• 제목/요약/키워드: Half-Bridge Inverter

검색결과 260건 처리시간 0.024초

A CW $CO_2$ Laser Using a High Voltage Dc-dc Converter with Half-bridge Resonant Inverter and Cockroft-Walton Multiplier

  • Chung, Hyun-Ju;Joung, Jong-Han;Kim, Geun-Young;Min, Byoung-Dae;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권4호
    • /
    • pp.123-129
    • /
    • 2003
  • We propose a high voltage dc-dc converter for a CW (continuous wave) $CO_2$ laser system using a current resonant half-bridge inverter and a Cockcroft-Walton circuit. This high voltage power supply includes a 2-stage voltage multiplier driven by a regulated half-bridge series resonant inverter. The inverter drives a step-up transformer and the secondary transformer is applied to the voltage multiplier. It is highly efficient because of the reduced amount of switching losses by virtue of the current resonant half-bridge inverter, and also due to the small size, low parasitic capacitance in the transformer stage owing to the low number of winding turns of the step up secondary transformer combined with the Cockroft-Walton circuit. We obtained a maximum laser output power of 44 W and a maximum system efficiency of over 16%.

냉장고의 선형압축기 구동을 위한 단상 하프브리지 인버터 시스템에서 직류단 불평형 보상에 관한 연구 (DC Voltage Balancing Control of Half-Bridge PWM Inverter for Liniear Compressor of Refrigerator)

  • 김호진;김형진;김동윤;김장목
    • 전력전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.256-262
    • /
    • 2017
  • This paper presents the control algorithm of a single-phase AC/DC/AC PWM converter for the linear compressor of a refrigerator. The AC/DC/AC converter consists of a full-bridge PWM converter for the control of the input power factor and a half-bridge PWM inverter for the control of the single-phase linear compressor. At the DC-link of this topology, two capacitors are connected in series. These DC-link voltages must be balanced for safe operation. Thus, a new control method of DC voltage balancing for the half-bridge PWM inverter is proposed. The balancing algorithm uses the Integral-Proportional controller and inserts the DC-offset current at the Proportional-Resonant current controller of the inverter to solve the DC-link unbalanced voltages between the two capacitors. The proposed algorithm can be easily implemented without much computation and additional hardware circuit. The usefulness of the proposed algorithm is verified through several experiments.

Half-Bridge ZCS resonant inverter 및 Cockroft-Walton회로를 사용한 공기 청정기에 관한 연구 (ESP by using Half-bridge ZCS resonant inverter and Cockroft-Walton circuit)

  • 박종웅;정종진;정현주;정종한;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1951-1953
    • /
    • 2004
  • In this study, we propose a small high voltage power supply which use a half-bridge ZCS resonant and Cockroft-Walton on circuit, for ESP (Electrostatic Precipitator). This power supply transfers energy from ZCS resonant inverter to step-up transformer and the transformer secondary is applied to the Cockroft-Walton circuit for generating high voltage as discharging source of electrodes. It is highly efficient because its amount of switching losses are reduced by virtue of the current resonant half-bridge inverter, and also due to the small size, low parasitic capacitance in the transformer stage owing to the low number of winding turns of the step up transformer secondary combined with the Cockroft-Walton circuit. From these results, the best operational condition is obtained at the switching frequency of 9 kHz and the duty ratio of 50 % in this ESP.

  • PDF

Compensation of Current Offset Error in Half-Bridge PWM Inverter for Linear Compressor

  • Kim, Dong-Youn;Im, Won-Sang;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1593-1600
    • /
    • 2015
  • This paper proposes a novel compensation algorithm of current offset error for single-phase linear compressor in home appliances. In a half-bridge inverter, current offset error may cause unbalanced DC-link voltage when the DC-link is comprised of two serially connected capacitors. To compensate the current measurement error, the synchronous reference frame transformation is used for detecting the measurement error. When an offset error occurs in the output current of the half-bridge inverter, the d-axis current has a ripple with frequency equal to the fundamental frequency. With the use of a proportional-resonant controller, the ripple component can be removed, and offset error can be compensated. The proposed compensation method can easily be implemented without much computation and additional hardware circuit. The validity of the proposed algorithm is verified through experimental results.

