• Title/Summary/Keyword: Head neck

Search Result 4,584, Processing Time 0.035 seconds

A Clinical Study on Nodular Thyroid Disease (결절성 갑상선 질환에 대한 임상적 고찰)

  • Lee Gyu-Joon;Park Soon-Tae;Ha Woo-Song;Kwon Soo-In;Choi Sang-Kyeon;Hong Soon-Chan;Lee Young-Joon;Lee Young-Jae
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.2
    • /
    • pp.244-252
    • /
    • 1998
  • The thyroid nodules are the most common endocrine disease requiring surgical management. We perfomed a clinical study of 298 cases with thyroid nodules, who were admitted to and operated at the Department of Surgery, College of Medicine, Gyeong sang National University from January 1987 to April 1997 and the results were summarized as follows: 1) Patients were composed of 214 cases(71.8%) of benign nodule and 84 cases(28.2%) of malignant nodule. Benign and malignant nodules were prevalent in fifth decade. 2) The sex distribution showed a preponderance of females with ratio of 5.88:1 in benign nodule and 11:1 in malignant nodule. 3) The nodules were located in the right lobe(134 cases, 44.9%), the left lobe(121 cases, 40.6%), both lobes(34 cases, 11.4%), and isthmus(8 cases, 2.7%). The possibility of malignancy was higher in the solid rather than cystic lesions. 4) Radioactive iodine scintiscans were perfomed in 273 cases and revealed cold nodules in 237 cases(86.8%), 58 of these cases(24.4%) were malignant. 5) According to the histopathologic classification, benign nodules included follicular adenomas 136 cases(63.5%), adenomatous goiters 67 cases(31.3%), Hurthle cell adenomas 4 cases(1.9%), cysts 3 cases(1.4%) and thyroiditis 4 cases(1.4%). In malignant nodules, papillary carcinomas 72 cases(85.7%), follicular carcinoma 8 cases(9.5%), undifferentiated carcinoma 2 cases(2.4%), medullary carcinoma 1 case(1.2%) and malignant lymphoma 1 case(1.2%). 6) The most commonly performed operative procedure was a lobectomy with isthmusectomy(85.5%) for bengn nodules and a total thyroidectomy(51.2%) for malignant nodules. 7) The rate of complications was higher in the cases with malignant nodules(20.2%) than in the benign cases(0.5%). The recurrence rate was 8.3%(7 cases).

  • PDF

Clinical Features and Prognostic Factors in 41 Patients of Primary Nasal/Nasopharyngeal Non-Hodgkin's Lymphoma: Prognostic Significance of Immunophenotype (비/비인강 비호즈킨 림프종의 임상양상과 예후 인자 : 면역 표현형의 임상적 의의)

