• Title/Summary/Keyword: HI test

Search Result 480, Processing Time 0.024 seconds

An Investigation of Vehicle-to-Vehicle Distance Control Laws Using Hardware-in-the Loop Simulation (Hardware-in-the Loop Simulation 을 통한 차간거리 제어시스템의 제어 성능 연구)

  • Yi, Kyong-Su;Lee, Chan-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1401-1407
    • /
    • 2002
  • This paper represents an investigation of the vehicle-to-vehicle distance control system using Hardware-in-the-Loop Simulation(HiLS). Control logic is primarily developed and tested with a specially equipped test vehicle. Establishment of an efficient and low cost development tool is a very important issue, and test vehicle approach is costly and time consuming. HiLS method is useful in the investigation of driver assistance and active safety systems. The HiLS system consists of a stepper motor for throttle control, a hydraulic brake system with an electronic vacuum booster, an electronic controller unit, a data logging computer which are used to save vehicle states and signals of actuator through a CAN and a simulation computer using mathematical vehicle model. Adaptation of a CAN instead of RS-232 Serial Interface for communication is a trend in the automotive industry. Since this environment is the same as a test vehicle, a control logic verified in laboratory can be easily transferred to a test vehicle.

Comparison of ELISA and HI titers in broiler chicks vaccinated with infectious bronchitis virus and Newcastle disease virus (전염성기관지염 및 뉴캣슬병 백신을 접종한육계에서 ELISA 및 HI 항체가 비교)

  • 고원석;이정원;곽길한;권정택;송희종
    • Korean Journal of Veterinary Service
    • /
    • v.24 no.1
    • /
    • pp.21-29
    • /
    • 2001
  • To compare of serum antibody titers using ELISA and HI, serum samples were collected from 100 breeders and their progeny 550 broilers. The breeders and broilers were vaccinated with infectious bronchitis(IB)- and Newcastle disease(ND)-viruses according to general vaccination program. The antibodies in serum samples against IB and ND viruses were detected by enzyme-linked immunosorbent assay(ELISA) using commercial ELISA kit and hemagglutination inhibition(HI) test. Geometric mean titer(GMT) of ELISA and In titers were monitored from 1-day-old to 35-day-old broilers and compared to those of breeder chickens. The antibody titers of breeders vaccinated with ]B virus showed 47,800, ELISA and 7.2, HI, respectively. Progeny chicks, 1-day-old, vaccinated with IBV showed high antibody titers than those of breed chickens. Those chicks were maintained protective antibody levels until 11-day-old. From 14-day-old, the antibody level decreased below protective levels. In ND, breeders serum antibody titers ELISA and Eiu were 30,200 GMT and 8.7 HI titer, respectively. On 1-day-old chicks, antibody levels was decreased to half in ELISA(16,270) compared with those of breeders, but In titers was 7.4. Progeny broilers, protective antibody level was maintained until 14- day-old by ELISA, but at 11-day-old by HI titers. After then, ND antibody titer was continuously decreased underdefense level. These result indicated that the ELISA method be more sensitive than HI titration to detect serum antibody level for IBV and NDV.

  • PDF

Evaluation of hemagglutination inhibition test for canine respiratory coronavirus antibodies and seroprevalence in Korean dogs

  • Lee-Sang Hyeon;Dong-Kun Yang;Yu-Ri ,Park;Hye Jeong Lee;Ha-Hyun Kim;Bang-Hun Hyun
    • Korean Journal of Veterinary Research
    • /
    • v.63 no.4
    • /
    • pp.37.1-37.7
    • /
    • 2023
  • Canine respiratory coronavirus (CRCoV) is a significant pathogen that causes respiratory diseases in dogs, collectively known as a canine infectious respiratory disease. The virus is highly contagious and exhibits high seroprevalence worldwide. Currently, bovine coronavirus (BCoV) enzyme-linked immunosorbent assay (ELISA) kits are used to detect CRCoV antibodies. However, BCoV-ELISA kits cannot differentiate between infections caused by BCoV and those caused by CRCoV. In this study, we evaluated the hemagglutination inhibition (HI) test for CRCoV by comparing it with the virus neutralization (VN) test. Subsequently, we evaluated the seroprevalence of CRCoV in 383 dog serum samples collected from South Korea utilizing the HI test. The HI test for CRCoV showed a strong correlation with the VN test (R = 0.83, p < 0.001). The analysis of seroprevalence revealed that 52.2% (95% confidence interval [CI], 47.2%-57.1%) of the Korean dog serum samples were positive. The seroprevalence exhibited varied with age, with a positivity rate of 43.9% in dogs under 1 year of age and 66.7% in dogs aged 3 to 5 years (odds ratio, 2.54; 95% CI, 1.43-4.59). In conclusion, the HI test to monitor CRCoV antibody proved to be closely related to the VN test. Furthermore, over half of the dogs in Korea tested positive for CRCoV antibodies. These findings contribute to a better understanding of the sero-epidemiology of CRCoV.

