Development of a Signal Conditioner to Improve the Measurement Reliability of a Microseismic Monitoring System (미소진동 모니터링 시스템의 측정 신뢰도 향상을 위한 시그널 컨디셔너 개발)

  • Cheon, Dae-Sung;Han, Cheol-Min;Lee, Jang Baek
    • Tunnel and Underground Space
    • /
    • v.30 no.1
    • /
    • pp.1-14
    • /
    • 2020
  • Microseismic monitoring is utilized for the performance verification and safety management of the structure by detecting fine levels of damage. In order to construct a highly reliable microseismic monitoring system, the role of signal conditioner is critical. The signal conditioner helps with accurate data collection and precision control of the device, and performs additional functions such as signal conversion, linearization, and amplification. In this technical report, noise reduction signal conditioner suitable for mining sites was developed and reviewed for the purpose of implementing more precise monitoring by supplementing the previously developed microseismic monitoring system.

Measurement of Properties of Domestic Bentonite for a Buffer of an HLW Repository (고준위폐기물 처분장의 완충재용 국내산 벤토나이트의 특성 측정)

  • Yoo, MalGoBalGaeBitNaLa;Choi, Heui-ju;Lee, Min-soo;Lee, Seung-yeop
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.2
    • /
    • pp.135-147
    • /
    • 2016
  • The buffer in geological disposal system is one of the major elements to restrain the release of radionuclide and to protect the container from the inflow of groundwater. The buffer material requires long-term stability, low hydraulic conductivity, low organic content, high retardation of radionuclide, high swelling pressure, and high thermal conductivity. These requirements could be determined by the quantitative analysis results. In case of South Korea, the bentonites produced in Gyeongju area have been regarded as candidate buffer/backfill materials at KAERI (Korea Atomic Energy Research Institute) since 1997. According to the study on several physical and chemical characteristics of domestic bentonite in the same district, this is the Ca-type bentonite with about 65% of montmorillonite content. Through this study, we present the criteria for the performance evaluation items and methods when collecting new buffer/backfill materials.

Coupled T-H-M Processes Calculations in KENTEX Facility Used for Validation Test of a HLW Disposal System (고준위 방사성 폐기물 처분 시스템 실증 실험용 KENTEX 장치에서의 열-수리-역학 연동현상 해석)

  • Park Jeong-Hwa;Lee Jae-Owan;Kwon Sang-Ki;Cho Won-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.117-131
    • /
    • 2006
  • A coupled T-H-M(Thermo-Hydro-Mechanical) analysis was carried out for KENTEX (KAERI Engineering-scale T-H-M Experiment for Engineered Barrier System), which is a facility for validating the coupled T-H-M behavior in the engineered barrier system of the Korean reference HLW(high-level waste) disposal system. The changes of temperature, water saturation, and stress were estimated based on the coupled T-H-M analysis, and the influence of the types of mechanical constitutive material laws was investigated by using elastic model, poroelastic model, and poroelastic-plastic model. The analysis was done using ABAQUS, which is a commercial finite element code for general purposes. From the analysis, it was observed that the temperature in the bentonite increased sharply for a couple of days after heating the heater and then slowly increased to a constant value. The temperatures at all locations were nearly at a steady state after about 37.5 days. In the steady state, the temperature was maintained at $90^{\circ}C$ at the interface between the heater and the bentonite and at about $70^{\circ}C$ at the interface between the bentonite and the confining cylinder. The variation of the water saturation with time in bentonite was almost same independent of the material laws used in the coupled T-H-M processes. By comparing the saturation change of T-H-M and that of H-M(Hydro-Mechanical) processes using elastic and poroelastic material mod31 respectively, it was found that the degree of saturation near the heater from T-H-M calculation was higher than that from the coupled H-M calculation mainly because of the thermal flux, which seemed to speed up the saturation. The stresses in three cases with different material laws were increased with time. By comparing the stress change in H-M calculation using poroelasetic and poroelasetic-plastic model, it was possible to conclude that the influence of saturation on the stress change is higher than the influence of temperature. It is, therefore, recommended to use a material law, which can model the elastic-plastic behavior of buffer, since the coupled T-H-M processes in buffer is affected by the variation of void ratio, thermal expansion, as well as swelling pressure.

