탄화수소계 냉동공조 시스템의 성능특성에 관한 실험 (Performance Characteristics of Refrigeration and Air Conditioning System Using Hydrocarbon Refrigerants)

  • 이호생;이근태;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권5호
    • /
    • pp.728-734
    • /
    • 2004
  • Environmentally friendly refrigerants with zero ozone layer depletion potential are required to be used in refrigerators and air conditioners due to the difficulties related to ozone layer depletion and global warming. A rigorous study for the system performance with new refrigerants having zero ozone layer depletion potential is inevitable before adopting that as a new fluid. The HFC(Hydrofluorocarbon) potential has been recommended as alternatives. In this paper. system performance in the heat pump facilities were studied using R-290, R-600a. R-1270 as an environment friendly refrigerant. R-22 as a HCFC's refrigerant. The experimental apparatus has been set-up as a conventional vapor compression type heat Pump system. The test section is a horizontal double pipe heat exchanger. A tube diameter of 12.70mm with 1.315mm wall thickness is used for this investigation. The test results showed that the COP of hydrocarbon refrigerants were superior to that of R-22 and the maximum increasing rate of COP was found in R-1270. The refrigeration capacity of hydrocarbon refrigerants were higher than that of R-22. The compressor work was obtained with the maximum value in R-1270 and the minimum one in R-22.

The Friction Characteristics of the Journal Bearing in the Refrigerant Compressor

  • Cho, Ihn Sung;Baek, Il Hyun;Oh, Seok Hyung;Jung, Jae Youn
    • KSTLE International Journal
    • /
    • 제1권2호
    • /
    • pp.113-117
    • /
    • 2000
  • The rotary-vane compressor has become one of the most successful types of compressors because of its mechanical reliability, compactness, and adaptability to moderately high-speed operation in virtually an unlimited range of sizes. However recently, the depletion of the ozone layer due to the current refrigerant(R22) has been getting worse, and it is one of the world's pressing issues. In this paper, we will discuss the use of R410a in the compressor of a room air-conditioner as an alternative refrigerant and air-conditioning system to R22, since R410a has greater refrigerant characteristics than R22. Miniaturization of the rotary compressor for the new refrigerant and air-conditioning system is also possible, which reduces the prime cost of production, hence R410a is naturally a better refrigerant. But to apply the new HFC refrigerant system in refrigeration and air-conditioning systems, a significant redesign of the current refrigerant system is also required, because as the refrigeration changes, lubrication characteristics vary. Close attention must be paid to friction force and energy loss due to friction and wear at many sliding areas.

  • PDF

대체냉매 공기조화기용 로터리 압축기의 성능향상을 위한 최적 토출계에 관한 실험적 연구 (An Experimental Study on the High Performance Optimal Discharge System of a Rotary Compressor for an Air Conditioner using alternative Refrigerant R410a)

  • 윤영;정진택;민만기
    • 설비공학논문집
    • /
    • 제13권2호
    • /
    • pp.96-105
    • /
    • 2001
  • R410a which is one of HFC refrigerants is being considered to be a promising replacement for R22 widely used in domestic air conditioners. The rolling piston type rotary compressors for R410a have lower energy efficiency than those for R22 because of the high pressure difference between a suction chamber and a discharge chamber in the compression mechanism. in addition, the re-expansion gas loss of the rotary compressor for R410a which occurs a ta clearance volume in a discharge port becomes larger than that for R22 due to high density of R410a refrigerant. Therefore, Pressure-Volume analyses for various design parameters of a discharge system were carried out to improve efficiency of a R410a rotary compressor. The results such as performance dta, over-compression loss, and re-expansion loss were acquired by P-V analyses and analyzed quantitatively. As a conclusion, the optimal specifications of several design parameters of a discharge system were obtained by analyzing P-V diagrams.

