MARGINAL LEAKAGE TEST ON 'Hi-Pol' ENAMEL BOND SYSTEM

국산 'Hi-Pol' Enamel Bond System의 변연누출에 관한 실험적 연구

  • Kwon, Hyuk-Choon (Dept. of Operative Dentistry, College of Dentistry, Seoul National University)
  • 권혁춘 (서울대학교 치과대학 보존학교실)
  • Published : 1978.12.30

Abstract

The purpose of this study was to evaluate the marginal sealing ability of 'Hi-Pol' Enamel Bond system. Using freshly extracted human teeth and 2% acquous methylene blue, the marginal leakage of dye in restorative materials such as 'Hi-Pol' Enamel Bond system, Hi-Pol, Adaptic, Nuva system, Epolite and Amalgam were investigated at 37℃ and under temperature cycling in range of 4℃-60℃. the results as follows; 1. All filling materials showed some degree of marginal penetration by 2% methylene blue dye. 2. 'Hi-Pol' Enamel Bond system revealed the least marginal penetration by 2% methylene blue as Nuva did at 37℃, but under temperature cycling in range of 4℃-60℃ it showed the greatest marginal penetration. 3. Hi-Pol restoration showed a tendency the similar to the other composite restoration. 4. Nuva system had the most effective marginal sealing ability either at 37℃ and under temperature cycling.

Keywords