  • Park Soon-Seo;Park Jong-Beom;Suh Cheol-Won;Park Ji-Woon;Lim Soo-Duk;Huh Joo-Ryung;Nam Soon-Yuhl;Kim Sang-Yoon;Lee Ho-Gyu;Chang Hye-Sook;Kim Tae-Won;Lee Je-Hwan;Kim Sung-Bae
    • Korean Journal of Head & Neck Oncology
    • /
    • v.15 no.2
    • /
    • pp.149-155
    • /
    • 1999
  • Objectives: To study the clinical features of the primary nasal/nasopharyngeal non-Hodgkin's lymphomas and to evaluate the implication of immunophenotyping as a prognostic factor. Patients and Methods: From January 1990 to December 1997,41 patients(median age, 41 years) of primary nasal/nasopharyngeal non-Hodgkin's lymphoma were studied. The clinical records and paraffin-embedded tissue blocks were reviewed retrospectively. The histologic features, immunophenotypic findings(pan-T, pan-B, CD3, CD56) and Epstein-Barr virus in situ hybridizatios were examined. The prognostic factors for clinical outcome were evaluated in these patients. According to Ann-Arbor system, there were 30 patiets(73%) with stage IE, 4(10%) with stage IIE, 3(7%) with stage IIIE, 4(10%) with stage IVE lymphoma. Among the patients with stage IE/IIE, 4 patients received local radiation alone, 4 received chemotherapy alone, 25 received combination chemotherapy and radiotherapy and 1 refused treatment. The patients with stage IIIE/IVE were given combination chemotherapy and radiotherapy. Results: Immunophenotyping were performed in 40 patients and staining results were as follows: 3(7%) patients with B cell, 17(42%) with T cell, 18(44%) with NK/T cell(CD56 positive), and two patients with unclassifiable result. Epstein-Barr(EB) virus in situ hybridization were performed in 28 patients and 23(82%) patients had positive EBV-encoded RNAs(EBERs). 21(55%) patients achieved a complete remission. There was no difference in complete remission between radiation alone and combination therapy. With median follow-up of 30 months, 5-years disease free survival of complete responders was 60% and 5-years overall survival rate was 36%. Multivariate analysis showed that better overall survival was related with absence of B symptoms, ECOG performance${\leq}1$ and non-NK cells. Conclusion: Most of all cases were positive for EBER. Since NK/T phenotype carried the worst prognosis, analysis for CD56 expression should be done. Further prospective studies were warranted to evaluate the role of chemotherapy in stage IE/IIE.

  • PDF

Treatments Results and Prognostic Factors in Locally Advanced Hypopharyngeal Cancer (국소 진행된 하인두암의 치료 결과와 예후 인자 분석)

  • Yoon, Mee-Sun;Ahn, Sung-Ja;Nam, Taek-Keun;Song, Ju-Young;Nah, Byung-Sik;Lim, Sang-Cheol;Lee, Joon-Kyoo;Chung, Woong-Ki
    • Radiation Oncology Journal
    • /
    • v.25 no.3
    • /
    • pp.151-159
    • /
    • 2007
  • Purpose: The purpose of this study is to present the treatment results and to identify possible prognostic indicators in patients with locally advanced hypopharyngeal carcinoma. Materials and Methods: Between October 1985 to December 2000, 90 patients who had locally advanced stage IV hypopharyngeal carcinoma were studied retrospectively. Twelve patients were treated with radiotherapy alone, 65 patients were treated with a combination of chemotherapy and radiotherapy, and 13 patients were treated with surgery and postoperative radiotherapy with or without neoadjuvant chemotherapy. Total radiation dose ranged from 59.0 to 88.2 Gy (median 70 Gy) for radiotherpay alone. Most patients had ciplatin and 5-fluorouracil, and others had cisplatin and pepleomycin or vincristin. Median follow-up period was 15 months. Kaplan-Meier method was used for survival rate and Cox proportional hazard model for multivariate analysis of prognostic factors. Results: Overall 3-and 5-year survival rates were 27% and 17%, respectively. The 2-year locoregional control rates were 33% for radiotherapy alone, 32% for combined chemotherapy and radiotherapy, and 81 % for combined surgery and radiotherapy (p=0.006). The prognostic factors affecting overall survival were T stage, concurrent chemoradiation and treatment response. Overall 3-and 5-year laryngeal preservation rates in combined chemotherapy and radiotherapy were 26% and 22%, respectively. Of these, the 5-year laryngeal preservation rates were 52% for concurrent chemoradiation group (n=11), and 16% for neoadjuvant chemotherapy and radiotherapy (n=54, p=0.012). Conclusion: Surgery and postoperative radiotherapy showed better results than radiotherapy alone or with chemotherapy. Radiotherapy combined with concurrent chemotherapy is an effective modality to achieve organ preservation in locally advanced hypopharyngeal cancer. Further prospective randomized studies will be required.

