• Title/Summary/Keyword: Healthcare Devices

Search Result 421, Processing Time 0.029 seconds

The Effect of Communication Distance and Number of Peripheral on Data Error Rate When Transmitting Medical Data Based on Bluetooth Low Energy (저 전력 블루투스 기반으로 의료데이터 전송 시 통신 거리와 연동 장치의 수가 데이터 손실률에 미치는 영향)

  • Park, Young-Sang;Son, ByeongJin;Son, Jaebum;Lee, Hoyul;Jeong, Yoosoo;Song, Chanho;Jung, Euisung
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.259-267
    • /
    • 2021
  • Recently, the market for personal health care and medical devices based on Bluetooth Low Energy(BLE) has grown rapidly. BLE is being used in various medical data communication devices based on low power consumption and universal compatibility. However, since data errors occurring in the transmission of medical data can lead to medical accidents, it is necessary to analyze the causes of errors and study methods to reduce data error. In this paper, the minimum communication speed to be used in medical devices was set to at least 800 byte/sec based on the wireless electrocardiography regulations of the Ministry of Food and Drug Safety. And the data loss rate was tested when data was transmitted at a speed higher than 800 byte/sec. The factors that cause communication data error were classified, and the relationship between each factor and the data error rate was analyzed through experiments. When there were two or more activated peripherals connected to the central, data error occurred due to channel hopping and bottleneck, and the data error rate increased in proportion to the communication distance and the number of activated peripherals. Through this experiment, when the BLE is used in a medical device that intermittently transmits biosignal data, the risk of a medical accident is predicted to be low if the number of peripherals is 3 or less. But, it was determined that BLE would not be suitable for the development of a biosignal measuring device that must be continuously transmitted in real time, such as an electrocardiogram.

Intelligent Hospital Information System Model for Medical AI Research/Development and Practical Use (의료인공지능 연구/개발 및 실용화를 위한 지능형 병원정보시스템 모델)

  • Shon, Byungeun;Jeong, Sungmoon
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.67-75
    • /
    • 2022
  • Medical information is variously generated not only from medical devices but also from electronic devices. Recently, related convergence technologies from big data collection in healthcare to medical AI products for patient's condition analysis are rapidly increasing. However, there are difficulties in applying them because of independent developmental procedures. In this paper, we propose an intelligent hospital information system (iHIS) model to simplify and integrate research, development and application of medical AI technology. The proposed model includes (1) real-time patient data management, (2) specialized data management for medical AI development, and (3) real-time monitoring for patient. Using this, real-time biometric data collection and medical AI specialized data generation from patient monitoring devices, as well as specific AI applications of camera-based patient gait analysis and brain MRA-based cerebrovascular disease analysis will be introduced. Based on the proposed model, it is expected that it will be used to improve the HIS by increasing security of data management and improving practical use through consistent interface platformization.

Setting Priority Criteria for Classification of Self-Testing In Vitro Diagnostic Medical Devices Using Analytic Hierarchy Process Technique (Analytic Hierarchy Process 기법을 활용한 개인용 체외진단의료기기 분류기준에 대한 우선순위 연구)

  • Seol-Ihn Kim;Do-Yun Pyeon;Yong-Ik Jeong;Jahyun Cho;Gaya Noh;Green Bae;Hye-Young Kwon
    • Health Policy and Management
    • /
    • v.33 no.2
    • /
    • pp.173-184
    • /
    • 2023
  • Background: The coronavirus disease 2019 pandemic has been challenging the healthcare service, i.e., the vitalization of the point of care accompanying self-testing in vitro diagnostic medical devices (IVDs). This study aims to suggest priority criteria to classify self-testing IVDs using the analytic hierarchy process technique. Methods: Two dimensions of the characteristics embedded in the IVDs and the diseases to be diagnosed with self-testing IVDs were parallelly considered and independently investigated. In addition, three expert panels consisting of laboratory medical doctors (n=11), clinicians (n=10), and citizens (n=11) who have an interest in the selection of self-testing IVDs were asked to answer to questionnaires. Priorities were derived and compared among each expert panel. Results: First of all, ease of specimen collection (0.241), urgency of the situation (0.224), and simplicity of device operation (0.214) were found to be the most important criteria in light of the functional characteristics of self-testing IVDs. Medical doctors valued the ease of specimen collection, but the citizen's panel valued self-management of the disease more. Second, considering the characteristics of the diseases, the priority criteria were shown in the order of prevalence of diseases (0.421), fatality of disease (0.378), and disease with stigma (0.201). Third, medical doctors responded that self-testing IVDs were more than twice as suitable for non-communicable diseases as compared to communicable diseases (0.688 vs. 0.312), but the citizen's group responded that self-testing IVDs were slightly more suitable for infectious diseases (0.511 vs. 0.489). Conclusion: Our findings suggested that self-testing IVDs could be primarily classified as the items for diagnosis of non-communicable diseases for the purpose of self-management with easy specimen collection and simple operation of devices, taking into account the urgency of the situation as well as prevalence and fatality of the disease.

