• 제목/요약/키워드: HTS cables design

검색결과 33건 처리시간 0.017초

Review of the design, production and tests of compact AC HTS power cables

  • Fetisov, S.S.;Zubko, V.V.;Nosov, A.A.;Zanegin, S.Yu.;Vysotsky, V.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권4호
    • /
    • pp.31-39
    • /
    • 2020
  • Power cables made of high temperature superconductors (HTS) are considered as most advanced applications of superconductivity for electro-energetics. Several cables made of the First Generation (1G) HTS wires have been produced and installed to electrical grids worldwide. Power cables made of the Second Generation HTS wires (2G or Coated Conductors) are in active development. Most basic principles of HTS power cables development have been published in many works since 90-ties. In this Review we would like to present our new developments mostly directed to 2G HTS compact power cables. We are presenting the methods to optimize a design of 2G AC compact power cable providing uniform current distribution among cable layers and the production technology approaches to implement such a design. AC losses measurements in such cables and other test methods are described. Some problems of the development 2G HTS power cables with small diameters are discussed. We presented as examples designs, developments and test results of two major coaxial cables designs: single-phase (cable core and a shield) and three-phase (triaxial: with three coaxial phases).

Design and tests of prototype HTS power transmission cables

  • 하홍수;조영식;오상수;성기철;권영길;류강식;조전욱
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.280-284
    • /
    • 2000
  • The prototype high-T$_c$ superconducting (HTS) power transmission cables have been designed and fabricated multi layers of spirally wound HTS tapes. The cables were made Bi-2223 based Ag-sheathed HTS tapes, and tested in LN$_2$. Critical currents of 700A dc and better were achieved. The magnetic flux density and field direction were analyzed in the cable configuration. In this paper the results of analysis and tests of HTS power transmission cables were described.

  • PDF

고온초전도 케이블의 대도시 계통적용을 위한 모델링 및 송전용량과 전압계급의 검토 (A Study on System Modeling, Capacity and Voltage rating to supply HTS Power Transmission Cable to Metropolitan Area)

  • 최상봉;정성환;김대경;김학만;문영환;성기철
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.61-65
    • /
    • 2002
  • It becomes difficult and high in cost to construct new ducts and/or tunnels for power cables in metropolitan areas. This paper presents possible applications of an HTS superconducting power cables for transmitting electric power in metropolitan areas. Reflected were its important distinction such as compactness for installation in underground ducts and considerably high efficiency compared with present underground cables. In this paper, system modeling, transmission capacity and voltage class of compact HTS cables which should be applied to existing ducts were reviewed. Based on this, the following items on urban transmission system are examined. (1) A method of constructing a model system to introduce high temperature superconducting cables to metropolitan areas is presented. (2)The maximum outer diameter of HTS cables to be accommodated in exiting ducts is calculated based on the design standards for current cable ducts. (3)The voltage level that can be accommodated by existing ducts is examined.

Cold electronics based 128 temperature sensor interface with 14 leads for testing of high Tc superconducting cable

  • Gour, Abhay Singh;Thadela, S.;Rao, V.V.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권1호
    • /
    • pp.11-14
    • /
    • 2018
  • High Temperature Superconducting (HTS) power cables are capable of transmitting bulk power without any loss compared to conventional copper cables. The major challenge in the design of such HTS cables is the high stresses (electro-thermal/electro-mechanical) developed at high voltages, high currents and cryogenic temperatures. The safe and reliable operation of HTS cables involves lots of instrumentation for monitoring, measurement, control and safe operation. In principle, a four probe method for resistance (RTD PT-100) is used for temperature measurements at various locations of HTS cable. The number of connecting leads required for this is four times that of the number of sensors. The present paper discusses a novel way of connecting 128 RTD sensors with the help of only 14 leads using a cold electronics based multiplexer board. LabVIEW 11.0 software was used for interfacing and displaying the readings of all the sensors on computer screen.

고온초전도 전력케이블 적용가능성 검토 (A Feasibility Study of HTS Power Cable in the Future)

  • 성기철;조전욱;권영길;류강식;강민규;유인근
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.125-127
    • /
    • 2000
  • In this study, we performed long lange power transmission expansion planning for conceptual design of HTS power cable in Seoul area. Since the HTS power cable has the high power transmission density and low loss characteristics in comparison with conventional power cables, the HTS power cable is introduced between the downtown and the suburbs in the future system in order to verify the feasibility of the HTS power transmission cables technically and to encourage the research activity in the area.

