• Title/Summary/Keyword: Head rotation

Search Result 342, Processing Time 0.022 seconds

Correction of positional change of frontal cephalometric landmarks caused by vertical head rotation (두부의 수직회전 시 정모두부방사선사진상의 계측점 변화와 이의 보정)

  • Kim, Mi-Young;Lee, Kyung-Min;Cho, Jin-Hyoung;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.98-111
    • /
    • 2011
  • Objective: Superimposition of frontal cephalograms cannot be performed when the cephalograms are taken with different vertical head rotations. The purpose of the present study was to evaluate the validity of correcting the positional change of frontal cephalometric landmarks caused by vertical head rotation. Methods: In 30 adult individuals, frontal and lateral cephalograms were taken at a $90^{\circ}$ angle. Geometric principles of radiography were used to calculate the possible vertical and horizontal landmark changes if the head should be rotated down $5^{\circ}$ about an ear rod axis. The calculated changes were then compared with cephalometric changes measured on frontal cephalogram actually taken with the head rotated down $5^{\circ}$. Results: When the frontal cephalograms were taken with the head rotated down $5^{\circ}$ about an ear rod axis, significant changes in the vertical position of the landmarks occurred, particularly in the landmarks located farther anteriorly from the ear rod axis. The comparison of calculated changes and real cephalometric changes showed that the differences were less than 0.4 mm in the vertical direction and less than 0.2 mm in the horizontal direction. The differences between calculated and real changes were smaller in the landmarks less affected by vertical head rotation. Conclusions: Even when frontal cephalograms are taken at different vertical head rotations, the concomitant changes in the position of the landmarks can be corrected through calculation using the geometric principle of radiography as long as frontal and lateral cephalograms are taken perpendicular to each other.

The Characteristics of High-speed Noncircular Machining Tool Feed Systme using Linear Motor (리니어 모터를 이용한 고속비진원 가공용 공구이송장치의 특성연구)

  • 서준호;민승환;김성식;이선규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.985-990
    • /
    • 1995
  • Recently, the development of high speed and high precision NC-lathe for piston head machining is needed for the complexity and diversity of the piston head shape used in automobile reciprocating engine. THe piston head has many complex shapes in the aspect of fuel economy, such as ovality, profile, double ovality and recess. Among them, for the maching of the over shape of 0.1~1mm the cutting tool should move periodically symchronized with the rotation of piston workpiece. The cutting tool feeed system must have high positioning accuracy for the precise machining, high speed for the fast maching and high dynamic stiffness for the cutting force. The linear brushless DC motor is used for satisfying these coditions. The ballbush guide and supporting guide using turcite is used for the guidance of the feed drive system. Linear encoder, digital servo ampllifer and controller are used for driving the motor. THis paper presents the design and simulation of the new tool feed system for noncircular machining.

  • PDF

PANORAMIC IMAGE OF MANDIBULAR CONDYLE ACCORDING TO HEAD POSITION (두부 위치에 따른 하악 과두의 파노라마상)

  • Kim Jeong Hwa;Choi Soon Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.219-225
    • /
    • 1990
  • Panoramic radiography is convenient in clinic and visualizes those areas which other technique do not give. But the technique has limitation of image distortion which results from the relationship of the ramus to the focal trough and from the direction of the central ray. This study is, using 7 dry skulls, to determine the effect of rotation of patient's head on reducing those distortion and determine the magnification ratio of images of mandibular condyle in rotated patient head position. The obtained results were as follows: 1. Generally, in panoramic radiography the anterolateral portion of the mandibular condyle was best to be visualized. 2. There are no significant difference between the image readability of anteromedial portion and that of anterocentral portion of the mandibular condyle. 3. Anterolateral portion of the mandibular condyle was better visualized in rotated head position by 20 degree or horizontal condylar inclination than in conventional position or in rotated head position by 10 degree. 4. The magnification ratio of the anteroposterior diameter in the image of mandibular condyle was least in the rotated head position by horizontal inclination of the mandibular condyle and was largest by 20 degree.

  • PDF

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.

