• Title/Summary/Keyword: Health Measurement

Search Result 3,541, Processing Time 0.035 seconds

Ttrosine Hydroxylase in Japanese Medaka (Oryzias latipes): cDNA Cloning and Molecular Monitoring of TH Gene Expression As a Biomarker (송사리 Tyrosine Hydroxylase: cDNA 클로닝 및 생물지표로서의 TH 유전자 발현의 분자생물학적 추적)

  • Shin, Sung-Woo;Kim, Jung-Sang;Chon, Tae-Soo;Lee, Sung-Kyu;Koh, Sung-Cheol
    • Environmental Analysis Health and Toxicology
    • /
    • v.15 no.4
    • /
    • pp.131-137
    • /
    • 2000
  • The release of hazardous waste materials into the environment poses serious risks in humans and ecosystems. The risk assessment of environmental pollutants including hazardous chemicals requires a comprehensive measurement of hazard and exposure of the chemicals that can be achieved by toxicity evaluation using a biological system such as biomarkers. In this report we have tried to develop a biomarker used to elucidate a molecular basis of, and to monitor abnormal behaviors caused by diazinon in Japanese medaka (Oryzias latipes) as a model organism. First, an attempt was made to clone tyrosine hydroxylase gene from Japanese medaka that would be a candidate for a biomarker for neuronal modulations and behaviors. For monitoring experiments at behavioral and molecular biological levels, the fish were treated under different sublethal conditions of diazinon and their behavioral responses were observed . In this study we have successfully cloned a partial TH gene from the medaka fish through PCR screening of an ovary cDNA library. DNA sequencing analysis revealed that the amplified fragment was 327 bp encoding 109 amino acids. Comparing the DNA sequence of medaka TH with other species, TH gene revealed the DNA sequence was completely identical to that of rat TH. In the RT-PCR, 330 Up of mRNA was consistently amplified in all the treated samples including control There were no significant differences in the TH expression level regardless of treating concentrations (1∼5,000 ppb) and time (0∼48 hr) The reason appeared to be that RT-PCR was not performed using through a quantitative analysis normalized against an actin gene expression. Organ or tissue - specific detection of TH activity and mRNA as biomarkers will be a useful monitoring tool for neurobehavioral changes in fish influenced by toxic chemicals. Furthermore, quantitative analysis of locomotive patterns and its correlation with the neurochemical and molecular data would be highly useful in measuring toxicity and hazard ofvarious environmental pollutants.

  • PDF

Exposure and Risk Assessment for Operator Exposure to Insecticide Acetamiprid during Water Melon Cultivation in Greenhouse using Whole Body Dosimetry (수박 시설재배에서 살충제 Acetamiprid 사용 시 전신노출법에 의한 농작업자의 노출 및 위해성평가)

  • Kim, Eunhye;Lee, Jiho;Sung, Jeonghee;Lee, Jonghwa;Shin, Yongho;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.247-257
    • /
    • 2014
  • Assessment for operator's dermal and inhalation exposure to acetamiprid during cultivation of water melon in greenhouse was carried out. For dermal exposure measurement, whole body dosimetry (WBD) was performed as the first trial in Korea. WBD consists of cotton/polyester outer clothes and cotton inner clothes. Hand exposure was measured by washing of nitrile gloves and hands while head exposure was monitored by face/neck wipe technique. Inhalation exposure was monitored with personal air sampling pumps and IOM sampler (glass fiber filter). Analytical limit of quantitation was 2.5 ng/mL. Good reproducibility (C.V < 8.7%), linearity ($R^2$ > 0.99) and recovery (70~119%) were obtained. Field recovery of acetamiprid was 77~95%. During mixing/loading, hand exposure of acetamiprid was about 10 times ($229.7{\mu}g$) more than that of application case ($20.9{\mu}g$). During application, total dermal exposure was $1207.4{\mu}g$. Exposure of lower legs was $1132.1{\mu}g$, which is 93.8% of the total dermal exposure. Inhalation exposure during mixing/loading and application was not detected. Margin of safety (MOS) was calculated for risk assessment using male Korean average body weight (70 kg) and acceptable operator exposure level ($124{\mu}g/kg/day$) to give 140, suggesting that health risk of operator during treatment of acetamiprid for water melon in greenhouse could be safe.

