires urgent dietary user-friendly strategy to curb. This study was conducted with 200-day old broilers for the purpose of investigating the potential of phytogenics in refining the negative effects of heat stress on broiler chicken. Moringa, Phyllanthus and mistletoe leaves were processed as phytogenic supplements and incorporated into standard ration for broilers as treatments B1 (control), B2, B3 and B4 diet during the peak of thermal discomfort in humid tropics. Growth and carcass indices were monitored in a 49-day trial and blood samples were harvested at the end of the ordeal period to assess haematology, serum biochemical and oxidative stress markers with the use of standard procedures. The results obtained showed that the prevailing environmental condition in the study site indicated that the birds were exposed to heat stress. Birds fed on moringa and mistletoe supplements had higher performance index than birds without supplementation during heat stress condition, while birds fed on mistletoe supplement had the highest survival rate across the treatments. The liveweight, slaughter weight, dressed weight and eviscerated weight of heat stressed birds fed on moringa, phyllanthus and mistletoe supplements were significantly higher than birds on control treatment. Heterophyl/lymphocyte ratio of heat stressed birds without supplement were higher than birds on phytogenic supplements, with least values recorded in phyllanthus and mistletoe fed birds. Birds on phytogenic supplement tend to have lower cholesterol profile, lipid peroxidation and better antioxidant profile than birds on control treatment during heat stress conditions. Mistletoe supplementation in broiler ration enhances the survival rate, as well as promotes growth indices better among the phytogenic supplements. However, phytogenic supplements did ameliorate the negative effects of thermal discomfort on performance, physiological and oxidative stress in heat-stressed broiler chicken.

공랭형 수직평판 흡수기 액막에서의 열 및 물질전달에 관한 수치적 연구 (A Numerical Study on Heat and Mass Transfer in a Falling Film of Vertical Plate Absorber Cooled by Air)

  • 김선창;오명도;이재헌
    • 대한기계학회논문집
    • /
    • 제19권4호
    • /
    • pp.1071-1082
    • /
    • 1995
  • Numerical analyses have been performed to obtain the absorption heat and mass transfer coefficients and the absorption mass flux from a falling film of the LiBr aqueous solution which is cooled by cooling air. Heat flux at the wall is specified in terms of the heat transfer coefficient of cooling air and the cooling air temperature. Effects of operating conditions, such as the heat transfer coefficient, the cooling air temperature, the system pressure and the solution inlet concentration have been investigated in view of the local absorption mass flux and the total mass transfer rate. Effects of film thickness and film Reynolds number on the heat and mass transfer coefficients have been also estimated. Analyses for the constant wall temperature condition have been also carried out to examine the reliability of present numerical method by comparing with previous investigations.

변화하는 밀도와 비열을 고려한 고속 저어널 베어링의 열유체 윤활해석 I-축 속고영향 (Thermohydrodynamic Lubrication Analysis of High Speed Journal Bearing Considering Variable Density and Specific Heat: Part I - Shaft Speed Effect)

  • 전상명;장시열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집C
    • /
    • pp.287-292
    • /
    • 2001
  • Under the condition of variable density and specific heat, maximum pressure, maximum temperature, bearing load, friction and side leakage in high-speed journal bearing operation are examined. The results are compared with the calculation results under the conditions of constant density and specific heat, and variable density and constant specific heat. It is found that the condition of variable density and specific heat play important roles in determining friction and load of journal bearing at high speed operation.

  • PDF

단일(單一) 긴 수직평판(垂直平板)핀을 가진 수평전도관(水平傳導管)으로 부터의 자연대류(自然對流) (Conjugate Heat Transfer by Natural Convection from a Horizontal Heat Exchanger Tube with a Long Vertical Longitudinal Plate Fin)

  • 배대석;권순석
    • 설비공학논문집
    • /
    • 제1권1호
    • /
    • pp.64-72
    • /
    • 1989
  • Laminar natural convection heat transfer from a horizontal heat exchanger tube with one infinitely long vertical plate fin has been studied by a finite-difference numerical procedure. In predicting convective heat transfer from a circular tube, the thermal boundary condition at solid fluid interface is usually assumed to be isothermal. However, in reality, the thermal boundary condition is not isothermal, and the tube has the thickness and the conductivity. So the temperature at the interface is not known a priori to the calculation. This problem has the conjugate phenomena which occur between the tube conduction and external natural convection, and between the fin conduction and external natural convection. Numerical results are obtained to determine the effects of the conductivity of solid wall and the thickness of tube wall on heat transfer. It is found that the conduction causes significant influence on the natural convection heat transfer at low K and high ${\delta}$.

  • PDF

히트펌프 냉·난방 시스템의 온도 자동제어에 관한 연구 (A Study for Automatic Temperature Control of the Heating-Cooling System with Heat Pump)

  • 구창대
    • 한국산업융합학회 논문집
    • /
    • 제14권4호
    • /
    • pp.143-149
    • /
    • 2011
  • The experiment has been investigated the room temperature change under adjusting 4-way valve which was installed for cooling and heating switch. Beside, the temperature of heat pump was controlled automatically for autonomously adjusting temperature and maintaining a constant room temperature. As results, Inlet & outlet temperature differences of compressor are $95^{\circ}C$ in cooling condition and $57^{\circ}C$ in heating condition. Therefore, Compression efficiency of cooling effect is higher than heating effect. In addition, Heat exchange effect of Cooling system condition is higher than heating system. This results can be used for studying about automatic temperature control of cooling and heating system with heat pump and 4way valve.

고온용 세라믹 열교환기 설계를 위한 수치 연구 (A Numerical Simulation for Design of High Temperature Ceramic Heat Exchanger)

  • 박경서;최종균;남진현;신동훈;박상환
    • 한국연소학회지
    • /
    • 제14권3호
    • /
    • pp.24-28
    • /
    • 2009
  • To improve its efficiency, most of the industrial furnace had been used recuperator. However, commonly used metal recuperator is not suitable under condition of temperature higher than $1000^{\circ}C$. The other hand, ceramic recuperator is able to use in high temperature condition. In the present study, the design program based on the basic heat exchanger design theory, and CFD modelling are applied to ceramic recuperator to verify the design results. Using design program to find the optimum design factor on the variation of recuperator condition. The result of this study are as follows : Thinner fin-plate thickness reduces pressure drop and increases heat-transfer rate, However, thin plate or plate with thin thickness(< 5 mm) is difficult to manufacture, due to limited mechanically strength.

  • PDF