Analyzing Technological Convergence for IoT Business Using Patent Co-classification Analysis and Text-mining (특허 동시분류분석과 텍스트마이닝을 활용한 사물인터넷 기술융합 분석)

  • Moon, Jinhee;Gwon, Uijun;Geum, Youngjung
    • Journal of Technology Innovation
    • /
    • v.25 no.3
    • /
    • pp.1-24
    • /
    • 2017
  • With the rise of internet of things (IoT), there have been several studies to analyze the technological trend and technological convergence. However, previous work have been relied on the qualitative work that investigate the IoT trend and implication for future business. In response, this study considers the patent information as the proxy measure of technology, and conducts a quantitative and analytic approach for analyzing technological convergence using patent co-classification analysis and text mining. First, this study investigate the characteristics of IoT business, and characterize IoT business into four dimensions: device, network, platform, and services. After this process, total 923 patent classes are classified into four types of IoT technology group. Since most of patent classes are classified into device technology, we developed a co-classification network for both device technology and all technologies. Patent keywords are also extracted and these keywords are also classified into four types: device, network, platform, and services. As a result, technologies for several IoT devices such as sensors, healthcare, and energy management are derived as a main convergence group for the device network. For the total IoT network, base network technology plays a key role to characterize technological convergence in the IoT network, mediating the technological convergence in each application area such as smart healthcare, smart home, and smart grid. This work is expected to effectively be utilized in the technology planning of IoT businesses.

Design and Development of Personal Healthcare System Based on IEEE 11073/HL7 Standards Using Smartphone (스마트폰을 이용한 IEEE 11073/HL7 기반의 개인 건강관리 시스템 설계 및 구현)

  • Nam, Jae-Choong;Seo, Won-Kyeong;Bae, Jae-Seung;Cho, You-Ze
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.12B
    • /
    • pp.1556-1564
    • /
    • 2011
  • The increased life expectancy of human due to the advance of medical techniques has led to many social problems such as rapidly aging populations, increased medical expenses and a lack of medical specialists. Thus, studies on improving the quality of life with the least amount of expense have been going on by incorporating advanced technologies, especially for Personal Health Devices (PHDs), into the medical service market. However, compatibility and extensibility among manufacturers of PHDs have not been taken into account in most of the researches done on the development of PHDs because most of them have been supported by individual medical organizations. The interoperability among medical organizations can not be guaranteed because each medical organization uses different format of the messages. Therefore, in this paper, an expansion module that can enable commercially-available non-standard PHDs to support the IEEE 11073, and a smart-phone-based manager that can support easy and comprehensive management on receiving and transmitting the collected data from each PHD using IEEE 11073 standard were developed. In addition, a u-health system that can transmit the data collected in the manager using the standard data format HL 7 to medical center for real-time medical service from every medical institutions that support this standard was designed and developed.

Manchester coding of compressed binary clusters for reducing IoT healthcare device's digital data transfer time (IoT기반 헬스케어 의료기기의 디지털 데이터 전송시간 감소를 위한 압축 바이너리 클러스터의 맨체스터 코딩 전송)

  • Kim, Jung-Hoon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.6
    • /
    • pp.460-469
    • /
    • 2015
  • This study's aim is for reducing big data transfer time of IoT healthcare devices by modulating digital bits into Manchester code including zero-voltage idle as information for secondary compressed binary cluster's compartment after two step compression of compressing binary data into primary and secondary binary compressed clusters for each binary clusters having compression benefit of 1 bit or 2 bits. Also this study proposed that as department information of compressed binary clusters, inserting idle signal into Manchester code will have benefit of reducing transfer time in case of compressing binary cluster into secondary compressed binary cluster by 2 bits, because in spite of cost of 1 clock idle, another 1 bit benefit can play a role of reducing 1 clock transfer time. Idle signal is also never consecutive because the signal is for compartment information between two adjacent secondary compressed binary cluster. Voltage transition on basic rule of Manchester code is remaining while inserting idle signal, so DC balance can be guaranteed. This study's simulation result said that even compressed binary data by another compression algorithms could be transferred faster by as much as about 12.6 percents if using this method.