Visual fatigue in Watching 3 Dimension Television (3D TV 시청에 있어서 시청 피로)

  • Yoon, Jeong Ho;Lee, Ikhan;Kim, Taehyun;Kim, Jae-Do
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.47-52
    • /
    • 2012
  • Purpose: This study was to evaluate visual fatigue with passing of watching 3D TV in short term and with experience of watching 3DTV in long term. Methods: 98 adult subjects aged $33.5{\pm}5.5$ years (22 to 51 years; 12 females and 86 males) agreed to participate in this study. Subjects were asked to watch 52 inch LED 2D and 3D television (Shutter glasses method) at 2.7 meters for 65minutes with wearing their habitual glasses or contact lenses. For evaluating visual fatigue, subjects were verbally responded to 11 questions : eye straining, eye paining, dry eye, sore eye, watery eye, photophobia, blur vision, diplopia, eye fatigue, headache, and dizziness with scale 0 to 3 at each measurement while watching 3D and 2D TV. Results: The mean scores of visual fatigue were $2.08{\pm}2.14$, $3.19{\pm}3.02$, $3.40{\pm}3.37$, $3.53{\pm}3.07 $for after 5 minutes, 25 minutes, 45 minutes, and 65 minutes respectively for 3D TV, and $0.40{\pm}1.03$, $0.22{\pm}0.70$, $0.22{\pm}0.58$, and $0.17{\pm}0.52$ after 25, 45, and 65 minutes respectively for 2D TV. Visual fatigue for watching 3D TV was significantly higher than for watching 2D TV at all measurements sessions (paired t-test, p < 0.001). The visual fatigue significantly increased during watching 3D TV for 65 minutes (p < 0.001, RM-ANOVA). The visual fatigue during watching 3D TV was significantly increased until 25 minutes (paired t-test, p < 0.001), stable after that. For correlation between visual fatigue and 3D watching experience, the more 3D watching experiences were significantly the less visual fatigues in photophobia, blur vision, diplopic and dizzy symptoms (ANOVA, all F(1, 96) = 4.500, all p < 0.05), but there was not significantly different in the other symptoms (ANOVA, F (1, 96) = 2.123, p = 0.148). Conclusions: Visual fatigue for watching 3D TV was higher than for watching 2D TV, increase by 25 minutes. It was different by symptoms for correlation between visual fatigue and 3D watching experience.

The effects of Moxibustion Therapy on Chronic Low Back Pain, Daily Living Disability and Sleep Pattern in Elderly Women (뜸요법이 여성노인의 만성요통, 일상생활기능장애 및 수면양상에 미치는 효과)

