• Title/Summary/Keyword: Habitat conditions

Search Result 432, Processing Time 0.022 seconds

Effect of rearing season, host plants and their interaction on economical traits of tropical tasar silkworm, Antheraea mylitta Drury- an overview

  • Bhatia, Narendra Kumar;Yousuf, Mohammad
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.29 no.1
    • /
    • pp.93-119
    • /
    • 2014
  • Tropical tasar silkworm, Antheraea mylitta (Lepidoptera: Saturniidae) is a polyphagous silk producing forest silkworm of commercial importance in India. Forest dependent people rear its larvae on different forestry host plants twice or thrice in a year for small household income. Larvae of A. mylitta feeds on many forest tree species, but always show a great degree of selectivity as a function of its behavioural responses to physical structure and chemical features of the host plants. Cocoon crop of A. mylitta is influenced by heterogeneity of tasar food plants and climatic conditions of the habitat. The role of host plants, temperature, humidity, rainfall, photoperiod and climatic variables on the growth and development of insects have clearly been demonstrated. This article entails an in-depth analysis on ecological and nutritional aspects of A. mylitta, which may provide selective information to researcher and forest managers, who are particularly associated with livelihood improvement of the poor people in forested area through location specific forest insect industry.

Citic Tower Construction Key Technology

  • Xu, Lishan
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.3
    • /
    • pp.185-192
    • /
    • 2019
  • Citic Tower is the first over-500 m-tall super highrise building in the world, located in the high seismic intensity area with paek ground acceleration over 0.2g in 475 years. This project is unique in its complexity, large volume, and challenging site conditions (zero site for construction). The traditional techniques can hardly meet safty, quality and schedule requirements of the construction. This article introduces the key construction technologies that are innovatively developed and applied in Citic Tower project construction, including intelligent super-high-rise building integrated construction platform system, independently developed by the CCTEB; Jump-Lift Elevator, which is the first of the kind with service height over 500 meters; combined temporary-and-permanent fire protection systems. The BIM technology is also applied in this project. Through technical innovation, and utilization of technologies, construction speed and safety had been greatly improved.

The Ecology of Lymnaea viridis, the Freshwater Snail, in the Field (민물에 서식하는 애기물달팽이의 야외생태)

  • 김상기;이정길
    • The Korean Journal of Malacology
    • /
    • v.8 no.1
    • /
    • pp.21-28
    • /
    • 1992
  • Field investigations were made in 1991 and 1992 in Kwangju and the western and central Chonnam area to determine the distribution of Lymnaea viridis, the intermediate host of Fasciola hepatica, and to study their life history during the different seasons. It had a wide distribution, existing all over the places, and the principal habitats of the snail were rice paddies. The life cycle was determined by making frequent visits to a series of habitats. The snsils began to produce egg masses in April, and egg production was the highest in May and June. Egg laying was continued but decreased in summer. There was sudden decrease in egg production in October when the temperature was below 2$0^{\circ}C$. The number of snails in July. Under the unfavourble conditions the snail either crawle up on the snail to aestivation. At low temperature below 8$^{\circ}C$ the snails hibernated inthe mud of the habitat. It was found in some habitats thao the snails were loving together with L. auricularia and Physa s pp. which indicates the neccessity of differentiation among them.

  • PDF

Simulating the Response of a 10-Storey Steel-Framed Building under Spreading Multi-Compartment Fires

  • Jiang, Jian;Zhang, Chao
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.389-396
    • /
    • 2018
  • This paper presents a numerical investigation on the structural response of a multi-story building subjected to spreading multi-compartment fires. A recently proposed simple fire model has been used to simulate two spreading multi-compartment fire scenarios in a 10-story steel-framed office building. By assuming simple temperature rising and distribution profiles in the fire exposed structural components (steel beams, steel column and concrete slabs), finite element simulations using a three-dimensional structural model has been carried out to study the failure behavior of the whole structure in two multi-compartment fire conditions and also in a standard fire condition. The structure survived the standard fire but failed in the multi-compartment fire. Whilst more accurate fire models and heat transfer models are needed to better predict the behaviors of structures in realistic fires, the current study based on very simple models has demonstrated the importance and necessity of considering spreadingmulti-compartment fires in fire resistance design of multi-story buildings.

Development of a Catch Basin Sump Insert to Reduce Mosquitoes

  • Kim, Dong Gun
    • Korean Journal of Environmental Biology
    • /
    • v.36 no.4
    • /
    • pp.554-557
    • /
    • 2018
  • A catch basin sump is one major habitat for mosquito larvae, especially in urban areas. This study developed a device for mosquito control, specifically for the catch basin sump. It consists of a housing, is a little smaller than the catch basin sump, numerous floating materials, which the key component for mosquito control, and mesh nets. The small balls or pyramid-shaped floating materials inhibit mosquito enclosures and spawning by significantly decreasing the surface area of the water, which is essential for the mosquito life cycle. These floating materials were designed to keep the water flowing. The mesh nets were installed to prevent the outflow of floating materials. The efficiency of the floating materials was tested with 3 conditions (1, 2, 3 layers of floating materials) and a control group. The emergence of mosquito adults decreased by 20% in one-layer, and 70-80% in second and third layers. Therefore, this device is expected to certainly contribute to mosquito population control in the catch basin sump.

