• Title/Summary/Keyword: Half value thickness

Search Result 75, Processing Time 0.023 seconds

Numerical analysis of natural convection heat transfer from a fin in parallel enclosure

  • Bae, Myung-Whan;Mochimaru, Yoshihiro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.5
    • /
    • pp.412-417
    • /
    • 2016
  • A fin of finite width with infinitely small thickness is assumed to be placed horizontally between two horizontal parallel plates of infinite extension in the exactly central position. The lower plate and the half of the upper plate are kept at a constant lower temperature, and the remaining upper plate is kept at a constant higher temperature. The fin is also kept at a constant temperature (variable). Steady-state two-dimensional laminar natural convection is analyzed as a problem of boundary value under a boundary-fitted conformal mapping system, using a spectral finite difference scheme, with a condition of doubly-connectedness. The steady-state solution is obtained as a limit of the transient solution.

Analysis and Design of half-mirror coating for sunglasses (썬글라스용 반미러(Half-Mirror) 코팅의 분석과 설계)

  • Park, Moon-Chan;Jung, Boo-Young;Hwangbo, Chang-Kwon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.111-117
    • /
    • 2003
  • We collected the domestic and foreign half-mirror coating lens for sunglasses. Their reflectance is measured using Spectrophotometer in order to analysis their optical property and the result which is calculated using Macleod program was compared with measured reflectance. In addition, we designed the new half-mirror coating lens with gold color using TiN material and investigated the optical property of the new half-mirror coating lens. The results obtained from analysis of half-mirror coating lenses are as follow : Two-tone half-mirror coating with silver color is fabricated with [air|$SiO_2$(or $Al_2O_3$)|Cr|glass]. The role of $SiO_2$(or $Al_2O_3$) on Cr improve the hardness of the lens and the thickness of the $Al_2O_3$ with 10 nm is good to show the lens silver color. Incase of color half-mirror coating lens. Blue system is designed by [air|$SiO_2$(66.3)|$TiO_2$(129.0)|$SiO_2$(62.9)|$SiO_2$(26.0)|$TiO_2$(120.3)|$SiO_2$(9.1)|glass], gold system [air|$SiO_2$(60.6)|$TiO_2$(86.2)|$SiO_2$(13.5)|$TiO_2$(86.8)|$SiO_2$(214.38)|glass], green system[air|$SiO_2$(74.3)|$TiO_2$(75.8)|$SiO_2$(44.3)|$TiO_2$(11.6)|$SiO_2$(160.8)|$TiO_2$(12.9)|$SiO_2$(183.3)|$TiO_2$(143.8)|glass], silver system[air|$SiO_2$(21.2)|$TiO_2$(49.7)|$SiO_2$(149.3)|glass]. White half-mirror coating lens has [air|$SiO_2$(17 nm)|$TiO_2$(43 nm)(or $ZrO_2$)|$SiO_2$(87 nm)|polysiloxane($4.46{\mu}m$|glass or CR-19]. It has half-mirror coaling lens which has about 19% reflectance and about 80% transmittance in the range of visible light(400~700nm). we designed the new half-mirror coating lens with gold color, the (x, y) value of the CIE is almost similar to the CIE value of [air|$SiO_2$(170 nm)|TiN(15 nm)|glass].

  • PDF

Synthesis of barium-doped PVC/Bi2WO6 composites for X-ray radiation shielding

  • Gholamzadeh, Leila;Sharghi, Hamed;Aminian, Mohsen Khajeh
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.318-325
    • /
    • 2022
  • In this study, composites containing undoped and barium-doped Bi2WO6:Ba2+were investigated for their shielding against diagnostic X-ray. At first, Bi2WO6 and barium-doped Bi2WO6 were synthesized with different weight percentages of barium oxide through a hydrothermal process. The as-synthesized nanostructures were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS) and Raman spectroscopy (RS). After that, some shields were generated with undoped and barium-doped Bi2WO6:Ba2+ nanostructure particles incorporated into polyvinyl chloride (PVC) polymer with different thicknesses and 15% weight of the nanostructure. Finally, the prepared samples were exposed to an X-ray tube at 40, 80, and 120 kV voltages, 10 mAs and, 44.5 cm SID (i.e. the distance from the X-ray beam source to the specimen). Linear and mass attenuation coefficients were also calculated for different samples. The results indicated that, among the samples, the one with 7.5 mmol barium-doped Bi2WO6 had the most attenuation at the voltage of 40kV, and the attenuation coefficients would increase with an increase in the amount of barium. The samples with 15 and 17.5 mmol barium-doped Bi2WO6 had higher attenuation than the others at 80 and 120 kV. Moreover, the half-value layer (HVL), tenth-value layer (TVL) and 0.25 mm lead equivalent thickness were calculated for all the samples. The lowest HVL value was for the sample with 7.5 mmol barium-doped Bi2WO6. As the result clearly show, an increment in the barium-doping content leads to a decrease in both HVL and TVL. In every three voltages, 0.25 mm lead equivalent thickness of the barium-doped composites (7.5 mmol and 15 mmol) had less than the other composites. The lowest value of 0.25 mm lead equivalent thickness was 7.5 barium-doped in 40 kV voltage and 15 mmol barium-doped in 80 kV and 120 kV voltages. These results were obtained only for 15% weight of the nanostructure.