  • Kim, Hye-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.301-310
    • /
    • 2016
  • This is a nonequivalent control group non-synchronized experiment research to verify the effect of moxibustion therapy on efficient management of daily living disabilities and sleep patterns in elderly women with chronic low back pain. Total 12 sessions of moxibustion therapy were applied to elderly women(30 subjects in an experimental group and 30 subjects in a control group) in G City once a week for 12 weeks from March 15th to May $31^{st}$ 2015. Then the follow-up study was conducted 2 weeks after the post survey. For moxibustion, was applied to Shen-shu, Ashi point, Ta chang shu, Yang kuan and Yosu. 5 sheets of moxibustion were applied to 7 acupuncture points of Mugeukboyang moxibustion; Zu san li & Chu chi, Chung wan, Chung chi & Shui tao, Fei shu, Kao hung and Tien shu, Wijung respectively and experimental treatment was conducted. For assessing the degree of back pain, Visual Analog Scale(VAS) developed by Scott & Huskisson(1979) was used and for measuring the degree of daily living disability, Oswestry Disability Index, which was developed by Fairbank et al(1980) and translated and revised by Yim, Hyeon-sul et al.(1998), was used. For measuring sleep patterns, the sleep pattern measurement tool developed by Oh, Jin-su, Song, Mi-soon and Kim, Sin-mi(1998) was used. For data analysis, SPSS/WIN 18.0 was employed and Chi-square test, t-test and repeated measures ANOVA were performed. There were significant differences in pain score(F=2510.32, p<.001), daily living disability score(F=1937.82, p<.001) and sleep pattern score((F=15.54, p<.001) of elderly women that were provided with moxibustion therapy, compared to the control group. Therefore, it was found that moxibustion therapy made a positive contribution to reduction in pain and daily living disabilities and improvement in sleep quality. Based on this study finding, there is a need to apply moxibustion therapy to elderly people with chronic low back pain as a nursing intervention in future.

Analysis of the Dose Distribution of Moving Organ using a Moving Phantom System (구동팬텀 시스템에 의한 움직이는 장기의 선량분포 분석)

  • Kim, Yon-Lae;Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Lee, Gui-Won;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purpose: Few researches have been peformed on the dose distribution of the moving organ for radiotherapy so far. In order to simulate the organ motion caused by respiratory function, multipurpose phantom and moving device was used and dosimetric measurements for dose distribution of the moving organs were conducted in this study. The purpose of our study was to evaluate how dose distributions are changed due to respiratory motion. Materials and Methods: A multipurpose phantom and a moving device were developed for the measurement of the dose distribution of the moving organ due to respiratory function. Acryl chosen design of the phantom was considered the most obvious choice for phantom material. For construction of the phantom, we used acryl and cork with density of $1.14g/cm^3,\;0.32g/cm^3$ respectively. Acryl and cork slab in the phantom were used to simulate the normal organ and lung respectively. The moving phantom system was composed of moving device, moving control system, and acryl and cork phantom. Gafchromic film and EDR2 film were used to measure dose ditrbutions. The moving device system may be driven by two directional step motors and able to perform 2 dimensional movements (x, z axis), but only 1 dimensional movement(z axis) was used for this study. Results: Larger penumbra was shown in the cork phantom than in the acryl phantom. The dose profile and isodose curve of Gafchromic EBT film were not uniform since the film has small optical density responding to the dose. As the organ motion was increased, the blurrings in penumbra, flatness, and symmetry were increased. Most of measurements of dose distrbutions, Gafchromic EBT film has poor flatness and symmetry than EDR2 film, but both penumbra distributions were more or less comparable. Conclusion: The Gafchromic EBT film is more useful as it does not need development and more radiation dose could be exposed than EDR2 film without losing film characteristics. But as response of the optical density of Gafchromic EBT film to dose is low, beam profiles have more fluctuation at Gafchromic EBT. If the multipurpose phantom and moving device are used for treatment Q.A, and its corrections are made, treatment quality should be improved for the moving organs.

  • PDF

Temperature Compensation of Optical FBG Sensors Embedded Tendon for Long-term Monitoring of Tension Force of Ground Anchor (광섬유 센서 내장형 텐던을 이용한 그라운드 앵커의 장기 장력모니터링을 위한 온도보상)

