• 제목/요약/키워드: HCHO (Formaldehyde)

검색결과 125건 처리시간 0.028초

혈장변성접착제를 사용한 내수합판의 특성 (Properties of Water Resistant Plywood made with Modified Serum Protein Adhesive)

  • 강석구;이화형
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권1호
    • /
    • pp.21-27
    • /
    • 2011
  • This study was carried out to examine properties of water resistant plywood by using serum protein adhesive which is natural, environment-friendly and human-friendly. For the preparation of the serum protein adhesive, pig blood from slaughterhouse was centrifuged and serum was separated from corpuscles and concentrated to 30% by dry weight basis. This concentrated serum protein was modified with PF resin (50% NVC) with the ratio of 9 : 2.5. Plywood made by this modified serum protein gave 1.21 N/$mm^2$ of dry bonding strength, 0.80 N/$mm^2$ of wet boil bonding strength, 0% of cyclic delamination test value, and 0.025 ppm of HCHO emission, which met the excellent super $E_0$ grade and water resistant plywood.

형광광도법을 이용한 오존 passive sampler의 개발 (Development of ozone passive sampler with fluorescence intensity method)

  • 김한수;김선태;윤은영;김신도
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2001년도 추계학술대회 논문집
    • /
    • pp.245-246
    • /
    • 2001
  • 우리나라에서는 지금까지 대기 오염과 관련하여 환경기준 달성을 위한 정책수립에 있어서 대상물질은 주로 이산화황(SO$_2$)과 먼지(TSP) 등으로 경제개발과 산업발전과정 등에서 발생되는 오염물질이었다. 그러나 최근 몇 년사이 급격한 자동차의 증가로 인한 이산화질소(NO$_2$)와 휘발성유기화합물(VOCs)의 배출이 증가하고 있어 환경규제정책도 점차 변하고 있는 실정이다. 이러한 오염물질들이 대기중에서 태양복사에너지에 의해 광화학 반응을 일으켜 오존(ozone), PAN(peroxyacethyl nitrate), PBN(peroxy benzoyl nitrate), 아크로레인(carolein), 포름알데히드(HCHO, formaldehyde) 등 광화학 산화제를 생성하여 인체, 동ㆍ식물 및 재산상의 피해를 유발하고 있다. (중략)

  • PDF

신축 공동주택에서의 강제환기장치 사용에 따른 실내공기질 개선효과 실증연구 (Experimental Study on the Effect of Ventilation System on Indoor Air Quality in New Apartment Buildings)

  • 이규동;박영석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.143-146
    • /
    • 2006
  • There has been growing concern regarding IAQ(Indoor Air Quality) recently, and IAQ problems from the air-tightness and use of chemical materials addition to the building materials have become increasingly important factors in the built environment. Ventilation is supposed as the solution of healthy indoor quality, and Korea government requests that all new apartment buildings must have a ventilation system as a matter of duty since January, 2006. The purpose of this study is to investigate the indoor concentration change of VOCs include the Formaldehyde according to many different ventilation supply types. Results showed that the reduction effect of target pollutants by the ventilation system was very slight. The cause of these results was attribute to increase the emission rate of building materials by increasing the ventilation rate.

  • PDF

신축 공동주택 및 건축자재에서의 오염물질 방출 특성 (A Study on the Emission Characteristics of Gaseous Organic Contaminants from Building Materials and Newly Constructed Apartments)

  • 김윤덕;이윤규
    • 설비공학논문집
    • /
    • 제18권7호
    • /
    • pp.563-570
    • /
    • 2006
  • We investigated the emission characteristics of gaseous organic contaminants from building materials and newly constructed apartments. The emission test for building materials was done with small chamber method, and field measurements in newly constructed apartment were carried out by Korea Standard Test Method for Indoor Air Quality. First, the emission test by small chamber showed that the TVOC emission from building materials was much higher than formaldehyde. On the other hand, as expected, considerably high concentration of both TVOC and HCHO was detected in the new apartment.