In vivo 3D Kinematics of Axis of Rotation in Malunited Monteggia Fracture Dislocation

  • Kim, Eugene;Park, Se-Jin;Jeong, Haw-Jae;Ahn, Jin Whan;Shin, Hun-Kyu;Park, Jai Hyung;Lee, Mi Yeon;Tsuyoshi, Murase;Sumika, Ikemototo;Kazuomi, Sugamoto;Choi, Young-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.25-30
    • /
    • 2014
  • Background: Normal elbow joint kinematics has been widely studied in cadaver, whilst in vivo study, especially of the forearm, is rare. Our study analyses, in vivo, the kinematics of normal forearm and of malunited forearm using a three-dimensional computerized simulation system. Methods: We examined 8 patients with malunited Monteggia fracture and 4 controls with normal elbow joint. The ulna and radius were reconstructed from CT data placing the forearm in three different positions; full pronation, neutral, and full supination using computer bone models. We analyzed the axis of rotation 3-dimentionally based on the axes during forearm rotation from full pronation to full supination. Results: Axis of rotation of normal forearm was pitch line, with a mean range of 2 mm, from full pronation to full supination, connecting the radial head center proximally and ulnar fovea distally. In normal forearm, the mean range was 1.32 mm at the proximal radioulnar joint and 1.51 mm at the distal radioulnar joint. However in Monteggia fracture patients, this range changed to 7.65 mm at proximal and 4.99 mm at distal radoulnar joint. Conclusions: During forearm rotation, the axis of rotation was constant in normal elbow joint but unstable in malunited Monteggia fracture patients as seen with radial head instability. Therefore, consideration should be given not only to correcting deformity but also to restoring AOR by 3D kinematics analysis before surgical treatment of such fractures.

Development of Robust-to-Rotation Iris Feature Extraction Algorithms For Embedded System (임베디드 시스템을 위한 회전에 강인한 홍채특징 추출 알고리즘 개발)

  • Kim, Shik
    • The Journal of Information Technology
    • /
    • v.12 no.4
    • /
    • pp.25-32
    • /
    • 2009
  • Iris recognition is a biometric technology which can identify a person using the iris pattern. It is important for the iris recognition system to extract the feature which is invariant to changes in iris patterns. Those changes can be occurred by the influence of lights, changes in the size of the pupil, and head tilting. This paper is appropriate for the embedded environment using local gradient histogram embedded system using iris feature extraction methods have implement. The proposed method enables high-speed feature extraction and feature comparison because it requires no additional processing to obtain the rotation invariance, and shows comparable performance to the well-known previous methods.

  • PDF

Preparative Isolation of Ginseng Saponin from Panax ginseng Root Using High-speed Countercurrent Chromatography (High-speed countercurrent chromatography를 이용한 인삼 saponin의 대량 분리 농축)

  • Lee, Chang-Ho;Lee, Boo-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.518-521
    • /
    • 2004
  • Ginseng saponin was isolated from panax ginseng root using high-speed countercurrent chromatography (HSCCC). Preliminary studies were performed to optimize physical properties of two-phase solvent system and operating parameters including rotation speed of column, elution mode of mobile phase, and flow rate. Two-phase solvent system for isolation of ginseng saponins was composed of chloroform, water, and methanol as blending solvent. Chloroform-aqueous methanol (4:6) systems with various concentration of methanol in water were evaluated for retention of stationary phase in column. Retention of stationary phase decreased with increasing flow rate in tail-to-head elution mode using upper phase as mobile phase and head-to-tail elution mode using lower phase as mobile phase. Latter mode produced high retention at flow rate of 5 mL/min. Optimum conditions for isolation of saponin were chloroform/methanol/water (40/39/21) solvent system; mobile phase, of lower organic layer, flow rate, of 5 mL/min, head to tail elution mode, rotation speed, of 800 rpm, and sample injection, of $200{\mu}L$, Recovery yield of ginseng saponin from panax ginseng root extract by HSCCC was 63.6%, and the purity of HSCCC fractions was verified by TLC.