Establishment of a Single Dose Radiation Model of Oral Mucositis in Mice (일회 방사선조사를 이용한 마우스 구강점막염 모델의 확립)

  • Ryu, Seung-Hee;Moon, Soo-Young;Choi, Eun-Kyung;Kim, Jong-Hoon;Ahn, Seung-Do;Song, Si-Yeol;Park, Jin-Hong;Noh, Young-Ju;Lee, Sang-Wook
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.257-262
    • /
    • 2008
  • Purpose: Oral mucositis induced by radiotherapy to the head and neck area, is a common acute complication and is considered as the most severe symptom for cancer patients in the early stages of treatment. This study was proposed to establish the oral mucositis mouse model induced by a single dose of radiation for the facility of testing therapeutic candidates which can be used for the oral mucositis treatments. Materials and Methods: Fifty-five BALB/c mice were divided into four groups: control, 16 Gy, 18 Gy, and 20 Gy. Oral mucositis was induced by a single dose of radiation to the head and neck using 6 MV x-Ray from linear accelerator. After irradiation, body weight and physical abnormalities were checked daily. Tongue tissues from all groups were taken on days 1, 2, 3, 5, 7, 9, and 14, respectively and H&E staining was conducted to examine morphological changes. Results: Body weight dramatically decreased after day 5 in all irradiated mice. In the 16 Gy treatment group, body weight was recovered on day 14. The histology data showed that the thickness of the epithelial cell layer was decreased by the accumulated time after radiation treatment, up to day 9. Severe ulceration was revealed on day 9. Conclusion: A single dose of 16 Gy is sufficient dose to induce oral mucositis in Balb/C mice. Significant changes were observed in the Balb/C mice on days 7 and 9 after radiation. It is suggested that this mouse model might be a useful standard tool for studying oral mucositis induced by radiation.

Evaluation on the Accuracy of Targeting Error Correction Through the Application of Target Locating System in Robotic CyberKnife (로봇 사이버나이프에서 위치인식시스템을 이용한 Targeting Error값 보정의 정확성 평가)

  • Jeong, Young-Joon;Jung, Jae-Hong;Lim, Kwang-Chae;Cho, Eun-Ju
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: The purpose is to evaluate the accuracy of correcting the targeting error through the Target Location System (TLS) for the location change error of the reference point which arises from the movement or motion of patient during the treatment using the CyberKnife. Materials and Methods: In this test, Gafchromic MD-55 film was inserted into the head and neck phantom to analyze the accuracy of the targeting, and then the 6 MV X-ray of CyberKnife (CyberKnife Robotic Radiosurgery System G4, Accuray, US) was irradiated. End to End (E2E) program was used to analyze the accuracy of targeting, which is provided by Accuray Corporation. To compute the error of the targeting, the test was carried out with the films that were irradiated 12 times by maintaining the distance within the rage of $0{\pm}0.2\;mm$ toward x, y, z from the reference point and maintaining the angle within the rage of $0{\pm}0.2^{\circ}$ toward roll, pitch, yaw, and then with the films which were irradiated 6 times by applying intentional movement. And the correlation in the average value of the reference film and the test film were analyzed through independent samples t-test. In addition, the consistency of dose distribution through gamma-index method (dose difference: 3%) was quantified, compared, and analyzed by varying the distance to agreement (DTA) to 1 mm, 1.5 mm, 2 mm, respectively. Results: E2E test result indicated that the average error of the reference film was 0.405 mm and the standard deviation was 0.069 mm. The average error of the test film was 0.413 mm with the standard deviation of 0.121 mm. The result of independent sampling t-test for both averages showed that the significant probability was P=0.836 (confidence level: 95%). Besides, by comparing the consistency of dose distribution of DTA through 1 mm, 1.5 mm, 2 mm, it was found that the average dose distribution of axial film was 95.04%, 97.56%, 98.13%, respectively in 3,314 locations of the reference film, consistent with the average dose distribution of sagittal film that was 95.47%, 97.68%, 98.47%, respectively. By comparing with the test film, it was found that the average dose distribution of axial film was 96.38%, 97.57%, 98.04%, respectively, at 3,323 locations, consistent with the average dose distribution of sagittal film which was 95.50%, 97.87%, 98.36%, respectively. Conclusion: Robotic CyberKnife traces and complements in real time the error in the location change of the reference point caused by the motion or movement of patient during the treatment and provides the accuracy with the consistency of over 95% dose distribution and the targeting error below 1 mm.

