Kim, Moon-Chan;Lim, Jong-Suck;Park, Hyung-Ro;Kim, You-Hyun
Journal of radiological science and technology
/
v.27
no.2
/
pp.21-27
/
2004
This study was conducted to estimate absorbed radiation doses associated with CT examinations. We compared CT dose index between single detector CT and multi detector CT. To establish radiation dose criteria in CT examination in Korea, we measured radiation dose for CT examinations in Seoul and kyungki-do. The results obtained were as follows ; 1. Averaged CTDIW value per 100 mAs was $13.5{\pm}3.2\;mGy$, and ranged from 8.1 mGy to 19.1 mGy in head phantom, was $7.1{\pm}2.0\;mGy$, and ranged from 3.7 mGy to 10.9 mGy in body phantom. 2. CTDIW was 3.2 mGy(1.26 times) larger in multi detector CT than single detector CT in head phantom, and 2.1 mGy(1.34 times) larger in body phantom. 3. The dose was the highest in 4 channel multi detector CT, and followed 8 channel multi detector CT, 16 channel multi detector CT and single detector CT in head phantom. And the dose was the highest in 4 channel and 8 channel multi detector CT, and followed 16 channel multi detector CT and single detector CT in body phantom.
Background and Objectives: The aim of our study was to describe the appearance of recurrent and residual lesions in the head and neck tumors, and to evaluate the usefullness of CT and MRI. Materials and Methods: CT(n=42) and MRI(n=4) of 44 patients with recurrent head and neck tumors were reviewed retrospectively. Primary tumor sites were larynx/hypopharynx in 15, oral cavity/floor of mouth in 13, base of tongue/tonsil in 5, nasopharynx in 4, palate in 2, and others in 5 patients. Therapeutic modalities included sugery and radiotherapy in 23, radiotherapy in 11, surgery in 5, chemotherapy and radiotherapy in 4, and chemotherapy in 1 patient. Results: The patterns of tumor recurrence were nodal recurrence(n=17), primary tumor bed recurrence combined with nodal recurrence(n=12), primary tumor bed recurrence(n=10) and residual primary tumors(n=5). The most common appearance of residual/recurrent primary tumor on CT was focal or diffuse heterogenous mass with or without surrounding fat or muscle infiltration(25/27). On MRI, the recurrent lesions showed intermediate signal intensity on T1 weighted image and high signal intensity on T2 weighted image with heterogenous enhancement in the most cases(n=3). 38 out of 44 nodal recurrences(86%) which had been pathologically or clinically proved were more than 1 cm in diameter or contained central low density on CT scan. Conclusion: Although CT and MRI findings of recurrent and residual tumors of the head and neck were nonspecific, in the majority the lesions manifested as a mass at primary tumor bed and/or nodal disease including contralateral side of the neck. And CT and MRI are valuable for revealing above lesions.
Ku, Cheol Hyo;Kim, Soo Won;Kim, Ji Young;Paik, Seung Won;Yang, Hui Joon;Lee, Ji Hyeon;Seo, Young Joon
Journal of Audiology & Otology
/
v.24
no.1
/
pp.17-23
/
2020
Background and Objectives: We aimed to measure the head dimensions on computed tomography (CT) images, to compare them to directly measured head dimensions, and to predict a new parameter of bone thickness for aiding bone conduction implant (BCI) placement. Subjects and Methods: We reviewed the facial and mandibular bone CT images of 406 patients. Their head sizes were analyzed using five parameters included in the 6th Size Korea project, and they were divided into age groups (ranging from the 10s to the 80s). We compared the head length, head width, sagittal arc, bitragion arc, and head circumference in the CT and Size Korea groups. We also added the parameter bone thickness for aiding BCI placement. Results: All the head size parameters measured using CT were significantly smaller than those measured directly, with head length showing the smallest difference at 7.85 mm. The differences in the other four parameters between the two groups according to patient age were not statistically significantly different. Bone thickness had the highest value of 4.89±0.93 mm in the 70s and the lowest value of 4.10±0.99 mm in the 10s. Bone thickness also significantly correlated with head width (p=0.038). Conclusions: Our findings suggested that the CT and direct measurements yielded consistent data. Moreover, CT enabled the measurement of bone sizes, including bone thickness, that are impossible to measure directly. CT measurements may complement direct measurements in the Size Korea data when used for developing bone conduction hearing devices (BCIs and headsets) for the Korean population.