A Study on the Validity and Test-retest Reliability of the Measurement of the Head Tilt Angle of the Smart Phone Application 'KPIMT Torticollis Protractor'

  • Seong Hyeok Song;Ji Su Park;Ki Yeon Song;Ki Hyun Baek;Seung Hak Yoo;Ju Sang Kim
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.6
    • /
    • pp.177-184
    • /
    • 2023
  • Purpose: The purpose of this study was to compare the concurrent validity and test-retest reliability of 'KPIMT Torticollis Protractor', a smart phone and I-pad application for convenient range of motion measurement, and 'Image J', an analysis software with high reliability and validity, according to head tilt and active cervical rotation angle. This was done to determine the clinical utility of 'KPIMT Torticollis Protractor'. Methods: Head tilt and active cervical spine rotation angles of 40 children with congenital muscular torticollis were measured using Image J and KPIMT Torticollis Protractor, respectively. The level of concurrent validity and inter-rater and intra-rater reliability between the two measurement methods were analyzed. Results: For forty participants, the concurrent validity between Image J and KPIMT Torticollis Protractor showed very high validity with ICC of ICC 0.977 (0.995-0.999), 0.994 (0.994-0.998), CVME% 0.71-0.72%, SEM% 0.31-0.34%, MDC% 0.86-0.94%. The test-retest intra-rater reliability showed very high reliability ICC 0.911 (0.911-0.966), CVME% 0.71%, SEM% 0.34-0.36%, MDC% 0.81-0.94%. The test-retest inter-rater showed very high reliability ICC 0.936 (0.933-0.957), CVME% 0.70%, SEM% 0.34-0.35%, MDC% 0.81-0.83%. Conclusion: The KPIMT Torticollis Protractor, a smart phone and IPD application, is a highly reliable and valid device for angle measurement in children with congenital myotonia and can be easily used in clinical practice.

The reliability of the nonradiologic measures of thoracic spine rotation in healthy adults

  • Hwang, Donggi;Lee, Ju Hyeong;Moon, Seongyeon;Park, Soon Woo;Woo, Juha;Kim, Cheong
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.2
    • /
    • pp.65-70
    • /
    • 2017
  • Objective: The purpose of this study was to examine the intertester reliability and validity of four nonradiologic measurements of thoracic spine rotation in healthy adults. Design: Descriptive laboratory study. Methods: This study was conducted on 20 male and 20 female university students aged between 19 and 26. To measure thoracic rotation, a goniometer, a bubble inclinometer, a dual inclinometer, and a smartphone application-clinometer were used. The measurement was performed twice for each device and the same measurement was performed by two examiners. The measurements were performed in the lumbar locked position. The arm in the direction of rotation was taken back and placed onto the back of the lumbar region. With right and left trunk rotation, the head was rotated together but remained in the center line so that the axial rotation was maintained. Both examiners performed the measuring procedures and directly handled the measuring instrument. All measurement results were recorded by the recorder. Results: The range of motion (ROM) of thoracic rotation in lumbar locked position for all four devices was 47 degrees. The intra-rater reliability estimates ranged from 0.738 to 0.906 (p<0.05). The inter-rater reliability estimates ranged from 0.736 to 0.853 (p<0.05). The goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer showed high validity (p<0.05). This result indicates that all four devices may be used by the same examiner and by other examiners obtaining follow-up measurement. Conclusions: The use of the goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer for measurements in the lumbar locked posture are reliable and valid nonradiologic measures of thoracic rotational ROM in healthy adults.

Changes of the Kinetic Energy of Putter Head and Ball Movements during the Process of Impact (퍼팅 스트로크의 충돌과정에서 나타난 퍼터헤드와 볼의 운동에너지 변화 분석)

  • Park, Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.2
    • /
    • pp.175-183
    • /
    • 2003
  • The purpose of this study was to analyze the kinetic energy of putter head and ball movements during the process of impact. Highly skilled 5 golfers(less than 1 handicap) participated in this study and the target distance was 3 m. Movements of ball and putter head were recorded with 2 VHS video cameras(60 Hz, 1/500 s shutter speed). Small control object($18.5{\times}18.5{\times}78.5\;cm$) was used in this sdtuldy. Analyzing the process of impact, putter was digitized before 0.0835 s and after 0.0835 s of impact. Ball was digitized 0.1336 s after impact. The results showed that the maximum speed was appeared at Impact and prolonged for a while. Contact point of the club head was within 0.7 cm to the z axis. After contacting the club head, the ball was moved above the ground level(slide) and returned to the ground with sliding and rolling. After contacting the ground, the speed of ball was relied on the surface of the ground. During impact, 70% of kinetic energy of club head has been transferred to the ball.