• 제목/요약/키워드: Head coil

검색결과 124건 처리시간 0.025초

완전 이식형 인공중이를 위한 베개형 비접촉 충전장치의 설계 (Design of pillow type contactless recharging device for totally implantable middle ear systems)

  • 임형규;김종민;김민규;윤영호;박일용;송병섭;조진호
    • 센서학회지
    • /
    • 제14권2호
    • /
    • pp.78-84
    • /
    • 2005
  • A contactless recharging device for totally implantable middle ear systems has been designed as a pillow type that the user can recharge the implanted battery with taking a rest. The proposed device uses the electromagnetic coupling between the transmitting coil and the receiving coil. To supply sufficient power for the implanted circuits, each coil uses LC resonance and the implanted device uses voltage doubler. A power MOSFET is used for switching the DC voltage of LC parallel circuit and the switching frequency demands on a programmable frequency generator which is controlled by microcontroller. In order to improve the electromagnetic coupling efficiency at specific positions of coil which may vary with the displacement of head, the optimal location of receiving coil was studied, and the 5 transmitting coils in a pillow for recharging the implant module was designed. From such a recharging experiment, it was found that the proposed device could provide the sufficient operating voltage within the distance of 4 cm between pillow and the implanted device.

역-솔레노이드 코일을 이용한 내부 영상용 핵자기공명 영상 탐침의 제작 (Construction of magnetic Resonance Imaging Probe for Internal Imaging Using Anti-Solenoid Coil)

  • 이동훈;고락길
    • 자연과학논문집
    • /
    • 제8권1호
    • /
    • pp.27-32
    • /
    • 1995
  • 역-솔레노이드 코일 형태를 이용한 핵자기공명용 내부영상 탐침을 제작하였다. 역-솔레노이드 탐침들로 획득된 영상의 신호-대-잡음비를 시제품 탐침인 머리코일과 몸통코일로 얻은 것들과 비교하였다. 내부영상에 관한한, 본 논문에서 제작된 역-솔레이노이드 탐침들이 위의 시제품 탐침들보다 향상된 기능성을 보였다. 그리고, 역-솔레노이드 탐침들이 형성하는 RF-자기장의 분포를 컴퓨터를 이용하여 계산하였다. 아울러, 본 논문에서 제작된 역-솔레노이드 탐침을 이용한 인체의 내부영상의 가능성에 대해서도 논의하였다.

  • PDF

Development of TEM Coil for Animal Experiments at 3T MRI System

  • Chu, Myung-Ja;Choe, Bo-Young;Kim, Kyung-Nam;Chung, Sung-Taek;Oh, Chang-Hyun;Lee, Hyoung-Koo;Suh, Tae-Suk
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.78-78
    • /
    • 2002
  • Purpose: The purpose of this study is to describe a distributed circuit approach to high frequency volume coil design illustrated with specific coils built accordingly and results obtained from animal studies at 3.0 tesla. Method: All experiments were conducted on 3T MRI system (Medinus Co., Ltd. Korea). The tuned TEM resonator measures 15cm outer diameter. by 10cm inside diameter by 30cm in length. The inside diameter and length were determined by animals body or head size (eg. rats or small dogs, etc.) while the outer diameter was chosen for compactness with some sacrifice of the optimal coil Q predicted for a larger cavity. A spin echo sequence with a TR/TE/flip angle=500/12.4ms/$75^{\circ}$was used to check image qualities with phantom. The breed of rat which used for animal images was Sprague-dawley(SD) and was anesthetic using ketamin hydrochloride 75mg/kg.

  • PDF

Advances in Fast Vessel-Wall Magnetic Resonance Imaging Using High-Density Coil Arrays

  • Yin, Xuetong;Li, Nan;Jia, Sen;Zhang, Xiaoliang;Li, Ye
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권4호
    • /
    • pp.229-251
    • /
    • 2021
  • Arteriosclerosis is the leading cause of stroke, with a fatality rate surpassing that of ischemic heart disease. High-resolution vessel wall magnetic resonance imaging is generally recognized as a non-invasive and panoramic method for the evaluation of arterial plaque; however, this method requires improved signal-to-noise ratio and scanning speed. Recent advances in high-density head and neck coil arrays are characterized by broad coverage, multiple channels, and closefitting designs. This review analyzes fast magnetic resonance imaging from the perspective of accelerated algorithms for vessel wall imaging and demonstrates the need for effective algorithms for signal acquisition using advanced radiofrequency system. We summarize different phased-array structures under various experimental objectives and equipment conditions, introduce current research results, and propose prospective research studies in the future.

실별제어 온수분배기의 유량분배 특성 (A Flow Quantity Distribution Characteristics of the Hot Water Header for Individual Room Control System)

  • 성순경
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.175-180
    • /
    • 2008
  • Flow quantity to supply to a coil in floor heating system is important to achieve comfortable indoor air condition in the winter season. The hot water header is used to distribute the water into the coil. Experimental study has been performed using the water header that have 5 branches consisted of flow control valves and automatic shut-off valves. Each branch line connected it with X-L pipe. Experimental tests accomplished it to investigate the flow distribution characteristics of the hot water header. Experimental results show that the selection of the pump head and differential pressure are very important to save running energy of the system, and high differential pressure needs more friction loss in the case of suitable differential pressure for balancing of the header.

