• Title/Summary/Keyword: HRV(Heart Rate Variability)

Search Result 564, Processing Time 0.024 seconds

Objective Evidence for the Effectiveness of Single-session Treatment with a Spinal Thermal Massage Device: A Pilot Study (척추온열마사지기기의 1회 치료의 효과에 대한 객관적 증거: 선행 연구)

  • Na, Yeong-Il;Kim, Si-Yun;Baek, Seung-Min;Lee, Jong-Hoo
    • Journal of Industrial Convergence
    • /
    • v.20 no.10
    • /
    • pp.209-218
    • /
    • 2022
  • Individuals often report significant relief from pain and stress even after a single session of massage therapy; however, no previous studies have provided objective evidence supporting the effectiveness of a solitary massage therapy session. In the present study, we aimed to investigate the effectiveness of one-time treatment with a spinal thermal massage device reported to exert the same therapeutic effects as massage therapy in terms of pain reduction and stress relief. A man with chronic low back pain (LBP) underwent two rounds of experiments involving spinal massage treatment and bed rest, respectively. Pain was assessed using a visual analog scale, and heart rate variability (HRV) was measured in real-time to examine autonomic nervous system (ANS) activity. Blood samples were obtained at five points during each round of the experiment to examine changes in cortisol, epinephrine, and norepinephrine. Spinal massage significantly reduced pain and enhanced parasympathetic activity when compared with the bed rest condition. In addition, both epinephrine and norepinephrine levels were lower following spinal massage than following bed rest. These results are consistent with the reported effects of conventional massage therapy and support the effectiveness of one-time treatment using a spinal thermal massage device.

A Study on Wearable Emotion Monitoring System Under Natural Conditions Applying Noncontact Type Inductive Sensor (자연 상태에서의 인간감성 평가를 위한 비접촉식 인덕티브 센싱 기반의 착용형 센서 연구)

  • Hyun-Seung Cho;Jin-Hee Yang;Sang-Yeob Lee;Jeong-Whan Lee;Joo-Hyeon Lee;Hoon Kim
    • Science of Emotion and Sensibility
    • /
    • v.26 no.3
    • /
    • pp.149-160
    • /
    • 2023
  • This study develops a time-varying system-based noncontact fabric sensor that can measure cerebral blood-flow signals to explore the possibility of brain blood-signal detection and emotional evaluation. The textile sensor was implemented as a coil-type sensor by combining 30 silver threads of 40 deniers and then embroidering it with the computer machine. For the cerebral blood-flow measurement experiment, subjects were asked to attach a coil-type sensor to the carotid artery area, wear an electrocardiogram (ECG) electrode and a respiration (RSP) measurement belt. In addition, Doppler ultrasonography was performed using an ultrasonic diagnostic device to measure the speed of blood flow. The subject was asked to wear Meta Quest 2, measure the blood-flow change signal when viewing the manipulated image visual stimulus, and fill out an emotional-evaluation questionnaire. The measurement results show that the textile-sensor-measured signal also changes with a change in the blood-flow rate signal measured using the Doppler ultrasonography. These findings verify that the cerebral blood-flow signal can be measured using a coil-type textile sensor. In addition, the HRV extracted from ECG and PLL signals (textile sensor signals) are calculated and compared for emotional evaluation. The comparison results show that for the change in the ratio because of the activation of the sympathetic and parasympathetic nervous systems due to visual stimulation, the values calculated using the textile sensor and ECG signals tend to be similar. In conclusion, a the proposed time-varying system-based coil-type textile sensor can be used to study changes in the cerebral blood flow and monitor emotions.

The Changes of Short-Term Memory and Autonomic Neurocardiac Function after 4-10Hz Sound and Light Stimulation - A Pilot Study - (4-10 Hz 빛과 소리자극 후 단기기억력 및 자율신경심장기능의 변화 - 예비연구 -)