Towards an Urban Troposphere

  • Kenoff, Jeffrey A;Gross, Peter
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.1
    • /
    • pp.15-24
    • /
    • 2022
  • Over the past 30 years, the tall building has seen unprecedented global support. With advanced innovation and many regions around the world discovering increasing growth rates, the tall, supertall, and megatall buildings continue to drastically alter the vertical urbanism of the cities they inhabit. For centuries, urban conditions in most major territories were predominately defined by the street wall and the spaces it shapes. Giambattista Nolli's 1748 Map of Rome most clearly illustrates this significance and possibly solidifies what generations would understand to be the predominant urban condition. As architects, it has been a city's lower vertical wall fabric that has often been the primary focus of efforts to craft an urban experience, and for good reason. Through recent examples of built and unbuilt KPF projects, this paper will explore an upper vertical wall fabric, an urbanism that not only exists at the ground but also within the troposphere.

Innovative Design and Practice in Horizontal Skyscraper-ChongQing Raffles

  • Li-Gang, Zhu
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.3
    • /
    • pp.197-205
    • /
    • 2022
  • One of important design challenges in Chongqing Raffles City Plaza project is Sky Bridge structural design and its connection scheme in high level. This article systematically describes the structural system and its design and analysis methodology, with discussing the impacts on structural performance due to different connection approaches. The seismic isolation scheme in high level is innovatively adopted to the final design. Under the conditions of various load cases, the different models and assumptions are implemented. A full assessment on Sky Bridge's structural performance, seismic isolation, and its connection is conducted in terms of seismic performance based design. By co-operating with architecture, MEP and other disciplines, the structural economy index is fulfilled.

A New Paradigm for Wind Design

  • M. Burton;M. Tatarsky;I. Ashcroft
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.4
    • /
    • pp.363-368
    • /
    • 2022
  • For taller buildings with unconventional architecture, refined structural systems or in geographical areas with high wind conditions, performance-based design can be seen as an enhanced design process and is either a supplement to, or alternative to a prescriptive code-based design. The ultimate goal of Performance-Based Wind Design (PBWD) is to result in a building that better addresses key goals of performance over the buildings full life cycle. Major innovations around the use of a PBWD approach include nonlinear dynamic analysis for wind design, limited inelasticity in the main wind force resisting system elements, and system-based performance criteria. This paper discusses potential considerations and benefits made when using a performance-based approach, in addition to the general practicality of use, for the structural design on a few key tall buildings.

Rapid ecosystem services assessment of Mundok Ramsar wetland in Democratic People's Republic of Korea and opportunities to improve well-being

  • Hyun-Ah Choi;Bernhard Seliger;Donguk Han
    • Journal of Ecology and Environment
    • /
    • v.47 no.2
    • /
    • pp.27-34
    • /
    • 2023
  • Background: The understanding of ecosystem services can be quantified and qualitative to assess the impacts of changes in the ecosystem to support human well-being. In the Democratic People's Republic of Korea, sustainable use of ecosystem services has attracted the interest of a range of decision-makers. However, although there is a concern for biodiversity, natural ecosystem, and their services, linking ecosystems with conservation planning remains challenging. Results: This study assessed the first qualitative ecosystem services provided by the Mundok wetland with decision makers of the West/Yellow Sea region. Furthermore, this study applied the Rapid Assessment Wetland Ecosystem method to support natural resources management, improving living conditions. We identified that cultural and supporting services index are highly provided, but preparing a plan to increase the provisioning and regulating services in Mundok wetland is necessary. Conclusions: The assessment results can provide helpful information for ecosystem services assessment, habitat conservation, conservation planning, and decision-making at local level.

Experimental Study of Moisture-Wicking Fabric as Cooling Pad for Novel Rotary Direct Evaporative Cooler

  • Sang-Hwan Park;Jae-Weon Jeong
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.4
    • /
    • pp.335-341
    • /
    • 2023
  • This study proposes a novel rotary direct evaporative cooler and investigates the potential of a moisture-wicking fabric as a cooling pad for the proposed evaporative cooler. The rotary direct evaporative cooler rotates the cooling pad to reduce the water and energy consumption of the pump compared to those of existing direct evaporative coolers. A moisture-wicking fabric is considered as the material of the cooling pad, because of its high moisture-wicking property, enhancing water evaporation. Experiments are performed under various inlet air conditions while measuring the air temperature, relative humidity, air velocity, and differential pressure. The evaporative cooling efficiency and impacts of the inlet air temperature and air velocity on the cooling performance are also evaluated. The results demonstrate the potential of the moisture-wicking fabric as cooling pad of direct evaporative cooler.