  • PDF

Analysis of the major factors of influence on the conditions of the Intensity Modulated Radiation Therapy planning optimization in Head and Neck (두경부 세기견조방사선치료계획 최적화 조건에서 주요 인자들의 영향 분석)

  • Kim, Dae Sup;Lee, Woo Seok;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.11-19
    • /
    • 2014
  • Purpose : To derive the most appropriate factors by considering the effects of the major factors when applied to the optimization algorithm, thereby aiding the effective designing of a ideal treatment plan. Materials and Methods : The eclipse treatment planning system(Eclipse 10.0, Varian, USA) was used in this study. The PBC (Pencil Beam Convolution) algorithm was used for dose calculation, and the DVO (Dose Volume Optimizer 10.0.28) Optimization algorithm was used for intensity modulated radiation therapy. The experimental group consists of patients receiving intensity modulated radiation therapy for the head and neck cancer and dose prescription to two planned target volume was 2.2 Gy and 2.0 Gy simultaneously. Treatment plan was done with inverse dose calculation methods utilizing 6 MV beam and 7 fields. The optimal algorithm parameter of the established plan was selected based on volume dose-priority(Constrain), dose fluence smooth value and the impact of the treatment plan was analyzed according to the variation of each factors. Volume dose-priority determines the reference conditions and the optimization process was carried out under the condition using same ratio, but different absolute values. We evaluated the surrounding normal organs of treatment volume according to the changing conditions of the absolute values of the volume dose-priority. Dose fluence smooth value was applied by simply changing the reference conditions (absolute value) and by changing the related volume dose-priority. The treatment plan was evaluated using Conformal Index, Paddick's Conformal Index, Homogeneity Index and the average dose of each organs. Results : When the volume dose-priority values were directly proportioned by changing the absolute values, the CI values were found to be different. However PCI was $1.299{\pm}0.006$ and HI was $1.095{\pm}0.004$ while D5%/D95% was $1.090{\pm}1.011$. The impact on the prescribed dose were similar. The average dose of parotid gland decreased to 67.4, 50.3, 51.2, 47.1 Gy when the absolute values of the volume dose-priority increased by 40,60,70,90. When the dose smooth strength from each treatment plan was increased, PCI value increased to $1.338{\pm}0.006$. Conclusion : The optimization algorithm was more influenced by the ratio of each condition than the absolute value of volume dose-priority. If the same ratio was maintained, similar treatment plan was established even if the absolute values were different. Volume dose-priority of the treatment volume should be more than 50% of the normal organ volume dose-priority in order to achieve a successful treatment plan. Dose fluence smooth value should increase or decrease proportional to the volume dose-priority. Volume dose-priority is not enough to satisfy the conditions when the absolute value are applied solely.

Development of a Thermoplastic Oral Compensator for Improving Dose Uniformity in Radiation Therapy for Head and Neck Cancer (두경부암 방사선치료 시 선량 균일도 향상을 위한 Thermoplastic 구강 보상체의 개발)