  • PDF

초고속 액세스 망의 모델화 및 경제성에 대한 검토 (A study onthe modeling of broadband access network for national information infrastructure and numerical analysis of its economics)

  • 정해원;박기식;노장래;조성준
    • 한국통신학회논문지
    • /
    • 제22권12호
    • /
    • pp.2806-2818
    • /
    • 1997
  • 본 논문은 초고속 광 가입자 망의 대안 기술에 대한 경제성 비교 검토로서, 교환기와 국간 전송로인 기반 통신 망의 고속 디지탈화 및 지능화는 완성 되었다고 보고, 액세스 계에 대하여 xDSL, FTTx, HFC, HFR의 접속 기술을 적용한 4가지 방식에 대하여 실제에 근접한 모델과 수식을 세우고, 각 모델에 대한 경제성 비교 분석을 수행하였다. 각각의 모델에 대한 수식은 서비스 제공 영역인 셀의 크기(즉, 가입자 밀도)를 변수로 하고, 각 요소 기능의 비용을 동선 비용으로 정규화한 값으로 대입하였다. 비용 구조에 대한 수치 계산 결과로부터 얻을 수 있는 결론으로 이용자의 밀도, 액세스 통신망의 구성 등에 따라 최적의 액세스 통신 기술이 달라져야 함을 알 수 있었다. 본 논문에서 제시한 해석 모델과 수식 등은 각각의 통신 환경에 대한 최적의 초고속 가입자 액세스 기술의 선정 시에 기여를 할 수 있으리라 기대된다.

  • PDF

냉장고 사이클 특성에 미치는 열손실량의 영향 (Effect of heat Leak on Cycle Characteristics of Refrigerator)

  • 신진규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.871-879
    • /
    • 1998
  • The refrigerator consists of many components such as compressor condenser expansion valve evaporator and the cabinet which filled by urethane foam. In this paper the heat leakage of refriger-ator is measured by the new experiment method which is different from a present method, The devi-ation of the UA(overall heat transfer coefficient times area) between the simulation and experiments is about 7-8%. Using the modeling of various components of refrigeration system a performance analysos of CFC 12 and HFC 134a is performed numerically on the UA. As the results of this study according to increase the heat leakage the refrigeration load and mass flow rate of refrigerant are increased. And the increase of the mass flow rate results in the increase of the condensing and evapo-rating temperature. Therefore according to increase of the heat leakage the COP leads to increase because the increase of refrigeration capacity is larger than the increase if compressor power.

  • PDF

냉장고 특성 시뮬레이션 (Simulation of Refrigerator Characteristics)

  • 문춘근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권2호
    • /
    • pp.181-189
    • /
    • 1998
  • A general steady-state model for simulation on domastic refrigerator has been developed. The system model consists of various standard components such as evaporator compressor condenser capillary tube and cabinet. Cabinet is not system component but influence characteristic on domastic refrigerator. The purpose of this paper is to compare between characteristics of HFC 134a with CFC 12 in the domastic refrigerator and to predict the steady state cycle performance which is various specifications of cycle components under the continuous running conditions. As the results of simulation the coefficient of performance of both condenser and evaporator increases with increasing UA the increasing rate for condenser is greater than for evaporator.

  • PDF

수평 평활관 및 전열촉진관내 대체 냉매 R-407C의 응축 열전달 특성에 관한 연구 (Heat Transfer Characteristics of R-407C During Condensing Inside Horizontal Smooth and Micro-Fin Tubes)

  • 노건상;오후규
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.210-217
    • /
    • 1999
  • This paper reports the experimental results on heat transfer characteristics of R-22 and R-407C(HFC-32/125/134a 23/25/52 wt%) condensing inside horizontal smooth and finned tubes. The test condensers used In the study are double pipe heat exchangers of 7.5 mm ID, 9.5 mm OD smooth tube, and 60 finned micro-fin tube with 8.53 mm ID, 9.53 mm OD. Each of these tubes was 4 000 mm long tubes connected with an U-bend. These U type two-path test tubes are divided In 8 local test sections for the identification of the local condensing heat transfer characterisitcs and pressure drop, U-bend effects on condensing flows. Inlet quality is maintained 1.0, and refrigerant mass velocity is varied from 102.0 to $301.0kg/m^2{\cdot}s$. From the results, it was found that the pressure drop of the R-407C Increased, and heat transfer coefficient decreased compared to those of R-22. In comparison condensing heat transfer characteristics of micro-fm tube with those of smooth tube, increasing of condensing heat transfer coefficient was found outstanding compared to the increasing ratio of pressure drop. Furthermore, pressure drop In U-bend showed at most a 30 % compared to the total pressure drop in the test section.

