DOI QR코드

DOI QR Code

Manchester coding of compressed binary clusters for reducing IoT healthcare device's digital data transfer time

IoT기반 헬스케어 의료기기의 디지털 데이터 전송시간 감소를 위한 압축 바이너리 클러스터의 맨체스터 코딩 전송

  • Kim, Jung-Hoon (Division of Public Health, Seoul National University)
  • Received : 2015.11.26
  • Accepted : 2015.12.13
  • Published : 2015.12.30

Abstract

This study's aim is for reducing big data transfer time of IoT healthcare devices by modulating digital bits into Manchester code including zero-voltage idle as information for secondary compressed binary cluster's compartment after two step compression of compressing binary data into primary and secondary binary compressed clusters for each binary clusters having compression benefit of 1 bit or 2 bits. Also this study proposed that as department information of compressed binary clusters, inserting idle signal into Manchester code will have benefit of reducing transfer time in case of compressing binary cluster into secondary compressed binary cluster by 2 bits, because in spite of cost of 1 clock idle, another 1 bit benefit can play a role of reducing 1 clock transfer time. Idle signal is also never consecutive because the signal is for compartment information between two adjacent secondary compressed binary cluster. Voltage transition on basic rule of Manchester code is remaining while inserting idle signal, so DC balance can be guaranteed. This study's simulation result said that even compressed binary data by another compression algorithms could be transferred faster by as much as about 12.6 percents if using this method.

본 연구는 IoT 기술을 이용한 의료기기에서 송수신되는 대량의 이진데이터의 디지털 변조 과정시 독특한 압축 알고리즘을 적용하여 보다 빠른 시간내에 데이터를 송수신하기 위한 연구이다. 이를 위해 이진데이터 스트리밍을 간단한 규칙에 따라 바이너리 클러스터라는 단위로 구분한 뒤, 각 바이너리 클러스터에 대해 1차 압축바이너리 클러스터를 생성하고 유형별로 추가적인 압축 연산을 통해 1 내지 2비트를 압축한 2차 압축 바이너리 클러스터를 생성한 뒤, 각각의 2차 압축 바이너리 클러스터를 맨체스터 라인코딩 방식으로 전송하였다. 특히 본 연구에서는 각각의 2차 압축바이너리 클러스터들의 구분을 위한 정보로서 휴지 전위를 2차 압축 바이너리 클러스터를 코딩한 맨체스터 코드 사이에 삽입 전송하는 방법을 제안하였다. 이를 통해, 2비트 압축된 바이너리 클러스터의 경우 휴지 전위를 위한 1 전송 단위 시간의 소요를 고려하더라도 추가적으로 1 전송 단위 시간의 시간적 이득을 얻게 됨으로써 전송 속도를 향상시킬 수 있을 것으로 기대되었다. 휴지 전위는 1개 전송 단위로서만 독립적으로 각각 분리된 압축바이너리 클러스터들의 연결에 사용하므로, 2개 전송단위 시간 이상의 연속된 휴지 전위는 존재하지 않게 되고, 맨체스터 코딩의 기본 규칙을 준수하므로 직류 성분도 존재하지 않게 된다. 특히 이미 정보이론 알고리즘을 이용한 압축된 이진 데이터에 대해서도 본 연구에서 제안한 압축전송 과정을 이용할 경우 전송 속도를 추가적으로 약 12.6% 향상 시킬 수 있음이 예측되었다.

Keywords

References

  1. Forster, R., "Manchester encoding: Opposing definitions resolved". Engineering Science & Education Journal, 9 (6), p. 278, 2000 https://doi.org/10.1049/esej:20000609
  2. Namil Yun, Communication Theory, p. 264, Life and Power press , p. 264, 2015
  3. Atmel Corporation , "Manchester Coding Basics Application Note", pp.4-8, 2009
  4. Sang Jo Park, "Threshold Level Setting of a Receiver in Optical Subscriber Network with Manchester Coded Downstream and NRZ Upstream Re-modulation for the Improvement of Upstream Data Ratios", Journal of the Korea society of computer and information, 16 (12), p. 176, 2011
  5. Young Sun OH, Han Jong Kim, Chang Eon Kang, "Design of the Efficient Clock Recovery Circuit in the Communication Systems using the Manchester Encoding Scheme", The journal of the Korean institute of communication science ,16 (10), pp. 1001-1008, 1991
  6. HYUNDAI MICRO ELECTRONICS CO.,LTD., "The decoding apparatus of the Manchester code", Korea Registered Patent No. 1001579230000, 1995
  7. Ji-Hun Yun, Yong-Kab Kim,"A Study on Short-Range Wireless Communication System Development Using LED Based on Power Line Communication", Journal of Korea Institute of Information, Electronics, and Communication Technology, 3(1) pp. 19-23, 2010
  8. Jung Hyun Lee, "Wireless transmission method for VGA capsule endoscopy using manchester encoding", pp. 56-68, Department of Electronics Graduate School, Kyungpook National University Daegu, Korea, 2008
  9. J. Zhang, N. Chi, P. V. Holm-Nielsen, C. Peucheret, and P. Jeppesen, "Method for high-speed Manchester encoded optical signal generation," in Optical Fiber Communication Conference, Technical Digest (CD) (Optical Society of America, 2004), paper MF76.
  10. Sun Park, Chul Won Kim , "A Design for Medical Information System of Emergency Situation Prediction using Body Signal", Journal of Korea Institute of Information, Electronics, and Communication Technology, 3(4) pp. 28-34, 2010
  11. Jung Hoon Kim, "Binary data compression and decompression apparatus and method thereof", Korea Registered Patent No. 1014676840000, 2013

Cited by

  1. Development of Mobility and Vitality Signal Monitoring System Based on ZigBee-PSTN Gateway for the Elderly vol.9, pp.1, 2016, https://doi.org/10.17661/jkiiect.2016.9.1.009
  2. IoT 및 금융 거래 실시간 데이터 정보의 압축 전송을 위한 새로운 고효율 유니버설 코드(BL-beta) 제안 vol.11, pp.4, 2018, https://doi.org/10.17661/jkiiect.2018.11.4.421