  • PDF

Overseas Review on the In-situ Demonstration of EBS for IN-DEBS Development (공학적방벽 현장실증 시스템 (IN-DEBS) 개발을 위한 해외 실증연구 현황 분석)

  • Lee, Minsoo;Choi, Heui-Joo;Lee, Jong-Youl;Lee, Changsoo;Lee, Jae-Owan;Kim, Inyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.2
    • /
    • pp.107-119
    • /
    • 2014
  • The worldwide Status-of-Art survey for the in-situ experiments of the engineered barrier system for HLW underground disposal was performed as a preliminary action for the design of the in-situ demonstration at KURT. Some nations, which have executed or is ongoing the in-situ experiments at their underground research facilities, were summarized in this review. The demonstration projects reviewed were TBT/Sweden-France, LOT/Sweden, HE-E/Switzerland, PRACLAY/Belgium, FEBEX/Spain, HORONOBE/Japan, and BCE/Canada. The investigated items for the projects were mainly their purposes, constitutional structures, test conditions, monitoring parameters and the measuring tools, and test results. In this review, the hardware design and the assembling of the test system were more concentrated rather than their experimental results, because the purpose of this review is to achieve the necessary information for the practical design of the in-situ experiment to be installed at KURT. A mid scale in-situ demonstration of EBS at KURT, that is called IN-DBES, will be launched right after the completion the expanding project of KURT in 2015. It is hoped that the structural design, installing methods, hardware equipments required in the establishment of IN-DEBS will be referred on this review.

Blasting Impact by the Construction of an Underground Research Tunnel in KAERI (한국원자력연구소내 지하처분연구시설 건설에 따른 발파 영향)

  • Kwon Sang-Ki;Cho Won-Jin;Kim Deug-Su
    • Explosives and Blasting
    • /
    • v.23 no.4
    • /
    • pp.1-18
    • /
    • 2005
  • The underground research tunnel, which is under construction in KAERI for the validation of HLW disposal system, is excavated in a granite rock by drill&blasting. In order not to disturb the operation at the research facilities including Hanara reactor by the blasting for the excavation of $6m{\times}6m$ tunnel, a test blasting at the site was performed. Using the vibration equation derived from the test blasting, it was possible to predict the vibration at different locations at KAERI and to conclude that the blasting design would meet the design criteria at the major facilities in KAERI. The noise and vibration generated by the main blasting were continuously measured. In the case of vibration, the measured values were lower than the predicted one from the vibration equation. It is, therefore, concluded that the influence of blasting work for the construction of 280m long research tunnel on the major facilities in KAERIl would be insignificant.

Thermal-Hydro-Mechanical Behaviors in the Engineered Barrier of a HLW Repository: Engineering-scale Validation Test (고준위폐기물처분장 공학적방벽의 열-수리-역학적 거동 연구: 엔지니어링 규모의 실증실험)

  • Lee, Jae-Owan;Cho, Won-Jin
    • Tunnel and Underground Space
    • /
    • v.17 no.6
    • /
    • pp.464-474
    • /
    • 2007
  • An enhancement in the performance and safety of a high-level waste repository requires a validation of its engineered barrier. An engineering-scale test (named "KENTEX") has been conducted to investigate the thermal-hydro-mechanical behaviors in the engineered barrier of the Korean reference disposal system The validation test started on May 31, 2005 and is still under operation. The experimental data obtained allowed a preliminary and qualitative interpretation of the thermal-hydro-mechanical behaviors in the bentonite blocks. The temperature was higher as it became closer to the heater, while it became lower as it was farther away from the heater. The water content had a higher value in the part close to the hydration surface than that in the heater part. The relative humidity data suggested that a hydration of the bentonite blocks might occur by different drying-wetting processes, depending on their position. The total pressure was continuously increased by the evolution of the saturation front in the bentonite blocks and thereby the swelling pressure. Near the heater region, there was also a significant contribution of the thermal expansion of bentonite and the vapor pressure in the pores of the bentonite blocks.