Design of a Single-stage Electronic Ballast using a Half-Bridge Resonant Inverter

  • Son, Young-Dae
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권3호
    • /
    • pp.104-111
    • /
    • 2001
  • The design procedures and experimental results of a single-stage electronic ballast using half-bridge resonant inverter are presented in this paper. The proposed topology is based on a single-stage ballast which combines a boost converter and a half-bradge series resonant inverter. High power factor is achieved by using the boost semi-stage operating in discontinuous conduction mode and inverter semi-stage operated above resonant frequency to provide zero voltage switching is empolyed to ballast the fluorescent lamp Experimental results from the ballast system with 36W fluorescent

인터리브드 풀 브릿지 컨버터와 단상 하프 브릿지 인버터를 이용한 1.5kW급 PCS 설계 (Design of 1.5kW PCS Using Interleaved Full-Bridge Converter and Single Phase Half-Bridge Inverter)

  • 나광수;나종국;이희준;신수철;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.403-404
    • /
    • 2013
  • In this paper, a PCS which consists of high boost interleaved full-bridge converter and single phase half-bridge inverter is proposed. Proposed PCS is using two full bridge converter modules. PCS consists of parallel input / serial output. It can reduce turn ratio of high frequency transformer. In this paper, PCS which is using 1.5[kW] interleaved full-bridge converter and single phase half bridge inverter is designed and verified stability of system through experiment.

  • PDF

IsSPICE를 이용한 400[W] 고압나트륨 램프용 전자식 안정기 설계 (A Design of Electronic Ballast for 400[W] High Pressure Sodium Lamp Using IsSPICE)

  • 강응석;신대철;최종문
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.27-34
    • /
    • 2004
  • 본 논문에서는 half-bridge inverter를 이용하여 400[W] 고압나트륨 램프용 전자식 안정기를 설계하였다. 제안된 등가 LC 직렬 공진회로에서 인덕터와 커패시터의 값을 이론적으로 계산하고, LC 직렬 half-bridge 회로에 대한 IsSPICE 시뮬레이션을 수행하였다. 계산결과를 검증하기 위해 전자식 안정기를 설계 제작하여 실험을 수행하였다. 실험에 의한 전자식 안정기의 제반특성은 시뮬레이션 결과와 대단히 유사하였다. 실험결과 출력전압 400[W]에서 역률 99.3[%], 전류 전고조파 10.01[%], 램프효율 119[lm/W]의 좋은 성과를 나타내었다.

부하 환류모드를 제공하는 새로운 반 브리지 인버터의 손실해석 (Loss analysis for the novel half bridge inverter with load free-wheeling mode)

  • 연재을;조규민;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.216-219
    • /
    • 2003
  • The resonant inverter is widely used for induction heating, electronic ballast and supersonic motor driving circuit. In the meantime, control techniques of PWM, PFM etc.. are mainly applied to control the output power of the resonant inverter. But, in the case of using the half bridge resonant inverter, it is difficult to control the output power by PWM, because its main circuit does not provide the load free-wheeling mode. Therefore, PAM or PFM was usually applied to control output power of half bridge resonant inverter. However, PAM needs a variable DC voltage source, which makes the system structure more complex. On the other hand, in case of PFM, efficiency is declined by operation with poor power factor. This paper Proposed the novel half bridge resonant inverter which can provide the load free-wheeling mode. Also its analysis results for PWM operation with unity fundamental power factor are Presented and compared with other resonant inverters using PWM and PFM.

  • PDF

넓은 범위의 ZVS동작을 갖는 LCD Backlight 구동용 Dual Half Bridge Inverter (Zero Voltage Switching(ZVS) Dual Half-Bridge Inverter with Wide Input Voltage Range for LCD Backlight Driver)

  • 정영진;한상규;노정욱;홍성수;사공석진;권기현;이효범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.144-146
    • /
    • 2007
  • 본 논문에서는 고효율 LCD Backlight 구동을 위해 주로 사용하던 Phase shift Full bridge 방식을 대신할 수 있는 Dual Half Bridge Inverter를 제안하였다. 제안된 회로는 일반적인 Push-Pull 인버터 구동용 제어 IC의 출력 신호 2개로 스위치 4개를 제어할 수 있으며 넓은 범위의 ZVS(zero voltage switching)을 보장하여 소자 발열 및 효율 상승의 이점을 가진다. 제안된 Inverter Topology를 소개하며 동작모드 해석과 시뮬레이션 및 실험을 통한 검증결과를 제시 한다.

  • PDF

유도가열 시스템을 위한 새로운 전류형 풀-브릿지 공진형 인버터 설계 (Design of New Current Full-Bridge Resonant Inverter for Induction Heating System)

  • 이상훈;임상길;송성근
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.59-69
    • /
    • 2012
  • There are two types of inverters that are generally used in induction heating systems: voltage type inverters and high-frequency half-bridge inverters. This paper proposes a new resonant inverter for induction heating systems using the current type full-bridge method. The proposed method can remove capacitors at the input end, and enables unity power factor operation by preventing phase differences of voltage and current. Furthermore, Zero Voltage Switching (ZVS) which is in tune with current type inverter can be adopted and continuous power adjustment is possible through duty ratio changes and frequency modulation in switching operation. Simulations and experiments showed that the proposed current type full-bridge resonant inverter could be used for unity power factor control and ZVS operation in induction heating systems.