MARGINAL LEAKAGE TEST ON 'Hi-Pol' ENAMEL BOND SYSTEM (국산 'Hi-Pol' Enamel Bond System의 변연누출에 관한 실험적 연구)

  • Kwon, Hyuk-Choon
    • The Journal of the Korean dental association
    • /
    • v.16 no.12 s.115
    • /
    • pp.935-940
    • /
    • 1978
  • The purpose of this study was to evaluate the marginal sealing ability of 'Hi-Pol' Enamel Bond system. Using freshly extracted human teeth and 2% acquous methylene blue, the marginal leakage of dye in restorative materials such as 'Hi-Pol' Enamel Bond system, Hi-Pol, Adaptic, Nuva system, Epolite and Amalgam were investigated at 37℃ and under temperature cycling in range of 4℃-60℃. the results as follows; 1. All filling materials showed some degree of marginal penetration by 2% methylene blue dye. 2. 'Hi-Pol' Enamel Bond system revealed the least marginal penetration by 2% methylene blue as Nuva did at 37℃, but under temperature cycling in range of 4℃-60℃ it showed the greatest marginal penetration. 3. Hi-Pol restoration showed a tendency the similar to the other composite restoration. 4. Nuva system had the most effective marginal sealing ability either at 37℃ and under temperature cycling.

  • PDF

Evaluation on the Fuel Efficiency of Hi-Pass System (고속도로 하이패스 시스템의 연료감소효과 평가)

  • Lee, Seong-Kwan Mark;Lee, Ki-Young;Choi, Yoon-Hwan;Kwak, Jin-Ho;Sung, Ji-Na
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.3
    • /
    • pp.59-66
    • /
    • 2010
  • Around a toll plaza, vehicles do such maneuvers as slow down, stop, and speed up to pay their tolls when they use ordinary toll gates. They can be expected more fuel consumptions compared to the vehicles which use the Hi-pass, a Korean type of Electronic Toll Collection System(ETCS). To measure the exact amount of difference between the two gas consumptions, we equipped a test vehicle with a measurement system and constructed a model toll gate on our test field. Through the field tests on fuel consumptions, we could confirm a 36.7 % of energy saving when the test car used the Hi-pass. Then we projected the result on the total traffic volumes which had used national expressway network for five months from January 2009. Projected to the whole traffic, potential cost savings reached 5.34 billion won. We expect this result be frequently mentioned of to prove the fuel efficiency of the Hi-pass system.

Development of HiFi Speaker System for Home Audio (홈 오디오 용 하이파이 스피커 시스템 개발)

  • Park, Seok-Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.317-322
    • /
    • 2004
  • In this paper, It was describe the processes of development of HiFi speaker system. Woofer and tweeter were fabricated by unskilled students and their 1.5 parameters were identified by known mass method. Based on T-S parameters port enclosure was designed and built by means of software. Acoustic radiation phenomena of port enclosure were simulated and compared to test result. Acoustic pressure difference between lower frequency and higher frequency was flattened by adopting optimal crossover network. Finally, built HiFi speaker system was showed good sound quality and sound pressure and electrical impedance was well agreed with test results each other.

  • PDF

Evaluation of immunogenicity of the 2008-2009 seasonal influenza vaccines by microneutralization test

  • Kim, Seung Youn;Kim, Yun Kyung;Eun, Byung Wook;Kim, Nam Hee;Kang, Eun Kyeong;Lee, Byong Sop;Lim, Jung Sub;Lee, Jun Ah;Kim, Dong Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.12
    • /
    • pp.474-480
    • /
    • 2012
  • Purpose: For evaluating the immunogenicity of an influenza vaccine, the microneutralization (MN) test has a higher sensitivity and specificity as compared to the hemagglutination inhibition (HI) test. However, the MN test is more time consuming and is difficult to standardize. We performed the MN test to determine its usefulness as an alternative or complementary test to the HI test for evaluating the immunogenicity of influenza vaccines. Methods: We compared the MN test with the HI test using 50 paired samples taken from a previous clinical study (2008-2009) in Korean children under 18 years of age. Results: The linear correlation coefficients of the 2 tests for H3N2, H1N1, and influenza B were 0.69, 0.70, and 0.66, respectively. We identified a high index of coincidence between the 2 tests. For an influenza vaccine, the postvaccination seroprotection rates and seroconversion rates determined by the MN test were 78.0% and 96.0%, 90% and 42.0%, and 42.0% and 48.0% for H3N2, H1N1, and influenza B, respectively. Geometric mean titer fold increases of H3N2, H1N1, and influenza B were 2.89, 5.04, and 4.29, respectively, and were 2.5-fold higher. We obtained good results in the evaluation of the immunogenicity of the 2008-2009 seasonal influenza vaccines. Conclusion: We found that the MN test was as effective as the HI test. Therefore, we suggest that the MN test can be used as an alternative or complementary test to the HI test for evaluating the immunogenicity of influenza vaccines.

