• Title/Summary/Keyword: HPLC quantification

Search Result 403, Processing Time 0.019 seconds

Determination of florfenicol residues in swine tissues using high-performance liquid chromatography with ultraviolet photometric detector

  • Chae, Won-Seok;Yoo, Chang-Yeul;Tutkun, Lutfiye;Kim, Suk;Lee, Hu-Jang
    • Journal of Preventive Veterinary Medicine
    • /
    • v.42 no.4
    • /
    • pp.171-176
    • /
    • 2018
  • A study of the tissue depletion of florfenicol (FFC) administered orally to pigs at a dose of 0.05 kg/ton feed for 7 days was performed. Sixteen healthy cross swine were administered with FFC. Four treated animals were arbitrarily selected to be sacrificed 1, 3 and 5 days after the end of treatment. FFC residue concentrations in muscle, liver, kidney, and fat were determined using high-performance liquid chromatography (HPLC) with ultraviolet photometric detector at 230 nm. The correlation coefficient ($R^2$) of the calibration curve for florfenicol amine (FFCa) was > 0.997 and the limits of detection and quantification were 0.012 and $0.040{\mu}g/mL$, respectively. Recovery rates in swine edible tissues ranged from 79.1 to 93.5%. In the FFC-treated group, FFC residues at 3 days post-treatment were below the maximum residue limits (MRLs) in muscle, kidney and fat, and those at 5 days post-administration were below the MRLs in all edible tissues. These results suggest that the withdrawal period of FFC after the drug treatment might be 5 days, which is a sufficient amount of time for reduction of the FFC residues below the MRLs in all edible tissues.

Development and Validation of Quantitative Analysis Method for Phenanthrenes in Peels of the Dioscorea Genus

  • Kim, Hunseong;Cao, Thao Quyen;Yeo, Chae-eun;Shin, Seung Ho;Kim, Hiyoung;Hong, Dong-Hyuck;Hahn, Dongyup
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.8
    • /
    • pp.976-981
    • /
    • 2022
  • Phenanthrenes are bioactive phenolic compounds found in genus Dioscorea, in which they are distributed more in peel than in flesh. Recent studies on phenanthrenes from Dioscorea sp. peels have revealed the potential for valuable biomaterials. Herein, an analytical method using high-performance liquid chromatography (HPLC) for quantitation of bioactive phenanthrenes was developed and validated. The calibration curves were obtained using the phenanthrenes (1-3) previously isolated from Dioscorea batatas concentrations in the range of 0.625-20.00 ㎍/ml with a satisfactory coefficient of determination (R2) of 0.999. The limit of detection (LOD) and the limit of quantification (LOQ) values of the isolated phenanthrenes ranged from 0.78-0.89 and 2.38-2.71 ㎍/ml, respectively. The intraday and interday precision ranged from 0.25-7.58%. The recoveries of the isolated phenanthrenes were from 95 to 100% at concentrations of 1.25, 2.5, and 5.0 ㎍/ml. Additionally, phenanthrenes (1-3) were found in all investigated peel extracts. Hence, the developed method was encouraging for the quantitative analysis of phenanthrenes in genus Dioscorea.

Quantitative analysis of hyperoside and isoquercitrin in methanolic extract of Stewartia koreana leaves using HPLC-DAD

  • Ju-Yeong Kang;Yu Hwa Kim;Youngdae Yoon;Bong-Gyu Kim
    • Journal of Applied Biological Chemistry
    • /
    • v.66
    • /
    • pp.436-446
    • /
    • 2023
  • Since Stewartia koreana leaves are registered with the Food and Drug Administration as edible herbal materials, they are used in the development of functional foods, cosmetics, and medicines. In this study, we established an analysis method that can simultaneously analyze two indicators, hyperoside (quercetin 3-O-galactoside) and isoquercitrin (quercetin 3-O-glucoside) contained in the leaves of S. koreana using HPLC-DAD. In accordance with the Ministry of Food and Drug Safety's health functional food guidelines, the analysis method was verified for specificity, accuracy, precision, limit of quantification, and linearity. The analysis method established in this study showed more than 0.9989 of the correlation coefficient values (r2) for the calibration. The total recovery rates of isoquercitrin and hyperoside were 100.55 and 98.87% with 0.14-0.78 and 0.47-0.67% of the relative standard deviation, respectively. Therefore, it was suggested that the new analytical method would be applied to standardize raw materials and high value-added products originated from the leaves of the S. koreana in the future.