광촉매공정과 필터를 이용한 흡연부스 공기정화연구 (Air Purification of Smoking Booth Using Photocatalytic Process and Air Filter)

  • 김태영;조영태;김재용
    • 공업화학
    • /
    • 제27권4호
    • /
    • pp.433-438
    • /
    • 2016
  • 본 연구에서는 CO, HCHO, $CH_3CHO$, PM10, PM2.5 등의 담배연기 내에 포함된 유해물질들의 농도를 지표로 광촉매와 필터로 구성된 공기정화장치를 부착한 흡연부스 내의 공기질을 평가하였다. 또한 광촉매에서 발생되는 OH 라디칼과 담배연기 내 가스상 유해물질들과의 반응성을 향상시켜 제거효율을 높이기 위해 적외선을 주사하였다. 공기정화장치와 필터를 활용한 흡연부스의 실험 결과, 시스템 가동 전보다 가스상 오염물질은 포름알데히드 포함 최대 85.2% 향상된 제거효율을 나타냈다. 처리 후의 미세먼지는 최대 89.4% 향상된 제거효율을 나타냈다.

합판 공장 부산물을 이용한 파티클보드의 물성에 관한 연구 - 표층 구성요소 및 파티클 전처리 여부에 따른 비교 - (Properties of Particleboard Using Byproduct of Plywood Manufacture - Evaluation on the Elements of Surface Layer and Pre-treatment of Particles)

  • 황정택;피덕원;강석구
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권1호
    • /
    • pp.33-41
    • /
    • 2013
  • 본 연구에서는 최근 파티클보드(Particle Board ; 이하 PB)의 원재료로 재활용되고 있는 목재 폐기물 중 합판공장의 부산물을 원재료로 사용하고 비포름알데히드계 EMDI접착제의 적용을 통한 제조조건을 최적화하여 재활용 원재료의 효과적인 활용을 통한 고(高)내수성 PB의 개발과 그에 대한 물리 기계적 특성을 규명하고자 하였다. 그 결과, (1) 베니어 적층 복합보드에 EMDI수지를 사용하였을 경우 휨 강도가 섬유방향 57.7 $N/mm^2$, 섬유 직각방향 25.1 $N/mm^2$의 강도를 나타내었다. (2) 두께팽윤율과 수분흡수율은 U형, M형, P형 실험에서 EMDI수지가 UF수지보다 높은 수준의 내수성을 나타내었다. (3) 잔존 포름알데히드의 양을 줄이고자 실행하였던 72시간 수침전처리는 파티클보드의 포름알데히드 방산량을 증가시키는 결과를 초래하였다.

호남지역의 다중이용시설별 실내공기질 실태 조사 (Indoor Air Quality in Various Type of Public Facilities at Honam Province)

  • 서병량;정만호;전준민
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.387-397
    • /
    • 2006
  • This study was performed to investigate the characteristics of indoor air quality(IAQ) in 91 public facilities from September 2004 to March 2005 in the Honam province(Chonnam, Gwangju). The measured air pollutants are $PM_{10}$, formaldehyde(HCHO), CO, $CO_{2}$ and total suspended bacteria(TSB), the maintenance standard materials of IAQ management law established by ministry of environment in Korea(MOE). We also surveyed establishment and operation of ventilation equipment. It was measured $1.2m{\sim}1.5m$ on the floor between 8 o'clock AM and 7 o'clock PM. As the result, $PM_{10}$ and CO was showed the highest concentration, $188.89{\mu}g/m^{3}$, 8.67 ppm, at the indoor parking. The concentration of HCHO was the highest in large store and steamer room. The concentration was respectively $118.70{\mu}g/m^{3}\;and\;113.21{\mu}g/m^{3}$. The concentration of $CO_{2}$ was the highest at the reading room of the library on the condition of natural ventilation. The concentration of $CO_{2}$ was 1,816 ppm and higher than the IAQ standards established by MOE. The TSB was just measured in the hospital and silver town. It was the highest at the admission room of hospital. The concentration of TSB was $766CFU/m^{3}$. The public facilities of this study were not exceed each maintenance standards except $CO_{2}$ but it was surveyed that the management will be needed about some air pollutant according to target facilities.