Field Application Study for Soil Improvement and Existing Foundation Protection Work by Hi-FA(High performance and Multi functional Agent) (Hi-FA(유동성 및 점성 개질제)를 이용한 지반보강 및 기존 교량기초 보강공법에 대한 실용화 연구)

  • Kim, Myung-Hak;Park, Myoung-Deuk;Yoon, Tae-Gook;Lee, Yong-Jun;Park, Min-Cheol
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.664-675
    • /
    • 2010
  • Recently environment-friendly construction method is major trend in both domestic and world constrction fields. In this paper High Functional Performance Agent(Hi-FA) which has various improved engineering characteristics different with conventional Portland cement grouting, such as high viscosity, liquidity, void filling ability, early hardening, and separation resistance, was analyzed by field and laboratory test. Also soil improvement and existing deep foundation protection works were performed and analyzed using Hi-FA.

  • PDF

HI superprofiles of galaxies from THINGS and LITTLE THINGS

  • Kim, Minsu;Oh, Se-Heon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.68.3-69
    • /
    • 2021
  • We present a novel profile stacking technique based on optimal profile decomposition of a 3D spectral line data cube, and its performance test using the HI data cubes of sample galaxies from HI galaxy surveys, THINGS and LITTLE THINGS. Compared to the previous approach which aligns all the spectra of a cube using their central velocities derived from either moment analysis, single Gaussian or hermite h3 polynomial fitting, the new method makes a profile decomposition of the profiles from which an optimal number of single Gaussian components is derived for each profile. The so-called superprofile which is derived by co-adding all the aligned profiles from which the other Gaussian models are subtracted is found to have weaker wings compared to the ones constructed in a typical manner. This could be due to the reduced number of asymmetric profiles in the new method. A practical test made on the HI data cubes of the THINGS and LITTLE THINGS galaxies shows that our new method can extract more mass of kinematically cold HI components in the galaxies than the previous results. Additionally, we fit a double Gaussian model to the superprofiles whose S/N is boosted, and quantify not only their profile shapes but derive the ratio of the Gaussian model parameters, such as the intensity ratio and velocity dispersion ratio of the narrower and broader Gaussian components. We discuss how the superprofile properties of the sample galaxies are correlated with their other physical properties, including star formation rate, stellar mass, metallicity, and gas mass.

  • PDF

Immune Status of Breeding Hens Against Newcastle Disease (종계군(種鷄群)의 Newcastle Disease에 대(對)한 면역상태(免疫狀態)에 관(關)한 연구(硏究))

  • Yeo, Sang Geon;Choi, Won Pil
    • Korean Journal of Veterinary Research
    • /
    • v.19 no.1
    • /
    • pp.45-51
    • /
    • 1979
  • The present study was undertaken to observe the immune status of breeding hens and laying hens against Newcastle disease (ND). The methods of extraction of hemagglutination inhibition (HI) antibody from egg yolk, the detection of HI antibody in egg albumen and the correlation between HI antibody titers in maternal sera and egg yolks were discussed. For the purposes of these experiments, 9 flocks of breeding hens and 16 flocks of laying hens immunized against Newcastle disease virus were investigated. The vaccination program of tested flocks was 3-3-3 or 4-4-4 in general. The results obtained are summerized as follows: Freezing-thawing was the best method far antibody extraction from egg yolk for HI test. The HI antibody against NDV was found in egg albumen (geometric mean, 4.5), but lower than that found in egg yolk (32.1). The geometric mean of HI antibody titers of egg yolks (84.1) was higher than that of maternal sera (68.4) and day-old chicken sera (25.3). There was correlation between HI antibody titers of maternal sera(Y) and those of egg yolks(X). The coefficient correlation was r=0.63, and the line of regression of Y on X was $\hat{Y}$=35.91+0.35X.

  • PDF