• Title/Summary/Keyword: He plasma

Search Result 321, Processing Time 0.025 seconds

Survival after Cardiac Arrest due to Acute Methamphetamine Poisoning: A Case Report (메스암페타민(필로폰) 급성 중독으로 유발된 심정지 후 생존한 1례)

  • Mun, You Ho;Kim, Jung Ho
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.16 no.2
    • /
    • pp.176-180
    • /
    • 2018
  • Drug abuse and its related problems are increasing continuously in Korea. One of the most frequently abused drugs is methamphetamine, but there are few medical report in Korea. This is the first report of the identification of methamphetamine in the blood of a patient who had a return of spontaneous circulation after cardiac arrest and survived discharge. A 33-year-old male arrived at the emergency department presenting with chest pain and dyspnea. He had ingested methamphetamine and alcohol approximately 7 hours before arrival. One hour after arrival, he had seizure followed by cardiac arrest. Spontaneous circulation was recovered after 4 minutes of CPR. An analysis of the National Forensic Service identified plasma methamphetamine with an estimated average concentration of plasma methamphetamine at the time of arrival of 0.6 mg/L, a lethal dose. He had rhabdomyolysis and acute kidney injury but survived after continuous renal replacement therapy. Since then, he has suffered chronic kidney disease, and he is being followed up at the out-patient department. In Korea, although drug abuse is still uncommon, it is on the increase. Therefore, emergency physicians should be aware of the clinical characteristics of methamphetamine poisoning.

The Effects of an RF Plasma and Electric Fields on the Death of G361 Melanoma Cells (RF 플라즈마 및 전기장의 흑색종 (G361 melanoma) 세포에 대한 사멸 효과)

  • Shon, Chae-Hwa;Kim, Gyoo-Cheon;Lee, Hae-June
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1972-1977
    • /
    • 2007
  • Micro plasma has been recently studied to investigate the effects on various cells. We study a micro-plasma produced by a plasma needle that is operated with RF power and its effects on G361 melanoma cells. The micro plasma size ranges from sub-mm to several mm at a few watts of RF power. For the bio-medical treatment, low-temperature plasma is obtained and gas temperature is controlled within several tens of degrees $(^{\circ}C)$ in order not to disturb cell activities. Elementary spectroscopic studies to obtain plasma characteristics are presented for Ar and He plasma with different frequencies of RF power. Also the preliminary results of the micro plasma effects on G361 melanoma cells are presented. It was observed that the irradiation of micro plasma induces cell death through the deprivation of tyrosine phosphorylation in the G361 cells.

Effects of Intravenous He-Ne Laser Irradi on Meridian-Heart·Circulation CMP and Hyperlipidemia (정맥혈관내(靜脈血管內) 헬륨-네온 레이저 조사(照射)가 메리디안 심(心)·순환(循環) 대표점(代表點)과 고지혈증(高脂血症)에 미치는 영향(影響))

  • Ahn, Soo-gi;Lee, Sam-ro;Hwang, Woo-jun
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.1
    • /
    • pp.269-284
    • /
    • 1998
  • The purpose of this study was to investigate the effect of ILIB(Intravenous Laser Irradiation of blood) on Meridian-Heart Circulation CMP and Hyperlipidemia. Circulatory symptom of 20 patients was treated with ILIB. After 10 times' treatment, changes of total cholesterol, HDL-cholesterol, triglyceride and Meridian-Heart Circulation CMP value were observed. The results were as follows : 1. In observation of Meridian-Heart Circulation CMP value, significant increase was observed in both pre-ID generation and post-ID generation. So, distinctive observation between pre-ID generation and post-ID generation became not relatively significant. 2. In observation of Meridian-Heart Circulation CMP value, significant increase was observed in both left and right. So, distinctive observation between left and right became not relatively significant. 3. In observation of Meridian-Heart CMP value, significant increase was not observed in control group, but significant increase close to normal value was observed in treatment group after treatment of Intravenous He-Ne Laser Irradiation. 4. In observation of Meridian-Circulation CMP value, significant increase was not observed in control group, but significant increase close to normal value was observed in treatment group after treatment of Intravenous He-Ne Laser Irradiation. 5. In concentration of plasma total cholesterol and plasma triglyceride, significant decrease was not observed in control group, but significant increase was observed in treatment group after treatment of Intravenous He-Ne laser Irradiation. 6. Significant concentration change of plasma HDL-cholesterol was not observed in both control group and treatment group. From above results, it was thought that Intravenous He-Ne Laser Irradiation was significant effect on heart circulatory system in human body.