Development and validation of an analytical method for the determination of lepimectin residues by HPLC-PDA (HPLC-PDA를 이용한 lepimectin 잔류량 분석법 개발 및 확인)

  • Do, Jung-Ah;Kwon, Ji-Eun;Kim, Mi-Ra;Lee, Eun-Mi;Kuk, Ju-Hee;Kwon, Kisung;Oh, Jae-Ho
    • Analytical Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.142-153
    • /
    • 2013
  • A new, rapid, and simple analytical method was developed and validated using high performance liquid chromatograph-photodiode array detector (HPLC-PAD) for the determination of lepimectin residues in agricultural commodities. The lepimectin residues in samples were extracted with methanol, partitioned with dichloromethane, and then purified with glass column filled with subsequently to aminopropyl ($NH_2$) solid phase extraction (SPE) cartridge. The purified samples were detected using HPLC-PAD. Correlation coefficient ($R^2$) of both lepimectin $A_3$ and $A_4$ solutions were 0.9999. The method was validated using cucumber spiked with lepimectin at 0.02 and 0.2 mg/kg and pepper, mandarin, hulled rice, potato, soybean at 0.02 and 0.5 mg/kg. Average recoveries were 76.0~114.8% with relative standard deviation less than 10%, and limit of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.01 mg/kg, respectively. The result of recoveries and overall coefficient of variation of a laboratory results in Gwangju regional KFDA and Daejeon regional KFDA was followed with Codex guideline (CAC/GL 40). Therefore, developed method in this study is accurate, rapid, and appropriate for lepimectin determination and will be used to keep safety of lepimectin residues in agricultural products.

A Survey of Zearalenone in Beans Using High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FLD) and Ultra Performance Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) (HPLC-FLD 및 LC-MS/MS에 의한 두류 중 제랄레논 오염실태 조사)

  • Jang, Mi-Ran;Lee, Chang-Hui;Lee, Hyo-Jeong;Kim, Ji-Yeon;Son, Sang-Hyeok;Sin, Chun-Sik;Kim, So-Hui;Kim, Dae-Byeong
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.3
    • /
    • pp.354-359
    • /
    • 2008
  • A survey for zearalenone contamination was conducted on 27 soy bean samples, 27 red bean samples, 16 black bean samples, 19 seoritae samples, 14 seomoktae samples, for a total of 127 commercial Korean samples. Zearalenone was quantified by the immunoaffinity column clean-up method with high performance liquid chromatography-fluorescence detection (HPLC-FLD), and was confirmed by liquid chromatography tandem mass spectrometry(LC-MS/MS). The limits of detection and quantification were $2.0{\mu}g/kg$ and $6.0{\mu}g/kg$, respectively. The recovery in the beans ranged from 82.2 to 98.4%. According to HPLC-FLD, zearalenone was detected in 13 samples (10.2% incidence), including 1 soybean and 12 red bean samples. The zearalenone contamination levels were in the range of 8.01${\sim}38.98{\mu}g/kg$. Finally, LC-MS/MS analysis was conducted in the contaminated samples to verify the results of HPLC-FLD. The LC-MS/MS results confirmed the presence of zearalenone in all 13 samples. The contamination level was lower than that of EU, which is below $100{\mu}g/kg$ for raw grains.

Quantification of urea in serum by isotope dilution HPLC/MS (동위원소 희석 HPLC/MS에 의한 혈청 내 urea의 정량)

  • Lee, Hwashim;Park, Sangryoul
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.271-277
    • /
    • 2005
  • Urea in blood has been measured as an effective marker for diagnosis of renal function. Urea which is e end-product of nitrogen containing metabolites such as proteins is filtered through glomeruli of kidneys and then excreted as urine. If the renal function is deteriorated, the urea concentration in blood will be increased, from which the healthiness of renal function is judged. In order to improve the confidence of diagnosis results, the results must keep traceability chain to certified reference materials, which was certified by primary reference method. In this study, we proposed isotope dilution-liquid chromatography/mass spectrometry (ID-LC/MS) as a candidate primary method, in which $15^N_2$-urea is used as an internal reference material. The developed method is highly accurate in principle and is convenient as it does not require cumbersome derivatization. 0.1 mmol/L ammonium chloride was selected as a mobile phase for HPLC because it provided low interference in MS analysis of relatively low molecular weighted urea. HPLC and MS were connected with an electrospray ionization (ESI) interface of positive mode, which provided high sensitivity and reproducibility. The developed method was validated with internationally recognized reference materials, and we have obtained satisfactory results in an international ring trial. The expanded uncertainty calculated according to ISO guide was 1.8% at 95% confidence interval. The developed method is being used as a primary reference measurement method such as for certification of serum certified reference materials (CRMs).

Development of Analytical Methods of Hyperoside from Rosa canina L. (Rosa canina L. 중 hyperoside의 시험법 개발 연구)

  • Oh, Jae Myoung;Lee, Hwa Jung;Bahn, Kyeong Nyeo;Seo, Il Won;Lee, Young Joo;Lee, Jin Hee;Park, Ji Min;Kang, Tae Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.173-177
    • /
    • 2015
  • Rosa canina L. is health functional food materials that can help to temporarily relieve symptoms of arthritis. This study has been conducted to develop and validate analytical methods for hyperoside of Rosa canina L.. Methods based on HPLC with ultraviolet detection (UVD) were established through instrumental analytical conditions, and the examination of data, such as domestic and foreign reliable methods and journals. HPLC UVD analysis using Capcell Pak $C_{18}$ MG II column at 353 nm was determined on test through the column, mobile phase. The validation has been performed on the method to determine linearity, accuracy, limits of quantification (LOQ) and repeatability for hyperoside. The method showed high linearity in the calibration curve at a coefficient of correlation ($R^2$) of 0.999, and the LOQ was $0.393{\mu}g/mL$. Relative standard deviation (RSD) values of data from repeatability precision was between 0.6 and 2.6%. Recovery rate test at hyperoside scored between 98 and 99%. These results indicate that the established HPLC method is very useful for the determination of hyperoside in Rosa canina L. to develop a health functional material.