Ku, Cheol Hyo;Kim, Soo Won;Kim, Ji Young;Paik, Seung Won;Yang, Hui Joon;Lee, Ji Hyeon;Seo, Young Joon
Korean Journal of Audiology
/
v.24
no.1
/
pp.17-23
/
2020
Background and Objectives: We aimed to measure the head dimensions on computed tomography (CT) images, to compare them to directly measured head dimensions, and to predict a new parameter of bone thickness for aiding bone conduction implant (BCI) placement. Subjects and Methods: We reviewed the facial and mandibular bone CT images of 406 patients. Their head sizes were analyzed using five parameters included in the 6th Size Korea project, and they were divided into age groups (ranging from the 10s to the 80s). We compared the head length, head width, sagittal arc, bitragion arc, and head circumference in the CT and Size Korea groups. We also added the parameter bone thickness for aiding BCI placement. Results: All the head size parameters measured using CT were significantly smaller than those measured directly, with head length showing the smallest difference at 7.85 mm. The differences in the other four parameters between the two groups according to patient age were not statistically significantly different. Bone thickness had the highest value of 4.89±0.93 mm in the 70s and the lowest value of 4.10±0.99 mm in the 10s. Bone thickness also significantly correlated with head width (p=0.038). Conclusions: Our findings suggested that the CT and direct measurements yielded consistent data. Moreover, CT enabled the measurement of bone sizes, including bone thickness, that are impossible to measure directly. CT measurements may complement direct measurements in the Size Korea data when used for developing bone conduction hearing devices (BCIs and headsets) for the Korean population.
Seo Seok Jin;Kim Chan Yoeng;Lee Je Hee;Park Heung Deuk
The Journal of Korean Society for Radiation Therapy
/
v.17
no.1
/
pp.45-55
/
2005
Purpose : To evaluate the usefulness of the handmade patient immobilization device and to report the clinical results of it. Materials and methods : We made two fusion images and analyzed those images. One image is made with diagnostic MR image and CT image, the other with therapeutic planning MR image and CT image. With open head holder, we measured the skin dose and attenuation dose. Also, we made the planning CT couch plate with acrylic plate and styrofoam and compared artifact. Results : We could get more accurate fusion image when we use MR head holder(within 2mm error). The skin dose was reduced 2 times and the attenuation dose was reduced more than $20\%$ when open head holder used. The planning CT couch plate was more convenient than conventional board and reduced artifact remarkably. Conclusion : We could verify the localization point in the MR image which is taken with MR head holder. So we could fuse the image more accurately. The same method could be applied to PET and US image, if the alike immobilization device used. With open head holder, the skin dose and the attenuation dose was reduced. And those above devices could substitute for expensive foreign device, if those are manufactured adequately.
The aim of this study is to assess the dose reduction of eye lens and availability of bismuth garments resulting from the use of radioprotective bismuth garments to shield the eyes of patients undergoing head CT. Rando phantom and TLDs were used to determine the amount of dose reduction by bismuth shielding of the eye in the following simulated CT scans : (a) scanning of the head including orbits, (b) scanning of the whole head, and (c) $20^{\circ}$ angled scanning of the head excluding orbits. The average dose reduction of eye lens was 43.2%, 36.0% and 1.4% for the three CT scans listed above. Significant reduction in the eye lens dose was achieved by using superficial orbital bismuth shielding during head CT scans. However, bismuth shields should not be used for the patients when their eyes are excluded from the primarily exposed region.
서 론 : 두경부암의 예후에 가장 중요한 인자는 진단시 병기와 치료 후 재발의 유무이다. 따라서, 재발 병변을 조기에 발견하는 것이 매우 중요하다. 본 연구에서는 두경부암 환자의 추적 관찰에서 $^{18}F$-FDG PET/CT의 유용성에 대해 알아보고자 하였다. 대상 및 방법 : 2004년 4월부터 2008년 8월까지 고려대 안암병원에서 두경부암으로 치료를 완료한 후 추적관찰이 가능하였던 88 예의 환자를 대상으로 하였다. 환자는 본원의 두경부암 추적관찰 양식에 따라 술 후 6, 12개월째 $^{18}F$-FDG PET/CT를 시행하였으며, 원발부위 및 경부 재발, 원격전이와 중복암의 진단에 있어 $^{18}F$-FDG PET/CT의 민감도, 특이도, 양성예측율, 음성예측율을 평가하였고, 기존의 추적관찰 방법과 이를 비교하였다. 결 과 : 원발부위 재발의 진단에 있어 민감도, 특이도, 양성예측율, 음성예측율은 각각 95%, 97%, 90%, 98% 였다. 경부전이 재발의 진단에 있어서는 각각 94%, 98%, 83%, 99%였으며, 원격전이 및 이차암 진단에 있어서는 94%, 100%, 100%, 99%였다. 원발부위 재발은 고식적인 진단 방법, 원격전이와 이차암은 $^{18}F$-FDG PET/CT가 진단에 의미있게 유리하였다. 결 론 : $^{18}F$-FDG PET/CT는 두경부암의 추적관찰 과정에서 재발 여부를 판정하는데 있어 매우 유용하며, 특히 원격전이 및 이차암의 발견에 있어 유용하다. 그러나, 위양성 및 위음성의 가능성으로 고식적인 진단 방법과 병행해야 진단의 효과를 높힐 것으로 생각된다.