  • Sung, Hyun-Jong;Kim, Young-Sang;Kim, Jae-Min;Park, Gui-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.5
    • /
    • pp.13-25
    • /
    • 2012
  • Ground anchor method is one of the most popular reinforcing technology for slope in Korea. For the health monitoring of slope which is reinforced by permanent anchor for a long period, monitoring of the tension force of ground anchor is very important. However, since electromechanical sensors such as strain gauge and V/W type load cell are also subject to long-term risk as well as suffering from noise during long distance transmission and immunity to electromagnetic interference (EMI), optical FBG sensors embedded tendon was developed to measure strain of 7-wire strand by embedding FBG sensor into the center king cable of 7-wire strand. This FBG sensors embedded tendon has been successfully applied to measuring the short-term anchor force. But to adopt this tendon to long-term monitoring, temperature compensation of the FBG sensors embedded tendon should be done. In this paper, we described how to compensate the effect in compliance with the change of underground temperature during long-term tension force monitoring of ground anchors by using optical fiber sensors (FBG: Fiber Bragg Grating). The model test was carried out to determine the temperature sensitivity coefficient (${\beta}^{\prime}$) of FBG sensors embedded tendon. The determined temperature sensitivity coefficient ${\beta}^{\prime}=2.0{\times}10^{-5}/^{\circ}C$ was verified by comparing the ground temperatures predicted from the proposed sensor using ${\beta}^{\prime}$ with ground temperatures measured from ground thermometer. Finally, temperature compensations were carried out based on ${\beta}^{\prime}$ value and ground temperature measurement from KMA for the tension force monitoring results of tension type and compression type anchors, which had been installed more than 1 year before at the test site. Temperature compensated tension forces are compared with those measured from conventional load cell during the same measuring time. Test results show that determined temperature sensitivity coefficient (${\beta}^{\prime}$) of FBG sensors embedded tendon is valid and proposed temperature compensation method is also appropriate from the fact that the temperature compensated tension forces are not dependent on the change of ground temperature and are consistent with the tension forces measured from the conventional load cell.

Calculation of Derived Investigation Levels for Uranium Intake (우라늄 섭취의 유도조사준위 산출)

  • Lee, Na-Rae;Han, Seung-Jae;Cho, Kun-Woo;Jeong, Kyu-Hwan;Lee, Dong-Myung
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.68-77
    • /
    • 2013
  • Derived Investigation levels(DILs) were calculated to protect the workers from the effects of both radiological hazard and chemical toxicity by uranium intake. Investigation Levels(ILs) of committed effective dose of 2 mSv $y^{-1}-6$ mSv $y^{-1}$ and uranium concentration of 0.3 ${\mu}g$ $g^{-1}$ in kidney, based on Korean Nuclaer Safety Act, Korean Occupational Safety and Health Act and current scientific studies of uranium intake were assumed. DILs of radiological hazard and chemical toxicity were then calculated based on the concentration of uranium in air of workplace, the lung monitoring and urine analysis, respectively. As a result, in case of the nuclear fuel fabrication plant where 3.5% enriched uranium is handled, derived investigation level(DIL) for the control of the concentration of uranium in the air of workplace assumed with 15-min acute inhalation was 0.6 mg $m^{-3}$ for all types of uranium. DILs for the control of the average concentration of uranium in air of workplace, assuming an 8-hour workday, were 15.21 ${\mu}g$ $m^{-3}$ of Type F uranium, 0.41-1.23 Bq $m^{-3}$ and 0.13-0.39 Bq $m^{-3}$ for Type M and Type S uranium, respectively. DILs for the lung monitoring assumed with a period of 6-month interval were 0.37-1.11 Bq and 0.39-1.17 Bq in acute and chronic inhalation for Type M, respectively and 0.30- 0.91 Bq and 0.19-0.57 Bq in acute and chronic inhalation for Type S, respectively. Since a detection limit of typical germanium detector for the measurement of 235U activity is 4 Bq, DILs calculated for the lung monitoring were not appropriate. DILs for urine analysis, for which an interval was assumed to be 1 month, were 14.57 ${\mu}g$ $L^{-1}$ based on chemical toxicity after acute inhalation. In addition, acute and chronic inhalation of Type M were calculated 2.85-8.58 ${\mu}g$ $L^{-1}$ and 1.09-3.27 ${\mu}g$ $L^{-1}$ based on the radiological hazard, respectively.

