Assessment of the Eye Lens Dose Reduction by Bismuth Shields in Rando Phantom Undergoing CT of the Head
Head CT 검사 시 안구 차폐용 Bismuth사용에 의한 수정체 선량 감소에 대한 평가
- Cho, Pyong-Kon (Department of Radiology, Ansan Hospital, Korea University Medical Center) ;
- Kim, You-Hyun (Dept. of Radiologic Science, College of Health Science, Korea University) ;
- Choi, In-Ja (Department of Radiology, Ansan Hospital, Korea University Medical Center) ;
- Chang, Sang-Gyu (Department of Radiology, Ansan Hospital, Korea University Medical Center) ;
- Chung, Jung-Pyo (Department of Radiology, Ansan Hospital, Korea University Medical Center) ;
- Lee, Hyun (Department of Radiology, Ansan Hospital, Korea University Medical Center) ;
- Kim, Jang-Seob (Department of Radiology, Ansan Hospital, Korea University Medical Center) ;
- Shin, Dong-Cheol (Department of Radiology, Ansan Hospital, Korea University Medical Center) ;
- Choi, Jong-Hak (Dept. of Radiologic Science, College of Health Science, Korea University) ;
- Lee, Ki-Sung (Dept. of Radiologic Science, College of Health Science, Korea University) ;
- Lee, Won-Ho (Dept. of Radiologic Science, College of Health Science, Korea University)
- 조평곤 (고려대학교 안산병원 영상의학과) ;
- 김유현 (고려대학교 보건과학대학 방사선학과) ;
- 최인자 (고려대학교 안산병원 영상의학과) ;
- 정정표 (고려대학교 안산병원 영상의학과) ;
- 장상규 (고려대학교 안산병원 영상의학과) ;
- 이현 (고려대학교 안산병원 영상의학과) ;
- 김장섭 (고려대학교 안산병원 영상의학과) ;
- 신동철 (고려대학교 안산병원 영상의학과) ;
- 최종학 (고려대학교 보건과학대학 방사선학과) ;
- 이기성 (고려대학교 보건과학대학 방사선학과) ;
- 이원호 (고려대학교 보건과학대학 방사선학과)
- Published : 2008.06.30
Abstract
The aim of this study is to assess the dose reduction of eye lens and availability of bismuth garments resulting from the use of radioprotective bismuth garments to shield the eyes of patients undergoing head CT. Rando phantom and TLDs were used to determine the amount of dose reduction by bismuth shielding of the eye in the following simulated CT scans : (a) scanning of the head including orbits, (b) scanning of the whole head, and (c)
본 연구는 두부 전산화 단층촬영 시 차폐용 bismuth를 사용하여 수정체 선량의 감소와 차폐용 bismuth의 유용성을 평가하기 위해 수행되었다. 인체모형 팬텀과 열형광 선량계를 이용하여 (a) 안구를 포함한 두부 CT촬영 (b) 두부 전체가 포함된 CT촬영 (c) 안구를 배제하고