  • PDF

Development and performance test of a liquid nitrogen circulation pump for HTS power cable

  • Seok, Jihoon;Kim, Dongmin;Lee, Changhyeong;Kim, Manryeol;Choi, Jeongdong;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권3호
    • /
    • pp.28-33
    • /
    • 2018
  • With the continuous performance improvement and commercialization of HTS wires, there have been many efforts to commercialize HTS power cables recently. Unlike conventional power cables, a cryogenic cooling system is required for a HTS power cable and a cryogenic pump is one of the essential components to circulate subcooled liquid nitrogen and cool the HTS power cable. Especially, the development of a reliable and high-efficiency cryogenic pump is an important issue for the commercialization of HTS power cables of several kilometers or more. In this study, we designed and fabricated a cryogenic pump for subcooled liquid nitrogen with a mass flow rate of 1.2 kg/s, a differential pressure of 5 bar, and evaluated the hydraulic performance of the pump. Impeller design was conducted to meet the target design performance with 1 D analysis model and CFD analysis. The pump performance parameters such as pressure heads, mass flow rates, and efficiencies in accordance with rotating speeds were assessed using a laboratory's performance evaluation system.

Pressure drop characteristics of concentric spiral corrugation cryostats for a HTS power cable considering core surface roughness

  • Youngjun Choi;Seokho Kim
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권2호
    • /
    • pp.19-24
    • /
    • 2023
  • Recently, interest in renewable energy such as solar and wind power has increased as an alternative to fossil fuels. Renewable energy sources such as large wind farms require long-distance power transmission because they are located inland or offshore, far from the city where power is required. High-Temperature Superconducting (HTS) power cables have more than 5 times the transmission capacity and less than one-tenth the transmission loss compared to the existing cables of the same size, enabling large-capacity transmission at low voltage. For commercialization of HTS power cables, unmanned operation and long-distance cooling technology of several kilometers is essential, and pressure drop characteristic is important. The cryostat's spiral corrugation tube is easier to bend, but unlike the round tube, the pressure drop cannot be calculated using the Moody chart. In addition, it is more difficult to predict the pressure drop characteristics due to the irregular surface roughness of the binder wound around the cable core. In this paper, a CFD model of a spiral corrugation tube with a core was designed by referring to the water experiments from previous studies. In the four cases geometry, when the surface roughness of the core was 10mm, most errors were 15% and the maximum errors were 23%. These results will be used as a reference for the design of long-distance HTS power cables.

Design of The Electrical Insulation for The High Temperature Superconducting Cable Based on Model Investigation

  • A.M Andreev;Kim, Ji-Hwan;Kim, Do-Woon;Jang, Hyun-Man;Kim, Dong-Wook;Kim, Sang-Hyun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권3호
    • /
    • pp.52-56
    • /
    • 2003
  • This paper describes the results of a basic study (on a model samples) for the development of 22.9 kV high temperature superconducting (HTS) cable. The authors have established that the factors that decide the performance of HTS cables are butt gaps in tape insulation and carbon particles from semiconductive layer. The insulation performance of HTS cables is determined by size and quality of these elements. In the model tests of HTS cables, the minimum PD inception stress of the tape insulation impregnated with liquid nitrogen was found and insulation thickness was calculated from this result.

Design of HTS power cable with fault current limiting function

  • Kim, Dongmin;Kim, Sungkyu;Cho, Jeonwook;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권1호
    • /
    • pp.7-11
    • /
    • 2020
  • As demand for electricity in urban areas increases, it is necessary to improve electric power stability by interconnecting neighboring substations and high temperature superconductor (HTS) power cables are considered as a promising option due to its large power capacity. However, the interconnection of substations reduces grid impedance and expected fault current is over 45 kA, which exceeds the capacity of a circuit breaker in Korean grid. To reduce the fault current below 45 kA, a HTS power cable having a fault current limiting (FCL) function is considered by as a feasible solution for the interconnection of substations. In this study, a FCL HTS power cable of 600 MVA/154 kV, transmission level class, is considered to reduce the fault current from 63 kA to less than 45 kA by generating an impedance over 1 Ωwhen the fault current is induced. For the thermal design of FCL HTS power cable, a parametric study is conducted to meet a required temperature limit and impedance by modifying the cable core from usual HTS power cables which are designed to bypass the fault current through cable former. The analysis results give a minimum cable length and an area of stainless steel former to suppress the temperature of cable below a design limit.

고온초전도 전력케이블 적용효과 검토 (A Study on the Application Effects of HTS Power Cable)

  • 성기철;조전욱;김해종;권영길;최상봉;류강식;김봉태;유인근
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권2호
    • /
    • pp.32-36
    • /
    • 2000
  • In this study, we performed the long-term expansion planning for the conceptual design of HTS power cable in Seoul area. In Korea, underground power cable has been required gradually with increasing demand of electric power transmission density and low loss characteristics in the comparison with a conventional power cables, so we assumed that the HTS power cable is applied between the downtown area and the outskirts of the city for the large power transmission capacity. This paper is to show the effects of HTS power cables in Seoul based on the power system analysis.

  • PDF