일부 수도권지역에서의 키즈카페 내 유해물질 노출수준 평가 (Assessment for Exposure Levels of Hazardous Substances in Kids Cafes within Some Metropolitan Area)

  • 김호현;안선민;이재영;최인석;이정훈;남의현;유시은;정다영;이철우;박충희
    • 한국환경보건학회지
    • /
    • 제45권1호
    • /
    • pp.54-61
    • /
    • 2019
  • Objectives: In this study, we investigated an assessment for exposure levels of hazardous substances to kids cafes that unregulated by law. Methods: Heavy metals, volatile organic compounds, formaldehyde, pesticides and phthalate were measured at 20 kids cafes in Gyeonggi-do and Incheon. Samplings were conducted from April to July in 2018. Results: Heavy metals were detected over the standard mainly around the floor and walls in the 19 kids cafes. Pesticides were detected in 7 locations with chlorpyrifos, diazinon and cypermethrin, and showed the highest detection level of chlorpyrifos. The concentrations of DEHP in all kids cafes were exceeded with standard. The risk assessment results showed that HCHO as carcinogen had a safety level and DEHP as non-carcinogens had a safety level as assessed to be under than 0.1. Conclusions: Considering the exposure investigation results and the importance of child health protection, kids cafe should be included in the legal management list of children's activities zones.

광촉매 건축자재와 환기시스템 적용에 따른 건축 환경 개선 방안 (Improvement of the Architectural Environment by Applying Photocatalyst Building Materials and Ventilation Systems)

  • 송용우;김성은;임세현;심성진
    • 토지주택연구
    • /
    • 제14권4호
    • /
    • pp.103-110
    • /
    • 2023
  • 하루 평균 대부분을 실내에서 보내는 현대인들은 내외부적으로 발생하는 실내오염물질에 지속적으로 노출되고 있다. WHO(World Health Organization) 2022년 보고서에 따르면 매년 세계적으로 약 700만명 이상의 사망 원인이 공기오염으로 실내오염물질의 심각성을 강조하고 있다. 대기오염물질 중에는 인체에 심각한 영향을 끼치는 질소산화물(NOx), 폼알데하이드(HCHO), 휘발성 유기화합물(VOCs) 등이 포함되는데, 이러한 실내공기 오염물질을 제거할 수 있는 물질로 광촉매가 있다. 광촉매는 미세먼지 전구물질 제거 성능뿐만 아니라 향균, 살균, 탈취 성능 또한 가지고 있어, 실내공기질 개선에 효과적이다. 이에, 본 연구에서는 광촉매를 건축물에 적용할 수 있는 부위 및 방안을 제시하였다. 적용 가능한 부위로는 내외장재, 콘크리트 등을 포함한 건축자재, 유기도료, 환기장치 등이 있으며, 각 부위에 최적 적용 방안에 대한 연구를 진행하였다.

서울시 일부 학교의 실내 공기질 조사 및 인식도 평가 (Assessment of Conscious Coginition Degree and Survey on the Indoor Air Quality at a public School in Seoul)

  • 손종렬;변상훈;김영환;김종혁;조윤수;이재영;박윤주
    • 환경위생공학
    • /
    • 제18권3호통권49호
    • /
    • pp.100-109
    • /
    • 2003
  • Recently, Indoor air quality(IAQ) in workplace, residential environments and schools has been concern of people, scientists and related the public. And so in Seoul has recognized the healthy effect related to IAQ in schools. Therefore, the objective of this study reported in this article were to measure and compare the perception of IAQ of selected air pollutants at three different schools in Seoul. We performed a questionnaire survey of 400 students about their awareness for the importance of IAQ in our school. And we measured the IAQ of 3 schools considering as site region, construction year and studying level. The indoor air pollutants and parameters such as temperature, relative humidity, respirable particulate matter(PM10), formaldehyde(HCHO), total bacteria counts(TBC), carbon dioxide(CO$_2$), and noise were monitored in indoors. In results, all most response of occupant has recognized the awareness of IAQ at schools. The PMIO, TBC and Noise level of all schools were higher than the standard of the public 150 ${mu}$g/m$^3$ and 500CFU/m$^3$, the level formaldehyde(HCHO) was below 0.1 ppm of the healthy guideline of Korea And the concentration of CO$_2$ were investigated below 1,000 ppm of the standard implying ventilation in 2 schools except for 1 school(c school). Finally, the control of most important pollutants of IAQ in school were PM10, TBC and Noise. Therefore, it can be concluded that the indoor air quality of selected 3 schools studied was perceived as acceptable, it is recommended that the government related IAQ was suggested the guideline and control of IAQ problems in schools, and all member relating school need to be effort to reduce the exposure of sources to undesirable indoor pollutants such as Particlate and Noise.