Patient Dose in Mammography (유방촬영에서 환자 피폭선량)

  • Shin, Gwi-Soon;Kim, You-Hyun;Kim, Jung-Min;Kim, Chang-Kyun;Yang, Jeong-Hwa;Choi, Jong-Hak
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.293-299
    • /
    • 2005
  • In the present investigation, we analyzed the data of 1,318 patients (2,636 images) who underwent mammographic examinations and obtained the distribution of the patient age and compressed breast thickness. We measured also average glandular doses (AGD) as function of compressed breast thickness. In order to obtain the values of AGD, we measured half value layer (HVL) and tube output (mR/mAs) for each kVp and target/filter combination. Entrance surface air kerma (ESAK) was calculated from the tube output as measured for each voltage used under clinical conditions and from the tube loading (mAs). AGD per exposure were calculated by multiplying the ESAK values by the conversion factors tabulated by Dance. We obtained in this study the following conclusions. The mean value of compressed breast thickness for cranio-caudal (CC) view was 35.8mm and that for medio-lateral oblique (MLO) view was 43.3 mm. The mean value of AGD for CC view was 1.55 mGy and that for MLO view was 1.70 mGy. The AGD for MLO view was 0.15 mGy (10%) higher than that for CC view because the thickness for MLO view was on average 4.8 mm higher than that for CC view. The values of AGD increased with increasing compressed brest thickness. The increased AGD value was on average 0.34 mGy per 10 mm in the thickness ranges $10{\sim}80\;mm$, therefore differences between the AGD values of each thickness were relative large. Thus, it is considered to need limited doses for mammography with the upper end of exposure range at several different compressed brest thickness.

  • PDF

Equivalent Circuit Parameters of S-band 1.5 Cell RF Gun Cavity

  • Kim, Ki-Young;Kang, Heung-Sik;Tae, Heung-Sik
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.1
    • /
    • pp.30-36
    • /
    • 2004
  • We determined equivalent circuit parameters of a 1.5 cell S-band RF gun cavity from the resonant characteristics of its decoupled cavities(half cell and full cell) using the code SUPERFISH. Equivalent circuit parameters of the 1.5 cell RF gun cavity resonated in the 0-mode were obtained easily from the circuit parameters of each decoupled cavities. In order to obtain equivalent circuit parameters for the $\pi$ -mode cavity, we calculated the differences of the resonant frequencies and the equivalent resistances between the 0- and $\pi$ -modes with slight variations of the radius and thickness of the coupling iris. From those differences, we obtained R/Q value and equivalent resistance of the $\pi$ -mode, which are directly related to the equivalent circuit parameters of the coupled cavity. Using calculated R/Q value, we can express equivalent inductance, capacitance and resistances of the RF gun cavity resonated in the $\pi$ -mode, which can be useful for analyzing coupled cavities in a steady state.

Impacts of siltstone rocks on the ordinary concrete's physical, mechanical and gamma-ray shielding properties: An experimental examination

  • R.S. Aita;K.A. Mahmoud;H.A. Abdel Ghany;E.M. Ibrahim;M.G. El-Feky;I.E. El Aassy
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2063-2070
    • /
    • 2024
  • A series of ordinary concrete is casted in order to examine the influence of the manganiferous siltstone rocks on the physical, mechanical, and gamma-ray shielding properties. Thus, a partial replacement for the coarse aggregates by siltstone rocks was performed during the fabrication of the currently ordinary concrete. The test revealed that raising the siltstone concentration improved the mechanical characteristics and density of the developed concretes. The addition of siltstone rocks at concentrations ranging from 0 to 40 wt% of the coarse aggregate concentration raises the density of the concrete from 2.05 g/cm3 to 2.3 g/cm3. Furthermore, partial substitution of basalt with siltstone rocks improves gamma-ray shielding properties. The experimental results for the linear attenuation coefficient show an increase in its value from 0.146 cm1 to 0.160 cm-1 when the siltstone concentration is increased between 0 and 40 wt% at 0.662 MeV. Furthermore, increasing the concentrations of siltstone affected the half-value thickness, which varied between 4.759 and 4.319 cm at 0.662 MeV. Therefore, the replacement presents a new alternative coarse aggregate that can enhance the mechanical and radiation shielding properties of ordinary concretes.

The design and the analysis of a LED illumination lens using the overlapped model (중첩모델을 이용한 조명용 LED 렌즈설계 및 분석)

  • You, Ilhyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.157-164
    • /
    • 2017
  • In this research, the overlapped illumination model was used for designing a freeform LED lens with a uniform illuminance distribution on its illuminating plane, and their performances and tolerances were compared. And, the illuminations on a illumination plane was measures for change with average illuminance and illuminance uniformity. As a result of the tolerance analysis about z-axis direction change, thickness change in lens and tilt change of light emission and characteristic change in LED source, overlapped model and divergent illumination model are similar to the performance about Z-axis direction change of light emission in LED source. but the uniformity illumination value in this overlapped model is more remarkably value than it in divergent illumination model about thickness change in LED lens. Also, even though the lens based on a divergent illumination model showed good performance compare to the lens based on an overlapped illumination model, the latter was less the deviation to variation of LED beam radiation ability.