Membrane interaction of the coiled-coil motif of HIV gp41 and its implication in the membrane fusion process

  • Jin, Bong-Suk;Yu, Yeon-Gyu
    • 한국생물물리학회:학술대회논문집
    • /
    • 한국생물물리학회 2003년도 정기총회 및 학술발표회
    • /
    • pp.58-58
    • /
    • 2003
  • The envelope glycoprotein of HIV, gp41, mediates the membrane fusion with human cells. The extracellular domain of gp41 has two helical regions. The N-terminus helical region (N-helix) forms trimeric coiled coil, interacts with the C-terminus helical region (C-helix) of gp41 to form a stable helical bundle structure. In this study, we have shown that the N-helix of gp41 has membrane interacting and disrupting abilities. It was localized into the interface of the lipidic phase and head group of the membrane. In contrast, the N-helix region with membrane fusion defective mutations could not bind to membrane. In addition, the N-helix bound on the membrane was released from the membrane by the C-helix, and the complex of the N- and C-helix did not interact with membrane. These results suggested that the membrane binding ability of the N-helix is necessary for the fusion activity of gp41, and such property is possibly controlled by the C-helm.

  • PDF

7T 악관절 MRI를 위한 4 채널 스파이럴 RF 코일의 성능개선 (Improvement of a 4-Channel Spiral-Loop RF Coil Array for TMJ MR Imaging at 7T)

  • 김경남;김영보;조장희
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권2호
    • /
    • pp.103-114
    • /
    • 2012
  • 목적: 7T 악관절 자기공명상의 개선을 위해 제안된 4 채널 스파이럴 코일과 그를 구동시키기 위한 회로는 자기장의 분포, 송신 전용필드, 신호 대 잡음 비, 그리고 악관절 영상에 대하여 일반적인 단일 루프 형태의 코일과 비교되었다. 대상과 방법: 단일 채널 그리고 4 채널 스파이럴 코일은 단일 루프 형태의 코일에 대해 전자기장 시뮬레이션으로 자기장의 분포 및 송신 전용 필드에 대해서 비교 되었고, 7T에서 이를 평가하고자 송신전용 필드와 더불어 자기장의 분포 역시 비교 평가되었다. 결과: 전자기장 시뮬레이션의 결과와 7T 자기공명영상에서 4 채널 스파이럴 코일은 기존에 사용되는 일반적인 구조인 단일 루프 코일에 비해 상대적으로 우수한 자기장의 분포 및 송신 전용 필드를 보였다. 결론: 7T에서는 코일의 구조에 비해 상대적으로 영상화되는 물질의 특성에 더욱더 의존적이나, 각각의 코일은 다른 필드 분포를 나타냄으로써 최적화된 코일은 악관절 영상과 같은 특정 용도로 사용될 수 있음을 확인하였다.

다중채널코일과 병렬영상기법 이용 시 두영역측정법을 사용한 신호대잡음비 측정의 문제점 (A study on Evaluating Validity of SNR Calculation Using a Conventional Two Region Method in MR Images Applied a Multichannel Coil and Parallel Imaging Technique)

  • 최관우;손순룡;민정환;권경태;유병규;이종석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.403-410
    • /
    • 2015
  • 본 연구는 다중채널코일과 병렬영상기법 이용 시 관행적으로 사용하고 있는 두영역측정법을 사용한 신호대잡음비 측정의 문제점을 알아보고자 하였다. 두영역측정법 사용 시 3가지 전제 조건에 만족하는 단일채널구상코일을 이용한 기준 SNR을 산출한 후, 다중채널코일과 병렬영상기법 이용 시 공신력 있는 기관에서 권고하는 방법과 전제 조건을 고려하지 않고 사용되어 문제가 되는 두영역측정법을 사용하여 SNR을 산출한 후 비교하였다. 다중채널코일과 병렬영상기법 이용 한 두영역측정법이 가장 높은 상대표준편차를 보여 낮은 정밀도를 나타내었고, ROI 위치에 따른 SNR 차이도 매우 높아 공간적으로 잡음의 분포가 균일하지 않음을 알 수 있었다. Blend-Altman plot 통한 95% 신뢰구간 간격도 가장 넓어 기준이 되는 단일채널구상코일을 이용한 두영역측정법 대비 일치도가 낮음을 알 수 있었다. 본 연구는 동일한 영상획득조건에서 자기공명영상장치 성능평가 시험의 표준이 되는 AAPM 방법과, 신호 영역 내에서 잡음 레벨을 정확히 결정할 수 있는 NEMA 방법, 그리고 자기공명영상장치의 제조사가 권고하는 방법을 직접적으로 비교함으로써, 연구자들이 간과할 수 있는 전제조건을 만족하지 않는 다중채널코일과 병렬영상기법 이용 시, 두영역측정법을 사용한 신호대잡음비의 부정확한 문제점을 정량적으로 증명하였다는데 큰 의의가 있다.