• Title/Summary/Keyword: Hankel approximation

Search Result 20, Processing Time 0.026 seconds

AN APPROXIMATION OF THE HANKEL TRANSFORM FOR ABSOLUTELY CONTINUOUS MAPPINGS

  • DRAGOMIR, N.M.;DRAGOMIR, S.S.;GU, M.;GAN, X.;WHITE, R.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.6 no.1
    • /
    • pp.17-31
    • /
    • 2002
  • Using some techniques developed by Dragomir and Wang in the recent paper [2] in connection to Ostrowski integral inequality, we point out some approximation results for the Henkel's transform of absolutely continuous mapping.

  • PDF

Reduced order controller using J-lossless coprime factorization and balanced transformation (J-lossless 소인수분해와 균형화된 변환을 이용한 제어기 차수줄임)

  • 오도창;정은태;엄태호;박홍배
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.1018-1023
    • /
    • 1992
  • In this paper we proposed the systematic method of reducing the order of controller with robustness. State space formulae for all controllers is found by solving two coupled J-lossless coprime factorizations and model reduction problem. To reduce the order of controller, balanced truncation and Hankel approximation are used.

  • PDF

DISCRETE MODEL REDUCTION OVER DISC-TYPE ANALYTIC DOMAINS AND $\infty$-NORM ERROR BOUND

  • Oh, Do-Chang;Lee, Kap-Rai;Um, Tae-Ho;Park, Hong-Bae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.64-68
    • /
    • 1996
  • In this note, we propose the discrete model reduction method over disc-type analytic domains. We define Hankel singular value over the disc that is mapped by standard bilinear mapping. And GSPA(generalized singular perturbation approximation) and DT(direct truncation) are generalized to GSPA and DT over a disc. Furthermore we show that the reduced order model over a smaller domain has a smaller L$_{\infty}$ norm error bound..

  • PDF

Discrete model reduction over disc-type analytic domains (디스크형태의 해석적영역을 가지는 이산모델 차수축소)

  • 오도창;정은태;이갑래;박홍배
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.5
    • /
    • pp.27-34
    • /
    • 1998
  • This paper is on the discrete model reduction method over disc-type analytic domains. We define hankel singular value over the disc that is mapped by standard bilinear mapping. And the generalized singular perturbation approximation and the direct truncation are generalized to GSPA and DT over a disc. Furthermore, it is shown that the reduced order model over a smaller domaing has a smaller .inf.-norm error bound. And the poposed reduction method is used to obtain the regional pole placement property.

  • PDF

(Frequency Weighted Reduction Using Iterative Approach of BMI) (BMI의 반복적 해법을 이용한 주파수하중 차수축소)

  • Kim, Yong-Tae;O, Do-Chang;Park, Hong-Bae
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.1
    • /
    • pp.33-41
    • /
    • 2002
  • In this paper, we present a frequency weighted model reduction using LMIs for minimizing the H$\infty$ weighted model error compared with the methods of frequency weighted balanced truncation and frequency weighted Hankel norm approximation. The proposed algorithm, its form is equal to the sufficient condition of performance preserving controller approximation, is based on an iterative two-step LMI scheme induced from bound real lemma. So, it can be applied to the problem of the performance preserving controller approximation. The controller reduction is useful in a practical control design and ensures its easy implementation and high reliability The validity of the proposed algorithm is shown through numerical examples. Additionaly, we extend the proposed algorithm to performance preserving controller approximation by applying to the HIMAT(highly maneuverable aircraft technology) system.

Approximation of Pulse Transfer Function of Impulse Response Data (임펄스응답 데이타의 펄스전달함수의 근사)

  • Lee, Dong-Cheol;Bae, Jong-Il;Chung, Hyeng-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.683-685
    • /
    • 1999
  • As a method of obtaining pulse transfer function. transfer function of discrete-time from input-output data, there are method of obtaining unknown parameter of pulse transfer function from estimated impulse response before(1-3). There is no need to approximate to several meanings because of not being established algebraical relations between impulse response for estimation error and parameter of transfer function exactly. In this paper, I inquire the method[4] of obtaining the optimal pulse transfer function as a meaning of Hankel norm approximation from impulse response data and examine estimated property as computer simulation from this method.