HCFC-22 대체냉매의 모세관 선정 (Selection of Capillary Tubes for HCFC-22 Alternative Fluids)

  • 정동수;김종보
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.435-449
    • /
    • 1995
  • In this paper, pressure drop through a capillary tube is modeled to determine the length of a capillary tube for a given set of conditions. HCFC-22 and its alternatives, HFC-134a, R407B, and R410A are used as working fluids. The conditions on which the model is tested are as follows : condensing temperature; 40.0, 45.0, 50.0, $55.0^{\circ}C$, degree of subcooling;0.0, 2.5, $5.0^{\circ}C$, capillary tube exit condition;choked flow, capillary tube diameter;1.2~2.4mm, mass flow rate;5.0~50.0g/sec. The results justify the use of Stoecker's model which yields the results very close to the values in ASHRAE handbook. While McAdams' method yields much better results than Duckler's in calculating the viscosity of the fluid in 2-phase, the friction factor suggested by Stoecker seems to be the best for capillary tubes of large diameter used in residential air conditioners. For each refrigerant, 372 data with various variables are calculated by the model. The results show that capillary tube length varies very uniformly with changes in condensing temperature and degree of subcooling. Based on this fact, regression analysis is performed to determine the dependence of mass flow rate on the length and diameter of a capillary tube, condensing temperature, and degree of subcooling. Thus determined correlation yields a mean deviation of 2.36% for 1,488 data, showing an excellent agreement.

  • PDF

초음파가 뇌파에 미치는 영향 (The effect of hypersonic wave sound for EEG)

  • 장석우;박인길;김대겸;최현
    • 감성과학
    • /
    • 제17권2호
    • /
    • pp.101-110
    • /
    • 2014
  • 초음파는 비가청영역에서 나는 사운드이며 일상생활에서는 들을 수 없다. 초음파는 22kHz 이상의 주파수를 말하며 또한 이러한 성분을 초음파 성분 HFCs(High Frequency components)라고 한다. 파도소리는 사람에게 안정감과 알파파를 유도한다고 알려졌는데 이러한 이유는 파도소리에 초음파 성분이 매우 많다는 것이다. 이러한 초음파가 파도소리와 합쳐질 때 쾌감을 주고 알파파 증가와 베타파가 감소하는 초고주파효과(hypersonic effect)라고 한다. 본 실험에서는 파도소리를 들려주면서 동시에 파도소리에 해당되는 초음파부분을 전자회로로 설계하여 인위적으로 파도소리의 초음파 성분과 유사하도록 제작하여 실험하였다. 뇌파는 8채널을 사용하여 Fp1, Fp2, F3, F4, T3, T4, O1, O2 의 총 8개 전극을 부착하였다. 뇌파에서는 집중이나 긴장이완 등이 나타날 때 알파파가 나타나며 각성상태나 긴장상태 그리고 스트레스상태에서는 주로 베타파가 나타난다. 초음파 실험결과 연구대상자들의 알파파가 증가하고 베타파가 감소하는 현상이 통계적으로 유의미하게 나타났으며 초고주파현상이 반영되는 결과가 나타났다.

증기압축식/흡수식 하이브리드 히트펌프 사이클에 관한 최적화 연구 (Optimization Study of the Compression/Absorption Hybrid Heat Pump Cycle)

  • 전관택;박춘건;정동수
    • 설비공학논문집
    • /
    • 제13권1호
    • /
    • pp.48-58
    • /
    • 2001
  • For the past few decades the vapor compression cycle with a solution circuit (VCCSC) has been known to provide high efficiency and variable capacity. In this study performance of a VCCSC cycle is examined through computer simulation. In the simulation heat exchangers were modelled by specifying UA or effectiveness values while the compressor performance was specified by an isentropic efficiency. Aqua/ammonia solution was chosen as the working fluid which can be used in the high temperature range. The results show that there exists an optimum operation condition which is dependent upon the temperatures of the external heat transfer fluids(HTFs). Besides the HTF\`s temperature, the maximum system pressure and the size of the solution heat exchanger are shown to have an influence on the optimum operation condition. Finally, as compared to a simple vapor compression heat pump with HFC134a, the COP of the VCCSC is shown to be 2∼22% higher.