  • Lee, Seung-Hwan;Kim, Jin-Hwan;Park, Joong-Kyu;Lee, Kyung-Uk;Yang, Dae-Hyun;Hong, Keun-Young;Chae, Jeong-Ho
    • Sleep Medicine and Psychophysiology
    • /
    • v.11 no.1
    • /
    • pp.29-36
    • /
    • 2004
  • Objectives: Sound and light (SL) stimulation has been used as a method to induce some useful mental states in the fields of psychology and psychiatry. It is believed that sound and light entrainment device (SLED) has some specific effects through synchronization of EEG in patients who use it. Theta frequency is believed to stimulate deep relaxation and short term memory processing. This study was conducted to evaluate if 4-10 Hz SL stimulation can induce relaxation and improve short term memory function. Methods: Ten medical students with no medical or psychiatric problems participated in this study. Subjects were randomly divided into two groups. One group was applied with real SLED was applied to one group (R group) and pseudo SLED to the other group (P group). The two groups were exposed to SL stimulation with SLED 15 minutes a day for 5 days, and after two days rest the two groups were switched over. The Korean Wechsler Adult Intelligence Scale (K-WAIS), Academic Motivation Tests (AMT), Test Anxiety Scale (TAS), Korean Auditory Verbal Learning Test (K-AVLT), and digit span were used to evaluate short term memory. Spielberger's State-Trait anxiety inventory and heart rate variability (HRV) test were used to evaluate degree of relaxation. Results: Compared with S group, R group showed a significant improvement in K-AVLT and digit span after a single application of SL stimulation. But 5-day long application did not reveal any differences between the two groups. A significant change in HRV was observed in 5-day long application of SL stimulation after being switched over to other SLED. Conclusion: This pilot study suggests that 4-10 Hz SL stimulation has some positive influences on short term memory and relaxation.

  • PDF

Kinemetic analysis of a thumping security motion with an expandable barton (경호원의 삼단봉 머리치기 동작의 운동학적 분석)

  • Kim, Yong-Hak;Kim, Sin-Hye;Jung, Sung-Bae
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.93-109
    • /
    • 2013
  • This research is mainly based on the experimental result due to seek different outcomes whena certain security motion with a paticular gear is applied in a plausible confrontational situation. For the purpose of this research an Expandable Baton, which is one of the most commonsecurity equipments, was chosen to be applied in a situation of hitting a person's head. Alsothe results will be studied in the view of Kinematic theory. To demonstrate, 10 students who were majeored in Escort Crane studies at 'H' university werechosen as testees. The participants were grouped into two-one is practiced with the 'expanadable baton use program' and the other is pre-practiced. In this report two groups abovewill be reffered as 'group A' and 'group B' for conveniency. There were a number of differences and changes between two groups. Group B took more timethan the other group did. Group A spent about 0.428sec in section 'e2' and 0.230sec in section'e3' while Group B took 0.435sec, 0.232sec in each sections.To add on, more distinctive results were out when it was more focused on physical movements. Two gropus presented considerable changes- in an 'left-right' moving displacement-Group A;$2.16{\pm}0.9cm$ (left side), $3.78{\pm}1.42cm$ (right side), total $5.94{\pm}2.03cm$. Group B; $2.97{\pm}1.01cm$ (left side),$4.56{\pm}1.57cm$ (right side), total $7.53{\pm}2.13cm$.Continuously, different outcomeswere shown between two groups in a 'back and forth' moving displacement-Group A;$32.48{\pm}3.86cm$, $35.21{\pm}4.64cm$, total $69.36{\pm}5.72$. Group B; $34.50{\pm}6.12cm$, $37.04{\pm}3.70cm$, total $71.46{\pm}7.17cm$. Furthermore, changes in an 'up and down' moving displacement were - GroupA; $5.62{\pm}2.41cm$, $4.54{\pm}1.87cm$, total $10.11{\pm}1.57cm$. Group B; $6.33{\pm}1.78cm$, $4.86{\pm}1.85cm$,total $10.68{\pm}1.81cm$. To continue, there were few modifications of degree on participants' joints, espcially on 'Wristjoint', 'Elbow joint' and 'Shoulder joint', depend on different sections -Wrist joint;Group A; e1 $114.62{\pm}7.13$, e2 $68.27{\pm}6.37$, e3 $131.64{\pm}6.27$. Group B; e1 $112.62{\pm}6.13$, e2 $66.28{\pm}7.38$, e3$137.42{\pm}4.28$ and Elbow joint ; Group A e1 $132.31{\pm}6.55$, e2 $117.92{\pm}8.42$, e3 $144.41{\pm}6.32$. Group B; e1 $133.58{\pm}8.56$, e2 $114.45{\pm}8.21$, e3 $139.89{\pm}4.38$. Lastly, degree changes ofshoulder joint were; Group A; e1 $13.55{\pm}3.85$, e2 $131.42{\pm}11.24$, e3 $78.32{\pm}6.28$. Group B; e1$9.45{\pm}1.23$, e2 $136.74{\pm}13.21$, e3 $79.75{\pm}4.24$.

  • PDF