  • PDF

Uncertainties and control of a 3-DOF active vibration isolation system (3자유도 능동형 제진 시스템의 불확실성과 제어)

  • Kim, Hwa-Soo;Pahk, Heui-Jae;Moon, Jun-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.925-933
    • /
    • 2006
  • Using the physics-based model for the vibration isolation system, the model uncertainties are described. With the model including parameter perturbations, the robust controller to meet the robust performance and stability is designed through $\mu$-synthesis by DK-iteration. The order of controller is reduced by virtue of Hankel norm approximation technique to allow the efficient implementation in the real-time experimental environment without any performance degradation. The performance of the reduced $\mu$-controller is accessed in comparison with the original one. The experiments validate the superiority of the proposed control scheme against the model uncertainties and its applicability with varying payload.

  • PDF

Analysis of Wide Band Annular Ring Microstrip Patch Antenna (광대역 Annular Ring 마이크로스트립 패치 안테나의 해석)

  • Seo, Chul-Hun;Kim, Hyeong-Seok
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.2 no.1
    • /
    • pp.13-21
    • /
    • 2003
  • This paper presents the analysis of the mode characteristics of an annular ring microstrip patch antenna for circular polarization with attachment mode using method of moments in the spectral domain. For a probe excitation, the input impedance are obtained by using the single mode approximation for both the $TM_{11}$ and $TM_{12}$ modes and compared with those by Vector Hankel Transform. While the $TM_{11}$ mode has a high Q, it is a poor radiating mode; the $TM_{12}$ mode is more suitable for antenna applications. It is also shown that the bandwidth of the $TM_{12}$ mode is wider than that of the $TM_{11}$ mode in terms of axial ratio for circular polarizatio

  • PDF

Uncertainties and Control of a 3-DOF Active Vibration Isolation System (3자유도 능동형 제진 시스템의 불확실성과 제어)

  • Kim, Hwa-Soo;Pahk, Heui-Jae;Cho, Young-Man;Moon, Jun-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.12 s.117
    • /
    • pp.1262-1271
    • /
    • 2006
  • Using the physics-based model for the vibration isolation system, the model uncertainties are described. With the model including parameter perturbations, the robust controller to meet the robust performance and stability is designed through $\mu$-synthesis by DK-iteration. The order of controller is reduced by virtue of Hankel norm approximation technique to allow the efficient implementation in the real-time experimental environment without any performance degradation. The performance of the reduced $\mu$-controller is accessed in comparison with the original one. The experiments validate the superiority of the proposed control scheme against the model uncertainties and its applicability with varying payload.

H^$\infty$ Controller Design Based on NLCF Models: A Unified Approach for Continuous and Discrete Systems

  • Youn, Sang-Soon;Kwon, Oh-Kyu
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.3
    • /
    • pp.306-315
    • /
    • 1998
  • In this paper, a unified approach to the H\ulcorner controller design is proposed under the $\delta$-form for both continuous and discrete systems. Most of important basic concepts of H\ulcorner control, such as inner, co-inner, GCARE and GFARE, are reformulated by the unified form. The NLCF(Normalized left Comprime Factor) plant description has been reviewed in the $\delta$-form, and some corresponding results are proposed. And the unified H\ulcorner controller is designed which is based on the McFarlane and Glover{1]. The state-space parameterization for all suboptimal controllers is given under the NLCF model which may not be strictly proper, and the central controller is derived by using the solution to Hankel norm approximation problem[2]. The unified controller is applied to the industrial boiler control problem to exemplify the performance of the controller.

  • PDF