  • PDF

Low Plasma Insulin Level Prolonged Hypoglycemia after High dose Insulin Lispro Injection (고용량 Insulin lispro 피하 주사 후 저 인슐린 혈증을 보인 지속적 저혈당성 혼수 환자 1례)

  • Kang, Jeong Ho;Park, Hyun Soo
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.14 no.2
    • /
    • pp.151-154
    • /
    • 2016
  • Increased plasma insulin levels are often observed in exogenous insulin overdose patients. However, plasma insulin level may decrease with time. We report a case of low plasma insulin level hypoglycemia after insulin lispro overdose. The patient was a 37-year-old man with no previous medical history who suspected insulin lispro overdose. Upon arrival, his Glasgow coma scale was 3 points and his blood sugar level (BSL) was 24 mg/dl. We found five humalog-quick-pen (insulin lispro) in his bag. There was no elevation of glucose level, despite an initial 50 ml bolus of 50% glucose and 150 cc/hr of 10% dextrose continuous intravenous infusion. He also suffered from generalized tonic-clonic seizure, which was treated with lorazepam and phenytoin. We conducted endotracheal intubation, after which he was admitted to the intensive care unit (ICU). There were recurrent events of hypoglycemia below BSL<50 mg/dl after admission. We repeatedly infused 50 ml 50% glucose 10 times and administered 1 mg of glucagon two times. The plasma insulin level was 0.2 uU/ml on initial blood sampling and 0.2 uU/ml after 5 hours. After 13 hours, his BSL stabilized but his mental status had not recovered. Diffuse brain injury was observed upon magnetic resonance imaging (MRI) and severe diffuse cerebral dysfunction was found on electroencephalography (EEG). Despite 35 days of ICU care, he died from ventilator associated pneumonia.

Basic study on the gas discharge panel for LCD and PDP (PDP와 LCD에서의 가스방전 페널에 대한 기초연구)

  • Song, Byoung-Doo;Ha, Sung-Chul;Jeon, Byung-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.554-557
    • /
    • 2003
  • This paper describes the information for quantitative simulation of weakly ionized plasma. We should grasp the meaning of the plasma state condition to utilize engineering application and to understand materials of plasma state. In this paper, electron swarm parameter in He+Xe and Ar+He mixture gas calculated for range E/N values $0.01{\sim}500$ [Td] at the temperature is 300 [K] and pressure is 1 [Torr], using a set of electron collision cross sections determined by the authors, and using a method of Backward Prolongation by two term approximation Boltzmann equation method, for basic study on the gas discharge panel.

  • PDF

Research on the Apoptotic Death of Melanoma by the irradiation of Micro Plasma (마이크로 플라즈마를 이용한 피부암 세포의 자연사 유도 연구)

  • Shon, C.H.;Kim, G.C.;Lee, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.220-221
    • /
    • 2007
  • Micro plasma has been recently studied to investigate the effects on various cells. We study a micro-plasma produced by a plasma needle that is operated with RF power and its effects on G361 melanoma cells. The micro plasma size ranges from sub-mm to several mm at a few watts of RF power. For the bio-medical treatment, low-temperature plasma is obtained and gas temperature is controlled within several tens of degrees $(^{\circ}C)$ in order not to disturb cell activities. Elementary spectroscopic studies to obtain plasma characteristics are presented for Ar and He plasma with different frequencies of RF power. Also the preliminary results of the micro plasma effects on G361 melanoma cells are presented. It was observed that the irradiation of micro plasma induces cell death through the deprivation of tyrosine phosphorylation in the G361 cells.

  • PDF

Reduction of Temporal Image Sticking in AC Plasma Display Panels through the Use of High He Contents

  • Park, Choon-Sang;Kim, Sun-Ho;Kim, Jae-Hyun;Tae, Heung-Sik
    • Journal of Information Display
    • /
    • v.10 no.4
    • /
    • pp.195-201
    • /
    • 2009
  • The temporal dark- and bright-image sticking phenomena were examined relative to the He contents under 11% Xe content in the 50-in HD and FHD AC-PDPs with a ternary gas mixture (Xe-He-Ne). To compare the temporal dark- and bright-image sticking phenomena under various He contents, the differences in the disappearing time, display luminance, perceived luminance, infrared emission, color coordinate, color temperature, and discharge current before and after discharge were measured under 0, 35, 50, and 70% He contents. It was found that temporal dark- and bright-image sticking were reduced in proportion to the increase in He %. Thus, a high He content contributes to the reduction of temporal dark- and bright-image sticking.