Midwives' Perceptions of the Importance of Teaching the Lamaze Method of Childbirth Preparation, Their Practice of it and Inhibiting Factors. (조산사의 라마즈 산전교육에 대한 중요성 인식과 수행정도 및 저해요인에 관한 연구)

  • Yoon, Gui-Nam;Cho, Mi-Young
    • 모자간호학회지
    • /
    • v.2 no.1
    • /
    • pp.21-33
    • /
    • 1992
  • This study was done to investigate how importantly midwives thought of Lamaze Method of Childbirth, how satisfactorily they performed their Lamaze Method of Childbirth and what inhibited their activities from being performed if not done satisfactorily. The subjects of this study were 76midwives at midwifery in Pusan, Deagu, Kyungnam and Kyungbok. Data were collected by using questionaire from Sep. 1 to Sep.30, 1991. The measurement tools was maded by the researcher based on Kim's scale for prenatal nursing activities. The statistical analysis was done with based statistical values likes frequencies, means, standard deviations and advanced methods such as Pearson's correlation coefficient, 1-test, F-test, F-test by using SPSS package program. The results of this study can be summarized as follows ; 1. The results of Investigating perception according to importance degree and performance degree of Lamaze Method of Childbring showed that midwives were slightly below both perception according to importance(2.17) and performance(2.16) of Lamaze Method of Childbirth 2. Inhibiting factors of Lamaze Method of Childbirth were abscence of husband(3.08), lack of teaching room(2.71), and lack of books or literature of Lamaze Method (2.58). 3. There appears to be a positive relation between perception according to importance degree and performance degree of Lamaze Method of Childbirth (r=0.69, P<0.01). There appears to be a negative relation between perception according to importance degree and inhibit factors of performance (r=-0.38, P<0.01). There appears to be a negative relation between performance and inhibit factors of performance (r=-0.22. P<0.01). 4. The item of highest perception defree in prenatal education is 1st, Consultation about sexual life (2.53), End, illustration of the importance of a bath and perinal cleanliness and Avoidance of excessive respiration method and also its comfortable application during uterine contractility(2.45). The item of lowest perception degree is about pregnant symptom sign and predicted date of birth (E.D.C.). On the other hand, The item of highest performance degree is education about nurtrition during pregnacy. 2nd, Illustration of the Importance of a bath and perineal cleanness(2.45). The lowest one is leaching the pregnant woman and her family about the role of husband and her family and also teaching the couple to learn exercise and respiration method (1.84). Though importance perception degree and performance degree is low. Midwives who wert subject in this research shoves that they perform general items concerning prenatal education well. 5. In the relationship between perception according to importance degree of Lamaze Method of Childbirth and the general characteristics of subjects, the differences in mean number of visiting pregnacies for 1 month. 6. In the relationship between performance degree of Lamaze Method of Childbirth and the general characteristics of subjects, the differences in age, marriage, and mean number of visiting pregnancies for 1 month. With the above information we see the importance of midwife prenatal care education and high correlation between performance degree and perception degree. When Lamaze prenatal education is well performed the number of pregnant woman who have follow-up, check-ups increase. Therefore in this research we can validity that there is a relation between Lamaze prenatal education and patient follow-up. This research showes in a situation where if one does not maximally perform a prenatal education there is a possibility that the popular use of midwife activities may encounter obstacles so the education to save new knowledge and training for prenatal education is needed as a function of Lamaze prenatal education, when a special Lamaze education is well performed for the pregnant woman, who follows-up at amidwife clinic. With the above conclusion we can suggest : 1. Continued research which minimized obstacles to Lamaze prenatal education is needed. 2. The official method of midwives is necessary.