Development of Authentication Service Model Based Context-Awareness for Accessing Patient's Medical Information (환자 의료정보 접근을 위한 상황인식 기반의 인증서비스 모델 개발)

  • Ham, Gyu-Sung;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.22 no.1
    • /
    • pp.99-107
    • /
    • 2021
  • With the recent establishment of a ubiquitous-based medical and healthcare environment, the medical information system for obtaining situation information from various sensors is increasing. In the medical information system environment based on context-awareness, the patient situation can be determined as normal or emergency using situational information. In addition, medical staff can easily access patient information after simple user authentication using ID and Password through applications on smart devices. However, these services of authentication and patient information access are staff-oriented systems and do not fully consider the ubiquitous-based healthcare information system environment. In this paper, we present a authentication service model based context-awareness system for providing situational information-driven authentication services to users who access medical information, and implemented proposed system. The authentication service model based context-awareness system is a service that recognizes patient situations through sensors and the authentication and authorization of medical staff proceed differently according to patient situations. It was implemented using wearables, biometric data measurement modules, camera sensors, etc. to configure various situational information measurement environments. If the patient situation was emergency situation, the medical information server sent an emergency message to the smart device of the medical staff, and the medical staff that received the emergency message tried to authenticate using the application of the smart device to access the patient information. Once all authentication was completed, medical staff will be given access to high-level medical information and can even checked patient medical information that could not be seen under normal situation. The authentication service model based context-awareness system not only fully considered the ubiquitous medical information system environment, but also enhanced patient-centered systematic security and access transparency.

A Secure and Lightweight Authentication Scheme for Ambient Assisted Living Systems (전천 후 생활보조 시스템을 위한 안전하고 경량화 된 인증기법)

  • Yi, Myung-Kyu;Choi, Hyunchul;Whangbo, Taeg-Keun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.4
    • /
    • pp.77-83
    • /
    • 2019
  • With the increase in population, the number of such senior citizens is increasing day by day. These senior citizens have a variety of care needs, but there are not enough health workers to look after them. Ambient Assisted Living (AAL) aims at ensuring the safety and health quality of the older adults and extending the number of years the senior citizens can live independently in an environment of their own preference. AAL provides a system comprising of smart devices, medical sensors, wireless networks, computer and software applications for healthcare monitoring. AAL can be used for various purposes like preventing, curing, and improving wellness and health conditions of older adults. While information security and privacy are critical to providing assurance that users of AAL systems are protected, few studies take into account this feature. In this paper, we propose a secure and lightweight authentication scheme for the AAL systems. The proposed authentication scheme not only supports several important security requirements needed by the AAL systems, but can also withstand various types of attacks. Also, the security analysis results are presented to show the proposed authentication scheme is more secure and efficient rather than existing authentication schemes.

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Self-Organizing Middleware Platform Based on Overlay Network for Real-Time Transmission of Mobile Patients Vital Signal Stream (이동 환자 생체신호의 실시간 전달을 위한 오버레이 네트워크 기반 자율군집형 미들웨어 플랫폼)

  • Kang, Ho-Young;Jeong, Seol-Young;Ahn, Cheol-Soo;Park, Yu-Jin;Kang, Soon-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.7
    • /
    • pp.630-642
    • /
    • 2013
  • To transmit vital signal stream of mobile patients remotely, it requires mobility of patient and watcher, sensing function of patient's abnormal symptom and self-organizing service binding of related computing resources. In the existing relative researches, the vital signal stream is transmitted as a centralized approach which exposure the single point of failure itself and incur data traffic to central server although it is localized service. Self-organizing middleware platform based on heterogenous overlay network is a middleware platform which can transmit real-time data from sensor device(including vital signal measure devices) to Smartphone, TV, PC and external system through overlay network applied self-organizing mechanism. It can transmit and save vital signal stream from sensor device autonomically without arbitration of management server and several receiving devices can simultaneously receive and display through interaction of nodes in real-time.