The Analysis of the He-Ne-Xe Gas Discharge Characteristics in an AC Plasma Display Panel by Two Dimensional Simulation

  • Seo, Jeong-Hyun;Chung, Woo-Joon;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.27-28
    • /
    • 2000
  • We examined ($He_x-Ne_{l-x}$)-Xe gas discharge in an AC PDP cell by computer simulation to understand the gas mixing effects. The breakdown and sustain voltage were significantly lowered with the addition of Ne into He-Xe. The luminance and efficiency in ($He_x-Ne_{l-x}$)-Xe also improved when compared with the He-Xe or Ne-Xe gas mixture. The luminance is maximum around $30{\sim}40%$ He addition, while the efficiency shows peak values at 70% He. Two-dimensional numerical simulation was done to explain these results.

  • PDF

Phase formation and microstructural characteristics of ytterbium silicates coatings fabricated by plasma spraying with Ar/He gas compositions for environmental barrier coating applications (플라즈마용사로 증착된 환경차폐코팅 이터븀 실리케이트의 Ar/He 가스 조성에 따른 상형성 및 미세구조 특성)

  • Choi, Jae-Hyeong;Kim, Seongwon;Kim, Ji-Yoo;Moon, Hung Soo
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.6
    • /
    • pp.376-382
    • /
    • 2022
  • Yb2Si2O7 has a coefficient of thermal expansion similar to that of the base material of SiC and has excellent corrosion resistance in a high-temperature oxidizing atmosphere including water vapor, so it is being studied as one of the materials for environmental barrier coatings (EBCs). In this study, Yb2Si2O7 powder granule is deposited using atmospheric plasma spraying (APS) with different Ar/He ratios. Phase formation and microstructural characteristics are investigated with the coated specimens. In the coating layer, the crystallinity decreased, and the amorphous content increased from an increase in the ratio of Ar. In addition, the various types of particles involved by local volatilization of Si according to the Ar/He ratios were identified.

Low Temperature Growth of MCN(M=Ti, Hf) Coating Layers by Plasma Enhanced MOCVD and Study on Their Characteristics (플라즈마 보조 유기금속 화학기상 증착법에 의한 MCN(M=Ti, Hf) 코팅막의 저온성장과 그들의 특성연구)

  • Boo, Jin-Hyo;Heo, Cheol-Ho;Cho, Yong-Ki;Yoon, Joo-Sun;Han, Jeon-G.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.563-575
    • /
    • 2006
  • Ti(C,N) films are synthesized by pulsed DC plasma enhanced chemical vapor deposition (PEMOCVD) using metal-organic compounds of tetrakis diethylamide titanium at $200-300^{\circ}C$. To compare plasma parameter, in this study, $H_2$ and $He/H_2$ gases are used as carrier gas. The effect of $N_2\;and\;NH_3$ gases as reactive gas is also evaluated in reduction of C content of the films. Radical formation and ionization behaviors in plasma are analyzed in-situ by optical emission spectroscopy (OES) at various pulsed bias voltages and gas species. He and $H_2$ mixture is very effective in enhancing ionization of radicals, especially for the $N_2$. Ammonia $(NH_3)$ gas also highly reduces the formation of CN radical, thereby decreasing C content of Ti(C, N) films in a great deal. The microhardness of film is obtained to be $1,250\;Hk_{0.01}\;to\;1,760\;Hk_{0.01}$ depending on gas species and bias voltage. Higher hardness can be obtained under the conditions of $H_2\;and\;N_2$ gases as well as bias voltage of 600 V. Hf(C, N) films were also obtained by pulsed DC PEMOCYB from tetrakis diethyl-amide hafnium and $N_2/He-H_2$ mixture. The depositions were carried out at temperature of below $300^{\circ}C$, total chamber pressure of 1 Torr and varying the deposition parameters. Influences of the nitrogen contents in the plasma decreased the growth rate and attributed to amorphous components, to the high carbon content of the film. In XRD analysis the domain lattice plain was (111) direction and the maximum microhardness was observed to be $2,460\;Hk_{0.025}$ for a Hf(C,N) film grown under -600 V and 0.1 flow rate of nitrogen. The optical emission spectra measured during PEMOCVD processes of Hf(C, N) film growth were also discussed. $N_2,\;N_2^+$, H, He, CH, CN radicals and metal species(Hf) were detected and CH, CN radicals that make an important role of total PEMOCVD process increased carbon content.