  • PDF

C-Reactive Protein in Pregnancy and Labor (임신주령과 진통에 따른 임부 혈청 C-Reactive Protein의 동태)

  • Kim, Jong-Ho;Kim, Byung-Suk;Lee, Jae-Yul;Lee, Young-Gi;Lee, Tae-Hyung;Lee, Seung-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.2
    • /
    • pp.298-305
    • /
    • 1993
  • In order to evaluate the clinical usefulness of maternal serum C-reactive protein measurement in early detection of infectious morbidity at term laboring women, serum C-reactive protein levels were measured in 521 healthy pregnant women ; 64 who were not in labor before term, 55 who were in labor before term, 71 who were not in labor at term and 331 who were in labor at term. The frequencies of elevated serum C-reactive protein level were compared in relation to the gestational weeks, the presence or absence of labor, the status of amniotic membranes and the degree of cervical dilation. The obtained results were as follows. 1. The frequencies of women with elevated serum C-reactive protein, 0.8mg/dl or higher and 2.0mg/dl or higher, in 521 health pregnant women were 12% and 4%, respectively. 2. C-reactive pretein levels of 0.8mg/dl or higher were more frequent in the group of women in labor than those not in labor(5.93%, vs. 13.73%, p<0.05), but the frequencies of C-reactive protein level of 2.0mg/dl or higher were not statistically different between both groups. The frequencies of C-reactive protein level of 0.8mg/dl or higher and 2.0mg/dl or higher were not statistically different between the groups before term and at term, intact and ruptured membranes, latent phase and active phase of labor, respectively. 3. Before term, C-reactive protein levels of 0.8mg/dl or higher and 2.0mg/dl or higher were more frequent in the group of women in labor than those not in labor(23.64 vs. 4.69, p<0.001 and 12.73% vs. 3.13%, p<0.05, respectively), but those statistical differences were not seen between both group at term. Above results and review of literature suggest that serum C-reactive protein level of 2.0mg/dl or higher may be reliable in early detection of infectious morbidity at term laboring women as well as laboring women before term, and the presence of subclinical infection should be suspected in the laboring women before term with serum C-reactive protein level of 0.8mg/dl or higher.

  • PDF

Evaluation of TOF MR Angiography and Imaging for the Half Scan Factor of Cerebral Artery (유속신호증강효과의 자기공명혈관조영술을 이용한 뇌혈관검사에서 Half Scan Factor 적용한 영상 평가)

  • Choi, Young Jae;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.92-98
    • /
    • 2016
  • To aim of this study was to assess the full scan and half scan of imaging with half scan factor. Patients without a cerebral vascular disease (n = 30) and were subject to the full scan half scan, and set a region of interest in the cerebral artery from the three regions (C1, C2, C3) in the range of 7 to 8 mm. MIP (maximum intensity projection) to reconstruct the images in signal strength SNR (signal to noise ration), PSNR (peak signal noise to ratio), RMSE (root mean square error), MAE (mean absolute error) and calculated by paired t-test for use by statistics were analyzed. Scan time was half scan (4 minutes 53 seconds), the full scan (6 minutes 04 seconds). The mean measurement range (7.21 mm) of all the ROI in the brain blood vessel, was the SNR of the first C1 is completely scanned (58.66 dB), half-scan (62.10 dB), a positive correlation ($r^2=0.503$), for the second C2 SNR is completely scanned (70.30 dB), half-scan (74.67 dB) the amount of correlation ($r^2=0.575$), third C3 of a complete scan SNR (70.33 dB), half scan SNR (74.64 dB) in the amount of correlation between the It was analyzed with ($r^2=0.523$). Comparative full scan with half of SNR ($4.75{\pm}0.26dB$), PSNR ($21.87{\pm}0.28dB$), RMSE ($48.88{\pm}1.61$), was calculated as MAE ($25.56{\pm}2.2$). SNR is also applied to examine the half-scans are not many differences in the quality of the two scan methods were not statistically significant in the scan (p-value > .05) image takes less time than a full scan was used.