A Study on Body Type Characteristics of Chinese-Korean Women between 15 and 17 Years Old Living in China (중국 거주 조선족 15-17세 여성의 체형특성 연구)

  • Im, Soon;Kim, Sang-Hee
    • Journal of the Korean Society of Costume
    • /
    • v.61 no.3
    • /
    • pp.97-110
    • /
    • 2011
  • In this study, the characteristics of body type of Chinese-korean Women between 15 and 17 Years Old Living in China were reviewed by analysing factors and groups in order to provide basic data required to research body types. The following are study results. 1. The study examined average, standard deviation, the minimum value and the maximum value of the 72 items gained from measuring Chinese-korean women between 15~17 years old living in China, and found that 21 items showed more than 4.0 standard deviation among the entire measurements. 2. The current study conducted a factor analysis for the 72 items in order to extract and compare components of body types among Chinese-korean women between 15~17 years old living in China. As a result, 9 factors were extracted, and characteristic values were ranged from 1.15 to 24.71 while the accumulated contributory rate was 75.98%. 3. Chinese-korean women between 15 and 17 years old living in China were classified into three types. Among the 72 items, it was observed that there were differences among groups in 64 items including 15 height items, 10 width items, 16 circumference items, 5 thickness items, 17 length items and weight, excluding neck width, head thickness, shoulder angle, head height, face length, waist back length, scye depth and waist to kip length. 4. As a result of proportion comparison using body indexes of Korean women between 15 and 17 years old living in China and Korea, it was found that, in height item, when regarding the height as 100, Korean women between 15 and 17 years old living in China tended to have longer lower half of the body in relation to the height compared to the Korean.

A Study of Radiation Dose and Quality by Using Added Filtration in Chest Radiography (흉부(胸部) X선촬영시(線撮影時) 부가여과사용(附加濾過使用)에 따른 선양(線量)과 선질(線質)에 관(關)한 연구(硏究))

  • You, Byung-Hun;Chu, Sung-Sil;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.10 no.1
    • /
    • pp.13-23
    • /
    • 1987
  • Author has studied for finding the method of decreasing the radiation dose and increasing diagnostic range in chest X-ray radiography. The study for the added filter thickness from half value layer to 1/8 value layer by decreasing curve and research for the exposure factors, decreasing ratio of radiation dose, ratio of scatter ray and image quality in chest X-ray radiography. The results were as follows: 1. By using the rare earth intensifying screen system at 120 Kvp, the sensitivity is increased by times and the exposure ratio is decreased 0.22 by comparison with the $CaWO_{4}$ intensifying screen system at 80 Kvp. 2. By using Al added filter of 1/8 value layer, the scatter ray is increased more than no filter, But the scatter ray is decreased more in $G_{4}/RxOG$ intensifying system than in LT-II/Rx intensifying system. 3. At 120 Kvp, the image quality value of $G_{4}/RxOG$ system is increased more than LT-II/Rx system compared with slight decreasing image quality value at 80 Kvp. Concluded that by using the added filter could decrease the radiation dose by 1/3 and obtain effective image quality with the added filter at high voltage hard exposure.

  • PDF

Computerized Tomographic Measurements of Morphometric Parameters of the C2 for the Feasibility of Laminar Screw Fixation in Korean Population

  • Kim, Young-June;Rhee, Woo-Tack;Lee, Sang-Bok;You, Seung-Hoon;Lee, Sang-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.1
    • /
    • pp.15-18
    • /
    • 2008
  • Objective : C2 laminar screw fixation is considered as an excellent alternative to Magerl's transfacetal approach or Harms construct for the atlantoaxial stabilization. However, to our knowledge, there is no report on the feasibility of the new approach to Korean population. We investigated morphometric parameters of the dorsal arch of the C2 to provide the quantitative data for the feasibility of laminar screw fixation. Methods : One-hundred-and-two patients' cervical computed tomography had been reconstructed and investigated on the anatomical parameters related with C2 laminar screw placement. Sixty patients were male and forty-two patients were female. Measurements included the laminar thickness and slope, spino-laminar angle, and maximal screw length. Results : Ages ranged from 20 to 81 and the mean age was 48.4. Mean laminar thickness was 5.7 mm (${\pm}1.0$) (5.8 mm in male and 5.4 mm in female). Fifty-one patients (50%) had a laminar thickness smaller than 5.5 mm at least unilaterally, therefore the patients were considered as inappropriate candidates for the laminar screw fixation in the smaller side of the laminae. Mean value of maximal length of screw was 33.3 mm (34.3 mm in male and 31.9 mm in female). Mean spino-laminar angle was $43.2^{\circ}$ and mean slope angle was $32.9^{\circ}$. Conclusion : Half of patients had inappropriate laminar profiles to accommodate a 3.5 mm screw in at least one side of the axis. The three-dimensional computed tomography reconstruction is mandatory for the preoperative assessment for the feasibility of the C2 lamina.