The Journal of Korean Society for Radiation Therapy
/
v.22
no.2
/
pp.85-95
/
2010
Purpose: The degradation of an image quality and error of the beam dose calculation can be caused because the metal artifact is generated during the CT simulation of head and neck patient. The usability of the gantry tilt scan for reducing the metal artifact tries to be appraised. Materials and Methods: The inferior $20^{\circ}$ gantry tilt scan was made in order to reduce the metal artifact and $0^{\circ}$ reconstruction image was acquired. The AAPM CT performance Phantom was used in order to compare the CT number of the reconstructed image and Original image. the difference of volume was compared by using the acrylic phantom. The homogeneity of the CT number was evaluated the Intensity volume Histogram (IVH) as in order to evaluate an influence by the metal artifact. A dose was evaluated as the Dose Volume Histogram (DVH). Results: in the comparison of the CT number and volume, the difference showed up less than 0.5%. As to the comparison of IVH, in the gantry tilt scan, influence by an artifact was reduced and the homogeneity of the CT number was improved. The comparison of DVH result reduced the mean dose error of the both sides parotid 0.2~6%. Conclusion: In the Head & Neck radiation therapy, It is difficult and to distinguish tumor and normal tissue and the error of dose is generated by the metal artifact. The delineation of the exact organization was possible if the Gantry tilt scan was used. The CT number homogeneity was improved and the error of dose could be reduced. The Gantry tilt scan confirmed in the Head & Neck radiation therapy to be very useful in the exact radiation therapy.
Kim, Won-Hyung;Lim, Dong-Jun;Kim, Se-Hoon;Ha, Sung-Kon;Choi, Jong-Il;Kim, Sang-Dae
Journal of Korean Neurosurgical Society
/
v.58
no.2
/
pp.125-130
/
2015
Objective : Repeated computed tomography (CT) follow up for traumatic brain injury (TBI) patients is often performed. But there is debate the indication for repeated CT scans, especially in pediatric patients. Purpose of our study is to find risk factors of progression on repeated CT and delayed surgical intervention based on the repeated head CT. Methods : Between March, 2007 and December, 2013, 269 pediatric patients (age 0-18 years) had admitted to our hospital for head trauma. Patients were classified into 8 subgroups according to mechanisms of injury. Types, amount of hemorrhage and amount changes on repeated CT were analyzed as well as initial Glasgow Coma Scale (GCS) scores. Results : Within our cohort of 269 patients, 174 patients received repeat CT. There were progression in the amount of hemorrhage in 48 (27.6%) patients. Among various hemorrhage types, epidural hemorrhage (EDH) more than 10 cc measured in initial CT was found to be at risk of delayed surgical intervention significantly after routine repeated CT with or without neurological deterioration than other types of hemorrhage. Based on initial GCS, severe head trauma group (GCS 3-8) was at risk of delayed surgical intervention after routine repeated CT without change of clinical neurologic status. Conclusion : We suggest that the patients with EDH more than 10 cc or GCS below 9 should receive repeated head CT even though absence of significant clinical deterioration.
Park, So Young;Jung, Jae Yun;Kwak, Young Ho;Kim, Do Kyun;Suh, Dong Bum
Journal of Trauma and Injury
/
v.25
no.4
/
pp.152-158
/
2012
Purpose: To understand the epidemiology of head trauma and the utilization of brain CT in Korea, we analyzed a national sampling data set, the National Patient Sample obtained from the Health Insurance Review and Assessment Service. Methods: We retrospectively collected and analyzed demographic and clinical data on enrolled patients from the National Patient Sample based on medical claims data for 2009. The data included patient's age, sex, treatment date, diagnosis codes, procedure codes related with CT, holiday or night consultation fee, and fee for emergency management services. Results: In 2009, the estimated population with head trauma was 819,059(1.8%), and the rate of brain CT utilization was 22.4%. Children ages 5 to 15 were the most commonly injured group(22.8%), but had the lowest brain CT utilization(16.5%). The mean age of the estimated population with head trauma was $34.9{\pm}0.5years$ old, and male patients accounted for 60.5% of that population. Intracranial injury was found in 8.6% of all head traumas, and the rate of intracranial injury in children was lower than it was in adults(4.1% vs. 10.9%, p<0.001). Twenty- three percent of patients with head trauma visited the emergency department (ED). More patients with head trauma visited medical facilities in the daytime on weekdays(66.5% vs. 33.5%, p<0.001), but head CT was performed more frequently at night or on weekends/holidays(16.1% vs. 34.7%, p<0.001) There is low incidence of head trauma in the winter in children (p<0.001). In the multivariate logistic regression analysis, patients who were adults, female, or ED visitors were more likely to undergo brain CT (odds ratio (OR): 1.65, 95% confidence interval (CI): 1.47-1.84; OR: 1.40, 95% CI: 1.27-1.54; OR: 7.80, 95% CI: 6.91-8.80, respectively). Conclusion: In this study, we analyzed the national epidemiologic trend for head trauma, and the pattern of utilization of brain CT.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.