  • Choi, Joon-Yong;Won, Young-Jin;Park, Ji-Yeon;Kim, Jong-Won;Moon, Bong-Ki;Yoon, Hyong-Geun;Moon, Soo-Ho;Jeon, Jong-Byeong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.269-278
    • /
    • 2012
  • Aquaplast Thermoplastic (AT) is a tissue-equivalent oral compensator that has been developed to improve dose uniformity at the common boundary and around the treated area during radiotherapy in patients with head and neck cancer. In order to assess the usefulness of AT, the degree of improvement in dose distribution and physical properties were compared to those of oral compensators made using paraffin, alginate, and putty, which are materials conventionally used in dental imprinting. To assess the physical properties, strength evaluations (compression and drop evaluations) and natural deformation evaluations (volume change over time) were performed; a Gafchromic EBT2 film and a glass dosimeter inserted into a developed phantom for dose verification were used to measure the common boundary dose and the beam profile to assess the dose delivery. When the natural deformation of the oral compensators was assessed over a two-month period, alginate exhibited a maximum of 80% change in volume from moisture evaporation, while the remaining tissue-equivalent properties, including those of AT, showed a change in volume that was less than 3%. In a free-fall test at a height of 1.5 m (repeated 5 times as a strength evaluation), paraffin was easily damaged by the impact, but AT exhibited no damage from the fall. In compressive strength testing, AT was not destroyed even at 8 times the force needed for paraffin. In dose verification using a glass dosimeter, the results showed that in a single test, the tissue-equivalent (about 80 Hounsfield Units [HU]) AT delivered about 4.9% lower surface dose in terms of delivery of an output coefficient (monitor unit), which was 4% lower than putty and exhibited a value of about 1,000 HU or higher during a dose delivery of the same formulation. In addition, when the incident direction of the beam was used as a reference, the uniformity of the dose, as assessed from the beam profile at the boundary after passing through the oral compensators, was 11.41, 3.98, and 4.30 for air, AT, and putty, respectively. The AT oral compensator had a higher strength and lower probability of material transformation than the oral compensators conventionally used as a tissue-equivalent material, and a uniform dose distribution was successfully formed at the boundary and surrounding area including the mouth. It was also possible to deliver a uniformly formulated dose and reduce the skin dose delivery.

Application of Off-axis Correction Method for EPID Based IMRT QA (EPID를 사용한 세기조절방사선치료의 정도관리에 있어 축이탈 보정(Off-axis Correction)의 적용)

  • Cho, Ilsung;Kwark, Jungwon;Park, Sung Ho;Ahn, Seung Do;Jeong, Dong Hyeok;Cho, Byungchul
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.317-325
    • /
    • 2012
  • The Varian PORTALVISION (Varian Medical Systems, US) shows significant overresponses as the off-center distance increases compared to the predicted dose. In order to correct the dose discrepancy, the off-axis correction is applied to VARIAN iX linear accelerators. The portal dose for $38{\times}28cm^2$ open field is acquired for 6 MV, 15 MV photon beams and also are predicted by PDIP algorithm under the same condition of the portal dose acquisition. The off-axis correction is applied by modifying the $40{\times}40cm^2$ diagonal beam profile data which is used for the beam profile calibration. The ratios between predicted dose and measured dose is modeled as a function of off-axis distance with the $4^{th}$ polynomial and is applied to the $40{\times}40cm^2$ diagonal beam profile data as the weight to correct measured dose by EPID detector. The discrepancy between measured dose and predicted dose is reduced from $4.17{\pm}2.76$ CU to $0.18{\pm}0.8$ CU for 6 MV photon beam and from $3.23{\pm}2.59$ CU to $0.04{\pm}0.85$ CU for 15 MV photon beam. The passing rate of gamma analysis for the pyramid fluence patten with the 4%, 4 mm criteria is improved from 98.7% to 99.1% for 6 MV photon beam, from 99.8% to 99.9% for 15 MV photon beam. IMRT QA is also performed for randomly selected Head and Neck and Prostate IMRT plans after applying the off-axis correction. The gamma passing rare is improved by 3% on average, for Head and Neck cases: $94.7{\pm}3.2%$ to $98.2{\pm}1.4%$, for Prostate cases: $95.5{\pm}2.6%$, $98.4{\pm}1.8%$. The gamma analysis criteria is 3%, 3 mm with 10% threshold. It is considered that the off-axis correction might be an effective and easily adaptable means for correcting the discrepancy between measured dose and predicted dose for IMRT QA using EPID in clinic.