Establishment of Analytical Method for Propylene Glycol Alginate in Food Products by Size-exclusion Chromatography (Size-exclusion chromatography법에 의한 식품 중 알긴산프로필렌글리콜 분석법 확립)

  • Jeong, Eun-Jeong;Choi, Yoo-Jeong;Lee, Gunyoung;Yun, Sang Soon;Lim, Ho Soo;Kim, Yong-Suk
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.404-410
    • /
    • 2017
  • An analytical method for determination of propylene glycol alginate (PGA) in food products was developed by HPLC-size-exclusion chromatography. The GF-7M HQ column and LT-ELSD detector were determined by considering the instrumental analysis conditions for PGA analysis. The pretreatment method for the analysis of PGA was suitable for 3 hr extraction at $20^{\circ}C$ and 150 rpm according to the extraction temperature. Linearity ($R^2$) for the analysis of PGA was 0.9873 at calibration curve range of 300, 500, 700, 1,000, and 1,500 mg/kg (5 points). The limit of detection and limit of quantification of PGA on HPLC system was 171.43 and 519.50 mg/kg, respectively. The accuracy and coefficient of variation obtained by size-exclusion chromatography were 86.1~110.4% and 4.1~13.5%, respectively. By applying the HPLC-size-exclusion chromatography system, it was possible to analyze the contents of PGA in 134 different types of food products.

A Comparative Study of the Assay Methods Used to Quantify Fermentable Sugar in Makgeolli Sul-dut (막걸리 술덧의 발효성 당 분석방법 비교 연구)

  • Kim, Byong-Soo;Kim, Gye-Won;Shim, Jae-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.1
    • /
    • pp.48-53
    • /
    • 2016
  • The objective of this study was to evaluate the accuracy and efficiency of different methods used for the fermentable sugar assay in the production of Makgeolli sul-dut. In the initial stage of fermentation, Ipguk treatment produced a higher alcohol content compared to the Nuruk treatment. However, the alcohol content was not significantly different between the two starters at the final stage of fermentation. Acidity in the Ipguk treatment was higher than that of Nuruk throughout the fermentation period. After analyzing the fermentable sugars using dinitrosalicylic acid (DNS), Fehling's method, refractometer, glucose kit, and high performance liquid chromatography (HPLC), it was confirmed that the HPLC method was the most accurate for fermentable sugar quantification. In both types of starters, DNS and Fehling's methods showed results comparable to HPLC in terms of fermentable sugar content, while the glucose kit and refractometer analyses showed relatively large discrepancies, indicating that the Fehling's method could also be effective for the analysis of fermentable sugars in the manufacture of Makgeolli.

Development and Validation of Analytical Method for Decursin in Aerial Parts of Angelica gigas Nakai Extract (참당귀 지상부 추출물의 지표성분 decursin의 분석법 개발 및 검증)

  • Kim, Hee-Yeon;Lee, Ki-Yeon;Kim, Tae-Hee;Park, A-Reum;Noh, Hee-Sun;Kim, Si-Chang;Ahn, Mun-Seob
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.52-57
    • /
    • 2019
  • Method development and validation of decursin for the standardization of Angelica gigas Nakai as a functional ingredient and health food were accomplished. The quantitative determination method of decursin as a marker compound of aerial parts of Angelica gigas Nakai extract (AAGE) was optimized by HPLC analysis using a C18 column ($3{\times}150mm$, $3{\mu}m$) with 0.1% TFA in water and acetonitrile as the mobile phase at a flow rate of 0.5 mL/min and detection wavelength of 330 nm. The HPLC/PDA method was applied successfully to quantification of the marker compound in AAGE after validation of the method with linearity, accuracy, and precision. The method showed high linearity in the calibration curve at a coefficient of correlation ($R^2$) of 0.9994 and the limit of detection and limit of quantitation were $0.011{\mu}g/mL$ and $0.033{\mu}g/mL$, respectively. Relative standard deviation (RSD) values of data from intra- and inter-day precision were less than 1.10% and 1.13%, respectively. Recovery of decursin at 0.5, 1, 5 and $10{\mu}g/mL$ were 92.38 ~ 104.11%. These results suggest that the developed HPLC method is very useful for the determination of marker compound in AAGE to develop a health functional material.