Development of Devices for Improving the Reducibility of Patient Positioning on a Breast Board (Breast Board를 이용한 방사선치료에서 환자 위치 재현성 향상 방안에 대한 연구)

  • Huh Soon Nyung;Cho Woong;Park Yang Kyun;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.123-130
    • /
    • 2005
  • Purpose: We wanted to improve the setup reproducibility of breast cancer patients when utilizing a commercially available breast board for radiation therapy. The breast board was modified by using a new head rest and 2 types of board fixation devices. Materials and Methods: A conventional head/neck rest was modified to be positioned in various slots of the breast board, and it was fabricated 1 cm thinner to provide more comfort to a patient when the patient's neck was rotated. This rest improves the uncertainty of the daily setup. Also, the sagging problems at the left and right sides became negligible with the two types of board fixation devices: (1) the stair type, and (2) the arm type. The first device consists of an upper/lower holder with 4 stair-types of grooves and 4 rectangular Inserts. In order to cover the whole range of vertical setup of the breast board, 4 rectangular inserts were needed, and each covered 10 steps. The arm-type fixation device was also fabricated and attached to the breast board, It had two aluminum bars that were fixed by utilizing a lock-type of screw. These devises were evaluated with two volunteers in order to prove the effectiveness of the improved setup accuracy. Results; The developed cranio-caudal fixation device demonstrated that it could reduce the cranio-caudal error by nearly $55\%$ compared to the old device. As for left-and-right inclination, the stair-type and arm-type fixation devices can reduce the relative inclination by nearly $80\%$ and $90\%$, respectively, compared to the breast board without the fixation device. Conclusion: It was verified that the developed devices were effective for positioning the patients and for avoiding inclination of the breast board.

Significance of Apoptotic Cell Death after $\gamma-Irradiation$ (방사선 조사에 의한 세포사에 있어서 세포고사의 의미)

  • Wu H.G.;Kim I.H.
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.252-258
    • /
    • 2001
  • Purpose : The objectives of this study are to investigate the significance of apoptotic death compared to total cell death after $\gamma-ray$ irradiation in human H&N cancer cell lines and to find out correlation between apoptosis and radiation sensitivity. Materials and method : Head and neck cancer cell lines (PCI-1, PCI-13, and SNU-1066), leukemia cell line (CCRF-CEM), and fibroblast cell line (LM217) as a normal control were used for this study. Cells were irradiated using Cs-137 animal experiment irradiator. Total cell death was measured by clonogenic assay. Annexin-V staining was used to detect the fraction of apoptotic death. Results : Surviving fraction at 2 Gy (SF2) were 0.741, 0.544, 0.313, 0.302, and 0.100 for PCI-1, PCI-13, SNU-1066, CCRF-CEM, and LM217 cell lines, respectively. Apoptosis was detected in all cell lines. Apoptotic index reached peak value at 72 hours after irradiation in head and neck cancer cell lines, and that was at 24 hours in CCRF-CEM and LM217. Total cell death increased exponentially with increasing radiation dose from 0 Gy to 8 Gy, but the change was minimal in apoptotic index. Apoptotic fractions at 2 Gy were $46\%,\;48\%,\;46\%,\;24\%,\;and\;19\%$ and at 6 Gy were $20\%,\;33\%,\;35\%,\;17\%,\;and\;20\%$ for PCI-1, PCI-13, SNU-1066, CCRF-CEM, and LM217, respectively. The radioresistant cell lines showed more higher apoptotic fraction at 2 Gy, but there was not such correlation at 6 Gy. Conclusion : All cell lines used in this study showed apoptosis after irradiation, but time course of apoptosis was different from that of leukemia cell line and normal fibroblast cell line. Reproductive cell death was more important mode of cell death than apoptotic death in all cell lines used in this study. But there was correlation between apoptotic fraction and radiation sensitivity at 2 Gy.

  • PDF